• 제목/요약/키워드: smoke scale

검색결과 155건 처리시간 0.205초

음향 여기에 의한 혼합층 유동구조의 변화에 대한 연구 (The Study on Changes of Mixing Layer Caused by Acoustic Excitation)

  • 정양범
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제24권6호
    • /
    • pp.120-127
    • /
    • 2000
  • This study is concerned with evaluating the effects of acoustic excitation on the development of two stream mixing layer generated by split plate. The ratios of two velocities U1 and U2 either side of the splitter plate were such that $U_1/U_2$=1.0 (uniform flow) or $U_1/U_2$<1.0(shear flow). The mixing layers were disturbed acoustically through the edge of split plate. Quantitative data were obtained with hot-wire anemometry. Flow visualization with smoke-wire was also employed for qualitative study. the results show that the large scale structures of mixing layers are strongly affected by excitation frequency and amplitude in both uniform and shear flows. The maximum streamwise and vertical turbulent intensities of the excited flow fields are apt to be decreased as compared with those of without excitation. The flow characteristics of uniform flow are more influenced by acoustic excitation than those of shear flow.

  • PDF

실규모 연기제어 실험연구를 위한 Pre-Pilot Test Bed 구축 (Establishment of Pre-Pilot Test Bed for Real Scale Experiment Study in Smoke Management)

  • 김정엽;신현준;주상현
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2012년도 춘계학술발표회 초록집
    • /
    • pp.81-84
    • /
    • 2012
  • 건축물에서 화재가 발생할 경우 연기에 의한 요인이 인명피해의 주요 원인으로 파악되고 있다. 특히 건축물이 고층화, 복합화, 대형화되면서 화재시 연기에 취약한 건축물이 증가하고 있고, 또한 기존의 연기제어 설계기준이 개선되어야 할 필요가 발생하고 있다. 이러한 요구에 부응하기 위해서는 새로운 조건에 대한 연기확산 및 연기제어에 대한 수행되어야 하며, 이론 수치해석적 연구와 더불어 실제적인 실험적 연구가 되어야 한다. 한국건설기술연구원 화재안전연구센터에는 5층규모의 제배연 실험동이 건립되어 있으며, 다양한 건축물 조건 및 연기제어 방식에 따른 실규모의 실험적 연구가 가능하도록 설비가 구성되어 있다. 본 논문에서는 이러한 Pre-Pilot Test Bed의 구축현황과 관련 실험내용을 소개하고자 한다.

  • PDF

영상 처리 기법을 이용한 터널 내 화재의 고속 탐지 기법의 개발 (Development of High-speed Tunnel Fire Detection Algorithm Using the Global and Local Features)

  • 이병무;한동일
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2006년도 하계종합학술대회
    • /
    • pp.305-306
    • /
    • 2006
  • To avoid the large scale of damage when fire occurs in the tunnel, it is necessary to have a system to minimize the damage, and early discovery of the problem. In this paper, we have proposed algorithm using the image processing, which is the high-speed detection for the occurrence of fire or smoke in the tunnel. The fire detection is different to the forest fire detection as there are elements such as car and tunnel lightings and other variety of elements different from the forest environment. Therefore, an indigenous algorithm should be developed.The two algorithms proposed in this paper, are able to complement with each other and also they can detect the exact position, at the earlier stay of detection. In addition, by comparing properties of each algorithm throughout this experiment, we have proved the propriety of algorithm.

  • PDF

전산수치해석 기반 화재훈련 VR 시뮬레이터의 개발 (A Development of Fire Training Simulator Based on Computational Fluid Dynamics Simulation)

  • 차무현;이재경;박성환;최병일
    • 한국CDE학회논문집
    • /
    • 제14권4호
    • /
    • pp.271-280
    • /
    • 2009
  • An experience based training system concerning various fire situations which may result many casualties has been required to make rapid decision and improve the responsiveness. Recently, the necessity of virtual reality (VR) based training system which can replace a dangerous full-scale fire training and be easily adopted to the training or evaluation process is increasing. This study constructed tile virtual environment according to pre-defined scenarios, utilized the FDS(Fire Dynamics Simulator), three dimensional computational fire analysis program, to derive numerically simulated data on the propagation of fire. Finally, by visualizing the realistic fire and smoke behavior through virtual reality technique and implementing real-time interaction, we developed a VR-based fire training simulator. Also, in order to ensure the sense for tile real of a virtual world and reaI-time performance at the same time, we proposed appropriate data processing and space search algorithms, demonstrate d the value of proposed method through experiments.

Experimental Study on Fire Hazard of Residential Fires Before and After Sprinkler Activation

  • Sekizawa, Ai;Yanai, Eiji;Takemoto, Akio;Kozeki, Daisuke;Suzuki, Keiko
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1997년도 International Symposium on Fire Science and Technology
    • /
    • pp.376-383
    • /
    • 1997
  • Fire experiments were conducted in a real scale room which is assumed to be a residential living room under the various opening conditions and locations of wood crib fire source to study on fire hazard before and after sprinkler activation. Concentrations of oxygen and carbon monoxide, smoke density, and temperature were measured to look into environmental conditions in a room of fire origin. The response time of residential sprinklers was also examined in relation to distance between sprinkler heads and a fire source.

  • PDF

화재성능이 확보된 재생 폐자원 단열재의 활용 연구 (Study on application of recycled insulation-panel with fire-safety performance)

  • 박계원;정재군;김학용
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2010년도 추계학술발표회 자료집
    • /
    • pp.167-170
    • /
    • 2010
  • This study is aiming at analyzing correlation between flashover's time and maximum smoke production rate's time on sandwich panel specimens. For this analysis, KS F ISO 137481-1 has been performed for 23 kinds of sandwich panels which mainly consist of EPS, PIR, PUR, Glass wool and so on. KS F ISO 13784-1 represents real scale reaction-to-fire test and focuses on measuring flashover phenomenon rather than other tests as like ISO 5660-1 and SBI.

  • PDF

건축물 건설공사 시 화재안전계획 수립에 관한 연구 (A Study on the Fire Safety Plan for Building Construction)

  • 정명진;이명구;함은구
    • 대한안전경영과학회지
    • /
    • 제14권4호
    • /
    • pp.31-37
    • /
    • 2012
  • Recently buildings are constructed in larger and higher scales and becoming more complex. However from small to large scale buildings and on construction sites there still are fire safety accidents that occur continuously. Therefore to improve fire safety plan, examining the actual fire safety management and understanding fire risk analysis Using Fire Modeling through Computer Simulation. On this study, the permissible evacuation times were estimated for smoke fall, temperature, CO concentration, viability, etc. Fire safety management plans for fire safety were suggested.

도로터널 내 환기소 위치별 방재 효율에 관한 실험적 연구 (An experimental study of smoke extraction efficiency along with ventilation building location in the mad tunnel)

  • 이동호;김하영;윤찬훈;김진
    • 한국터널지하공간학회 논문집
    • /
    • 제12권3호
    • /
    • pp.215-222
    • /
    • 2010
  • 본 연구에서는 도로터널 화재 시 지하 및 지상 환기소의 방재 효율을 검토하기 위해 터널 축소모형실험을 실시하였다. 터널 모형은 Froude 상사를 기본으로 도로터널을 1/50로 축소하여 20 m의 모형 터널을 제작하였다. 방재 효율 분석에 적용된 연직갱은 설제 터널 설계시 고려된 두 가지 모형으로서 실터널 560, $280\;m^3/s$의 배연량을 1/50으로 상사하여 적용하였다. 결과로 모두 연직갱을 통한 CO 가스의 전량 배출이 가능한 것으로 분석되었다. 두 환기소의 CO 농도는 지상 환기소가 지하 환기소 보다 2.23~2.73 ppm 작게 배출되었다. 그리고 지상 환기소의 경우 터널 벽면의 냉각효과로 인해 화재 후 온도의 상승이 지하 환기소보다 $0.53{\sim}0.94^{\circ}C$ 낮게 나타났다. 이상의 축소모형 환기소 내 CO농도 및 온도변화의 분석 결과, 방재적인 측면에서 볼 때 도로터널 내 환기소의 위치는 지하보다 지상에 위치하는 것이 유리할 것으로 판단되었다.

복층터널내 화재특성에 대한 실험적 연구 (Experimental Study on the Fire Behavior in Double Deck Tunnel)

  • 박진욱;유용호;김휘성;박병직
    • 한국화재소방학회논문지
    • /
    • 제30권2호
    • /
    • pp.75-80
    • /
    • 2016
  • 최근 도시의 거대화 및 과밀화의 영향으로 교통정체가 심해지고, 이로 인한 경제적 손실이 막대하게 증가하고 있는 실정이다. 따라서 대도시 공간의 효율적인 활용 방안으로 현재 국내외 도심지 터널이 복층터널로 계획되고 운영되는 추세이다. 그러나 복층터널의 경우 층고의 감소로 인해 터널 내부에서의 차량 화재시 일반 도로터널에 비해 더 많은 양의 연기 및 검탱이 발생될 것으로 예측되기 때문에 기존의 일반 도로터널을 대상으로 구축된 설계화재강도나 연기발생량을 적용하여 설계하고 운영하는 것은 바람직하지 않다. 따라서 본 연구에서는 복층터널 설계시 유용한 설계화재곡선 제시를 위한 연구의 일환으로 실규모 차량화재실험을 수행하여 복층터널내 화재 특성 데이터를 획득하고 분석하였다. 실험은 승용차 1대의 화재상황과 2대의 화재상황, 두 가지 상황을 구현하여 수행하였으며, 실험 결과로부터 화재강도는 승용차 1대에서는 최대 2.4MW, 승용차 2대에서는 최대 3.5MW가 나타났다.

일개 대학생 흡연자의 금연 생각과 금연의도가 건강증진행위와 우울인지에 미치는 영향에 대한 경로분석 (Pathway Analysis on the Influence of Health Promoting Behavior(HPB) and Depression Cognitive Scale(DCS) on Smoking Cessation Thoughts and Intention to Quit Smoking of College Students who Smoke)

  • 김희정;주세진;김경숙;김미옥;유미;최정현
    • 한국산학기술학회논문지
    • /
    • 제14권4호
    • /
    • pp.1830-1840
    • /
    • 2013
  • 연구는 흡연 대학생의 금연 생각과 금연 의도, 건강증진행위와 우울인지를 파악하고 금연생각과 금연의도, 건강증진행위, 우울인지의 경로를 검증하기 위하여 시도되었으며 2012년 4월 천안시 소재 N대학에 재학 중인 흡연 대학생 160명의 설문지를 분석하였다. 연구결과 금연에 대한 관심/욕구는 금연생각, 금연의도, 건강증진행위와 유의한 차이를 보였고(p<.001) 전공에 따라 금연의도(p=.034)와 건강증진행위(p=.044)는 유의한 차이를 보였다. 본 연구에서 설정한 대안 모형의 경로는 금연의도는 건강증진위를 매개로하여 우울인지에 영향을 주고 금연생각은 우울인지에 영향을 주는 경로 모형이다. 대안 모형의 적합도는 ${\chi}^2$ 1.172, p.279로 GFI .996, RMSEA .033, CFI .998, NFI .987로 나타났고 금연의도가 높을수록 건강증진행위가 유의하게 높아지며 건강증진행위가 높을수록 우울인지가 유의하게 낮아지는 것으로 나타났으며 금연생각이 높을수록 우울인지가 유의하게 낮아지는 것으로 나타났다.