• 제목/요약/키워드: skin measurement

검색결과 625건 처리시간 0.029초

적외선, 생물광자 및 GDV 측정의 한의학적 비교 소개 (Comparative Introduction of IR, Biophoton, and GDV on the Application of Korean Medicine Based on Their Recent Progress)

  • 이승호;이혜정
    • Korean Journal of Acupuncture
    • /
    • 제27권2호
    • /
    • pp.159-181
    • /
    • 2010
  • Objectives : The purpose of this study is to introduce and examine the possibilities of infrared (IR) imaging, biophoton detection and gas discharge visualization(GDV) as diagnostic tools in Korean Medicine. Methods : To review the basic mechanism and measurement methods of three modalities, concepts in physics were introduced. Physical backgrounds of IR, biophoton and GDV were briefly explained based on recent research papers. Simple electronics was employed for relevant detectors. In order to find the relation between Korean Medicine and these methods, papers on their applications were reviewed. Opinions from the experts on each modality were obtained from their papers and private communications. Results and Conclusions : IR imaging has been used as an auxiliary diagnostic tool but there are some rooms for the improvement for clinical applications. Experimental confirmation of the meridian activation by a moxa cigar is necessary for its verification. Biophoton is not correlated with human skin temperature but it has a circadian rhythm. Biophoton and GDV have a negligible relation if any. Therefore there are no correlations among three modalities in terms of basic mechanisms. But their clinical relations are yet to be scrutinized. Biophoton and GDV need more rigorous clinical tests before they can be used as diagnostic tools.

맥 센서 어레이(array)의 실리콘(silicone) 코팅 두께에 따른 센서 간 간섭효과 (Interference Effects on the Thickness of a Pulse Pressure Sensor Array Coated with Silicone)

  • 전민호;전영주;김영민
    • 센서학회지
    • /
    • 제25권1호
    • /
    • pp.35-40
    • /
    • 2016
  • Pulse diagnosis is one of the representative diagnostic methods in Oriental medicine. In this study, a pulse pressure sensor array coated with silicone, which includes 6 piezo-resistive sensors and 1 thermistor, is fabricated for pulse measurement. It is necessary to coat the pulse sensor array with silicone to avoid the fracture or damage of pressure sensors when the sensor is in contact with the skin and a constant pressure is applied. However, the silicone coating on the pulse sensor array can cause signal interference among the sensors in the pulse sensor array. The interference number (IN), a calculation for expressing the degree of interference among channels, is changed according to the silicone thickness on the pulse sensor array. The IN is increased by a thick silicone coating, but the fabrication error, an important index for the mass production of the sensor array, is reduced by the thickness of the silicone coating. We propose that the thickness of the silicone on the pulse sensor array is an important consideration for the performance of the fabricated sensor and manufacturing repeatability.

자기혼합형 반도체 레이저를 이용한 혈류측정 시스템 설계 및 평가 (Design and Evaluation of Blood flow Measurement Using Self-mixing type Semiconductor Laser)

  • 김덕영;이진;김세동;고한우;김성환
    • 대한의용생체공학회:의공학회지
    • /
    • 제17권4호
    • /
    • pp.499-506
    • /
    • 1996
  • Blood flow velocimeter is an essential device to measure the blood flow in skin tissue. In this study, we developed a high-speed LDV(laser Doppler Velocimeter) that has real time processing capability using a DSP(digital signal processing) chip and is able to continuously measure information about blood-flow based on a noninvasive method using self-mixing type laser diode. This LDV system has a simpler structure than any other typical blood flow velocimeter and is composed of new self-mixing probe, stabilizer circuits DSP board, and interf'ace boule We measured velocity of speaker-unit by operational frequencies to identify Doppler effect of this system, performed clinical experiment on bare finger tip and compared it with a commercial euipment BPM403A(USA).

  • PDF

청포도 즙의 첨가가 곤약젤리의 품질특성에 미치는 영향 (Effects of Adding Green Grape Juice on Quality Characteristics of Konjak Jelly)

  • 전재은;이인선
    • 한국식생활문화학회지
    • /
    • 제34권5호
    • /
    • pp.629-636
    • /
    • 2019
  • This study examined the quality characteristics of jelly prepared with green grape juice (GJ). The pH, $^{\circ}Brix$ value, color, texture, and sensory evaluation of the jelly were measured. The pH of the jelly significantly decreased with increasing amount of GJ over the range of 3.25-5.27. The $^{\circ}Brix$ value of the jelly showed a significantly higher result as the amount of GJ increased (p<0.001). Lightness (L) and redness (a) decreased with increasing amount of GJ, and yellowness (b) increased. In the texture measurement, the GJ-100 sample group with a high substitute rate of GJ showed high hardness, gumminess, and chewiness (p<0.001). The results of principal component analysis (PCA) showed that the sample groups with high GJ content were classified as having relatively strong yellowness, sweet aroma, metallic aroma, grassy aroma, sweetness, sourness, green grape skin taste, and astringency. In the acceptance test, the GJ-50 sample group was evaluated to be high in flavor (p<0.001) and overall acceptance (p<0.01). However, sample groups consisting of 50% or more GJ were evaluated to be significantly strong in terms of astringency. Therefore, further study needs to be conducted about improving astringency in the future.

An Image Quality Evaluation Model for Optical Strip Signal-to-Noise Ratio in the Target Area of High Temperature Forgings

  • Ma, Hongtao;Zhao, Yuyang;Feng, Yiran;Lee, Eung-Joo;Tao, Xueheng
    • Journal of Multimedia Information System
    • /
    • 제8권2호
    • /
    • pp.93-100
    • /
    • 2021
  • Under the time-varying temperature, the high-temperature radiation of forgings and the change of reflection characteristics of oxide skin on the surface of forgings lead to the difficulty of obtaining images to truly reflect the geometric characteristics of forgings. It is urgent to study the clear and reliable acquisition method of hot forging feature image under time-varying temperature to meet the requirements of visual measurement of hot geometric parameters of forgings. Based on this, this chapter first puts forward the quality evaluation method of forging feature image, which provides guarantee for the accurate evaluation of feature image quality. Furthermore, the factors that affect the image quality, such as the radiation characteristics of forgings and the photographic characteristics of cameras, are analyzed, and the imaging spectrum which can effectively suppress the radiation intensity of forgings is determined. Finally, aiming at the problem that the quality of image acquisition is difficult to guarantee due to the drastic change of radiation intensity of forgings under time-varying temperature, an image acquisition method based on minimum signal-to-noise ratio (SNR) based laser light intensity adaptation is proposed, which significantly improves the definition of feature light strips in forging images at high temperature, and finally realizes the clear acquisition of feature images of large-scale hot forging under time-varying temperature.

Radiation Exposure Dose of Handlers Using 18F-FDG in Small Animal Image Acquisition Experiments

  • Ik Soo Kim;Sun Young Yoon;Hwa Yeon Yeo
    • 방사선산업학회지
    • /
    • 제17권3호
    • /
    • pp.233-238
    • /
    • 2023
  • This study was conducted to confirm the safety of the operator's radiation exposure in the micro PET-CT image acquisition experiment using the 18F-FDG. The usage of 18F-FDG and the exposure dose of handlers were measured at University B in Metropolitan City A, which uses 18F-FDG for micro PET-CT image acquisition. As a result of the measurement, the exposure dose is far below the effective dose limit of radiation workers, 50 mSv per year, and the equivalent dose limit of 500 mSv per year for hands, feet, and skin. has been measured Since these exposure doses can be further increased according to the number of times of use of 18F-FDG, it is judged that the exposure dose compared to the handling amount of 18F-FDG shown in this study can be used as reference data. In addition, as changed environments such as the use of materials other than unopened RI are occurring in education and research environments, such as the use of 18F-FDG at University B, radiation exposure with more interest in safety management by checking the factors of radiation exposure of the handler concerned We will always do our best to reduce it.

유방암 환자의 수술 중 방사선치료 시 피부선량 측정을 통한 안전성 평가 (Evaluation of safety by skin dosimetry in Intraoperative Radiotherapy for breast cancer patients)

  • 정인호;김준원;박광우;하진숙;전미진;조윤진;김세준;김종대;신동봉
    • 대한방사선치료학회지
    • /
    • 제27권1호
    • /
    • pp.13-22
    • /
    • 2015
  • 목 적 : 유방암 환자를 대상으로 Intrabeam$^{TM}$ system을 이용한 수술 중 방사선치료(Intraoperative Radiotheray, IORT)를 국내에 처음 도입하는데 있어 광자극형광선량계(Optically Stimulated Luminescent Dosimeter, OSLD)를 이용한 피부선량측정을 통해 Intrabeam$^{TM}$ system의 안정성을 평가하고자 한다. 대상 및 방법 : 본원에서 2014년 8월부터 2015년 2월까지 유방보존술(breast-conserving surgery, BCS)후 Intrabeam$^{TM}$ system을 이용하여 수술 중 방사선치료(IORT)를 시행한 30명의 유방암 환자를 대상으로 진행하였다. 처방선량은 applicator 표면을 기준으로 20 Gy로 설정하여 1 cm 떨어진 지점에 약 5 Gy의 선량이 전달될 수 있도록 하였다. 종양 크기에 따라 applicator의 크기를 결정하였고 치료시간은 applicator의 크기에 따라 18~40분으로 설정되었다. 피부 절개면에서 Superior, Inferior, Lateral, Medial 4방향에 applicator를 중심으로부터 0.5 cm와 1.5 cm지점에 광자극형광선량계(OSLD)를 각각 부착하였다. 각 방향에 따라 U1,U2(Superior), D1,D2(Inferior), L1,L2(Lateral), M1,M2(Medial)로 총 8지점을 지정하였다. 각 지점에서의 측정값과 모든 지점의 평균값 및 최고값, 최저값을 산출하여 비교분석 하였다. 결 과 : Intrabeam$^{TM}$ system 50kVp X-ray source를 이용한 수술 중 방사선치료(IORT)시 OSLD의 측정 결과 U1 $2.23{\pm}0.80Gy$, U2 $1.54{\pm}0.53Gy$, D1 $1.73{\pm}0.63Gy$, D2 $1.25{\pm}0.45Gy$, L1 $1.95{\pm}0.82Gy$, L2 $1.38{\pm}0.42Gy$, M1 $2.03{\pm}0.70Gy$, M2 $1.51{\pm}0.58Gy$로 나타났으며 maximum값은 U1지점에서 4.34 Gy, minimum값은 M2지점에서 0.45 Gy로 나타났다. 전체 환자 중 13.3 %(N=4/30) 환자에서 4 Gy를 초과하는 측정값이 나타나 그 원인을 분석하였다. 결 론 : 본 연구를 통해 현재 본원에서 도입한 Intrabeam$^{TM}$ system을 이용한 수술 중 방사선치료(IORT)는 모든 환자의 피부선량값이 5 Gy미만으로 측정된 것으로 보아 그 안전성이 확인되었다. 피부선량이 4 Gy를 초과한 환자의 데이터 분석을 통해 breast volume이 상대적으로 작은 사이즈의 유방암환자의 경우 피부선량이 증가하는 경향을 보여 수술 중 방사선 치료 대상 환자 선정시 종양의 크기와 위치 뿐만 아닌 breast volume 값 등을 고려하여 피부에 전달되는 선량값이 기준값을 초과하지 않도록 주의 하여야 한다.

  • PDF

전신방사선조사(TBI)시 다이오드 측정기(Diode detector) 및 열형광선량계(TLD)를 이용한 골조직 선량감쇄에 대한 고찰 (A study on dose attenuation in bone density when TBI using diode detector and TLD)

  • 임현실;이정진;장안기;김완선
    • 대한방사선치료학회지
    • /
    • 제15권1호
    • /
    • pp.67-77
    • /
    • 2003
  • I. 목적 전신방사선조사(TBI)시 균등한 선량을 조사할 목적으로 사용되는 각 신체부위별 보상체(compensator) 두께의 결정은 열형광선량계(TLD)를 이용하여 표면선량(surface dose)를 측정하고, 심부선량(depth dose)으로 환산하는 방법을 주로 이용한다. 그러나 이와 같은 방법은 골(bone) 조직에 대한 선량감쇄(dose attenuation)의 영향이 고려되지 않아 신체중심부에서의 정확한 심부선량을 알 수가 없다. 이에 본 연구에서는 열형광선량계와 다이오드측정기(Diode detector)로 표면선량과 심부선량을 동시에 측정하여 골조직에서의 선량감쇄 영향을 알아보고자 한다. II. 대상 및 방법 실험은 본원에서 TBI 치료를 받은 5명의 환자를 대상으로 실시하였으며, 측정장비로는 Siemens Mevatron 10MV X-ray, TLD(Harshaw 5500), Diode detector(Sun Nuclear)를 사용하였다. 선량 조사방법은 복부의 배꼽(umblicus)를 중심으로 하여 이문대향법(Bilateral)으로 150cGy가 조사되도록 하였다. 측정방법은 열형광선량계로 두부, 경부, 대퇴부, 슬관절, 족관절, 부위의 표면선량을 측정하였으며, 이 가운데 대퇴부, 슬관절, 족관절에서는 중심부 선량측정이 가능하여 동시에 심부선량을 측정하였다. 또한 실험대상자 중 3명의 환자는 상기와 같은 부위(두부, 경부, 대퇴부, 슬관절, 족관절)에 다이오드측정기로 심부선량을 측정하였다. III. 결과 TLD로 측정한 표면선량을 심부선량으로 환산한 값은 두부, 경부, 대퇴부, 슬관절, 족관절에서 각각 $92.78{\pm}3.3,\;104.34{\pm}2.3,\;98.03{\pm}1.4,\;99.9{\pm}2.53,\;98.17{\pm}0.56$ 이었고, 중심부 심부선량 측정이 가능한 대퇴부, 슬관절, 족관절에서는 각각 $86{\pm}1.82,\;93.24{\pm}2.53,\;91.50{\pm}2.84$로 나타났다. 따라서 표면선량과 중심부 심부선량 비교가 가능한 대퇴부, 슬관절, 족관절에서의 TLD의 측정치를 비교해보면 부위에 따라 최소 $6.67\%{\sim}$ 최대 $11.65\%$까지 골조직에 의한 선량감소가 나타나는 것을 알 수가 있다. 또한, Diode detector로 측정한 심부선량 값은 두부, 경부, 대퇴부, 슬관절, 족관절에서 각각 $95.23{\pm}1.18,\;98.33{\pm}0.6,\;93.5{\pm}1.5,\;87.3{\pm}1.5,\;86.90{\pm}1.16$으로 나타났으며, TLD로 측정한 대퇴부, 슬관절, 족관절에서의 표면선량과 비교했을 때 부위에 따라 최소 $4.53\%{\sim}$ 최대 $12.6\%$ 까지 차이를 보였다. 그리고 골조직에 의한 선량감쇄의 영향이 적은 복부(배꼽)에서는 열형광선량계 및 다이로드측정기로 측정한 값이 각각 $101.58{\pm}0.95,\;104.77{\pm}1.18$로 큰 차이가 없었다. IV 결론 전신방사선조사시 표면선량을 측정하여 심부선량으로 환산한 값은 골조직의 감쇄영향을 고려하지 못하므로 다이로드측정기(Diode detector) 또는 열형광선량계(TLD)로 중심부선량을 직접 측정하는 것이 중요하다. 그러나 중심부의 심부선량을 직접 측정할 수 없을 경우에는 골조직의 감쇄영향을 고려하여 복부배꼽에서의 선량보다 $5\%{\sim}10\%$ 정도의 선량이 초과 조사되도록 보상물질의 두께를 적절하게 조절하는 것이 필요할 것으로 사료된다.

  • PDF

전신계측기를 이용한 원전종사자 방사성오염 위치확인과 내부방사능 측정개선에 관한 연구 (A Study on the Verification and Improvement to Locate and Determine the Radioactive Contamination Using a Whole Body Counter)

  • 김희근;공태영
    • Journal of Radiation Protection and Research
    • /
    • 제34권1호
    • /
    • pp.37-42
    • /
    • 2009
  • 국내 원전에서는 원전종사자의 내부피폭 방사능을 측정하기위해 전신계측기를 이용하고 있다. 이 전신계측기는 Sodium Iodide를 이용한 섬광검출기로서 짧은 시간에 종사자가 보유한 방사성핵종과 방사능을 측정하는 기능을 가지고 있다. 그런데 종사자의 신체표면에 부착된 오염과 내부에 침적된 오염을 구분하지 못하기 때문에 방사선계측 과정에서 종종 오류를 범할 가능성이 있으며, 이 경우 내부피폭선량은 매우 보수적으로 과대평가된다. 이러한 문제점을 개선하고자 종사자의 인체 내부와 외부 표면오염을 구분하고, 보다 체계적으로 오염부위를 확인할 수 있도록 전신계측기와 인체모형 팬텀을 이용한 방사능 계측실험을 수행하였다. 또한 원전에서 발생하는 주요 핵종의 신체내 침적위치를 고려하여 전신계측기의 최적 방사능 측정모드를 결정하는 실험을 수행하였다. 이러한 방사능 측정 실험결과를 근거로 원전종사자의 내부방사능 측정과 선량평가 절차를 개선하였다. 이에따라 보다 정확한 전신계측프로그램의 적용으로 내부피폭선량의 보수적 평가를 방지할 수 있을 것으로 기대된다.

HPLC와 DPPH radical 소거능 측정 방법의 결합에 의한 약용 식물 추출물의 항산화 활성 비교 (Measurement of the Anti-oxidative Properties of Extract from Medicinal Plants Using an On-line HPLC-DPPH Assay)

  • 임도연;표병식;김선민;이경인
    • 생명과학회지
    • /
    • 제27권1호
    • /
    • pp.44-49
    • /
    • 2017
  • 본 연구에서는 일반적으로 분리 및 분석에 가장 빈번히 사용되고 있는 C18 column과 UV 검출기가 장착된 액체크로마토그래피(HPLC)와 항산화 활성 측정에 사용되는 1, 1-diphenyl-2-picryl hydrazyl (DPPH) 라디칼 소거능 측정 방법을 결합한 HPLC-DPPH 동시 측정법의 최적화와 유용성 확인을 약용식물의 추출물을 대상으로 실시하였다. 최종적으로 적용된 HPLC-DPPH 동시 측정법의 유용성은 갈근, 건강, 유근피, 모과, 황기 등 5종 약용식물의 열수추출물과 대조군으로서 ascorbic acid의 라디칼 소거능을 측정하여 확인하였다. HPLC-DPPH 동시 측정에 앞서 추출액 중 고형분 함량을 refractometer를 사용하여 측정함으로써 추출 수율에 따른 활성 차이를 보정할 수 있도록 하였다. 갈근, 모과, 유근피 열수추출물의 라디칼 소거능이 대조군으로 사용된 ascorbic acid와 비교하여 7.77%, 4.71%, 4.19%로서 다른 열수추출물보다 상대적으로 높은 것으로 확인되었다. 이와 같은 측정법은 실제 활성 성분의 분리 및 분석에 있어서 불필요한 시간 및 시약의 낭비를 줄일 수 있는 유용한 수단이 될 수 있을 것으로 판단된다.