• Title/Summary/Keyword: stepping motor

Search Result 296, Processing Time 0.025 seconds

Efficacy of PNF Group Exercise Program in Chronic Stroke (만성 뇌졸중 환자에 대한 PNF 집단 운동프로그램의 효과)

  • Kim, Soo-Min;Bae, Sung-Soo
    • PNF and Movement
    • /
    • v.3 no.1
    • /
    • pp.1-15
    • /
    • 2005
  • Objective : The purpose of this study was to evaluate the influence of a community based group exercise intervention on motor functional capacity. To evaluate the immediate(post-treatment) effects after 6-weeks exercise program on the group exercise intervention(PNF and Circuit exercise). Methods : Subjects-Included persons with stroke who were living in the community. Thirty-seven subjects were randomly assigned to the PNF, Circuit exercise and control group participated in a repeated measures design that evaluated the subjects with pre-treatment, post-treatment(6 weeks). Functional ability outcome measures assessed the motor assessment scale(MAS) and EMG. Both treatment groups participated in exercise cJass three times a week for 6 weeks. Group programs focused on balance, functional motor capacity and walking ability. The PNF program was modified PNF pattem and techniques with emphasis on functional tasks when possible, as well as stretching of the more affected limb particularly in the more affected shoulder. The Circuit program with subjects completing practice at a selies of work station as well as participating in walking races and relay with other members of the group. Results : Compared with the control group, the treatment group had larger improvements in the motor function ability after 6 weeks treatment and Post-treatment test scores were more significant than the pre-treatment score. 1. Motor function were assessed by using MAS, sit to stand, walking and upper function were assessed pre-treatment versus post-treatment measures revealed a statically significant(p<.05). There were significant differences between the groups. Compared with the control group, the treatment group had larger improvements. 2. In the treatment groups, demonstrated difference in the electromyographic activation of biceps, triceps, quadriceps and tibialis anterior muscles on the paretic side in the response to the reaching arm movement and stepping motion in stance. The difference in muscle activation improvement were not statically significant. Conclusion : The results of this study showed that the PNF and Circuit group exercise intervention can improve motor functional ability. This study suggests that the PNF and Circuit exercise programs is appropriate for community-based group exercise principles. It leads to gain and maintain potential function for disabled persons after stroke in the community.

  • PDF

The Mechanical Antiallodynic Effect of Intrathecal Lamotrigine in Rats with Spinal Nerve Ligation (척추신경결찰 흰쥐에서 척수강내로 투여한 Lamotrigine의 기계적 항이질통 효과)

  • Song, Jun Gol;Jun, In Gu;Kwon, Mi Young;Park, Jong Yeon
    • The Korean Journal of Pain
    • /
    • v.18 no.2
    • /
    • pp.118-123
    • /
    • 2005
  • Background: A nerve ligation injury may produce a tactile allodynia. The effects of intrathecally delivered lamotrigine on allodynia induced due to fifth and sixth lumbar spinal nerves ligation in rats, using lumbar intrathecal catheters were examined. Methods: Sprague-Dawley rats (body weight 160-180 g) were prepared by tightly ligating the fifth and sixth left lumbar spinal nerves, with the implantation of a chronic intrathecal catheter for drug administration. Mechanical allodynia and allodynic threshold were measured using von Frey filaments and the updown method, respectively. After the baseline hind paw withdrawal thresholds had been obtained, lamotrigine (10, 30, 100 and $300{\mu}g$) was administered intrathecally. Thereafter, the dose-response curves and 50% effective dose ($ED_{50}$) were obtained. Motor dysfunction was assessed by observing the righting/stepping reflex responses and abnormal weight bearing. Results: Intrathecal administration of lamotrigine produced a dose-dependent antiallodynic action ($ED_{50}=61.7{\mu}g$). Mild motor weakness was observed with $300{\mu}g$ lamotrigine, but no severe motor impairment was found. Conclusions: It is suggested that intrathecal lamotrigine could produce moderate antagonism of mechanical allodynia at the spinal level in a rat neuropathic pain model with minimal motor weakness.

Effect of Contruals on Social Action Perception: Modulation of Motor Resonance Effect by Perspectives (사회적 행위 지각에 있어 해석 효과: 관점에 따른 운동공명효과의 조절)

  • Lee, Dong-Hoon;Shin, Cheon-Woo;Shin, Hyun-Jung
    • Korean Journal of Cognitive Science
    • /
    • v.23 no.1
    • /
    • pp.109-132
    • /
    • 2012
  • According to recent embodied cognition approach, understanding of actions is not based on abstract symbolic process but based on mental simulation of sensory-motor information related to those actions. As supporting evidence, motor resonance effect is a facilitation/interference effect of motor response in terms of similarity between observed action and concurrent own action. In the current research, we investigated this effect in the situation to perceive a complex social action perception and how it would be modulated by perspectives of construals of the social action scene. For this purpose, we created three kinds of fighting action scenes of two people in terms of body actions of the subject(ie., hitting, stepping, biting), and described them in two perspectives; active and passive. During the experiment, subjects had to verify the congruency of the picture and the description first, and if they are congruent, they had to do two different actions in terms of color of following cues. In the first experiment, subjects' response time for stepping on a pedal and pressing a button were analyzed for measuring motor resonance effect for the foot movement. In the second experiment, voice response time with a microphone and button pressing time were analyzed for the mouth movement motor resonance effect. Results showed the facilitation of the foot movement(in Exp1), and the mouth movement(in Exp2) only when the action scene was described in active perspective. Our results indicate that the motor resonance effect can be occurred during perception of social actions in the real life situation, but it can be also modulated by the perspective of the mental construal of the action event.

  • PDF

Automatic Punching System for FPC using Machine Vision (비전 기반의 FPC용 자동 펀칭시스템)

  • Lee Young-Choon;Lee Seong-Cheol
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.12 s.177
    • /
    • pp.77-86
    • /
    • 2005
  • This paper is about the development of Automatic FPC(flexible printed circuit) punching instrument for the improvement of working condition and cost saving. FPC is used to detect the contact position of keyboard and button like a cellular phone. Depending on the quality of the printed ink and position of reference punching point to the FPC, the resistance and current are varied to the malfunctioning values. The size of reference punching point is 2mm and the above. Because the punching operation is done manually, The punching accuracy is varied with operator's condition. Recently, The punching accuracy has deteriorated severely to the 2mm punching reference hall so that assembly of the K/B has hardly done. To improve this manual punching operation to the FPC, automatic FPC punching system is introduced. Precise mechanical parts like a 5-step stepping motor and ball screw mechanism are designed and tested and low cost PC camera is used fur the sake of cost down instead of using high quality vision systems for the factory automation. Test algorithms and programs showed good results to the designed automatic punching system and led to the increasement of productivity and huge cost down to law material like FPC by avoiding bad quality.

Study on Accuracy Evaluation of Laser Lens Changer for a Laser-Assisted Machining System (레이저보조가공에서 레이저 렌즈 교환장치의 정밀도 평가에 관한 연구)

  • Oh, Won-Jung;Kim, Eun-Joong;Lee, Choon-Man
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.32 no.8
    • /
    • pp.687-692
    • /
    • 2015
  • LAM (Laser-Assisted Machining) is an effective method for processing difficult-to-cut workpieces. The focal length of a LAM system is changed by the change of the workpiece shape during laser preheating; this problem is solved by changing the lens of the laser module. Linear- and rotary-type lens changers were developed to change the laser lens of a LAM system. The linear-type lens changer is operated by a motor with a ball-screw, and the rotary type is operated by a stepping motor. The natural frequency and structural stability of the laser lens changers were confirmed by using a finite element analysis; in addition, the functions of the lens changers were verified by measuring the iterative accuracy. The measured results show that the rotary-type lens changer is more accurate than the linear-type changer.

Survey of Nonlinear Control Methods to Permanent Magnet Stepping Motors (스테퍼 모터를 위한 비선형 제어기법의 개관)

  • Kim, Wonhee;Shin, Donghoon;Lee, Youngwoo;Chung, Chung Choo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.20 no.3
    • /
    • pp.323-332
    • /
    • 2014
  • Stepper motor is widely used in positioning applications due to its durability and high torque to inertia ratio as well as low cost and ability to be easily controlled with open-loop. Due to increased resolution of position control and improved stability of motion control, microstepping has drawn attention in industry since it was introduced in 1970s. With the increase in computational power and decrease in cost of embedded processors in recent years, drives and control systems for stepper motors have become more sophisticate than ever. Thus, closed-loop control methods have been developed to improve the performance of the stepper motors. In this paper, we review not only basic principles of conventional control methods used for stepper motors but also that of microstepping control. In addition, we surveyed recent development in nonlinear control methods applied to stepper motors. The nonlinear control methods are presented in the view of Lyapunov stability. Nonlinear torque disturbance observer, sliding mode control, and nonlinear phase compensation are also presented.

Flow Rate Control of Gaseous Oxygen for a $HTPB/GO_2$ Hybrid Rocket ($HTPB/GO_2$ 하이브리드 로켓의 산화제 유량제어)

  • Oh Hwa-Young;Moon Sung-Hwan;Huh Hwanil
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.10a
    • /
    • pp.251-254
    • /
    • 2004
  • Hybrid rockets have many advantages over solid and liquid rockets. Hybrid rockets put forth high $I_{sp}$ like liquid rockets in spite of simple structure and low cost. As oxidizer flow rate is increased, thrust of hybrid rocket is increased accordingly. In this study, lab-scale hybrid rocket is designed, fabricated and tested. This system consists of lab-scale hybrid rocket motor, ignition system, flow system and data aquisition system. In order to control oxidizer flow rate, we construct flow rate control system by using needle valve and stepping motor.

  • PDF

Design and Fabrication of Tool Change Multi-nozzle FDM 3D Printer (툴 체인지 방식 멀티 노즐 3D프린터의 설계 및 제작)

  • Suk, Ik-hyun;Park, Jong-kyu
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.2
    • /
    • pp.38-44
    • /
    • 2021
  • To cater to the transition from single-color to multicolor/multi-material printing, this paper proposes a cartridge-replacing type multi-nozzle Fused Depositon Modeling(FDM) three-dimensional (3D) printer. In the test printing run, tool change failure/wobble/layer shift occurred. It was confirmed that improper support was the cause of this tool change failure. As a solution, spline and electromagnetic cartridges were designed. Wobble was caused by machine vibration and the motor stepping out. To minimize wobble, an additional Z-axis was installed, and the four-point bed leveling method was used instead of the three-point bed leveling method. The occurrence of layer shift was ascribed to the eccentricity of the Z-axis lead screw. Therefore, slit coupler was replaced with an Oldham type. In addition to the mechanical supplementation, the control environment was integrated to prevent accidents and signal errors due to wire connections. Before the final test printing run, a rectifier circuit was added to the motor to secure precise control stability. The final test printing run confirmed that the wobble/layer shift phenomenon was minimized, and the maximum error between layers was reduced to 0.05.

Exploration of Neurophysiological Mechanisms underlying Action Performance Changes caused by Semantic Congruency between Perceived Action Verbs and Current Actions (지각된 행위동사와 현재 행위의 의미 일치성에 따른 행위 수행 변화의 신경생리학적 기전 탐색)

  • Rha, Younghyoun;Jeong, Myung Yung;Kwak, Jarang;Lee, Donghoon
    • Korean Journal of Cognitive Science
    • /
    • v.27 no.4
    • /
    • pp.573-597
    • /
    • 2016
  • Recent fMRI and EEG research for neural representations of action concepts insist that processing of action concepts evoke the simulation of sensory-motor information. Moreover, there are several behavioral studies showing that understanding of action verbs or sentences describing actions interfere or facilitate current action performance. However, it is unclear that online interaction between processing of action concepts and current action is based on the simulation of sensory-motor information, or other neural mechanisms. The present research aims to explore the underlying neural mechanism that how the perception of action language influence the performance of current action using high-spacial temporal resolution EEG and multiple source analysis techniques. For this, participants were asked to perform a cued-motor reaction task in which button-pressing hand action and pedal-stepping foot action were required according to the color of the cue, and we presented auditorily action verbs describing the responding actions (i.e., /press/, /step/, /stop/) just before the color cue and examined the interaction effect from the semantic congruency between the action verbs and the current action. Behavioral results revealed consistently a facilitatory effect when action verbs and responding actions were semantically congruent in both button-pressing and pedal-stepping actions, and an inhibitory effect when semantically incongruent in the button-pressing action condition. In the results of EEG source waveform analysis, the semantic congruency effects between action verbs and the responding actions were observed in the Wernicke's area during the perception of action verbs, in the anterior cingulate gyrus and the supplementary motor area (SMA) at the time when the motor-cue was presented, and in the SMA and primary motor cortex (M1) during action execution stage. Based on the current findings, we argue that perceived action verbs evoke the facilitation/inhibition effect by influencing the expectation and preparation stage of following actions rather than the directly activating the particular motor cortex. Finally we discussed the implication on the neural representation of action concepts and methodological limitations of the current research.

Development of a Test Strip Reader for a Lateral Flow Membrane-based Immunochromatographic Assay

  • Park, Je-Kyun;Kim, Suhyeon
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.9 no.2
    • /
    • pp.127-131
    • /
    • 2004
  • A low-cost, simple strip reader system using a linear movement mechanism of CD-ROM deck has been developed to characterize a lateral flow membrane-based immunochromatographic assay. The test strip reader was assembled by a CD-ROM deck and home-made optical head especially designed for immunoassays. The optical head for detecting reflected light from the test strip surface consists of green light-emitting diode, large area silicon photodiode, and anodized aluminum mounting block providing a slit structure for cutting light from the LED. The stepping motor of the deck was operated in the full step mode, whose distance of each reading point is about 0.15mm. The performance of the strip reader was tested by analysis of HBV(hepatitis B virus) antigen test kit. This strip reader can be useful for inexpensive, disposable, and membrane-based assays that provide visual evidence of the presence of an analyte in a liquid sample.