• Title/Summary/Keyword: soft contact Lens

Search Result 120, Processing Time 0.025 seconds

The Change in Refractive Powers of Soft Contact Lenses Caused by the Deposition of Tear Proteins (누액 단백질 침착에 의한 소프트콘택트렌즈의 굴절력 변화)

  • Choi, Jin-Yong;Park, Jae-Sung;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.4
    • /
    • pp.383-390
    • /
    • 2011
  • Purpose: The present study was conducted to investigate whether refractive powers of soft contact lenses were induced by the deposition of tear proteins when wearing soft contact lenses. Methods: The soft contact lenses (material: etafilcon A, hilafilcon A and comfilcon A) with refractive powers of -1.00 D, -3.00 D, -5.00 D and -7.00 D were incubated in artificial tear for 1 day, 3 days, 5 days, 7 days and 14 days, respectively. After incubation, their refractive powers were measured by wet cell method with an auto-lens meter and their protein deposited on the lenses was determined by the method of Lowry. Results: Among three types of soft contact lenses, the most protein deposition was detected in ionic etafilcon A lens material and significant change of its refractive power was manifested. In other words, refractive powers of etafilcon A lenses firstly decreased after 1 day incubation in artificial tear and then gradually increased with increasing incubation period again. The observed change in refractive powers of all diopters of etafilcon A material was beyond the scope of standard error and bigger in the lens with lower optical power. On the other hand, non-ionic hilafilcon A showed less protein deposition as much as about 20% in etafilacon A and statistically significant increase of refractive powers with increasing incubation period in artificial tear. The change in refractive power of hilafilcon A was also beyond the scope of the standard of error when incubating in artificial tear and greater in the lens with lower diopter. The least protein deposit was shown in silicone hydrogel lens material, comfilcon A as approximately 10% of it in etafilcon A, indicating less change in refractive power within the standard range of error. Conclusions: The large change of refractive powers that was beyond the scope of standard error by the deposition of tear proteins on soft contact lenses was differently detected depending on lens materials in the current study. Thus, the deposition of tear proteins induced by longer period of lens wearing may be one of the causes that induces blurred vision, suggesting that soft contact lens wearers with the amount of tear proteins may need to choose proper lens material.

The Correlation Between Corneal Eccentricity and Radius Curvature by Fitting Status of Soft Contact Lens Wearer (소프트 콘택트렌즈 착용자의 피팅 상태에 따른 각막 이심률과 곡률반경과의 상관관계)

  • Han, Sun-Hee;Kim, Bong-hwan;Park, Jun-Sung;Baek, Su-won;Kwon, Sung Jin;Kim, Eun Kyoung;Yoon, Jung Na;Choi, So Min;Heo, A Jeong;Park, Eun Hye
    • Journal of Korean Clinical Health Science
    • /
    • v.4 no.4
    • /
    • pp.662-670
    • /
    • 2016
  • Purpose. Because of a recent increase in use of soft contact lens at younger ages, in the present study, the correlation between corneal eccentricity and radius of curvature and fitting types of contact lens was investigated. Methods. The study evaluated the fitting status of targets through lens centration, push-up test, dynamic lag test and static lag test of lenses usually worn by 49 men and women (98eyes) in their 20s to 30s who put on soft contact lenses. After evaluation, the subjects were classified into 3 categories by fitting status(steep, aligment and flat). The radius of corneal curvature in the naked eyes was measured by using keratometer. Moreover the corneal eccentricity in the nasal side, temporal side, superior side and inferior side was measured by using the device capable of measuring the corneal eccentricity. Results. The radius of corneal curvature and corneal eccentricity of soft lenses worn by subjects were higher in the order of steep fitting and flat fitting, and the higher average corneal curvature radius and corneal eccentricity is intend to be more steep fitting(p=0.051, p=0.052). The corneal eccentricity showed a tendency to nasal fitting type at the higher eccentricity and temporal fitting type at the smaller eccentricity, statistically significant difference was observed(p<0.05). The study showed there were low correlation that nasal and temporal side at steep fitting, superior side at normal fitting and 4side(nasal, temporal, superior, inferior) at flat fitting, therefore when the corneal eccentricity changed the radius of corneal curvature also changed. The corneal eccentricity and the radius of corneal curvature showed statistically significant difference at 4side and each fitting types(p<0.05). Conclusions. The results of this study, the fitting status, of wearer are based on radius of corneal curvature and corneal eccentricity, and if lens fitting would be done considering that, it seems to be useful in a soft contact lens prescription.

Factors in effecting the activities of the protein remover (단백질 제거제의 작용에 영앙을 미치는 요인)

  • Park, Mijung;Shin, Young Min;Chang, Ji Yeon;Kim, Daesoo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.2
    • /
    • pp.91-97
    • /
    • 2005
  • We investigated the question whether protein removing activities of enzyme cleaner - protein remover for soft contact lens - are associated with the material of soft contact lens as well as action time, temperature and pH of enzyme solution. We used a subtilisin cleaner as protein remover and estimated the protein amount remained on soft contact lens after using the subtilisin cleaner under the different conditions. The remained protein in soft contact lens was greatly decreased until treatment for 60min, but no significant differences were found from 60min to 24hr. The cleaning effect of the enzymatic treatment in the range of $15{\sim}30^{\circ}C$ was constant. however, there was a significant decline of the protein removing effect at $10^{\circ}C$ and less. The pH of the solution was also important for the efficacy of the enzymatic treatment. The activity of the enzyme cleaner was highest in pH 8.0 and significantly decreased a pH below 7. The pH dependence was found to be related to the conformational change of subtilisin. Furthermore, significant differences in the protein deposit removing efficacy of the subtilisin cleaner were found among the soft contact lens materials.

  • PDF

Analysis of Vertex Refractive Power Accuracy of Soft Contact Lens with Holder Type (홀더종류에 따른 소프트 콘택트렌즈의 정점굴절력 측정의 정확도 분석)

  • Lee, Min-Jae;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.2
    • /
    • pp.105-115
    • /
    • 2015
  • Purpose: The accuracy for measuring the refractive power of hydrogel contact lenses by spectacle lens holder and contact lens holder was evaluated. The accuracy for each sample was also analyzed with water content and diopter categories. Methods: The hydrogel contact lenses used for measurement were classified into three categories in water content (38%, 43%, 58%). Also, three diopter categories of refractive power were used such as -3.000 D, -7.000 D, -10.000 D. And also, the reliability of measurement results were evaluated by measuring refractive power with spectacle lens holder and contact lens holder using an Manual lensmeter. Results: In case of spectacle lens holder method, the average value of refractive power was -3.3273D for -3.0000 D, -7.1306 D for -7.0000 D and -10.2944 D for -10.0000 D, respectively. In case of contact lens holder method, the average value of refractive power was -3.1060 D for -3.0000 D, -7.0028 D for -7.0000 D and -10.2611 D for -10.0000 D, respectively. In measurement of all diopters, the accuracy of contact lens holder method was better than spectacle lens holder method. Conclusions: From these results, it is judged that the refractive power of soft contact lens by manual lensmeter with contact lens holder have a higher accuracy than spectacle lens holder.

The Difference of Tear Break-Up Time by the Fitting States of Soft Contact Lens in Normal and Dry Eyes (정상안과 건성안에서 소프트렌즈 피팅 상태에 따른 비침입성 눈물막 파괴 시간의 차이)

  • Jung, Da I;Lee, Heum Sook;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.4
    • /
    • pp.339-346
    • /
    • 2010
  • Purpose: The study was performed to compare the difference of non-invasive tear break-up time (NIBUT) with alignment or steep fitting of soft contact lens in normal and dry eyes. Methods: Total 40 eyes (aged 20~30 years) were classified to the normal (n=20) or dry eye group (n=20) by the diagnosis methods for dry eyes and worn soft contact lens (polymacon material) with alignment or steep fitting. NIBUTs of lens wearers were separately measured at the points of before wearing, immediately after wearing and after stabilization of tear film. Results: With alignment fitting, averaged NIBUT in the dry eye group after stabilization of tear film was not significantly different from that of the normal eye group. However, averaged NIBUTs in the normal and dry eyes had significant difference when measured immediately after lens wearing. However, the number of eyes having NIBUT less than 4.0 second was 30% higher compared to the number of normal eyes with steep fitting when measured immediately after wearing. Some shorten NIBUT in dry eyes with steep fitting was also shown after stabilization of tear film. Conclusions: These results suggest that wearing soft contact lens in dry eyes differently affect tear film compared to normal eyes. Thus, dry eyes need more advertent fitting for contact lens wearing because of unstable tear film.

Comparison of tear film break-up time and high order aberration according to soft contact lens material (소프트콘택트렌즈 재질에 따른 눈물막 파괴시간과 고위수차의 비교)

  • Kim, Bong-Hwan;Han, Sun-Hee;Kim, Hak-Jun;Bae, Sang-A;Son, Yu-Jin;Kim, Ji-Hyun;KIm, Hyun-Ji
    • Journal of Korean Clinical Health Science
    • /
    • v.7 no.1
    • /
    • pp.1232-1237
    • /
    • 2019
  • Purpose. In this study, two types of soft contact lenses with different materials were selected to compare the time of tear film destruction and high order aberrations before and after wearing. Methods. Thirty patients (60 eyes) in their 20s were included in this study. Two lenses with different materials, Group 4 (Etafilcon A) and Group 5 (Narafilcon A) were selected. Using aberration analyzer and keratometry, high-order aberration and tear film test (NIF-BUT, NIAvg-BUT) were performed before and after wearing. Results. When comparing the higher aberrations of the Etafilcon A and Narafilcon A lenses, the higher aberrations of the Narafilcon A lens were higher overall. For the initial tear film break-up time (NIF-BUT) after wearing, the Etafilcon A lens was reduced by 4.0 seconds and the Narafilcon A lens increased by 0.6 seconds. For the mean tear film break-up time (NIAvg-BUT) after wearing, the Etafilcon A lens decreased by 2.4 seconds and the Narafilcon A lens increased by 1.7 seconds. Conclusions. NIF-BUT and NIAvg-BUT of Narafilcon A lens were increased. The lens with relatively low water content and higher oxygen permeability than the lens with high water content has relatively less tear evaporation, which means that the time of destruction of the tear film is increased.

A Correlation between Axis-Rotation and Corneal Astigmatism in Toric Soft Contact Lens Fitting (토릭소프트렌즈 피팅 시 축 회전과 각막난시와의 상관관계)

  • Park, Hyung Min;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.2
    • /
    • pp.189-198
    • /
    • 2014
  • Purpose: The present has analyzed the correlation between the direction of lens and the amount of rotation upon soft toric contact lens fitting after classifying the corneal astigmatism. Methods: Soft toric contact lens was fitted on 114 with-the-rule astigmatic eyes with total astigmatism of at least -0.75 D in their 20s and 30s according to the fitting guideline of the manufacturer and the correlation between the astigmatic degree and the rotational direction/amount of rotation was analyzed by when keeping the eyes on the front and by changing the direction of gaze. As for re-orientation movement. The speed of lens re-orientation and total amount of lens rotation was compared and analyzed by corneal astigmatism after mis-location of lens of $45^{\circ}$ to temporal and nasal direction, respectively. Results: The positive correlations were shown between corneal astigmatism and the direction of lens rotation and between corneal astigmatism and the amount of lens rotation. Meanwhile, the amount of lens rotation was different by the direction of gaze however, there was no correlation with corneal astigmatism. The speed of lens re-orientation was fastest in the group of high astigmatic degree when the lens was mis-located to both temporal and nasal directions. Conclusions: For optimal axis stabilization of toric soft lens, it is proposed that the adjustment of fitting guideline considering corneal astigmatism is necessary since the current fitting guideline is only based on total astigmatism.

Contrast Sensitivity and Glare with Spherical and Toric Soft Contact Lenses in Low-astigmatic Eyes (구면과 토릭 소프트 렌즈로 교정한 약도 난시안의 대비감도와 눈부심)

  • Lee, Min-Ah;Kim, Hyun Jung;Kim, Jai-Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.1
    • /
    • pp.39-45
    • /
    • 2009
  • Purpose: The purpose of this study is to compare the visual performance by contrast sensitivity (CS) and disability glare (DG) in low astigmatic eyes corrected with toric soft lenses and other optical corrections. Methods: Twenty university students with myopia (-1.00 to -6.50D Sph. with astigmatism up to 1.50 cyl) were enrolled and corrected by five different methods: 1) soft toric lenses; 2) spherical soft contact lenses; 3) RGP lenses; 4) best spectacle corrected visual acuity; 5) spherical equivalent spectacles. All subjects had corrected vision acuity of 20/20 or better. Contrast sensitivity and disability glare were measured using the OPTEC 6500 contrast sensitivity view-in tester included the EyeView Functional Vision Analysis software at photopic or mesopic conditions with glare. Results: At photopic condition, best corrected spectacle wearers had the highest monocular contrast sensitivity at all spatial frequency followed by soft toric lenses, RGP lenses, spherical equivalent spectacles, and spherical soft contact lenses. However, all of them were in normal contrast sensitivity value at photopic condition. At mesopic condition with glare, toric soft lenses were the highest and followed by RGP lenses, spherical equivalent spectacles, best spectacle corrected visual acuity and spherical soft contact lenses. It was observed that spherical soft contact lens wearers demonstrated lower range than normal contrast sensitivity value at mesopic condition with glare. Conclusion: Toric soft lenses gave better visual performance than spherical soft lenses in low astigmatic eyes. Subjects requiring the use of contact lenses under mesophic conditions could benefit from toric soft lenses.

  • PDF

A Study on Improvement of Wettability and Comfort in Contact lens with Hyaluronic acid (Hyaluronic acid 함유 콘택트렌즈의 습윤성과 착용감 향상 효과 연구)

  • Kim, Hyun Jung;Kim, Soo-Hyun;Kim, Jai-Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.3
    • /
    • pp.255-264
    • /
    • 2011
  • Purpose: To study the effect of hyaluronic acid(HA), which was widely used in artificial tears, multi-purpose solution(MPS), cosmetics, and drug acting on the musculo-skeletal system, in wettability and comfort of contact lens, we compared HA including lens(+HA) with HA excluding lens(-HA) by clinical evaluation. Methods: During four weeks, the selected 28 university student volunteers who did not have any eye disease wore +HA contact lens on their right eyes, and -HA contact lens on their left eyes, and then compared right eyes to left eyes as control. After prescribing by spherical equivalent calculation, over-refraction by auto-refractometer, and contact lens wearing for two weeks and four weeks, tear evaluation, the anterior of eyes examination, fitting convenience evaluation, surface wetting test, surveys were checked up. Results: Compared with the control group (-HA contact lens), +HA contact lens provided better wetting properties. The amount of released tear in -HA contact lens group became less in four weeks than before, but that in +HA contact lens group showed no significant difference from the initial one. In terms of the redness in eye, there was no significant difference between +HA and -HA contact lens groups. Fitting of +HA contact lens on eye was much easier than the control, -HA contact lens. From the results of survey, comfort, wettability, ease of cleaning, and dryness of eye in +HA contact lens group were generally better than those of -HA group, but redness and contact lens handling showed little difference. Conclusions: The addition of HA in soft contact lens(+HA) may enhance the wettability of lens during lens wearing, resulted in the better comfortable wearing of lens eventually.

Changes in Optical and Surface Properties of Contaminated Soft Contact Lenses (표면 오염시 소프트콘택트렌즈의 재질에 따른 가시광선투과도 및 표면 변화)

  • Kim, Jungeun;Jung, Boyoung;Noh, Hyeran
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.1
    • /
    • pp.83-89
    • /
    • 2012
  • Purpose: This article was to study the optical and surface properties of soft contact lenses (SCL) exposed to eye make-ups. Methods: Rates of the light transmission of etafilcon A (HEMA based hydrogel lens) and lotrafilcon B (silicone based hydrogel lens) exposed to four different cosmetics over time were investigated. After cleansed with multi-purpose solution (MPS), rates of the light transmission and surface change of lens that were exposed to the cosmetics for 7 consecutive days were analyzed. Results: Visible light transmissions of all lenses exposed to cosmetics decreased to 93.35% (HEMA based hydrogel lens) and 90% (silicone based hydrogel lens) compared with those of the fresh SCLs, such as 97.8% and 96.4%, respectively. It was found that cosmetic residues from powder eye shadow and mascara attached to the lenses were not removed completely when cleansed with MPS. Especially with silicone based hydrogel lens, we found a decrease in visible light transmission of the lens and noticeable particles on lens surface imaged by SEM. Conclusions: Depending on types of eye make-ups and contact lens materials, make-ups were not completely eliminated with current cleansing methods and that caused a decrease in optical property and a change in surface property of the lenses.