• Title/Summary/Keyword: simple tests

Search Result 1,236, Processing Time 0.027 seconds

Interface Capturing for Immiscible Two-phase Fluid Flows by THINC Method (THINC법을 이용한 비혼합 혼상류의 경계면 추적)

  • Lee, Kwang-Ho;Kim, Kyu-Han;Kim, Do-Sam
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.24 no.4
    • /
    • pp.277-286
    • /
    • 2012
  • In the numerical simulation of wave fields using a multi-phase flow model that considers simultaneous flows of materials with different states such as gas, liquid and solid, there is need of an accurate representation of the interface separating the fluids. We adopted an algebraic interface capturing method called tangent of hyperbola for interface-capturing(THINC) method for the capture of the free-surface in computations of multi-phase flow simulations instead of geometrical-type methods such a volume of fluid(VOF) method. The THINC method uses a hyperbolic tangent functions to represent the surface, and compute the numerical flux for the fluid fraction functions. One of the remarkable advantages of THINC method is its easy applicability to incorporate various numerical codes based on Navier-Stokes solver because it does not require the extra geometric reconstruction needed in most of VOF-type methods. Several tests were carried out in order to investigate the advection of interfaces and to verify the applicability of the THINC method to wave fields based on the one-field model for immiscible two-phase flows (TWOPM). The numerical results revealed that the THINC method is able to track the interface between air and water separating the fluids although its algorithm is fairly simple.

Derivation of Probability Plot Correlation Coefficient Test Statistics and Regression Equation for the GEV Model based on L-moments (L-모멘트 법 기반의 GEV 모형을 위한 확률도시 상관계수 검정 통계량 유도 및 회귀식 산정)

  • Ahn, Hyunjun;Jeong, Changsam;Heo, Jun-Haeng
    • Journal of Korean Society of Disaster and Security
    • /
    • v.13 no.1
    • /
    • pp.1-11
    • /
    • 2020
  • One of the important problem in statistical hydrology is to estimate the appropriated probability distribution for a given sample data. For the problem, a goodness-of-fit test is conducted based on the similarity between estimated probability distribution and assumed theoretical probability distribution. Probability plot correlation coefficient test (PPCC) is one of the goodness-of-fit test method. PPCC has high rejection power and its application is simple. In this study, test statistics of PPCC were derived for generalized extreme value distribution (GEV) models based on L-moments and these statistics were suggested by the multiple and nonlinear regression equations for its usability. To review the rejection power of the newly proposed method in this study, Monte Carlo simulation was performed with other goodness-of-fit tests including the existing PPCC test. The results showed that PPCC-A test which is proposed in this study demonstrated better rejection power than other methods, including the existing PPCC test. It is expected that the new method will be helpful to estimate the appropriate probability distribution model.

Analysis on Error Types of Descriptive Evaluations in the Learning of Elementary Mathematics (초등수학 서술형 평가에서 나타나는 오류 유형 분석)

  • Jung, Hyun-Do;Kang, Sin-Po;Kim, Sung-Joon
    • Journal of Elementary Mathematics Education in Korea
    • /
    • v.14 no.3
    • /
    • pp.885-905
    • /
    • 2010
  • This study questions that mathematical evaluations strive to memorize fragmentary knowledge and have an objective test. To solve these problems on mathematical education We did descriptive test. Through the descriptive test, students think and express their ideas freely using mathematical terms. We want to know if that procedure is correct or not, and, if they understand what was being presented. We studied this because We want to analyze where and what kinds of faults they committed, and be able to correct an error so as to establish a correct mathematical concept. The result from this study can be summarized as the following; First, the mistakes students make when solving the descriptive tests can be divided into six things: error of question understanding, error of concept principle, error of data using, error of solving procedure, error of recording procedure, and solving procedure omissions. Second, students had difficulty with the part of the descriptive test that used logical thinking defined by mathematical terms. Third, errors pattern varied as did students' ability level. For high level students, there were a lot of cases of the solving procedure being correct, but simple calculations were not correct. There were also some mistakes due to some students' lack of concept understanding. For middle level students, they couldn't understand questions well, and they analyzed questions arbitrarily. They also have a tendency to solve questions using a wrong strategy with data that only they can understand. Low level students generally had difficulty understanding questions. Even when they understood questions, they couldn't derive the answers because they have a shortage of related knowledge as well as low enthusiasm on the subject.

  • PDF

Clinical Laboratory Aspect of Carbapenem-Resistant Enterobacteriaceae (카바페넴내성장내세균속균종의 임상검사 측면)

  • Park, Chang-Eun
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.52 no.1
    • /
    • pp.18-27
    • /
    • 2020
  • The correct distinction of carbapenem-resistant Enterobacteriaceae (CRE) and ccarbapenemase producing Enterobacteriaceae (CPE) and the rapid detection of CPE are important for instituting the correct treatment and management of clinical infections. Screening protocols are mainly based on cultures of rectal swab specimens on selective media followed by phenotypic tests to confirm a carbapenem-hydrolyzing activity, the rapid carbapenem inactivation method, lateral flow immunoassay, the matrix-assisted laser desorption ionization-time-of-flight test and molecular methods. The CPE is accurate for detection, and is essential for the clinical treatment and prevention of infections. A variety of phenotypic methods and gene-based methods are available for the rapid detection of carbapenemases, and these are expected to be routinely used in clinical microbiology laboratories. Therefore, to control the spread of carbapenemase, many laboratories around the world will need to use reliable, fast, high efficiency, simple and low cost methods. Optimal effects in patient applications would require rapid testing of CRE to provide reproducible support for antimicrobial management interventions or the treatment by various types of clinicians. For the optimal test method, it is necessary to combine complementary test methods to discriminate between various resistant bacterial species and to discover the genetic diversity of various types of carbapenemase for arriving at the best infection control strategy.

Production and Characterization of Monoclonal Antibodies Specific to PAT Protein Expressed in Genetically Modified Herbicide-Resistance Maize (제초제 내성 유전자 변형 옥수수 중 PAT단백질에 특이한 단크론성 항체의 생산과 특성 확인)

  • Kim, Sol-A;Lee, Jeong-Eun;Shim, Won-Bo;Kang, Sung-Jo;Chung, Duck-Hwa
    • Journal of Food Hygiene and Safety
    • /
    • v.33 no.3
    • /
    • pp.193-199
    • /
    • 2018
  • In this study, PAT protein of genetically modified maize was prepared from the recombinant E. coli strain BL21 (DE3), and mice were immunized with the recombinant PAT protein. After cell fusion and cloning, two hybridoma cells (PATmAb-7 and PATmAb-12) were chosen since the monoclonal antibodies (Mabs) produced by them were confirmed to be specific to PAT protein in the indirect enzyme-linked immunsorbent assay (ELISA) and western blot tests. There were no cross-reactions of either Mabs to other GM proteins or to the extracts of non-GM maize. The ELISA based on the PATmAb-7 can sensitively detect 0.3 ng/g PAT protein in corn. These results indicate that the developed Mabs can be used as bio-receptors in the development of immunosensors and biosensors for the rapid and simple detection of GM corn adulterated in foods.

Bioconversion Strategy in Conversion of Lignocellulosic Biomass upon Various Pretreatment Methods using Sulfuric Acid and Aqueous Ammonia (황산과 암모니아를 이용한 목질계 바이오매스의 전처리 공정에 따른 당화 및 발효공정 전략)

  • Cayetano, Roent Dune;Kim, Tae Hyun;Um, Byung-Hwan
    • Korean Chemical Engineering Research
    • /
    • v.52 no.1
    • /
    • pp.45-51
    • /
    • 2014
  • This is to study the effects of various pretreatment methods of agricultural residue, corn stover, and to compare the feature and pros and cons of each method including dilute sulfuric acid (DSA), soaking in aqueous ammonia (SAA), and ammonia recycle percolation (ARP). In order to convert corn stover to ethanol, various pretreatments followed by simultaneous saccharification and co-fermentation (SSCF) were tested and evaluated in terms of ethanol yield. With 3%, w/w of glucan loading using ARP-, DSA-, and SAA-treated solids, SSCFs using recombinant E. coli strain (ATCC$^{(R)}$ 55124) with commercial enzymes (15 FPU of Spezyme CP/g-glucan and 30 CBU/g-glucan enzyme loading) were tested. In the SSCF tests, 87, 90, and 78% of theoretical maximum ethanol yield were observed using ARP-, DSA-, and SAA-treated solids, respectively, which were 69, 58, and 74% on the basis of total carbohydrates (glucan + xylan) in the untreated corn stover. Ethanol yield of SAA-treated solid was higher than those of ARP- and DSA-treated solids. In addition, SSCF test using treated solids plus pretreated hydrolysate indicated that the DSA-treated hydrolysate showed the strongest inhibition effect on the KO11 strain, whereas the ARP-treated hydrolysate was found to have the second strongest inhibition effect. Bioconversion scheme using SAA pretreatment and SSCF can make the downstream process simple, which is suggested to produce ethanol economically because utilization of hemicellulose in the hydrolysate is not necessary.

First Detection of $bla_{IMP-1}$ in Clinical Isolate Multiresistant Acinetobacter baumannii from Korea

  • Jeong Seok-Hoon;Bae Il-Kwon;Sohn Seung-Ghyu;Park Kwang-Ok;An Young-Jun;Sung Kwang-Hoon;Jang Seon-Ju;Heo Myong-Jin;Yang Ki-Suk;Lee Sang-Hee
    • Journal of Microbiology and Biotechnology
    • /
    • v.16 no.9
    • /
    • pp.1377-1383
    • /
    • 2006
  • Among 46 Acinetobacter baumannii isolates collected in 2004, two imipenem-resistant isolates were obtained from clinical specimens taken from patients hospitalized in Busan, Republic of Korea. Two carbapenemase-producing isolates were further investigated to determine the mechanism of resistance. These isolates were analyzed by antibiotic susceptibility testing, microbiological tests of carbapenemase activity, determination of pI, transconjugation test, enterobacterial repetitive consensus (ERIC)-PCR, and DNA sequencing. Two cases of infection by A. baumannii producing the IMP-1 ${\beta}$-lactamase were detected. The isolates were characterized by a modified cloverleaf synergy test and EDTA-disk synergy test. Isoelectric focusing of crude bacterial extracts revealed nitrocefin-positive bands with a pI value of 9.0. PCR amplification and characterization of the amplicons by direct sequencing indicated that the isolates carried a $bla_{IMP-l}$ determinant. The isolates were characterized by a multidrug resistance phenotype, including penicillins, extended-spectrum cephalosporins, carbapenems, and aminoglycosides. These results indicate that the observed imipenem resistance of two Korean A. baumannii isolates was due to the spread of an IMP-1-producing clone. Our microbiological test of carbapenemase activity is simple to screen class B metallo-${\beta}$-lactamase-producing clinical isolates to determine their clinical impact and to prevent further spread. This study shows that the $bla_{IMP-l}$ resistance determinant, which is emerging in Korea, may become an emerging therapeutic problem, since clinicians are advised not to use extended-spectrum cephalosporins, imipenem, and aminoglycosides. This observation emphasizes the importance of having effective control measures in Asian hospitals, such as early detection of colonized patients, isolation procedures, and a judicious use of antibiotics.

A Content Analysis on Learning Experience of K-MOOC(Korea-Massive Open Online Course) : Focused on Korean University Students (한국 대학생의 K-MOOC 학습 경험에 대한 내용 분석)

  • Park, Tae-Jung;Rah, Ilju
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.12
    • /
    • pp.446-457
    • /
    • 2016
  • The purpose of the study was to understand the various aspects of learning experiences of Korean university students on K-MOOC. Analyses on the major motivation of the enrollment in a certain MOOC class, the actual learning experiences in the class and the perception of the achievement of the class were the three main foci of the current study. The study employed inductive content analysis as a major analysis tool. Reflective journals from 94 students who enrolled in K-MOOC classes were collected and analyzed at the end of the semester. The result of this study indicated that most of students selected the specific K-MOOC classes based on their general interests on the topics the class offered. Other factors such as intellectual curiosity, practical reasons for their study or work and popularity were also influential on the selection of MOOC classes. Watching videos, taking quizzes and taking tests were the three major sources of the students' satisfaction. Most students felt that K-MOOC is technically satisfactory. However, some students reported on simple errors and absence of advanced functions in the platform. Students perceived positively on their academic achievements of obtaining knowledge(remembering and understanding), attitudes (receiving), and skills through K-MOOC. This study ultimately showed a new awareness of learning experiences around K-MOOC from the perspective of the students. Future research is needed to understand the relationships between the students' learning experience and the students' performance in MOOC classes.

Development of real-time PCR for rapid detection of Mycobacterium bovis DNA in cattle lymph nodes and differentiation of M. bovis and M. tuberculosis (소 림프절에서 Mycobacterium bovis DNA의 신속 검출과 M. bovis와 M. tuberculosis 감별을 위한 real-time PCR 개발)

  • Koh, Ba-Ra-Da;Jang, Young-Boo;Ku, Bok-Kyung;Cho, Ho-Seong;Bae, Seong-Yeol;Na, Ho-Myung;Park, Seong-Do;Kim, Yong-Hwan;Mun, Yong-Un
    • Korean Journal of Veterinary Service
    • /
    • v.34 no.4
    • /
    • pp.321-331
    • /
    • 2011
  • Mycobacterium bovis, a member of the M. tuberculosis complex (MTC), is the causative agent of bovine tuberculosis. Detection of M. bovis and M. tuberculosis using conventional culture- and biochemical-based assays is time-consuming. Therefore, a simple and sensitive molecular assay for rapid detection would be of great help in specific situations such as faster diagnosis of bovine tuberculosis (bTB) infection in the abattoirs. We developed a novel multiplex real-time PCR assay which was applied directly to biological samples with evidence of bTB and it was allowed to differentiate between M. bovis and M. tuberculosis. The primers and TaqMan probes were designed to target the IS1081 gene, the multi-copy insertion element in the MTC and the 12.7-kb fragment which presents in M. tuberculosis, not in the M. bovis genome. The assay was optimized and validated by testing 10 species of mycobacteria including M. bovis and M. tuberculosis, and 10 other bacterial species such as Escherichia coli, and cattle lymph nodes (n=113). The tests identified 96.4% (27/28) as M. bovis from the MTC-positive bTB samples using conventional PCR for specific insertion elements IS1081. And MTC-negative bTB samples (n=85) were tested using conventional PCR and the real-time PCR. When comparative analyses were conducted on all bovine samples, using conventional PCR as the gold standard, the relative accuracy of real-time PCR was 99.1%, the relative specificity was 100%, and the agreement quotient (kappa) was 0.976. The detection limits of the real-time PCR assays for M. bovis and M. tuberculosis genomic DNA were 10 fg and 0.1 pg per PCR reaction, respectively. Consequently, this multiplex real-time PCR assay is a useful diagnotic tool for the identification of MTC and differentiation of M. bovis and M. tuberculosis, as well as the epidemiologic surveillance of animals slaughtered in abattoir.

Technique for the Measurement of Crack Widths at Notched / Unnotched Regions and Local Strains (콘크리트의 노치 및 비노치 구역에서의 균열폭 및 국부 변형률 정밀 측정기법)

  • Choi, Sok-Hwan;Lim, Bub-Mook;Oh, Chang-Kook;Joh, Chang-Bin
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.2
    • /
    • pp.205-214
    • /
    • 2012
  • Crack widths play an important role in the serviceability limit state. When crack widths are controlled sufficiently, the reinforcement corrosion can be reduced using only existing concrete cover thickness due to low permeability in the region of finely distributed hair-cracks. Thus, the knowledge about the tensile crack opening is essential in designing more durable concrete structures. Therefore, numerous researches related to the topic have been performed. Nevertheless accurate measurement of a crack width is not a simple task due to several reasons such as unknown potential crack formation location and crack opening damaging strain gages. In order to overcome these difficulties and measure precise crack widths, a displacement measurement system was developed using digital image correlation. Accuracy calibration tests gave an average measurement error of 0.069 pixels and a standard deviation of 0.050 pixels. Direct tensile test was performed using ultra high performance concrete specimens. Crack widths at both notched and unnotched locations were measured and compared with clip-in gages at various loading steps to obtain crack opening profile. Tensile deformation characteristics of concrete were well visualized using displacement vectors and full-field displacement contour maps. The proposed technique made it possible to measure crack widths at arbitrary locations, which is difficult with conventional gages such as clip-in gages or displacement transducers.