DOI QR코드

DOI QR Code

The Correlation Between Corneal Eccentricity and Radius Curvature by Fitting Status of Soft Contact Lens Wearer

소프트 콘택트렌즈 착용자의 피팅 상태에 따른 각막 이심률과 곡률반경과의 상관관계

  • Han, Sun-Hee (Department of Optometry, Choonhae College of Health Science) ;
  • Kim, Bong-hwan (Department of Optometry, Choonhae College of Health Science) ;
  • Park, Jun-Sung (Department of Optometry, Choonhae College of Health Science) ;
  • Baek, Su-won (Department of Optometry, Choonhae College of Health Science) ;
  • Kwon, Sung Jin (Department of Optometry, Choonhae College of Health Science) ;
  • Kim, Eun Kyoung (Department of Optometry, Choonhae College of Health Science) ;
  • Yoon, Jung Na (Department of Optometry, Choonhae College of Health Science) ;
  • Choi, So Min (Department of Optometry, Choonhae College of Health Science) ;
  • Heo, A Jeong (Department of Optometry, Choonhae College of Health Science) ;
  • Park, Eun Hye (Department of Optometry, Choonhae College of Health Science)
  • 한선희 (춘해보건대학교 안경광학과) ;
  • 김봉환 (춘해보건대학교 안경광학과) ;
  • 박준성 (춘해보건대학교 안경광학과) ;
  • 백수원 (춘해보건대학교 안경광학과) ;
  • 권성진 (춘해보건대학교 안경광학과) ;
  • 김은경 (춘해보건대학교 안경광학과) ;
  • 윤정나 (춘해보건대학교 안경광학과) ;
  • 최소민 (춘해보건대학교 안경광학과) ;
  • 허아정 (춘해보건대학교 안경광학과) ;
  • 박은혜 (춘해보건대학교 안경광학과)
  • Received : 2016.08.17
  • Accepted : 2016.08.30
  • Published : 2016.12.31

Abstract

Purpose. Because of a recent increase in use of soft contact lens at younger ages, in the present study, the correlation between corneal eccentricity and radius of curvature and fitting types of contact lens was investigated. Methods. The study evaluated the fitting status of targets through lens centration, push-up test, dynamic lag test and static lag test of lenses usually worn by 49 men and women (98eyes) in their 20s to 30s who put on soft contact lenses. After evaluation, the subjects were classified into 3 categories by fitting status(steep, aligment and flat). The radius of corneal curvature in the naked eyes was measured by using keratometer. Moreover the corneal eccentricity in the nasal side, temporal side, superior side and inferior side was measured by using the device capable of measuring the corneal eccentricity. Results. The radius of corneal curvature and corneal eccentricity of soft lenses worn by subjects were higher in the order of steep fitting and flat fitting, and the higher average corneal curvature radius and corneal eccentricity is intend to be more steep fitting(p=0.051, p=0.052). The corneal eccentricity showed a tendency to nasal fitting type at the higher eccentricity and temporal fitting type at the smaller eccentricity, statistically significant difference was observed(p<0.05). The study showed there were low correlation that nasal and temporal side at steep fitting, superior side at normal fitting and 4side(nasal, temporal, superior, inferior) at flat fitting, therefore when the corneal eccentricity changed the radius of corneal curvature also changed. The corneal eccentricity and the radius of corneal curvature showed statistically significant difference at 4side and each fitting types(p<0.05). Conclusions. The results of this study, the fitting status, of wearer are based on radius of corneal curvature and corneal eccentricity, and if lens fitting would be done considering that, it seems to be useful in a soft contact lens prescription.

Keywords

References

  1. Lee JH, Lee KS, Chu BS. Contact lens prescribing pattern in korean during 2010 to 2013. J Korean Ophthalmic Opt Soc. 2014; 19(3): 323-329. https://doi.org/10.14479/jkoos.2014.19.3.323
  2. Lee JY, Youk DJ, Lee JY. A relationship between visible iris diameter and palpebral aperture size: Considered to solve uncomfortable feeling of soft contact lens. J Korean Ophthalmic Opt Soc. 2014;19(3):285-293. https://doi.org/10.14479/jkoos.2014.19.3.285
  3. Kading DL. A comprehensive guide to soft lens comfort. Contact Lens Spectrum. 2007; 22:20-32.
  4. Martin DK, Holen BA. Forces developed beneath hydrogel contact lenses due to squeeze pre -ssure. Phys Med Biol. 1986;31(6): 635-649. https://doi.org/10.1088/0031-9155/31/6/005
  5. Martin DK, Boulos J, Gan J, et al. A unifying parameter to describe the clinical mechanics of hydrogel contact lenses. Optom Vis Sci. 1989; 66(2):87-91. https://doi.org/10.1097/00006324-198902000-00005
  6. Lowther GE, Tomlinson A. Critical base curve and diameter interval in the fitting of spherical soft contact lenses. Am J Optom Physiol Opt. 1981;58:355-360. https://doi.org/10.1097/00006324-198105000-00002
  7. Dumbleton KA, Chalmers RL, Mcnally J. Bayer S, et al. Effect of lens base curve onl subjective comfort and assessment of fit with silicone hydrogel continuous wear contact lenses. Optom Vis Sci. 2002;79(10):633-637. https://doi.org/10.1097/00006324-200210000-00008
  8. Kim JH, Kim SR, Park M. The effects of corneal type and corneal astigmatism on tear volume between rigid gas permeable lens and the cornea. J Korean Ophthalmic Opt Soc. 2015; 20(2):141-150. https://doi.org/10.14479/jkoos.2015.20.2.141
  9. Park EH, Kim SR, Park M. A relationship between corneal eccentricity and stable centration of RGP lens on cornea. J Korean Ophthalmic Opt Soc. 2012;17(4):373-380.
  10. Carney LG. Corneal topography changes during contact lens wear. Contac Lens J. 1975;5:5-16.
  11. Young G. Ocular sagittal height and soft contact lens fitting. J Brit Cont Lens Assoc. 1992;15(1):45-49. https://doi.org/10.1016/0141-7037(92)80031-T
  12. Chun YY, Park SJ, Lee SJ. The changes of cornea refractive power, tear break-up time and intra-ocular pressure after steep fitted soft contact lenses wearing. Korean J Vis Sci. 2015;17(4):523-531. https://doi.org/10.17337/JMBI.2015.17.4.523
  13. Cho YK, Kim SW, Yu DS. Refractive power changes after removal of contact lenses. J Korean Ophthalmic Opt Soc. 2013;18(3): 279-289. https://doi.org/10.14479/jkoos.2013.18.3.279
  14. Oh HJ, Oh SJ, Kim JM, et al. The analysis of corneal pographic data in Korean students who live in Ilsan. Korean J Vis Sci. 2005;7(1): 63-72.
  15. Chang BS, Oh HJ, Kim JM, et al. The comparative analysis of corneal eccentricity between myopic and non-myopic group in Elementary, Middle and High school students who live in Ilsan. Korean J Vis Sci. 2006; 8(1):71-84.
  16. Jeon IC, Jeong WJ, Kang JH. Comparison of corneal asphericity with measuring range. J Korean Ophthalmic Opt Soc. 2012;17(4):469-476.
  17. Lim SG, Lee MH, Choi SM, et al. A relationship between corneal type, corneal astigmatism and lens fitting states and the stable centration of spherical RGP Lens. J Korean Ophthalmic Opt Soc. 2012;17(2):143-151.
  18. Kim SR, Park SI, Lee SE, et al. A comparison of lens centration on cornea with RGP lens fitting by the measured values using keratometer and corneal topography. J Korean Ophthalmic Opt Soc. 2011;16(1): 41-50.
  19. Wittenberg S. Effect of working distance on Intraocular pressure as measured with the NCT. Am J Optom Physiol Opt. 1974;51(5): 325-330. https://doi.org/10.1097/00006324-197405000-00005