• Title/Summary/Keyword: spatial problem

Search Result 1,471, Processing Time 0.026 seconds

A Study on the Fault Analysis for a Micro Smart Grid Simulator Design Using MEMS' Miniaturization Technology (MEMS의 소형화 기술을 이용한 마이크로 스마트 그리드 시뮬레이터 설계를 위한 고장해석법에 대한 연구)

  • Ko, Yun-Seok;Oh, Se-Pil;Kim, Hyo-Seong;Kim, In-Soo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.12 no.2
    • /
    • pp.315-324
    • /
    • 2017
  • The smart grid with distributed power supply introduces a number of problems including not only the problems of the existing power grid but also the problem of protection co-operation due to new electric phenomenon because it has a mixed operation structure combining the existing radial operation structure and the new loop operation structure. The EMTP based power system analysis method has flexibility and convenience from the view of system configuration but it requires another experimental verification because of uncertainty of design and analysis results. On the other hand, the real demonstration system has difficulties in observing accurate fault on large scale system due to considerable economical and spatial construction cost, system configuration constraint, and it is difficult to demonstrate the distributed, autonomous and adaptive control strategy of smart grid. In this paper, a basic theory for a micro smart grid simulator design using MEMS(Micro Electro-Mechanical Systems) miniaturization technology is studied which can safely and freely experiment and observe electrical phenomena, and distribution, autonomous adaptive control strategy for disturbances on 22.9kV smart grid under minimum economic and spatial cost.

Simplified Analytical Model for Flexural Response of Fiber Reinforced Plastic Decks (FRP 바닥판의 휨 해석모델 개발)

  • Kim, Young-Bin;Lee, Jae-Hong
    • Journal of Korean Association for Spatial Structures
    • /
    • v.5 no.3 s.17
    • /
    • pp.65-74
    • /
    • 2005
  • An analytical model was developed to investigate the flexural behavior of a pultruded fiber-reinforced plastic deck of rectangular unit module. The model is based on first-order shea. deformable plate theory (FSDT), and capable of predicting deflection of the deck of arbitrary laminate stacking sequences. To formulate tile problem, two-dimensional plate finite element method is employed. Numerical results are obtained for FRP decks under uniformly-distributed loading, addressing the effects of fiber angle and span-to-height ratio. It is found that the present analytical model is accurate and efficient for solving flexural behavior of FRP decks. Also, as the height of FRP deck plate is higher, the necessity of higher order Shear deformable plate theory(HSDT) is announced, not the FSDT in the plate analysis theory.

  • PDF

Microvibration Control of High Technology Facilities Subjected to Train-induced Excitation using Smart Base Isolation (열차진동하중을 받는 첨단시설물의 스마트 면진시스템을 이용한 미진동제어)

  • Kim, Hyun-Su;Kang, Joo-Won;Kim, Young-Sik
    • Journal of Korean Association for Spatial Structures
    • /
    • v.12 no.2
    • /
    • pp.99-108
    • /
    • 2012
  • Microvibration problem of high-technology facilities, such as semi-conductor plants and TFT-LCD plants, has been considered as important factors that affects the performance of products and thus it is regarded as important in facilities with high precision equipments. In this paper, various base isolation control systems are used to investigate their microvibration control performance. To this end, train-induced ground acceleration is used for time history analysis and three-story example building structure is employed. Microvibration control performance of passive and smart base isolation systems have been investigated in this study. Based on numerical simulation results, it has been verified that smart base isolation system can control microvibration of a high-technology facility subjected to train-induced excitation.

Vibration Control Performance Evaluation of Hybrid Mid-Story Isolation System for a Tall Building (하이브리드 중간층 지진격리시스템의 고층 건물 진동 제어 성능 평가)

  • Kim, Hyun-Su;Kang, Joo-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.18 no.3
    • /
    • pp.37-44
    • /
    • 2018
  • A base isolation system is widely used to reduce seismic responses of low-rise buildings. This system cannot be effectively applied to high-rise buildings because the initial stiffness of the high-rise building with the base isolation system maintains almost the same as the building without the base isolation system to set the yield shear force of the base isolation system larger than the design wind load. To solve this problem, the mid-story isolation system was proposed and applied to many buildings. The mid-story isolation system has two major objectives; first to reduce peak story drift and second to reduce peak drift of the isolation story. Usually, these two objectives are in conflict. In this study, a hybrid mid-story isolation system for a tall building is proposed. A MR (magnetorheological) damper was used to develop the hybrid mid-story isolation system. An existing building with mid-story isolation system, that is "Shiodome Sumitomo Building" a high rise building having a large atrium in the lower levels, was used for control performance evaluation of the hybrid mid-story isolation system. Fuzzy logic controller and genetic algorithm were used to develop the control algorithm for the hybrid mid-story isolation system. It can be seen from analytical results that the hybrid mid-story isolation system can provide better control performance than the ordinary mid-story isolation system and the design process developed in this study is useful for preliminary design of the hybrid mid-story isolation system for a tall building.

The Improvement Method of Position Accuracy of Digital-Map in Small Area (소규모 지역에서 수치지도의 위치정확도 향상 방안에 관한 연구)

  • 이근상;장영률
    • Spatial Information Research
    • /
    • v.9 no.2
    • /
    • pp.263-275
    • /
    • 2001
  • With increasing of utilization of 1/1,000 Digital-Map being constructed with NGIS project, it is entering upon the stage that problem as the inspection of position accuracy of Digital-Map before its use. This paper evaluated position accuracy of Digital-Map being based on the construction of college facility management system into small area and presented modification/renovation of Digital-Map on area being occurred position error. With a view to evaluation of position error to building using RTK survey, position error was shown more than 0.5mm that is prescribed in survey-law. In order to acquire good position accuracy, first we carried out Static survey to college and selected control point. And, we evaluated coordinate value to important building from control point and compared these results with RTK survey results. Second, we carried out Affine transform based on the control point of building being surveyed with RTK, transformed pre-constructed Digital-Map and compared these results with RTK Survey results. We analyzed first and second method and presented improvement method of position accuracy of Digital-Map suited on small area.

  • PDF

A Study on the Improvement of Management for Survey Control Points in Seoul City (서울시 측량 기준점 관리 개선방안에 관한 연구)

  • Lee, Woo Sik;Lee, Eun Young
    • Spatial Information Research
    • /
    • v.20 no.5
    • /
    • pp.111-118
    • /
    • 2012
  • Survey control points managed by national and local governments are associated with civilian's property and they are very important national facilities. Despite the importance of surveying results, Database and mark of survey control points, there are many problems noticed of the management aspects such as manpower, systems, and related law. Currently, each local government has built and operated Geographic Information System(GIS) independently by National Geographic Information Systems(NGIS) results. but it is still difficult to have the integration, linking and utilizing. Therefore, In this study proposed the functional improvement of GIS based control points integrated system for providing information and management and the establishment of first-payment system due to the moving of control points. Through this studies will be able to solve the problem of recovery charges according to unknown contractor and establish the basis of manager and user-centric one-stop integration system.

Vibrations of Complete Paraboloidal Shells with Variable Thickness form a Three-Dimensional Theory

  • Chang, Kyong-Ho;Shim, Hyun-Ju;Kang, Jae-Hoon
    • Journal of Korean Association for Spatial Structures
    • /
    • v.4 no.4 s.14
    • /
    • pp.113-128
    • /
    • 2004
  • A three-dimensional (3-D) method of analysis is presented for determining the free vibration frequencies and mode shapes of solid paraboloidal and complete (that is, without a top opening) paraboloidal shells of revolution with variable wall thickness. Unlike conventional shell theories, which are mathematically two-dimensional (2-D), the present method is based upon the 3-D dynamic equations of elasticity. The ends of the shell may be free or may be subjected to any degree of constraint. Displacement components $u_r,\;u_{\theta},\;and\;u_z$ in the radial, circumferential, and axial directions, respectively, are taken to be sinusoidal in time, periodic in ${\theta}$, and algebraic polynomials in the r and z directions. Potential (strain) and kinetic energies of the paraboloidal shells of revolution are formulated, and the Ritz method is used to solve the eigenvalue problem, thus yielding upper bound values of the frequencies by minimizing the frequencies. As the degree of the polynomials is increased, frequencies converge to the exact values. Convergence to four digit exactitude is demonstrated for the first five frequencies of the complete, shallow and deep paraboloidal shells of revolution with variable thickness. Numerical results are presented for a variety of paraboloidal shells having uniform or variable thickness, and being either shallow or deep. Frequencies for five solid paraboloids of different depth are also given. Comparisons are made between the frequencies from the present 3-D Ritz method and a 2-D thin shell theory.

  • PDF

An Experimental Study on the Flexural Behavior of Pre-loaded RC Beams Strengthened with CFRP-Rod (선하중(先荷重)을 받은 RC보의 CFRP-Rod 휨보강 효과에 대한 실험적 연구)

  • Ye, Sang-Min;Chun, Woo-Chul;Kang, Joo-Won;Park, Sung-Moo
    • Journal of Korean Association for Spatial Structures
    • /
    • v.7 no.1 s.23
    • /
    • pp.79-85
    • /
    • 2007
  • Steel plate bonding method with epoxy is common applied to repair and strengthen RC structures, but Steel is apt to corrode quickly, hard to manufacture and heavy. To overcome these defects, it is carried out research on strengthening RC structures with FRP(Fibre Reinforced Polyrner/Plastic) FRP is generally used in the shape of Plate or Sheet, but it has weak point such as premature failure, difficult work. To cope with these problem, NSMR(Near Surface Mounted Reinforcement) which uses CFRP in the shape of Rod is proposed and carried out active research on strengthening effect of variables such as quantity, anchorage length and space of CFRP-Rod. Strengthening with CFRP-Rod is carried out under loading to some degree in fact, and so the amount of pre-loading is selected as variable in this research. The amount of pre-loading is chosen in proportion to nominal strength of non-strengthened specimen with CFRP-Rod.

  • PDF

An Analysis on the Spatial Characteristics of Residential and Nursing Units of Large Skilled Nursing Facilities for the Elderly in City Areas (도시지역 대규모 노인전문요양시설 거주 및 간호단위의 공간구성 특성 분석)

  • Lee, Min-Ah
    • Korean Institute of Interior Design Journal
    • /
    • v.16 no.4
    • /
    • pp.54-61
    • /
    • 2007
  • The purpose of this study was to investigate the spatial characteristics of residential and nursing units in large skilled nursing facilities for the elderly that were located in city areas, and to discuss the way for efficient unit care. For collecting the data, the researcher visited 6 facilities to make explorations and to interview the staff concerned. Most of the research facilities had systematic residential units that each unit basically had elderly private rooms and the spaces for small group. The number of elderly residents per unit was appropriate for the limit which was suggested by Kwon(2002), but the sizes of small group spaces were smaller than the standard limit($1.62m^{2}$ per resident). The nursing units were made up of nursing station, 2-4 residential units, spaces for large group of residents, hair dressing, nurse, living assistants, bathing, storage and etc. Some of them had problem in efficiency of space use because they did not have distinct usage. In conclusion, this study suggests that each floor has one nursing unit including 40 residents maximum and each nursing unit consists of 2-3 residential units that have 20 residents maximum per unit. In each residential unit, the furniture and spaces for efficient unit-care should be arranged, such as TV, dining table, kitchenette, bathroom, and rooms for living assistants. The hall type is better for the small group so that it has a transitional characteristic leading to the public spaces. The large group space needs to have clear usage such as conducting program differentiated from small group, and various furniture such as sofa, TV, table, and etc which encourage the elderly voluntary use.

Content-based Image Retrieval using Variable Region Color (가변 영역 색상을 이용한 내용기반 영상검색)

  • Kim Dong-Woo;Song Young-Jun;Kwon Dong-Jin;Ahn Jae-Hyeong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.6 no.5
    • /
    • pp.367-372
    • /
    • 2005
  • In this paper, we proposed a method of content-based image retrieval using variable region. Content-based image retrieval uses color histogram for the most part. But the existing color histogram methods have a disadvantage that it reduces accuracy because of quantization error and absence of spatial information. In order to overcome this, we convert color information to HSV space, quantize hue factor being pure color information, and calculate histogram of the factor. On the other hand, to solve the problem of the absence of spatial information, we select object region in consideration of color feature and region correlation. It maintains the size of region in the selected object region. But non-object region is integrated in one region. After of selection variable region, we retrieve using color feature. As the result of experimentation, the proposed method improves 10$\%$ in average of precision.

  • PDF