참고문헌
- A. Goss, R. L. Johnston, and F. Dunn, "Comprehensive compilation of empirical ultrasonic properties of mammalian tissues," J. Acoust. Soc. Am, vol. 64, no. 2, pp. 423-457, Aug.1978 https://doi.org/10.1121/1.382016
- H. Hiroyuki, O. Shigeo, and T. Motonao, "Relationship between speed of sound in and density of normal and diseased rat livers," Jpn. J. Appl. Phys., vol. 33, no. 5B, pp. 3130-3133, 1994 https://doi.org/10.1143/JJAP.33.3130
- C. H. Chang, S. W. Huang, H. C. Yang, Y. H. Chou, and P. C. Li, "Reconstruction of ultrasonic sound velocity and attenuation coefficient using linear arrays: Clinical assessment,' Ultrasound Med. Biol., vol. 33, no. 11, pp. 1681-1687, 2007 https://doi.org/10.1016/j.ultrasmedbio.2007.05.012
- J. H. Kim, T. K. Song, and S. B. Park, "A pipelined sampled delay focusing in ultrasonic imaging systems," Ultrason. Imaging, vol.9, pp. 75-91, 1987 https://doi.org/10.1016/0161-7346(87)90007-1
- K. Jeon, M. H. Bae, S. B. Park, and S. D. Kim, "An efficient real time focusing delay calculation in ultrasonic imaging systems," Ultrason. Imaging, vol. 16, no. 4, pp. 231-248, Oct. 1994 https://doi.org/10.1006/uimg.1994.1014
- T. Kontonassios and J. Ophir, "Variance reduction of speed of sound estimation in tissues using the beam tracking method," IEEE Trans. Ultrason. Ferroelect. Freq. Contr., vol. 34, no. 5, pp. 624-530, Sept. 1987
- J. Ophir, Y. Yazdi, T. S. Lin, and D. P. Shattuck, "Optimization of speed-of-sound estimation from noisy ultrasonic signals," IEEE Trans Ultrason.Ferroelect. Freq. Contr., vol. 36, no. 1, pp.16-24, Jan. 1989 https://doi.org/10.1109/58.16964
- D. Napolitano, C. H. Chou, G. McLaughlin, T. L. Ji, L. Mo, D. DeBusschere, and R. Steins, "Sound speed correction in ultrasound imaging," Ultrasonics, vol. 44, suppl. 1, pp. e43-e46 Dec. 2006
- M. K. Jeong and S. J. Kwon, "An efficient method for estimating average speed of sound in ultrasound medical imaging,' J. Biomed. Eng. Res., vol. 19, no. 3, pp. 321-325, 1998
- J. H. Kim, M. H. Bae, and M. K. Jeong, "Study on velocity in-homogeneous effect in fat and its correction in ultrasound imaging system,' J. Biomed. Eng. Res., vol. 19, no. 1, pp. 9-17,1998
- M. E. Anderson, M. S. McKeag, and G. E. Trahey, "The impact of sound speed errors on medical ultrasound imaging,' J. Acoust. Soc. Am., vol. 107, no. 6, pp. 3540-3548, June 2000 https://doi.org/10.1121/1.429422
- D. Zaho and G. E. Trahey, "Comparison of image quality factors for phase aberration correction with diffuse and point targets: Theory and experiments,"IEEE Trans. Ultrason. Ferroelect Freq. Contr, vol. 38, no. 2, pp. 125-132, Mar. 1991 https://doi.org/10.1109/58.68469
- J. E. Wilhjelm, M. S. Jensen, T. Brandt, B. Sahl, K. Martinsen, S.K. Jespersen, and E. Falk, "Some imaging strategies in multiangle spatial compounding," in Proc. IEEE Ultrason. Symp.,2000, pp.1615-1618
- U. Bencharit, J. L. Kaufman, N. M. Bilgutay, and J. Saniie,"Frequency and spatial compounding techniques for improved ultrasonic imaging," in Proc. IEEE Ultrason. Symp., 1986, pp.1021-1026
- B. K. Seo, Y. W. Oh, H. R. Kim, H. W. Kim, C. H. Kang, N. J. Lee, J. H. Kim, B. J. Park, K. R. Cho, J. Y. Lee, K. Y. Lee, and J. W. Bae, "Sonographic evaluation of breast nodules: Comparison of conventional, real-time compound, and pulse-inversion harmonic images," Korean J. Radiol, vol. 3, no. 1, pp. 38-44, Mar. 2002 https://doi.org/10.3348/kjr.2002.3.1.38