• Title/Summary/Keyword: superconducting power machine

Search Result 40, Processing Time 0.024 seconds

Power System Stabilization Using SMES (초전도에너지 저장장치를 이용한 전력계통 안정도 향상)

  • 조병욱;박종근
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.34 no.6
    • /
    • pp.213-219
    • /
    • 1985
  • Superconducting Magnetic Energy Storage (SMES) system can be used for power system stabilization by absorbing or discharging active and reactive power through thyristor-comtrolled converters. In this paper, we have proposed a control algorithm that the active and reactive powers of SMES are simultaneously controlled to increase power system dynamic stability. The proposed method was applied to one machine-infinite and three machines and three load model systems. And it has been shown that the proposed algorithm is more effective in power system stabilization than the conventional one that only the active power of SMES is controlled. Eigenvalue sensitivity analysis method is introduced to estimate the optimal location of SMES in the sense of the power system oscillation mode.

  • PDF

Recovery Characteristics of a Flux-lock Type HTSC Fault Current Limiter after Fault Removal (자속구속형 고온초전도 사고전류 제한기의 사고제거 후 회복특성)

  • Lim, Sung-Hun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.9
    • /
    • pp.812-815
    • /
    • 2007
  • To apply the superconducting fault current limiter(SFCL) into a power system, the analysis for its recovery characteristics as well as the consideration for its cooperation with other protecting machine such as a circuit breaker is required. The recovery characteristics of the flux-lock type SFCL like its current limiting characteristics are dependent on the winding direction of two coils. In this paper, the experiments of the current limiting and the recovery characteristics of the flux-lock type SFCL with YBCO thin film were performed. From the analysis on the experimental results due to the winding direction of two coils, the limited fault current in case of the additive polarity winding was observed to be lower than that for the case of the subtractive polarity winding. In addition, the recovery time was found to be faster in case of the additive polarity winding compared to the subtractive polarity winding.

KO AC/DC Converter System Installation Status and Commissioning Plan at ITER Site (이터 초전도자석 전원공급장치 현장 설치현황 및 시운전 계획)

  • Song, Inho;Oh, Jong-Seok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.5
    • /
    • pp.397-401
    • /
    • 2022
  • The construction of the ITER tokamak machine is ongoing at a 77% process rate to achieve the first plasma in 2025. The 18 sets of power supply systems comprising 400 MVA thyristor AC/DC converters for the superconducting magnets supplied by Korea (KO) are being installed with other systems, such as PF converters (China), DC busbars (Russia), and cooling water systems (India), in two buildings (Europe). The system interfaces have been defined during the design stage, and the systems have been manufactured. However, during the on-site installation work, several installation and integration issues emerged due to the manufacturing tolerance and design mistakes. To continue the installation and testing, the engineers of each system resolved the interface issues, planned the commissioning, and integrated the test plan. This paper describes the on-site installation status and issues and the commissioning plan of KO AC/DC converters.

A Study on the Optimal Site and Capacity of SMES for Power System Stabilization (계통안정화를 위한 SMES의 적정위치와 용량설정에 관한 연구)

  • Lee, Jae-Min;Lim, Jae-Yoon;Lee, Jong-Pil;Kim, Jung-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 1997.07c
    • /
    • pp.794-796
    • /
    • 1997
  • The superconducting magnetic energy storage (SMES) system is considered to be useful to charge or release an energy in power system because of the high efficiency and quick response. But we need much capital to construct and to operate a SMES. A site and capacity of SMES are important elements for effective operating and planning. In this paper, we proposed a performance function to determine an optimal site and capacity of SMES according to variety condition of power system such as fault point. In addition, to demonstrate the validity of a proposed method, the simulations were carried out on two-machine 5-bus system.

  • PDF

Development and Characteristic Analysis of a 10kVA HTS Power Transformer (10kVA고온초전도변압기의 특성해석 및 제작)

  • Lee, Hui-Jun;Cha, Gwi-Su;Lee, Ji-Gwang;Choe, Gyeong-Dal;Ryu, Gyeong-U;Han, Song-Yeop
    • Progress in Superconductivity and Cryogenics
    • /
    • v.2 no.2
    • /
    • pp.37-43
    • /
    • 2000
  • This paper describes the construction and test results of a 10kVA single phase HTS transformer. Double pancake windings with BSCCO-2223 HTS tape and G10-FRP cryostat with room temperature bore are used in the transformer. Two double pancake windings are connected in series to provide 188 turns and other two double pancake windings are connected in parallel to conduct the secondary current of 45.4[A]. Coefficients of the constructed transformer are obtained using the fundamental teats of the transformer. According to the test results, larger leakage reactance than expected is observed due to the bulky core which surrounds the sryostat.

  • PDF

Test and Characteristic Analysis of an HTS Power Transformer (고온초전도변압기의 특성해석 및 시험)

  • Lee, H.J.;Cha, G.S.;Lee, J.K.;Choi, K.D.;Ryu, K.W.;Hahn, S.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2000.11b
    • /
    • pp.321-323
    • /
    • 2000
  • This paper describes the construction and test results of a 10kVA single phase HTS transformer. Double pancake windings with BSCCO-2223 HTS tape and GFRP cryostat with room temperature bore are used in the transformer. Two double pancake windings are connected in series to provide 184 turns and two double pancake windings are connected in parallel to conduct the secondary current of 45.4A. Coefficients of the constructed transformer are obtained using the fundamental tests of the transformer. According to the test results, larger leakage reactance than expected is observed due to the bulky core which surrounded the cryostat.

  • PDF

A study on design process of HTS bulk magnet synchronous motors

  • Jaheum Koo;JuKyung Cha;Jonghoon Yoon;Seungyong Hahn
    • Progress in Superconductivity and Cryogenics
    • /
    • v.26 no.1
    • /
    • pp.1-4
    • /
    • 2024
  • This study explores the use of a bulk type high-temperature superconductors (HTS) as trapped field magnets in synchronous motors. A HTS bulk is examined for its ability to generate powerful magnetic fields over a permanent magnet and to eliminate the need for a direct power supply connection compared to a tape form of HTS. A 150 kW interior-mounted bulk-type superconducting synchronous motor is designed and analyzed. The A-H formulation is used to numerical analysis. The results show superior electrical performance and weight reduction when comparing the designed model with the conventional permanent magnet synchronous motor of the same topology. This study presents HTS bulk synchronous motor's overall design process and highlights its potential in achieving relatively high power density than conventional permanent magnet synchronous motor.

A study on the safe operation condition for Bi-2223/Ag tapes with applied alternating currents (교류용 Bi-2223/Ag 선재의 안정 통전 조건에 관한 연구)

  • Yim S. W.;Sohn S. H.;Hwang S. D.;Lim S. H.
    • Progress in Superconductivity
    • /
    • v.6 no.2
    • /
    • pp.138-141
    • /
    • 2005
  • Bi-2223/Ag tapes need to be safe, even it is under the over-critical current state for the protection of a superconducting power machine. However, it is not easy to identify the condition for the safe operation because of their broad S/N transition region. In this paper, for the study of the operation condition of Bi-2223/ Ag tapes, we investigated the V-I curves and the temperature variation of Bi-2223/ Ag tapes experimentally, applying alternating over-currents, and analyzed the relationship between resistance and temperature increase. For the experiments, a Bi-2223/Ag tape of 57 A $I_c$ was prepared, and the over-critical current characteristics under adiabatic state from $LN_2$ was measured. From the experiments, we confirmed that the Joule heating predicted by V-I curve corresponded with the increase of the measured temperature exactly. Using the results, a safe operation condition of Bi-2223 tape was discussed.

  • PDF

Characteristic of Transport Current Losses of Multi-Stacked YBCO Coated Conductors (적층 수에 따른 YBCO 선재의 전송전류 손실 특성)

  • Han, Byung-Wook;Lim, Hee-Hyun;Kang, Myung-Hun;Lim, Hyoung-Woo;Cha, Guee-Soo;Lee, Hee-Joon
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.599-600
    • /
    • 2006
  • Multi-slacked HTS tapes are needed to conduct large current in the power application of superconducting machine. This paper deals with the transport current loss of multi-stacked YBCO coated conductor. YBCO coated conductor that was used in this experiment has two Cu layers above and below of YBCO layer for stabilization. Transport losses of four different stacks, single, 2 stack, 3 stack and 4 stack, were measured. Measured results were compared analytic equation suggested by Norris.

  • PDF

Characteristic of Transport Current Losses of Multi-Stacked YBCO Coated Conductors (적층 수에 따른 YBCO 선재의 전송전류 손실 특성)

  • Han, Byung-Wook;Lim, Hee-Hyun;Kang, Myung-Hun;Lim, Hyoung-Woo;Cha, Guee-Soo;Lee, Hee-Joon
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.2231-2232
    • /
    • 2006
  • Multi-stacked HTS tapes are needed to conduct large current in the power application of superconducting machine. This paper deals with the transport current loss of multi-stacked YBCO coated conductor. YBCO coated conductor that was used in this experiment has two Cu layers above and below of YBCO layer for stabilization. Transport losses of four different stacks, single, 2 stack, 3 stack and 4 stack, were measured. Measured results were compared analytic equation suggested by Norris.

  • PDF