• Title/Summary/Keyword: small water system

Search Result 1,321, Processing Time 0.032 seconds

Implementation of a High Power Amplifier using Low Loss Radial Power Combiner and Water Cooling System (저 손실 레디알 전력 결합기와 수냉 시스템을 이용한 고전력 증폭기 구현)

  • Choi, Sung-Wook;Kim, Young
    • Journal of Advanced Navigation Technology
    • /
    • v.22 no.4
    • /
    • pp.319-324
    • /
    • 2018
  • In this paper, a high power amplifier using RF power solid-state semiconductor is implemented to overcome a problem of plasma generator which has the low efficiency, short life span, the difficult maintenance and the high-operation cost. This power amplifier consists of a radial combiner of low-loss and high power operation and the sixteen 300 W power amplifiers to obtain 3 kW output power for high power operation implemented in semiconductors at industrial scientific medical (ISM) band of 2.45 GHz. In addition, this amplifier overcomes the problem of heat generation due to high power by applying a water-cooled structure to the individual amplifiers. This power amplifier, which is made up of a small system, achieves 50% efficiency at the desired output.

Experiments of Water Mist System Application for Rack Storage (랙크식 창고에 대한 미분무 시스템 적용성 실험)

  • Myoung, Sang-Yup;Kim, Jong-Hoon
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.4
    • /
    • pp.627-637
    • /
    • 2020
  • Purpose: This experimental study was conducted to find out whether a water-mist fire suppression system can be applied to C.E.P., a representative combustible material of a rack storage. Method: First, it was confirmed whether the water-mist fire-extinguishing system used in this experiment was capable of extinguishing oil fires. After that, the C.E.P. boxes were loaded in the same small space as used in the oil fire experiment, and then the experiment was conducted on three scenarios; door opening, door closing, and door closing and increasing the internal load. The scenario was set considering the opening and space size conditions, which are important factors for the water-mist fire suppression. Result: Oil fire suppression tests have shown that fires are well extinguished in both the door open and closed conditions. In case of a fire of C.E.P. boxes in the same space condition as an oil fire, the fire was not extinguished in the door open condition. Fires were extinguished in the case with the door closed condition, but the afterglow was confirmed. Conclusion: In the oil fire suppression test, a water-mist fire suppression system extinguished a fire in both the door open and closed conditions. However, for the C.E.P fire, it was possible to extinguish only under the door closed condition, and there was a possibility of re-ignition.

Manufacturing of High Water-Resistant Particleboard by Combining Use of Urea Resin and EMDI Resin (요소수지와 EMDI수지의 복합이용에 의한 고내수정 파티클보드의 제조)

  • Park, Jong-Young
    • Journal of the Korean Wood Science and Technology
    • /
    • v.26 no.1
    • /
    • pp.97-105
    • /
    • 1998
  • This study examined the combined using effects of urea-formaldehyde (UF) resin and emulsifiable methylene diphyenyl diisocyanate (EMDI) resin to overcome performance limit of three-layer particleboards commonly made by UF resin. Two adhesive adding methods were applied with three types of resin combination system to each layer of particleboards. The one was simultaneously spreading method with emulsified compound resin (UF and EMDI) while the other was separately spreading method with unemulsified EMDI resin after UF resin spreading. The performance of particleboards bonded with 2% EMDI resin to the inner layers(IL) were similar to that of controls bonded with 8% UF resin. In the case of the emulsified compound resin application to the all layers of particleboards, there were marked reinforcing effects of EMDI resin, although a small amount of EMDI resin was mixed with UF resin. Especially bending MOR after 24 hours cold water-immersion and thickness swelling after 2 hours hot water-immersion of compound resin-bonded particleboards were remarkably different from those of pure UF resin-bonded particleboards. It was found that separately spreading method with unemulsified EMDI resin was more effective than simultaneously spreading method with emulsified compound resin to sustain the internal bond strength of particleboards after 24 hours cold water-immersion. In the resin combination systems to outer layers/inner layers of particleboards, water resistance and strength properties were superior in order of UF+EMDI/UF+EMDI > UF/UF+EMDI > UF/UF. And water resistance of particleboards was greatly dependent upon EMDI resin level in any adhesive adding method.

  • PDF

Treatment Technologies for Arsenic Removal from Groundwater: review paper (비소오염지하수의 현장처리기술동향: 리뷰)

  • Bang Sunbaek;Choe Eun Young;Kim Kyoung-Woong
    • Economic and Environmental Geology
    • /
    • v.38 no.5 s.174
    • /
    • pp.599-606
    • /
    • 2005
  • Arsenic is a significantly toxic contaminant in groundwater in many countries. Numerous treatment technologies have been developed to remove arsenic from groundwater. The USEPA recommends several technologies as the best available technology (BAT) candidates for the removal of arsenic. Based on the USEPA classification, arsenic treatment technologies can be divided into four technologies such as precipitation, membrane, ion exchange, and adsorption technology. The recent amendment of arsenic drinking water standard from 50 to $10{\mu}g/L$ in the United States have impacted technology selection and application for arsenic removal from arsenic contaminated groundwater. Precipitation technology is most widely used to treat arsenic contaminated groundwater and can be applied to large water treatment facility. In contrast, membrane, ion exchange, and adsorption technologies are used to be applied to small water treatment system. Recently, the arsenic treatment technology in the United States and Europe move towards adsorption technology to be applied to small water treatment system since capital and maintenance costs are relatively low and operation is simple. The principals of treatment technologies, effect factors on arsenic removal, arsenic treatment efficiencies of real treatment systems are reviewed in this paper.

A Practical Research for Mode Efficient Utilization of Estuary Reserviors in the South-Western Part of Korea (우리나라 서남부지역 담수호의 효율적 이용방안)

  • Kim, Hyeon-Yeong;Seo, Yeong-Je
    • Journal of Korea Water Resources Association
    • /
    • v.31 no.4
    • /
    • pp.385-396
    • /
    • 1998
  • The south-western part of Korea is situated in an unbalance of water supply and demand relating to the Keum, Mankyung, Dongjin and Youngsan River and their estuary reservoirs. For example, the Keum River estuary reservoir is discharging the larger amount of yearly runoff into the sea due to the small storage capacity, while Saemankeum estuary reservoir which is under construction, has the smaller runoff comparing with its strorage capacity. And the downstream area of the Youngsan River, such as Youngkwang, Youngam are deficient in water due to larger demand and smaller supply. In order to solve the above unbalanced water supply and demand and also to improve the water use effciency, the Hierarchical Operation Model for Multi-reservoir System(HOMMS) has been developed and applied to analyze the multi-reservoir operation assuming that the above reservoirs were linked each other. The result of this study shows that $2,148{\times}106\;\textrm{m}^3$ of annual additional water requirement for agricultural and rural water demands are required in this region at 2011 of target year, and these demands can be resolved by diverting and reusing $1,913{\times}106\;\textrm{m}^3$ of the released water from the estuary reservoirs into the sea.

  • PDF

Study on Construction of Flood Hazard Information Support System based on Scenario (시나리오 기반 홍수위험정보지원시스템 구축 방안 연구)

  • Goo, Sin-Hoi;Jin, Kyeong-Hyeok;Cheong, Tae-Sung
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2010.04a
    • /
    • pp.389-393
    • /
    • 2010
  • The Objective of this study was to develop a system for visualizing inundation area by using 1-D numerical model analyzing damage information such as inundation area, facilities, land usages, population, building, loads. In this study, we have reviewed hydraulic models to select a flood model for simulation of discharges, water depths and velocities. The study area is Namhan River from Youngwol to Paldang Dam which had a flood damage on upper and below regions of Chungju Dam by a storm event in 2006. At the first, we developed the DB system base on GIS thematic map, ortho images, cadastral maps to analyze flood damages and support decisions making. Changing the boundary conditions such as discharge at the gauging stations, flood simulations were performed and then damages were extracted from the databases information support system based on 1-D numerical hydraulic model, it is expected to be able to analyze flood damages and support a decision making for reduce flood relate damages. In the future, the system developed in this study could be applied for flood forecasting system of small scaled streams.

  • PDF

Reference project of Small hydro power system Using low head (보(洑)를 이용한 '저낙차대유량'소수력발전소 건설)

  • Shin, Hong-Seob;Park, Kyung-Hwan;Song, In-Gyu
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.2112-2113
    • /
    • 2011
  • 우리나라는 연평균 강수량이 1,245mm로써, 비교적 강수량이 풍부하고 전국토의 2/3가 산지로 구성되어 있어 지형적 및 수문학적으로 수력자원 부존량이 많은 편이다. 하지만 수력자원 활용을 통한 발전소 건설은 매우 미미한데 이는 수력발전소 개발지점이 제약되어 있고 개발지점의 가동율 또한 매우 낮아 경제성 확보가 어렵기 때문이다. 수력발전은 전력수요 급증 시 부하 평준화 효과와 석유 수입대체 및 환경 친화적인 에너지원이라는 장점이 있다. 따라서 국산화된 수차발전시스템의 사용으로 초기투자비를 낮추고 하천형 수력발전소 건설을 통하여 가동율을 높인다면 우리나라의 수력발전사업은 크게 활성화 될 것이다. 본 논문에서는 하천형 수력발전소 시공사례를 통하여 주요 시공사례를 소개하고, 하천공사의 특징으로 인하여 설계 및 시공 시 반영해야 할 사항에 대해 몇 가지 소개하였다. 표준화를 통하여 건설비용을 절감, 발전 단가의 기준가격 현실화를 통한 재정적인 지원 및 법규 정비를 통한 제도적인 도움 이 세가지를 해결한다면 경쟁력 있는 소수력발전소 건설이 가능 할 것이다.

  • PDF

Solid-salt pressure-retarded osmosis with exothermic dissolution energy for sustainable electricity production

  • Choi, Wook;Bae, Harim;Ingole, Pravin G.;Lee, Hyung Keun;Kwak, Sung Jo;Jeong, Nam Jo;Park, Soon-Chul;Kim, Jong Hak;Lee, Jonghwi;Park, Chul Ho
    • Membrane and Water Treatment
    • /
    • v.6 no.2
    • /
    • pp.113-126
    • /
    • 2015
  • Salinity gradient power (SGP) systems have strong potential to generate sustainable clean electricity for 24 hours. Here, we introduce a solid-salt pressure-retarded osmosis (PRO) system using crystal salt powders rather than seawater. Solid salts have advantages such as a small storage volume, controllable solubility, high Gibbs dissolution energy, and a single type of water intake, low pretreatment costs. The power densities with 3 M draw solutions were $11W/m^2$ with exothermic energy and $8.9W/m^2$ without at 35 bar using a HTI FO membrane (water permeability $A=0.375L\;m^{-2}h^{-1}bar^{-1}$). These empirical power densities are ~13% of the theoretical value.

Passive, semi-active, and active tuned-liquid-column dampers

  • Chen, Yung-Hsiang;Ding, Ying-Jan
    • Structural Engineering and Mechanics
    • /
    • v.30 no.1
    • /
    • pp.1-20
    • /
    • 2008
  • The dynamic characteristics of the passive, semi-active, and active tuned-liquidcolumn dampers (or TLCDs) are studied in this paper. The design of the latter two are based on the first one. A water-head difference (or simply named as water head in this paper) of a passive TLCD is pre-set to form the so-called semi-active one in this paper. The pre-set of water head is released at a proper time instant during an earthquake excitation in order to enhance the vibration reduction of a structure. Two propellers are installed along a shaft inside and at the center of a passive TLCD to form an active one. These two propellers are driven by a servo-motor controlled by a computer to provide the control force. The seismic responses of a five-story shear building with a passive, semiactive, and active TLCDs are computed for demonstration and discussion. The responses of this building with a tuned mass damper (or TMD) are also included for comparison. The small-scale shaking-table experiments of a pendulum-like system with a passive or active TLCD to harmonic and seismic excitations are conducted for verification.

A study of the relationship between Sedimentation and Storage requirments of reservoirs (저수지 내용적 감소가 필요저수량에 미치는 영향에 관한 연구)

  • 신일선;김재곤;김시원
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.21 no.1
    • /
    • pp.53-62
    • /
    • 1979
  • Since the first installation of irrigation Systems in Korea , a large number of small and medium sized reservoirs have been constructed as the main water sources Some 412, 000 ha are at present irrigated from these sources of supply. Many of the reservoirs were designed in accordance with old low standards and have in addition suffered a loss in capacity through sedimentation. At the same time, water demand has increased with the in troduction of high yielding varieties of rice. The combination has resulted in severe water deficits. To study the problem, 16 sample reservoirs have been surveyed and analysed. The results of the study are summarized be low: 1. Average decrease in reservoir capacity from the installation to present-8% 2. Average soil erosion loss (m$^3$/km$^2$/year) is 536 m$^3$/km$^2$/year and average erosion depth of soil is 0. 5mm per year. 3. No relationship, between reservoir capacity per unit of watershed (m$^3$/km$^2$) and soil erosion loss was found. 4. Increases are required in reservoir capacity: 15.8% due to the introduction of HYV's; 16.6% due to the change of system losses from 10%to 25% The conclusion to be drawn from the above results is that existing reservoir capacity should be increased by an average of 32%. The unit storage capacity to be adopted should be 661 mm

  • PDF