• Title/Summary/Keyword: state variable

Search Result 1,630, Processing Time 0.033 seconds

Subband Affine Projection Adaptive Filter using Variable Step Size and Pipeline Transform (가변 적응상수와 파이프라인 변환을 이용한 부밴드 인접투사 적응필터)

  • Choi, Hun;Ha, Hong-Gon;Bae, Hyeon-Deok
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.46 no.1
    • /
    • pp.104-110
    • /
    • 2009
  • In this paper, we suggest a new technique which employ the pipelined architecture for the implementation of the SAP adaptive filter using variable step size. According as SAP adaptive filter is sufficiently decomposed, a simplified SAP adaptive filter can be derived, and the weights of adaptive sub-filters can be updated by a simple formular without a matrix inversion. The convergence speed and the steady state error of the simplified SAP adaptive filter are improved by using variable step size. For practical implementation, the simplified SAP adaptive sub-filters are transformed by the pipeline technique.

DC Motor Speed Control by Variable Structure PI Control (가변 구조 PI 제어에 의한 직류 전동기의 속도제어)

  • Lee, Sung-Bak;Lee, Jong-Kyu;Won, Young-Jin;Han, Wan-Oak;Cho, Joon-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.1225-1227
    • /
    • 1992
  • This paper presents a study on the variable structure PI(proportional and integrate) control which is insensible to the variation of parameters or external disturbance for driving DC motor. In the presented variable structure PI control (VSPIC), the sliding mode control was used at the below of 4000 rpm and PI control also used at the above of 4000 rpm with no load. In other way, the PI control was used at the below of 4000 rpm and the sliding mode control at the above of 4000 rpm with some loading, and then the output waveform following the variation of load was measured. intel 8031 microcomputer unit and IBM PC was combined to form the full system and the speed control was performed with it. The experimental result of the fast response to speed was more improve than it was open loop state. For load varing, the sliding mode insensible to external disturbance was applied and the improved response was obtained.

  • PDF

An Efficient String Similarity Search Technique based on Generating Inverted Lists of Variable-Length Grams (가변길이 그램의 역리스트 생성을 이용한 효율적인 유사 문자열 검색 기법)

  • Kim, Jongik
    • Journal of KIISE
    • /
    • v.43 no.11
    • /
    • pp.1275-1280
    • /
    • 2016
  • Existing techniques for string similarity search first generate a set of candidate strings and then verify the candidates. The efficiency of string similarity search is highly dependent on candidate generation methods. State of the art techniques select fixed length q-grams from a query string and generate candidates using inverted lists of the selected q-grams. In this paper, we propose a technique to generate candidates using variable length grams of a query string and develop a dynamic programming algorithm that selects an optimal combination of variable length grams from a query string. Experimental results show that the proposed technique improves the performance of string similarity search compared with the existing techniques.

Performance Analysis of Cal1 Arrival History-Based Location Update Algorithm (호도착기록에 기반한 위치갱신 알고리즘의 성능 분석)

  • Lee, Jong-Min;Kwon, Bo-seob;Maeng, Seung-Ryoul
    • The KIPS Transactions:PartA
    • /
    • v.10A no.4
    • /
    • pp.381-388
    • /
    • 2003
  • Location tracking is used to keep track of the location information of a mobile terminal in an idle state for a cail setup between mobile terminals. In this paper, we introduce a location update algorithm based on the call arrival history, which is appropriate for a variable call arrival rate over time. The location tracking strategy which uses the proposed algorithm can find changes in the call arrival rate by maintaining a call arrival history of a mobile terminal, from which a mobile terminal can calculate an appropriate timeout interval for a variable call arrival rate. We show that the proposed scheme is appropriate for a variable call arrival rate by presenting a simple analytical model and analytical results to investigate its performance for both a fixed and a variable call arrival rate.

A Variable Modulus Algorithm using Sigmoid Nonlinearity with Variable Variance (가변 분산을 갖는 시그모이드 비선형성을 이용한 가변 모듈러스 알고리즘)

  • Kim Chul-Min;Choi Ik-Hyun;Oh Kil-Nam
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2005.11a
    • /
    • pp.649-653
    • /
    • 2005
  • To estimate for an error signal with sigmoid nonlinearity what reduced constellation applies closed eye pattern in the initial equalization, there can be improves problems of previous soft decision-directed algorithm that increasing estimate complexity and decreasing of convergence speed when substitute high-order constellation. The characteristic of sigmoid function is adjusted by a mean and a variance parameter, so it depends on adjustment of variance that what reduced constellation $values(\gamma)$ can have ranges between + $\gamma$ and - $\gamma$. In this paper, we proposed Variable Modulus Algorithm (VMA) that can be improving a performance of steady-state by adjustment of variance when equalization works normally and each cluster of constellation decrease.

  • PDF

An algebraic step size least mean fourth algorithm for acoustic communication channel estimation (음향 통신 채널 추정기를 이용한 대수학적 스텝크기 least mean fourth 알고리즘)

  • Lim, Jun-Seok
    • The Journal of the Acoustical Society of Korea
    • /
    • v.35 no.1
    • /
    • pp.55-62
    • /
    • 2016
  • The least-mean fourth (LMF) algorithm is well known for its fast convergence and low steady-state error especially in non-Gaussian noise environments. Recently, there has been increasing interest in the least mean square (LMS) algorithms with variable step size. It is because the variable step-size LMS algorithms have shown to outperform the conventional fixed step-size LMS in the various situations. In this paper, a variable step-size LMF algorithm is proposed, which adopts an algebraic optimal step size as a variable step size. It is expected that the proposed algorithm also outperforms the conventional fixed step-size LMF. The superiority of the proposed algorithm is confirmed by the simulations in the time invariant and time variant channels.

Map-based Variable Rate Application of Nitrogen Using a Multi-Spectral Image Sensor (멀티스펙트랄 이미지 센서를 이용한 전자 지도 기반 변량 질소 살포)

  • Noh, Hyun-Kwon;Zhang, Qin
    • Journal of Biosystems Engineering
    • /
    • v.35 no.2
    • /
    • pp.132-137
    • /
    • 2010
  • Site-specific N application for corn is one of the precision crop management. To implement the site-specific N application, various nitrogen stress sensing methods, including aerial image, tissue analysis, soil sampling analysis, and SPAD meter readings, have been used. Use of side-dressing, an efficient nitrogen application method than a uniform application in either late fall or early spring, relies mainly on the capability of nitrogen deficiency detection. This paper presents map-based variable rate nitrogen application based using a multi-spectral corn nitrogen deficiency(CND) sensor. This sensor assess the nitrogen stress by means of the estimated SPAD reading calculated from the corn leave reflectance. The estimated SPAD value from the CND sensor system and location information form DGPS of each field block was combined into the field map using a ArcView program. Then this map was converted into a raster file for a map-based variable rate application software. The relative SPAD (RSPAD = SPAD over reference SPAD) was investigated 2 weeks after the treatments. The results showed that the map-based variable rate application system was feasible.

Development of Variable Duty Cycle Control Method for Air Conditioner using Artificial Neural Networks (신경회로망을 이용한 에어컨의 가변주기제어 방법론 개발)

  • Kim, Hyeong-Jung;Doo, Seog-Bae;Shin, Joong-Rin;Park, Jong-Bae
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.10
    • /
    • pp.399-409
    • /
    • 2006
  • This paper presents a novel method for satisfying the thermal comfort of indoor environment and reducing the summer peak demand power by minimizing the power consumption for an Air-conditioner within a space. Korea Electric Power Corporation (KEPCO) use the fixed duty cycle control method regardless of the indoor thermal environment. However, this method has disadvantages that energy saving depends on the set-point value of the Air-Conditioner and direct load control (DLC) has no net effects on Air-conditioners if the appliance has a lower operating cycle than the fixed duty cycle. In this paper, the variable duty cycle control method is proposed in order to compensate the weakness of conventional fixed duty cycle control method and improve the satisfaction of residents and the reduction of peak demand. The proposed method estimates the predict mean vote (PMV) at the next step with predicted temperature and humidity using the back propagation neural network model. It is possible to reduce the energy consumption by maintaining the Air-conditioner's OFF state when the PMV lies in the thermal comfort range. To verify the effectiveness of the proposed variable duty cycle control method, the case study is performed using the historical data on Sep. 7th, 2001 acquired at a classroom in Seoul and the obtained results are compared with the fixed duty cycle control method.

Functionally upgraded passive devices for seismic response reduction

  • Chen, Genda;Lu, Lyan-Ywan
    • Smart Structures and Systems
    • /
    • v.4 no.6
    • /
    • pp.741-757
    • /
    • 2008
  • The research field of structural control has evolved from the development of passive devices since 1970s, through the intensive investigation on active systems in 1980s, to the recent studies of semi-active control systems in 1990s. Currently semi-active control is considered most promising in civil engineering applications. However, actual implementation of semi-active devices is still limited due mainly to their system maintenance and associated long-term reliability as a result of power requirement. In this paper, the concept of functionally upgraded passive devices is introduced to streamline some of the state-of-the-art researches and guide the development of new passive devices that can mimic the function of their corresponding semi-active control devices for various applications. The general characteristics of this special group of passive devices are discussed and representative examples are summarized. Their superior performances are illustrated with cyclic and shake table tests of two example devices: mass-variable tuned liquid damper and friction-pendulum bearing with a variable sliding surface curvature.

The Generator Excitation Control Based on the Quasi-sliding Mode Pseudo-variable Structure Control

  • Hu, Jian;Fu, Lijun
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.4
    • /
    • pp.1474-1482
    • /
    • 2018
  • As an essential means of generator voltage regulation, excitation control plays an important role in controlling the stability of the power system. Therefore, the reasonable design of an excitation controller can help improve the system stability. In order to raise the robustness of the generator exciting system under outside interference and parametric perturbation and eliminate chattering in the sliding mode control, this paper presents a generator excitation control based on the quasi-sliding mode pseudo-variable structure control. A mathematical model of the synchronous generator is established by selecting its power, speed and voltage deviation as state variables. Then, according to the existing conditions of the quasi-sliding mode, a quasi-sliding mode pseudo-variable structure controller is designed, and the parameters of the controller are obtained with the method of pole configuration. Simulations show that compared with the existing methods, the proposed method is not only useful for accurate voltage regulation, but also beneficial to improving the robustness of the system at a time when perturbance happens in the system.