• Title/Summary/Keyword: sound speed image

Search Result 28, Processing Time 0.026 seconds

Measurement of the Average Speed of Ultrasound and Implementation of Its Imaging Using Compounding Technique in Medical Ultrasound Imaging (초음파 의료영상에서 컴파운딩 기법을 이용한 초음파의 평균 음속도의 측정과 음속도 영상의 구현)

  • Jeong, Mok-Kun;Kwon, Sung-Jae;Choi, Min-Joo
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.3
    • /
    • pp.233-240
    • /
    • 2009
  • Using a spatial compound imaging technique in a medical ultrasound imaging system, the average speed of sound in a medium of interest is measured, and imaging of its distribution is implemented. When the brightness reaches the highest level in an ultrasonic image obtained as the speed of sound used in focusing is varied, it turns out that the focusing has been accomplished satisfactorily and that the speed of sound which has been adopted becomes the sought-after average speed of sound. Because spatial compound imaging provides many different views of the same object, the adverse effect of erroneous speed-of-sound estimation tends to be more severe in compound imaging than in plain B-mode imaging. Thus, in compound imaging, the average speed of sound even in the case of speckled images can be accurately estimated by observing the brightness change due to different speeds of sound employed. Using this new method that offers spatial diversity, we can construct an image of the speed of sound distribution in a phantom embedded with a 10-mm diameter plastic cylinder whose speed of sound is different from that of the background. The speed of sound in the cylinder is found to be different from that of the surrounding medium.

Transducer Combination for High-Quality Ultrasound Tomography Based on Speed of Sound Imaging (속도 분포 기반 단층촬영을 위한 최적의 트랜스듀서의 조합)

  • Kim, Young Hun;Park, Kwan Kyu
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.1
    • /
    • pp.27-34
    • /
    • 2016
  • The type of ultrasound transducer used influences the quality of a reconstructed ultrasound image. This study analyzed the effect of transducer type on ultrasound computed tomography (UCT) image quality. The UCT was modeled in an ultrasound simulator by using a 5 cm anatomy model and a ring-shape 5 MHz 128 transducer array, which considered attenuation, refraction, and reflection. Speed-of-sound images were reconstructed by the Radon transform as the UCT image modality. Acoustic impedance images were also reconstructed by the delay-and-sum (DAS) method, which considered the speed of sound information. To determine the optimal combination of transducers in observation, point-source, flat, and focused transducers were tested in combination as trasmitters and receivers; UCT images were constructed from each combination. The combination of point-source/flat transducer as transmitting and receiving devices presented the best reconstructed image quality. In UCT implementation, the combination of a flat transducer for transmitting and a point transducer for receiving permitted acceptable image quality.

Improving Wind Speed Forecasts Using Deep Neural Network

  • Hong, Seokmin;Ku, SungKwan
    • International Journal of Advanced Culture Technology
    • /
    • v.7 no.4
    • /
    • pp.327-333
    • /
    • 2019
  • Wind speed data constitute important weather information for aircrafts flying at low altitudes, such as drones. Currently, the accuracy of low altitude wind predictions is much lower than that of high-altitude wind predictions. Deep neural networks are proposed in this study as a method to improve wind speed forecast information. Deep neural networks mimic the learning process of the interactions among neurons in the brain, and it is used in various fields, such as recognition of image, sound, and texts, image and natural language processing, and pattern recognition in time-series. In this study, the deep neural network model is constructed using the wind prediction values generated by the numerical model as an input to improve the wind speed forecasts. Using the ground wind speed forecast data collected at the Boseong Meteorological Observation Tower, wind speed forecast values obtained by the numerical model are compared with those obtained by the model proposed in this study for the verification of the validity and compatibility of the proposed model.

Identification of frequency determining sound generating organ of cicadas with the Helmholtz resonator structure (헬름홀쯔 공명기 구조 매미 소리의 주파수 결정 발음기관 규명)

  • Yoon, Ki-sang;Cho, Se-hyun;Jung, Yoon-sang;Lee, Dong-hyun
    • The Journal of the Acoustical Society of Korea
    • /
    • v.37 no.5
    • /
    • pp.276-283
    • /
    • 2018
  • The purpose of the study is to identify a sound generating organ that has a major influence on the central frequency of the cicadas with the Helmholtz resonator structure for the first time. The sound of cicadas Cryptotympana atrata and Hyalessa fuscata were recorded and analyzed, then the motion of the tymbals was analyzed with a high-speed camera to compare the relationship between the frequency of sound and the motion of the tymbals. As a result, there was little difference in the frequency distribution of calling song and scream for two species. The tymbals of C. atrata oscillated in three vibration modes, while those of H. fuscata oscillated in one mode. There was no difference in the frequency of both tymbals of both cicadas, and three vibration modes of C. atrata generated sound with different frequency bands. The frequency band of tymbals and the central frequency band of calling song were very similar. In conclusion, it is presumed that the frequency of the cicadas with the Helmholtz resonator structure was determined by mode frequency of the tymbals than resonance condition of the abdomen.

Design and Implementation of Multimedia Learning System based PDA (PDA기반 멀티미디어 학습시스템 설계 및 구현)

  • Lee, Sun-Ki;Kim, Chang-Soo;Shim, Kyu-Bark
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.16 no.2
    • /
    • pp.163-170
    • /
    • 2004
  • The rapid exchanges of mobile computing environment and development of wireless communication are providing many effects for learning activity of students. Recently, PDA system developers which are studying memory capacity, communication speed and size of screen support techniques to be capable of learning from students in the wireless or moving environment. In this viewpoints, this paper has a purpose to design multimedia learning system to be able to do with sound lecture contents. The implemented system largely consists of two parts which have the teacher module and students module. The one manages learning progress of students, class management, bulletin board and etc. The other is capable of using studying and bulletin functions. The main idea of this research is focus to upgrade the effect of learning without almost treating the existing studies, which can be listening sound lecture and also seeing text and image at the same time.

Optimum Image Compression Rate Maintaining Diagnostic Image Quality of Digital Intraoral Radiographs

  • Song Ju-Seop;Koh Kwang-Joon
    • Imaging Science in Dentistry
    • /
    • v.30 no.4
    • /
    • pp.265-274
    • /
    • 2000
  • Purpose: The aims of the present study are to determine the optimum compression rate in terms of file size reduction and diagnostic quality of the images after compression and evaluate the transmission speed of original or each compressed image. Materials and Methods: The material consisted of 24 extracted human premolars and molars. The occlusal surfaces and proximal surfaces of the teeth had a clinical disease spectrum that ranged from sound to varying degrees of fissure discoloration and cavitation. The images from Digora system were exported in TIFF and the images from conventional intraoral film were scanned and digitalized in TIFF by Nikon SF-200 scanner (Nikon, Japan). And six compression factors were chosen and applied on the basis of the results from a pilot study. The total number of images to be assessed were 336. Three radiologists assessed the occlusal and proximal surfaces of the teeth with 5-rank scale. Finally diagnosed as either sound or carious lesion by one expert oral pathologist. And sensitivity, specificity and k value for diagnostic agreement was calculated. Also the area (Az) values under the ROC curve were calculated and paired t-test and oneway ANOVA test was performed. Thereafter, transmission time of the image files of the each compression level was compared with that of the original image files. Results: No significant difference was found between original and the corresponding images up to 7% (1 : 14) compression ratio for both the occlusal and proximal caries (p<0.05). JPEG3 (1 : 14) image files are transmitted fast more than 10 times, maintained diagnostic information in image, compared with original image files. Conclusion: 1 : 14 compressed image file may be used instead of the original image and reduce storage needs and transmission time.

  • PDF

Tool Monitoring System using Vision System with Minimizing External Condition (환경영향을 최소화한 비전 시스템을 이용한 미세공구의 상태 감시 기술)

  • Kim, Sun-Ho;Baek, Woon-Bo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.5
    • /
    • pp.142-147
    • /
    • 2012
  • Machining tool conditions directly affect to quality of product and productivity of manufacturing. Many researches performed for tool condition monitoring in machining process to improve quality and productivity. Conventional methods use characteristics of signal for cutting force, motor current consumption, vibration of machine tools and machining sound. Recently, diameter of machining tool is become smaller for minimizing of mechanical parts. Tool condition monitoring using conventional methods are relatively difficult because micro machining using small diameter tool has low machining load and high cutting speed. These days, the direct monitoring for tool conditions using vision system is performed actively. But, vision system is affected by external conditions such as back ground of image and illumination. In this study, minimizing technology of external conditions using distribution analysis of image data are developed in micro machining using small diameter drill and tap. The image data is gathered from vision system. Several sets of experiment results are performed to verify the characteristics of the proposed machining technology.

A Study on Intelligent Railway Level Crossing System for Accident Prevention

  • Cho, Bong-Kwan;Jung, Jae-Il
    • International Journal of Railway
    • /
    • v.3 no.3
    • /
    • pp.106-112
    • /
    • 2010
  • Accidents at level crossing have large portion on train accidents, and causes economical loss by train delay and operational interruption. Various safety equipments are employed to reduce the accident at level crossing, but existing warning device, and crossing barrier are simple train-oriented protection equipments. In this paper, intelligent railway level crossing system is proposed to prevent and reduce accidents. For train driver's prompt action, image of level crossing and obstacle warning message are continuously provided to train driver through wireless communication in level crossing control zone. Obstacle warning messages, which are extracted by computer vision processing of captured image at level crossing, are recognized by train driver through message color, flickering and warning sound. It helps train driver to decide how to take an action. Meanwhile, for vehicle driver's attention, location and speed of approaching train are given to roadside equipments. We identified the effect of proposed system through test installation at Sea train and Airport level crossing of Yeong-dong line.

  • PDF

Proposal of a non-coherent Communication Protocol with Ultra Sonic which can Improve the Communication Speed (넌코히어런트 전송 방식에서 초음파를 이용한 디지털 통신속도 개선 프로토콜 제안)

  • Yoon, Byung-Woo
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.10 no.1
    • /
    • pp.1-6
    • /
    • 2009
  • Propagation of electromagnetic wave in the water or underground is very difficult because of the conductivity of the propagation materials. In this case, we usually use acoustic signal as ultrasonic but, it is not easy to transfer long distance with coherent method because of time varying multipath, doppler effect, and attenuations. So, we use noncoherent method as FSK to communicate between long distances. But, as the propagation speed of acoustic sound is very slow, the BW of the channel is narrow. It is very hard to guaranty the enough speed of communication like digital image data. In this paper, we proposed a new data communication protocol which can transmit multi-bit digital data with every single ping, and improve the data communication speed in the water.

  • PDF

Reflection - Transmission Type Inverse Scattering Ultrasonic Computed Tomography Using Cirucular Arc Linear Array Transducers (원호형 선배열 트랜스듀서를 이용한 빈사-투과형 역산란 초음파 토모그래피)

  • 김정순;하강열;산전황;김무준
    • The Journal of the Acoustical Society of Korea
    • /
    • v.23 no.4
    • /
    • pp.268-273
    • /
    • 2004
  • A method of reflection-transmission type ultrasonic inverse scattering image was presented using linearly arrayed transducers in inner surface of half-cylinder. In this method, to reduce the number of data, the mirror effect using a reflector behind object and pulse wave with finite frequency band, To verify the proposed method, a computer simulation was performed for organic phantom specimen, As the results. it was verified that the reconstructed image was satisfactory even when the limitation view angle was limited to around 30 deg.