• 제목/요약/키워드: state monitoring

검색결과 1,595건 처리시간 0.032초

마이크로 엔드밀링에서 음향방출 신호를 이용한 상태감시 (State Monitoring using AE Signal in Micro Endmilling)

  • 정연식;강익수;김전하;강명창;김정석;안중환
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2004년도 추계학술대회 논문집
    • /
    • pp.334-339
    • /
    • 2004
  • Ultraprecision machining and MEMS technology have been taken more and more important position in machining of microparts. Micro endmilling is one of the prominent technology that has wide spectrum of application field ranging from macro parts to micro products. Also, the method of micro-grooving using micro endmilling is used widely owing to many merit, but has problems of precision and quality of products due to tool wear and tool fracture. This investigation deals with state monitoring using acoustic emission(AE) signal in the micro-grooving. Characteristic evaluation of AE raw signal, AE hit and frequency analysis for state monitoring is also presented in the paper.

  • PDF

주축 상태 모니터링 용 광파이버 변위센서 제작 및 성능평가 (Fabrication and Performances Tests of the Optical Fiber Position Sensor for Application to Spindle State Monitoring)

  • 신우철;홍준희;박찬규
    • 한국공작기계학회논문집
    • /
    • 제14권6호
    • /
    • pp.37-44
    • /
    • 2005
  • This paper presents fabrication techniques of the optical fiber position sensor (or spindle state monitoring. These include selection of components such as optical fibers, a laser-diode, a photo-diode, and op-amp IC of the signal process circuit. We also describe electric runout problem. The fabricated sensor has a linearity of $1.7\%$ FSO in the air gap range $0.1\~0.6mm$, a resolution of $0.37{\mu}m$ and a bandwidth of 6.3kHz. Finally, we have successfully operated a magnetic bearing spindle system using the sensors.

보조회로에 의한 인버터 상태 감시 (State monitoring of inverter using auxiliary circuit)

  • 백주원;이병국;김태진;최영길;김광화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.1099-1101
    • /
    • 2003
  • The diagnosis of power converter using auxiliary circuit connected to output terminal is proposed and verified by experimental results in this paper. On contrary to conventional diagnosis method, the proposed monitoring technique is possible to measure the state of power converter and unbalanced output caused by a misfiring of switch and unusual control signal. Conventional method gives a monitoring approaches for only a unusual operation of power converter. In this paper, three signals with auxiliary circuit are obtained and analyzed to see the state of electrolytic capacitor, power semiconductor switches and output voltage balance. 2kVA inverter is made and fisted to verify the proposed circuit.

  • PDF

가정용 전력 모니터링 시스템 및 장치식별 알고리즘 개발 (Development of Home Electrical Power Monitoring System and Device Identification Algorithm)

  • 박성욱;서진수;왕보현
    • 한국지능시스템학회논문지
    • /
    • 제21권4호
    • /
    • pp.407-413
    • /
    • 2011
  • 본 연구에서는 가정용 전력 모니터링 시스템을 구현하고 실험가구에 적용하여 평가하였으며, 평가과정에서 확보한 기기별 전력 사용 패턴 정보를 이용하여 자동 기기 식별 알고리즘을 개발하였다. 실험가구에 적용해본 결과, 기기별 전력사용 정보와 월별 예상 사용량 정보가 전력 소비 절감에 도움이 된다는 응답을 얻을 수 있었다. 그리고 시스템을 보다 편리하게 사용하기 위해서는 설치의 편의성과 UI를 개선해야한다는 응답을 얻었다. 본 연구에서는 UI 개선을 위하여 일반냉장고, TV, 전기밥솥, 김치냉장고, 세탁기를 자동으로 식별하는 알고리즘을 구현하였다. 자동 장치 식별 알고리즘은 전력 모니터링 과정에서 수집한 전력 소비 패턴을 관찰하여 Zero-Crossing Rate(ZC), Variation of On State(VO), Slope of On State(SO), Duty Cycle(DC) 등 4가지 특징을 규정하여 이용하였으며, 특징을 적용하는 시간 구간은 기기가 동작하는 시간이 25% 이상이 되는 2시간 길이의 구간을 이용하였다. 제안된 알고리즘은 테스트 set에 동일한 기기를 포함하는 경우 82.1%의 성능을 얻을 수 있었다.

Real-Time Monitoring and Analysis of Power Systems with Synchronized Phasor Measurements

  • Kim, Hong-Rae
    • 조명전기설비학회논문지
    • /
    • 제21권9호
    • /
    • pp.101-108
    • /
    • 2007
  • State estimators are used to monitor the operating states of power systems in modern EMS. It iteratively calculates the voltage profile of the currently operating power system with voltage, current, and power measurements gathered from the entire system. All the measurements are usually assumed to be obtained simultaneously. It is practically impossible, however, to maintain the synchronism of the measurement data. Recently, phasor measurements synchronized via satellite are used for the operation of these power systems. This paper describes the modified state estimator used to support the processing of synchronized phasor measurements. Synchronized phasor measurements are found to provide synchronism of measurement data and improve the accuracy/redundancy of the measurement data for state estimation. The details of the developed state estimation program and some numerical results of operation are presented.

CONDITION MONITORING USING EMPIRICAL MODELS: TECHNICAL REVIEW AND PROSPECTS FOR NUCLEAR APPLICATIONS

  • Heo, Gyun-Young
    • Nuclear Engineering and Technology
    • /
    • 제40권1호
    • /
    • pp.49-68
    • /
    • 2008
  • The purpose of this paper is to extensively review the condition monitoring (CM) techniques using empirical models in an effort to reduce or eliminate unexpected downtimes in general industry, and to illustrate the feasibility of applying them to the nuclear industry. CM provides on-time warnings of system states to enable the optimal scheduling of maintenance and, ultimately, plant uptime is maximized. Currently, most maintenance processes tend to be either reactive, or part of scheduled, or preventive maintenance. Such maintenance is being increasingly reported as a poor practice for two reasons: first, the component does not necessarily require maintenance, thus the maintenance cost is wasted, and secondly, failure catalysts are introduced into properly working components, which is worse. This paper first summarizes the technical aspects of CM including state estimation and state monitoring. The mathematical background of CM is mature enough even for commercial use in the nuclear industry. Considering the current computational capabilities of CM, its application is not limited by technical difficulties, but by a lack of desire on the part of industry to implement it. For practical applications in the nuclear industry, it may be more important to clarify and quantify the negative impact of unexpected outcomes or failures in CM than it is to investigate its advantages. In other words, while issues regarding accuracy have been targeted to date, the concerns regarding robustness should now be concentrated on. Standardizing the anticipated failures and the possibly harsh operating conditions, and then evaluating the impact of the proposed CM under those conditions may be necessary. In order to make the CM techniques practical for the nuclear industry in the future, it is recommended that a prototype CM system be applied to a secondary system in which most of the components are non-safety grade. Recently, many activities to enhance the safety and efficiency of the secondary system have been encouraged. With the application of CM to nuclear power plants, it is expected to increase profit while addressing safety and economic issues.

Structural health monitoring using piezoceramic transducers as strain gauges and acoustic emission sensors simultaneously

  • Huo, Linsheng;Li, Xu;Chen, Dongdong;Li, Hongnan
    • Computers and Concrete
    • /
    • 제20권5호
    • /
    • pp.595-603
    • /
    • 2017
  • Piezoceramic transducers have been widely used in the health monitoring of civil structures. However, in most cases, they are used as sensors either to measure strain or receive stress waves. This paper proposes a method of using piezoelectric transducers as strain gauges and acoustic emission (AE) sensors simultaneously. The signals received by piezoceramic transducers are decomposed into different frequency components for various analysis purposes. The low-frequency signals are used to measure strain, whereas the high-frequency signals are used as acoustic emission signal associated with local damage. The b-value theory is used to process the AE signal in piezoceramic transducers. The proposed method was applied in the bending failure experiments of two reinforced concrete beams to verify its feasibility. The results showed that the extracted low-frequency signals from the piezoceramic transducers had good agreement with that from the strain gauge, and the processed high-frequency signal from piezoceramic transducers as AE could indicate the local damage to concrete. The experimental results verified the feasibly of structural health monitoring using piezoceramic transducers as strain gauges and AE sensors simultaneously, which can advance their application in civil engineering.

홈의 형상에 따른 센서 감지거리 변화를 이용한 공구상태 모니터링에 관한 연구 (A Investigation into Tool State Monitoring by Sensing Changes according to Groove)

  • 손길호;김미루;이승준;정재호;류경희;이득우
    • 한국기계가공학회지
    • /
    • 제16권5호
    • /
    • pp.31-39
    • /
    • 2017
  • Research in the machine tool industry has focused on ICT-based smart machines rather than hardware technologies related to machine tools. Real-time tool-status monitoring is representative of this type of technology and has become important for measuring sensors during cutting processes. In this paper, we studied several research areas and used a round bar to conduct fundamental research into the axial displacement of the main spindle of a tool when it was subjected to a machining load. We were able to use the gap sensor to detect the axial displacement indirectly by using grooves with various shapes on the round bar and sensing the gaps between the grooves. We then determined the optimal groove shape for monitoring the tool state.

자기 동적 신경망을 이용한 RCP 감시 시스템의 경보진단 (Alarm Diagnosis of RCP Monitoring System using Self Dynamic Neural Networks)

  • 유동완;김동훈;성승환;구인수;박성욱;서보혁
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제49권9호
    • /
    • pp.512-519
    • /
    • 2000
  • A Neural networks has been used for a expert system and fault diagnosis system. It is possible to nonlinear function mapping and parallel processing. Therefore It has been developing for a Diagnosis system of nuclear plower plant. In general Neural Networks is a static mapping but Dynamic Neural Network(DNN) is dynamic mapping.쪼두 a fault occur in system a state of system is changed with transient state. Because of a previous state signal is considered as a information DNN is better suited for diagnosis systems than static neural network. But a DNN has many weights so a real time implementation of diagnosis system is in need of a rapid network architecture. This paper presents a algorithm for RCP monitoring Alarm diagnosis system using Self Dynamic Neural Network(SDNN). SDNN has considerably fewer weights than a general DNN. Since there is no interlink among the hidden layer. The effectiveness of Alarm diagnosis system using the proposed algorithm is demonstrated by applying to RCP monitoring in Nuclear power plant.

  • PDF

반도체 장비상태 모니터링을 위한 SCADA 시스템 구현 (SCADA System for Semiconductor Equipment Condition Monitoring)

  • 이윤지;윤학재;박효은;홍상진
    • 반도체디스플레이기술학회지
    • /
    • 제18권4호
    • /
    • pp.92-95
    • /
    • 2019
  • Automation control and the data for control of industrial equipment for the diagnosis and prediction is a key to success in the 4th industrial revolution. It increases process efficiency and productivity through data collection, realtime monitoring, and the data analysis. However, university and research environment are still suffering from logging the data in manual way, and we occasionally loss the equipment data logging due to the lack of automatic data logging system. State variable presents the current condition of the equipment operation which is closely related to process result, and it is valuable to monitor and analyze the data for the equipment health monitoring. In this paper, we demonstrate the collection of equipment state variable data via programmable logic controller (PLC) and the visualization of the collected data over the Web access supervisory control and data acquisition (SCADA). Test vehicle for the implementation of the suggested SCADA system is a relay switched physical vapor deposition system in the university environment.