• Title/Summary/Keyword: strain measurement sensor

Search Result 256, Processing Time 0.033 seconds

Development of a Convergence Monitoring Method for Cylindrical Structures by Optical Fiber Bragg Grating Sensor (광섬유 FBG센서를 이용한 원주형 구조물의 2차원 상대변위 모니터링기법 개발)

  • Lho, Byeong-Cheol;Kim , Jong-Woo;Kang , Suck-Hwa
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.4
    • /
    • pp.160-166
    • /
    • 2006
  • Optical Fiber Bragg Grating sensor has a good performance to measure microscopic displacement which can measure strain of lining concrete and cylindrical structure like high intensity containment building and it can present many advantages like a corrosion resistance from the durability point of view. Then it can measure plane geometrical displacement of cylindrical structures with two-way displacement FBG sensor module. According to the test result, measurement of FBG sensor is better performance than other electric sensor system and 2D-level measurement. As a test result, Resolution of the two-way displacement sensor module with FBG sensors are more 10 times than other LVDT or 2D surveying.

High-Resolution Interrogation Technique for Fiber Bragg crating Sensor Using Long-Period Fiber Grating Pair and Erbium-Doped fiber

  • Jung, Jae-Hoon;Lee, Yong-Wook;Lee, Byoung-Ho
    • Journal of the Optical Society of Korea
    • /
    • v.6 no.1
    • /
    • pp.5-12
    • /
    • 2002
  • A novel interrogation scheme to detect fine Bragg wavelength shift using a long period fiber grating pair with erbium-doped fiber inserted between the two gratings is reported. The technique is shown to feature high resolution and much more immunity to temperature perturbation compared to the conventioned Mach-Zehnder interferometer demodulation system. For quasi-static strain measurement, this approach provides high wavelength resolution of 0.05 pm that corresponds to 41.7 ne in strain and $3.8 $\times$ 10^{-3}$$^{\circ}C$ in temperature. This interrogation system is also employed in dynamic measurement to obtain the minimum detectable strain perturbation of ~ 8.76 ne/H $z^{{\frac}{1}{2}}$ at 100 Hz. Moreover, this interrogation system has prominent thermal stability. This thermal stability comes from the fact that two arms of the interferometer, the core and cladding in erbium-doped fiber, are exposed to nearly the same environment .

Numerical Study for Tunnel Shotcrete Lining Operated Stress Measurement Techique Development During a Construction (시공중 터널 숏크리트 라이닝 작용응력 측정기법 개발을 위한 수치해석적 연구)

  • Shin, Hyu-Seong;Kim, Dong-Gyou;Jung, Yong-Su;Hwang, Jae-Hong;Bae, Gyu-Jin
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.03a
    • /
    • pp.754-761
    • /
    • 2008
  • In general, stress measurement of existent shotcrete lining be used by pressure cells. but, measuring instrument is lost by high pressure at shotcrete lining construction and pressure cell's measurement value have to low believability by natural conditions like curing temperature. In this study, proposed techniques to measure without utilizing sensitive stress sensor in natural condition at point that want stress of shotcrete lining after shotcrete lining construction. Executed numerical analysis to forecast stress level that interact in tunnel shotcrete lining, measured strain of hole by load action through hole in shotcrete lining. 3D FEM(finite element method) is enforced through various parameters curing time of shotcrete lining, thickness, load condition. Different model cases applied by parametic study. As analysis result, it could grasp development possibility of method that propose this time because it could examine corelation with strain by near hole of shotcrete lining and stress about load condition.

  • PDF

Highly-birefringent Photonic Crystal Fiber with Squeezed Lattice for Strain, Curvature and Temperature Sensing (큰 복굴절 특성을 가지는 광자결정 광섬유를 이용한 스트레인, 구부림 및 온도 특성)

  • Eom, Sung-Hoon;Kim, Gil-Hwan;Hwang, Hyu-Jin;Ma, Kyung-Sik;Lee, Kwan-Il;Jeong, Je-Myung;Lee, Sang-Bae
    • Korean Journal of Optics and Photonics
    • /
    • v.21 no.6
    • /
    • pp.230-234
    • /
    • 2010
  • Highly-Birefringent Photonic Crystal Fiber (Hi-Bi PCF) is composed of a single material, silica, so that its temperature sensitivity is extremely low. Therefore, we propose afiber based Sagnac interferometer for measurement of strain and curvature independent of temperature variation. The sensitivities of strain and curvature (both axes) are measured to be $1.41\;pm/{\mu}{\varepsilon}$ and $0.93nm/m^{-1}$(slow axis Y), $-1.6\;nm/m^{-1}$(fast axis X), respectively.

FBG Sensor Signal Processing System using SLD Tunable Light Source and Etalon Filter (SLD동조 광원과 에탈론 필터를 이용한 FBG 센서 신호처리 시스템)

  • Chung, Chul;Lee, Ho-Joon;Kim, Ki-Soo
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.3
    • /
    • pp.39-44
    • /
    • 2004
  • Fiber Bragg grating sensors are fabricated by core index modulation using UV laser and phasemask. Bragg wavelength of the grating is changed by the external strain. In this paper, a signal processing system of fiber Bragg grating sensor has studied in the optical wavelength domain. The system is based on the sweep semiconductor light source that consists of SLD, F-P tunable filter and etalon filter. The hysteresis effects of PZT in the F-P tunable filter are compensated. The long term measurement stability is obtained by controlling the temperature of F-P tunable filter and the SLD. We compare the strain data from fiber Bragg grating sensor and that from strain gauge at concrete hume pipe. We also get very good results for the long gauge displacement using fiber Bragg grating sensor which are identical to the data with short gauge length ordinary displacement sensor.

Sensitivity of BOD Sensor with Heavy Metal Tolerant Serratia marcescens LSY4 (Serratia marcescens LSY4 중금속 내성주를 이용한 BOD센서의 감응도)

  • Kim Mal-Nam;Lee Sun-Young
    • Korean Journal of Environmental Biology
    • /
    • v.22 no.3
    • /
    • pp.394-399
    • /
    • 2004
  • A BOD sensor was prepared with S. marcescens LSY4 and was applied for measurement of BOD values of a solution containing the standard organic pollutants. The sensor sensitivity was nearly independent of the culture time in the range of 9-16 hours. It was also affected little by the cell mass in the range of 0.22-0.75 mg $cm^{-2}$. A cyclic change in the solution pH in the range of 4-9 was accompanied by a reversible variation in the sensor sensitivity. However, the reversibility was lost when the solution pH became more acidic or more basic. Heavy metal ions lowered the sensor sensitivity, which took place more precipitously in the presence of $Cu^{2+}$ and $Ag^+$ rather than in the presence of $Zn^{2+}$ and $Cd^{2+}$. The reduction of the sensor sensitivity was significantly attenuated by loading heavy metal ion tolerance induced strain. The $Cu^{2+}$tolerance induced strain was more efficient for the attenuation than $Zn^{2+}$ and $Cd^{2+}$ tolerance induced strain.

Analysis of the axial force in CWR connected with turnout by means of the field measurement (현장계측을 통한 교량상 분기기 축력 분석에 관한 연구)

  • Choi, Jin-Yu;Kim, In-Jae;Hwang, Sung-Ho;Yang, Shin-Chu
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.1289-1292
    • /
    • 2006
  • The demand on a turnout layed on a bridge is rising owing to the increasing number of stations on the viaduct. And also the demand on a turnout with CWR is rising to upgrade running speed of the passing train. A CWR connected with turnout is subjected to additional axial force induced by the actions due to change in temperature, braking and starting force, and bending of the deck. But magnitude and distribution of the axial force in rails of turnout is not clear yet. So, in this study, a field measurement was conducted to know them. The strain gage method was adopted for field test. The FBG sensor for the strain measurement was used to ensure stability of test value and durability of gage for long term. It is expected that we can get data on the axial force in rail connected with turnout with respect to seasonal temperature change by the established field test system.

  • PDF

REINFORCING EFFECTS OF MICRO-PILES (억지말뚝의 억제효과)

  • Jung, Sung-Yun;Chang, Ki-Tae;Han, Heui-Soo
    • Journal of the Korean Geophysical Society
    • /
    • v.7 no.4
    • /
    • pp.305-311
    • /
    • 2004
  • Several sensor systems are used to estimate the reinforceing effect of pile in hihg cut slopes, and to find a failure zone in slopes effectively. Inclinometer, extensometer and V/W sensor have shown a great potentiality to serve real time health monitoring of the slope structures. They were embedded or attached to the structures, we conducted field tests and test results have shown great solutions for sensor systems of Civil Engineering Smart Structures. This research is to seek for the relationships among the slope movement and the reinforceing effect of pile, and the strain distribution in a active zone by analyzing the data from the in-situ measurement so that the possible failure zone should be well defined based on the relationships. Also, the relationships between temperature and reinforceing effect of pile, and the strain distribution are estimated in this paper.

  • PDF

Experimental validation of Kalman filter-based strain estimation in structures subjected to non-zero mean input

  • Palanisamy, Rajendra P.;Cho, Soojin;Kim, Hyunjun;Sim, Sung-Han
    • Smart Structures and Systems
    • /
    • v.15 no.2
    • /
    • pp.489-503
    • /
    • 2015
  • Response estimation at unmeasured locations using the limited number of measurements is an attractive topic in the field of structural health monitoring (SHM). Because of increasing complexity and size of civil engineering structures, measuring all structural responses from the entire body is intractable for the SHM purpose; the response estimation can be an effective and practical alternative. This paper investigates a response estimation technique based on the Kalman state estimator to combine multi-sensor data under non-zero mean input excitations. The Kalman state estimator, constructed based on the finite element (FE) model of a structure, can efficiently fuse different types of data of acceleration, strain, and tilt responses, minimizing the intrinsic measurement noise. This study focuses on the effects of (a) FE model error and (b) combinations of multi-sensor data on the estimation accuracy in the case of non-zero mean input excitations. The FE model error is purposefully introduced for more realistic performance evaluation of the response estimation using the Kalman state estimator. In addition, four types of measurement combinations are explored in the response estimation: strain only, acceleration only, acceleration and strain, and acceleration and tilt. The performance of the response estimation approach is verified by numerical and experimental tests on a simply-supported beam, showing that it can successfully estimate strain responses at unmeasured locations with the highest performance in the combination of acceleration and tilt.

Study on the Pressure Measurement at Parting Surface to Prevent Flashing in Injection Molds (사출금형 버 발생 방지를 위한 형합면압 측정에 관한 연구)

  • Choi, J.H.;Choi, S.H.;Tae, J.S.;Park, H.P.;Rhee, B.O.
    • Transactions of Materials Processing
    • /
    • v.20 no.1
    • /
    • pp.73-78
    • /
    • 2011
  • The flashing reduces the part quality and the productivity of the molding process. We developed a contact pressure sensor to detect the flashing immediately. The performance of the sensor was analyzed in a simple 2D simulation. The sensor was applied to an automotive bumper mold with cavity pressure sensors. It showed sensitive output signal for the mold response by the cavity pressure change. It was confirmed that the flashing at the gate area occurred in the filling stage by the pressure increase due to growth of the melt flow length. The sensor output was correlated with the cavity pressure sensor output.