Development of a 20 kW pulse modulator for industrial application of pulse corona process (배가스 펄스코로나 처리공정 실험설비용 20 kW급 자기펄스압축형(MPC) 펄스 모듈레이터 개발)

  • Son, Y.G.;Jang, S.D.;Oh, J.S.;Cho, M.H.;Kim, M.H.;Han, B.W.
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1781-1783
    • /
    • 2004
  • Flue gas from fossil fuel combustion is the main source of air pollution. It is recognized that $SO_2$ and $NO_x$, (sum of NO and $NO_2$) react with $H_2O$ and $O_2$ in atmosphere and convert precursors of acid rain. Streamer corona process using pulse power is one of the effective methods to remove these gases from stack. For this, pulse generator with 160 kV of output peak voltage, 0.3 ${\mu}s$ of pulse width and 120Hz of pulse repetition rate is developed. This paper shows the pulse compression characteristics to obtain optimum parameters for basic system design.

  • PDF

The Effect of Discharge Chamber Structure on the Barrier Discharge of $CO_2$ (이산화탄소의 무성방전특성에 미치는 방전관의 구조)

  • Park, M.H.;Kwak, D.J.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.05b
    • /
    • pp.207-211
    • /
    • 2000
  • Deep Interests have been paid on the application of non-thermal plasma technique to solve the environmental pollution problems. $CO_2$ is one of the severe pollutants which cause the acid rain and global warming. In this study, in order to improve the conversion efficiency of $CO_2$, the streamer corona discharge plasma and barrier discharge plasma reactors were made, and the conversion characteristics of $CO_2$ by the corona discharge plasma and some discharge characteristics of these discharge chambers are studied experimentally.

  • PDF

Removal of NOx by Pulsed Streamer discharge (펄스 스트리머 방전을 이용한 NOx 제거)

  • 고희석;박재윤;김건호
    • Electrical & Electronic Materials
    • /
    • v.10 no.8
    • /
    • pp.807-811
    • /
    • 1997
  • In this paper we have investigated the removal characteristics of NOx by pulsed corona discharge with a multi-pointplane electrode where a magnetic field is applied in the discharge region. The efficiency of NOx removal was measured and analyzed as a function of pulse frequency gas flow rate NOx initial concentration magnetic flux density. In this result the highest removal efficiency of NOx was obtained at the following operating conditions; the frequency =400[Hz] gas flow =1[$\ell$/min] initial concentration= 400[ppm] and magnetic flux density=0.36[T].

  • PDF

절연매체로서의 $SF_{6}$가스

  • 곽영순
    • 전기의세계
    • /
    • v.29 no.6
    • /
    • pp.344-348
    • /
    • 1980
  • $SF_{6}$가스의 절연파괴특성 및 화학적특성에 관한 것을 종합해보면, 첫째, $SF_{6}$의 방전은 1개의 전자 avalanche중의 전자수가 임계치 Norit가 $10^{8}$정도에서 streamer에의 전이가 일어나므로서 이루어지며, 둘째, $SF_{6}$의 (.alpha.-.eta.)/.rho.와 E/.rho.의 관계는 .alpha.=.eta.근방에서 직선으로 상승되어 절연파괴에 극히 중요한 뜻을 가지며, 셋째, 두번째의 .alpha.=.eta.에 있어서의 구배는 보통의 기체보다 수 10배크기 때문에 최대전계를 부여하는 전극근방만이 공극의 방전개시를 지배하며, 넷째, 전기기구에 있어서 $SF_{6}$가스의 화학적변화의 energy원으로서는 arc, corona, 열을 들 수 있으며 특히 $SF_{6}$가스중과 공기중과의 내 Corona성을 구하기 위한 인가전압일내 Corona수명시간은 $SF_{6}$가스중이 공기중보다 길다는 것이다.

  • PDF

Prebreakdown Corona Discharge of Point-to-Plane Gap in $SF_6$ Gas ($SF_6$ 가스중에서 침대평판간극(針對平板間隙)의 전구(前驅)코로나 방전(放電))

  • Paek, Yong-Hyun;Lee, Bok-Hee;Jeon, Duk-Kyu
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.980-982
    • /
    • 1992
  • This paper deals with the dielectric behaviors of $SF_6$ gas and prebreakdown growth caused by lightning impulse voltages In inhomogeneous field perturbed with a fixed needle-shaped protrusion on the electrode. The measuring interpretation of the external current induced by moving charges is described. The temporal growth of prebreakdown is observed by using a shunt and photomultiplier. The prebreakdown processes are initiated by the first streamer corona at a needle protrusion, the flashover of the main gap in the positive polarity is very sensitive to the local field and propagates into the gap with the leader mechanism. It Is found that the dependence of the prebreakdown phenomena on the polarity of applied voltages is caused by the effect of space charges. In addition, the proposed measuring techniques are very useful to perform the measurements of avalanche currents, corona discharges in inhomogeneous fields and partial discharges in voids.

  • PDF

Predischarge Phenomena in Nonuniform Fields Caused by Lightning Impulse Voltages in SF(sub)6-$N_2$Mixtures (SF(sub)6-$N_2$혼합가스중에 뇌임펄스전압에 의해 형성된 불평등전장에서의 전구방전현상)

  • 이복희;이경옥;백승권
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.6
    • /
    • pp.288-295
    • /
    • 2001
  • Predischarges in nonuniform electric field stressed by lightning impulse voltagesin SF(sub)6-$N_2$mixtures are initiated by streamer coronas. Due to field ehnancement at a protrusion point of electrodes new ionization processes occur and a precursor, which leads to a first leader, is created. The leader proceeds step by step to the opposite electrode and the final jump bridges the test gap. It was found that the predischarge is propagated with a leader mechanism of stepwise expansion from the predischarge current waveforms measured by a shunt. The predischarge current is closely related to the amplitude and polarity of applied voltages, the gas pressure and the gap geometry. The time intervals between step leaders for the positive and negative polarities were inversely proportional to V.P$^2$. When the gas pressure increases in the positive polarity, statistical time lag to statistical time lag to streamer corona inception increase slightly, but the formative time lag to flashover is significantly decreased.

  • PDF

BITSE Preliminary Results

  • Bong, Su-Chan;Yang, Heesu;Lee, Jae-Ok;Kim, Yeon-Han;Cho, Kyung-Suk;Choi, Seonghwan;Baek, Ji-Hye;Park, Jongyeob;Kim, Jihun;Park, Young-Deuk;Kim, Rok-Soon;Lim, Eun-Kyung;Yashiro, Seiji;Makela, Pertti A.;Reginald, Nelson L.;Thakur, Neeharika;Gopalswamy, Natchimuthuk;Newmark, Jeffrey S.;Gong, Qian
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.46 no.1
    • /
    • pp.60.1-60.1
    • /
    • 2021
  • The Balloon-borne Investigation of Temperature and Speed of Electrons in the corona (BITSE) is a technology demonstration mission launched in 2019 to observe the solar corona from ~3 Rs to 15 Rs at four wavelengths (393.5, 405.0, 398.7, and 423.4 nm). Preliminary analysis shows that BITSE imaged the solar minimum corona with the equatorial streamers on the east and west limbs. The narrow streamers observed by BITSE are in good agreement with the geometric properties obtained by the Solar and Heliospheric Observatory (SOHO) coronagraphs in the overlapping physical domain. In spite of the small signal-to-noise ratio we were able to obtain the temperature and flow speed of the western steamer. In the heliocentric distance range 4 - 7 Rs on the western streamer, we obtained a temperature of ~ 1.0 ± 0.3 MK and a flow speed of ~ 260 km s-1 with a large uncertainty interval.

  • PDF

Fundamental Investigation Results on Ozone Generation Characteristics by Superimposed Discharge (중첩방전에 의한 오존생성 특성)

  • ;Chobei YAMABE
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.2
    • /
    • pp.91-97
    • /
    • 2003
  • In addition to its strong oxidizing power, the ozone has definite advantages over other commercial oxidants, namely, no undesirable by- products or residues are formed. With growing interest in the improvement of the ozone production in the industrial fields, many types of ozonizer using the electrical discharges have been proposed for the higher efficiency and the higher Performance at atmospheric Pressure. Among them, a superposition of different type discharges has been proposed. Especially, since the improvement for the low efficiency of dc discharge and narrow gap of surface discharge is required, a do and an at voltage are applied to same reaction space (or volume) to increase energy density at the same space. An investigation was focused on the superposition with a dc (streamer) corona and 3 surface discharge. This paper describes the investigation results on fundamental ozone generation characteristics by this superimposed discharge.

Operational Characteristics of Pilot Scale Plasma DeSOx-DeNOx System for Treatment of Coal-Fired Flue Gas (석탄연소 배가스 처리용 플라즈마 탈황탈질 시스템의 운전 특성)

  • Jang, Gil-Hong;Paek, Min-Su;Kim, Tae-Hee;Jeong, Jong-Han
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1806-1808
    • /
    • 1998
  • Tests of pilot-scale plasma DeSOx-DeNOx system using pulsed streamer corona were carried out. The system consists of the reactor with wire-plate electrodes the $30kW_{max}$. MPC type pulse generator, and $1MW_{th}$ pulverized coal combustor as a flue gas source. $NH_3$ and $C_2H_4$ were used to enhance the removal rate. The experimental result on the removal efficiency of SOx/NOx and on the effect of the additives was presented in this paper.

  • PDF

Dielectric behaviors and discharge phenomena of $SF_6$ Gas in inhomogeneous field caused by a conducting-particle (금속성 이물질에 의한 불평등전계중에서 $SF_6$ 가스의 절연특성과 방전현상)

  • 이복희;안창환;이창준;길경석;전덕규;백승권
    • Electrical & Electronic Materials
    • /
    • v.9 no.4
    • /
    • pp.385-395
    • /
    • 1996
  • 이 논문은 금속성 돌기물에 의한 불평등전계중에서의 비진동성과 진동성 임펄스전압에 의한 SF$_{6}$ 가스의 절연파괴 특성에 대해 기술하였다. 절연파괴전압-시간특성을 가스압 0.1-0.5MPa의 범위에서 정.부 극성의 전압을 인가하여 측정하였으며, 그리고 50.ohm.분류기를 통해서 전구방전 전류를 관측하였다. 가스압력에 의한 리이더 진전시간의 의존성도 측정하였다. 스트리머 코로나에 의해 발생하는 공간전하에 의한 국부전계강화는 시험갭의 전기적 절연파괴에 영향을 미치는 것으로 판명되었다. 절연파괴는 초기 스트리머 코로나로부터 발단되어, 국부전계강화에 의한 리이더진전으로 이루어진다.

  • PDF