• 제목/요약/키워드: sound vibration

검색결과 2,255건 처리시간 0.026초

방음벽 안전을 위한 기준 조사 및 분석 (Investigation and Analysis of Regulations for the Safety of the Noise Barrier)

  • 허영;김흥식
    • 한국소음진동공학회논문집
    • /
    • 제13권9호
    • /
    • pp.730-734
    • /
    • 2003
  • For the noise reduction measures in a construction field or near the traffic line receiver is often the most economic measure in order to exclude the propagated sound. The dimension of the barrier is decided by the noise and construction design, and the constructive quality of a soundproof panel shall be secured in accordance with KS F4770 to guarantee the safety of sound barriers. In this paper the problems included in the KS F4770-1 that is the regulation for the metallic sound barrier of the absorption type are identified and it is suggested what to be corrected or improved. Through a series of the analyses, conclusions were reached that it is required to improve test methods in KS F4770-1 as well as to break down test loads for building more cost-effective sound barrier.

점가진력에 의해 방사된 읍압을 이용한 다중 적층 흡차음 시스템의 차음 성능 예측 (Prediction of Isolation Performance of Multi-Layered Sound Barrier System Using the Sound Pressure Radiated by Point Impact)

  • 김정수;신재성;강연준
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.1081-1085
    • /
    • 2002
  • A modeling is developed to predict the isolation performance of sound barrier systems under the sound pressure radiated from excited by point impact. The predicted results are compared with the measured results obtained by using APAMAT II. This instrument provides a combination of structure-borne noise and air-borne noise, which corresponds to rolling noise, by applying the excitation system projected steel balls against the steel sheet.

  • PDF

관 내 세정을 위한 초음파 음장 연구 (A Study on Ultrasonic Sould-fields for Cleaning in a Pipe)

  • 이정구;김진오
    • 한국소음진동공학회논문집
    • /
    • 제15권5호
    • /
    • pp.564-570
    • /
    • 2005
  • This paper presents some results of research for applying ultrasonic cleaning to an interior wall of cylindrical pipe. As the cleaning is achieved better for higher sound pressure, ultrasonic sound field in a cylindrical container is considered. The paper identifies nonuniform sound field established by the radiation of a cylindrical transducer driven at resonant frequency, Numerical analysis predicts the sound pressure distribution, and experiment verifies the trend of analysis results. Experiment observes the cleaning effect, and this paper suggests the possibility of using a cylindrical ultrasonic cleaning device.

병렬 다공판 시스템의 흡음특성과 성능에 관한 연구 (A Study on the Sound Absorptive Characteristics and Performance of Parallel Perforated Plate Systems)

  • 홍병국;송화영;서성원;이동훈
    • 한국소음진동공학회논문집
    • /
    • 제15권9호
    • /
    • pp.1003-1008
    • /
    • 2005
  • The acoustic absorption of a multiple layer perforated plate system is very good near the resonance frequency region, while it has been regarded as a demerit that its frequency bandwidth is considerably narrow. In order to overcome such a demerit, the parallel perforated plates with different porosities are proposed. The sound absorption of such system composed of a parallel perforated plate is calculated by an equivalent electroatoustic circuit approach and validated by comparing the calculated absorption coefficients with those measured by the two-microphone impedance tube method. The sound absorptive characteristics and performance of parallel perforated plate systems are discussed from a standpoint of frequency bandwidth related with sound absorption.

축소잔향실의 저주파수 차음성능평가에 관한 고찰 (Study on evaluation of sound insulation performance of low frequency in a scaled reverberation chamber)

  • 강현주;김봉기;오영근
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.1376-1378
    • /
    • 2006
  • Numerical and experimental study were carried out to characterize sound fields of low frequency in a scaled reverberation chamber for measurement of sound insulation of panels. By using BEM, lower modes of the chamber are identified and then predicted the effect of diffusers in order to destruct lower modes. Compared results with measurements show reasonable agreements, especially at the first end second modes. Based on numerical prediction, the diffuser are installed in order to improve sound fields to be more diffuse than ever. It is found that the diffuser put in nodal line of the chamber destruct evidently the first mode. Consequently, the measuring error at the low frequency can be relatively reduced compare to the case of without diffuser.

  • PDF

TDOA 기법을 이용한 소음원 위치파악에 관한 인구 (Experimental Studies for Noise Source Positioning Using TDOA Algorithm)

  • 이욱;최종수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.138-142
    • /
    • 2006
  • Time Difference of Arrival (TDOA) algorithm was applied to sound source positioning. Using measured microphones signal, difference of distance from source to sensors were estimated by TDOA and speed of sound, and taken by navigational measurements. And iteration procedures were induced to find the actual source location. For the case of stationary and moving sound source, validation test were performed in the anechoic room. In the stationary case, the error of positioning is less then 1.3% in length scale, and it could be seen proper filtering processes were required in the application of moving sound source.

  • PDF

교통소음의 음질 특성에 따른 불쾌도 감성변화에 대한 연구 (A Study on Changes of the Annoyance Perception for Sound Quality Characteristics of the Traffic Noise)

  • 송치문;허덕재;조경숙;황대선;조연
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.1272-1275
    • /
    • 2006
  • The A-weighting curve, very well explain the human perception for various frequency, is used to assess the traffic noise as well as the environmental noise. However, it does not reflect the annoyance perception appropriately because it assesses the noise at an A-weighted equivalent noise level of 1 kHz. In this study, we acquired the sound quality of traffic noise included various frequency and studied the human perception caused by change of frequency range.

  • PDF

사운드스케이프 적용을 위한 옥외 P.A. 시스템 적정 인지레벨에 관한 실험적 연구 (An Experimental Study on the Optimistic Recognition Level of Public Address System as a Soundscape Application Facility)

  • 송민정;장길수;신훈;신용규;이태강
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.726-729
    • /
    • 2006
  • As a active soundscape facility, P.A. system is a useful instrument to give place identity and vitality by letting out music, environmental music, bird singing sound etc. In this study, to know the optimistic distance and sound level range of introducing sound, sound levels due to distance were measured and subject responses were checked by questionnaire. Levels from 64dB to 71dB are recommended by subjects. And the optimistic level of introducing level is related with level variance of sound source. The results of this study could used for street furniture location design and P.A. system output level.

  • PDF

공기조화 취출구 소음 평가를 위한 물리지수 분석 (Analysis of Physical Parameters for the Evaluation of HVAC Diffuser Noise)

  • 박현구;김항;고성석;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.402-405
    • /
    • 2006
  • The diffuser noise of HVAC(heating ventilating and air-conditioning) uses dB(A) or NC as a indoor noise criteria that ASHRAE represents, and there is no specific guide line for application. According to the previous study, there are some problems like that even though the sound level of sound source is same, the NC shows different values, which makes the noise rating confused. This problem is caused by the frequency characteristics of sound source and its sound level. Therefore, appropriate evaluation method should be considered based on the subjective responses. This study aims to analyze the physical parameters appropriate for the evaluation of HVAC diffuser noise. To achieve this, recording of sound sources, calculation of physical parameters and psycho-acoustic experiment were carried out and the results were derived from the correlation analysis between physical parameters and subjective evaluatio

  • PDF

바닥충격음 저감방안에 따른 성능평가 (Evaluation of Floor Impact Sound Performance according to the Reduction Methods)

  • 최경석;최현중;양관섭;김경우
    • 한국소음진동공학회논문집
    • /
    • 제14권9호
    • /
    • pp.811-818
    • /
    • 2004
  • Impact sounds, such as those created by footsteps, the dropping of an object or the moving of furniture, can be a source of great annoyance in residential buildings. The character and level of impact noise generated depends on the object striking the floor, on the basic structure of the floor, and on the floor covering. This study base on the evaluate of isolation performance of impact sound according to the impact noise reduction methods. Reduction methods consist of four ways. First way is increase thickness of bare floor and other ways are using the soft coverings on the floor and ceiling assembles. Last way is make floating floor with shock absorbing materials.