• 제목/요약/키워드: spacers

검색결과 254건 처리시간 0.022초

Monitoring and control of wind-induced vibrations of hanger ropes of a suspension bridge

  • Hua, Xu G.;Chen, Zheng Q.;Lei, Xu;Wen, Qin;Niu, Hua W.
    • Smart Structures and Systems
    • /
    • 제23권6호
    • /
    • pp.683-693
    • /
    • 2019
  • In August 2012, during the passage of the typhoon Haikui (1211), large amplitude vibrations were observed on long hangers of the Xihoumen suspension Bridge, which destroyed a few viscoelastic dampers originally installed to connect a pair of hanger ropes transversely. The purpose of this study is to identify the cause of vibration and to develop countermeasures against vibration. Field measurements have been conducted in order to correlate the wind and vibration characteristics of hangers. Furthermore, a replica aeroelastic model of prototype hangers consisting of four parallel ropes was used to study the aeroelastic behavior of hanger ropes and to examine the effect of the rigid spacers on vibration mitigation. It is shown that the downstream hanger rope experiences the most violent elliptical vibration for certain wind direction, and the vibration is mainly attributed to wake interference of parallel hanger ropes. Based on wind tunnel tests and field validation, it is confirmed that four rigid spacers placed vertically at equal intervals are sufficient to suppress the wake-induced vibrations. Since the deployment of spacers on hangers, server hanger vibrations and clash of hanger ropes are never observed.

시공균열저항성을 갖는 본타입 콘크리트 스페이서 개발 (Development of the Bone Type Concrete Spacer with Crack Resistance for Construction)

  • 이민재;김지호;성종현;최덕진;김진만
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 추계 학술논문 발표대회
    • /
    • pp.35-38
    • /
    • 2012
  • Spacers which we have studied is the secondary product of the concrete to apply on concrete structure. It is needed to secure equal or greater performance than structural concrete that it is applied. There is a tendency that concrete structures are strengthened more and more. Therefore, designed set up position of reinforcement is used more and more, so it is needed increasingly high strength spacer. We have been doing a series of research to develop the different typed high strength spacer having crack resistance during constructing. The bearing load of different type spacer shows approximately 35% lower load than those in the general spacers.

  • PDF

정전접합을 이용한 고종횡비의 FED용 스페이서 공정 개발 (Development of High Aspect Ratio Spacer Process using Anodic Bonding for FED)

  • 김민수;김관수;문권진;우광제;이남양;박세광
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제49권1호
    • /
    • pp.70-72
    • /
    • 2000
  • In this paper, a spacer process for FED(Field Emission Display) was developed with the glass to glass anodic bonding technology using Al film as an interlayer and a 3.5 inch monochromatic type FED was fabricated. Holder to dislocate spacers vertically was designed with (110) Si wafer by bulk etching. Spacers, $100\mum\; width\; and\; 1000\mum$ height, were formed on anode panel by spacer to glass anodic bonding and the fabricated FED was operated for emission at 1㎸ anode voltage.

  • PDF

The Investigation of flexible flat display in improving flexibility

  • Huang, Chi-Yuan;Tsao, Keng-Yu;Chou, Ruei-Shu;Chiang, Wen-Yen;Mo, Chi-Neng;Lyu, Robert
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2008년도 International Meeting on Information Display
    • /
    • pp.660-663
    • /
    • 2008
  • In this study, it was mainly focused on the mechanism and reliability performances of PI/PET composites after many times of curving. We developed a new process of spacer for flexible display to improve the maintenance of cell gap. This new process used the laser carving technology, which is widely applied on printing press, to produce the pattern of spacers and shaped both of the alignment film and spacers simultaneously by press of pattern. Assembling the spacer-shaped film and plastic substrates together well and it shows an excellent performance on the maintenance of cell gap and reliability of curving.

  • PDF

1, 15-Bis(2-Hydroxybenzyl)-2, 6, 10, 14-Tetraazapentadecane 리간드합성, 양성자 해리상수 및 전이금속에 대한 안정도 상수결정 (Synthesis, Protonation Constants and Stability Constants for Transition Metal ions(II) of 1, 15-Bis(2-Hydroxybenzyl)-2, 6, 10, 14-Tetraazapentadecane)

  • 김선덕;김준광;이우식
    • 분석과학
    • /
    • 제13권6호
    • /
    • pp.810-814
    • /
    • 2000
  • The open-chain hexadentate $N_4$, $O_2$ ligands 1, 15-bis(2-hydroxybenzyl)-2, 6, 10, 14-tetraazapentadecane (BSATPD. 4HCl) has been synthesized as its tetrahydro-chloride salt and characterized by EA, IR, NMR, and Mass spectrum. Its protonation constants ($logK_n{^H}$) and stability constants ($logK_{ML}$) for $Cu^{2+}$, $Ni^{2+}$, $Co^{2+}$ and $Zn^{2+}$ ions were determined in aqueous solution by potentiometry and compared with those of analogous $N_4$, $O_2$ ligands contain ethtylenic spacers or propylenic spacers, which make six-membered chelate rings between the aliphatic nitrogen atoms.

  • PDF

The development of high brightness IPS mode for LCD Monitors

  • Kang, In-Byeong;Youn, Won-Gyun;Cho, So-Haeng;Song, In-Duk;Ahn, In-Ho;Chung, In-Jae
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2000년도 제1회 학술대회 논문집
    • /
    • pp.11-12
    • /
    • 2000
  • An 18.1" Thin Film Transistor Liquid Crystal Display (TFT LCD) monitor adopting high brightness In Plane Switching (IPS) technology was realized. While conventional IPS structure used a Chromium (Cr) and Molybdenum (Mo) for a drain electrode, Indium Tin Oxide (ITO) was proposed and verified in this paper. Black sticky micropeal spacers were introduced for the reduction of light scattering phenomena, which was observed at dark room with the conventional micropeal spacers. With the proposed method, more than 10 % aperture ratio was increased and the excellent image quality was obtained.

  • PDF

Flexible LCDs with Columnar Spacers for Fast Response and Wideviewing

  • Kim, Dong-Woo;Lim, Yong-Woon;Na, Jun-Hee;Yu, Chang-Jae;Lee, Sin-Doo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2005년도 International Meeting on Information Displayvol.I
    • /
    • pp.407-410
    • /
    • 2005
  • We report on a high speed flexible display based on a deformed helix ferroelectric liquid crystal (DHFLC) in a vertically aligned configuration. The mechanical stability of the flexible DHFLC display was achieved using a periodic array of columnar spacers formed directly on the top sides of in-plane electrodes by the photolithography technique. Several unique features of display performances such as flexibility, uniform alignment, fast response, and gray scale capability were obtained.

  • PDF

개선된 GIS 스페이서의 전계해석 및 파괴전압특성 (Electric Field Analyses and Breakdown Voltage Characteristics on the Improved Spacers for GIS)

  • 류성식;신동석;곽희로;김경화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1921-1923
    • /
    • 2000
  • This paper describes the particle-initiated breakdown characteristics of various spacers, which have a ribbed surface, in the presence of a metallic particle. The particles was attached on the surface of each spacer. The breakdown voltages were measured by changing the particle position on the spacer, the length and thickness of the rib. Also the electrical field analyses were performed. As a result, the breakdown voltage of the spacer with two ribs was highest, and it was varied by the length and the thickness of the rib. Especially, in case of the rib with round edge the breakdown voltage was higher than that with rectangular edge, which complied with the result through the field analysis.

  • PDF

GIS용 절연스페이서 신뢰성령가기반 구축 (Construction of Reliability Assessment Infrastructure for Spacers in GIS)

  • 이정기;김민규;김익수;정주영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.180-181
    • /
    • 2006
  • In this paper, there have been brief review about the important consideration in laboratory planning and construction of the reliability assessment infrastructure including 400 kV, 120 kVA AC test system, which enable to evaluate the HV long-term overcharged withstand performance for spacers using in Gas Insulated Switchgears up to transmission class, Also it is described simply about its trial running of the whole test system and its assessment example. To inform the founded national code, RS C 0084, and the procedure for getting a reliability assessment certificate issued by the government, brief description of the code and summation of test results have been conducted.

  • PDF