• Title/Summary/Keyword: similar material

Search Result 3,185, Processing Time 0.028 seconds

Development predictive equations for tensile properties of S235JR structural steels after fire

  • Ozer Zeybek;Veysel Polat;Yasin Onuralp Ozkilic
    • Steel and Composite Structures
    • /
    • v.53 no.2
    • /
    • pp.243-252
    • /
    • 2024
  • Conventional carbon mild steel is a type of steel known for its low carbon content and generally used in the construction industry. Its easily formable and weldable properties make this steel a widely preferred material for buildings, bridges and various construction projects. Other advantages of these steels are their low cost and good mechanical properties. However, high temperatures have an impact on the microstructure and mechanical characteristics of these materials. When high temperatures are present during a fire, steels show significant microstructural changes. Elevated temperatures often decrease the mechanical characteristics of steels. For this purpose, evaluating the post-fire behavior of conventional structural mild steel is an important issue in terms of safety. A combined experimental and parametric study was conducted to estimate fire damage to steel buildings, which is an important issue in the construction field. Tensile test coupons were cut from conventional structural S235JR mild steel sheets with thicknesses ranging from 6 mm to 12 mm. These samples were exposed to temperatures as high as 1200 ℃. After heat treatment, the specimens were allowed to naturally cool to ambient temperature using air cooling before being tested. A tensile test was performed on these coupons to evaluate their mechanical properties after fire, such as their elastic modulus, yield strength, and ultimate tensile strength. The mechanical behavior of conventional S235JR structural steel changed significantly when the heating temperature reached 600℃. The thickness of the steel had a negligible effect on yield strength loss, with the highest measured loss being 50% for 8 mm thickness at 1200℃. For thinner sections (6 mm), yield strength decreased by up to 40%, while thicker samples (12 mm) showed similar reductions. Ultimate tensile strength also showed minimal changes up to 600℃, but beyond this point, a notable decline occurred, with approximately 30% strength loss at 1200℃. The modulus of elasticity remained almost constant up to 800℃, but at 1200℃, the loss reached around 20% for thicker sections (10 mm and 12 mm) and up to 35% for thinner sections (6 mm and 8 mm). Overall, high temperatures led to significant deterioration in both yield and ultimate strength, with a general loss of load-bearing capacity above 600℃. A new equation was formulated from experimental results to predict changes in the mechanical properties of S235JR steels. This equation offers a precise evaluation of buildings made from conventional structural S235JR mild steel after fire exposure. Furthermore, the empirical equation is applicable to low-strength steels with yield strengths ranging from 235 MPa to 420 MPa.

Radiation Protection and Recovery Effects of Red Ginseng, Saururus chinensis (Lour.) Baill. and Rubus coreanus Miq. Mixed Extracts in SD Rat irradiated to Gamma-ray 6 Gy (감마선 6 Gy에 조사된 SD Rat에서 홍삼, 삼백초, 복분자 혼합 추출물의 방사선 방호 및 회복 효과)

  • Seong-Ock Jin;Jae-Hyeong Park;Sung-Hyun Joo;Jae-Gyeong Choi;Byung-In Min
    • Journal of radiological science and technology
    • /
    • v.47 no.5
    • /
    • pp.375-383
    • /
    • 2024
  • The purpose of this study is to confirm the radiation protection and recovery effects of natural mixed radiation protection agents. Red Ginseng, Saururus chinensis (Lour.) Baill. and Rubus coreanus Miq. mixed extract was orally administered to male SD rats and changes were observed in the blood, small intestine and prostate. The experimental group was organized into a general control group (NC Group), mixed extract administration group (RSR Group), 6 Gy irradiation group (IR Group), and irradiation group after administration of the mixed extract (RSR+IR Group). Among them, the RSR Group and RSR+IR Group were orally administered 2 cc (36.6 mg/day/250 g) of the extract once for two weeks at the same time, and at the end of administration, the IR Group and RSR+IR Group were irradiated with 6 Gy whole body radiation. Looking at hematological changes, the RSR + IR Group showed higher recovery and higher levels of white blood cells and platelets than the IR Group. And SOD levels showed high activity in the group administered the extract. Looking at the small intestine, compared to the IR Group, the RSR+IR Group shows better protection and recovery of small intestine villi length. Likewise, in the prostate, there is less cell damage in the RSR+IR Group, and on the 21st day, the prostate spacing is constant, showing a similar pattern to the NC Group. It is believed that the mixed extract used in the study has radiation protection and recovery effects in male SD rats and will be helpful in the study of mixed radiation protection agents.

THE BOND CHARACTERISTICS OF PORCELAIN FUSED BY TITANIUM SURFACE MODIFICATION (타이타늄의 표면개질에 따른 도재 결합 특성)

  • Choi, Taek-Huw;Park, Sang-Won;Vang, Mong-Sook;Yang, Hong-So;Park, Ha-Ok;Lim, Hyun-Pil;Oh, Gye-Jeong;Kim, Hyun-Seung;Lee, Kwang-Min;Lee, Kyung-Ku
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.2
    • /
    • pp.169-181
    • /
    • 2007
  • Statement of problem: Titanium is well known as a proper metal for the dental restorations, because it has an excellent biocompatibility, resistance to corrosion, and mechanical property. However, adhesion between titanium and dental porcelains is related to the diffusion of oxygen to the reaction layers formed on cast-titanium surfaces during porcelain firing and those oxidized layers make the adhesion difficult to be formed. Many studies using mechanical, chemical and physical methods to enhance the titanium-ceramic adhesion have been actively performed. Purpose: This study meant to comparatively analyse the adhesion characteristics depending on different titanium surface coatings after coating the casts and wrought titanium surfaces with Au and TiN. Material and method: In this study, the titanium specimens (CP-Ti, Grade 2, Kobe still Co. Japan) were categorized into cast and wrought titanium. The wrought titanium was cast by using the MgO-based investment(Selevest CB, Selec). The cast and wrought titanium were treated with Au coating($ParaOne^{(R)}$., Gold Ion Sputter, Model PS-1200) and TiN coating(ATEC system, Korea) and the ultra low fusing dental porcelain was fused and fired onto the samples. Biaxial flection test was done on the fired samples and the porcelain was separated. The adhesion characteristics of porcelain and titanium after firing and the specimen surfaces before and after the porcelain fracture test were observed with SEM. The atomic percent of Si on all sample surfaces was comparatively analysed by EDS. In addition, the constituents of specimen surface layers after the porcelain fracture and the formed compound were evaluated by X-ray diffraction diagnosis. Result: The results of this study were obtained as follows : 1. The surface characteristics of cast and wrought titanium after surface treatment(Au, TiN, $Al_2O_3$ sandblasting) were similar and each cast and wrought titanium showed similar bonding characteristics. 2. Before and after the biaxial flection test, the highest atomic weight change of Si component was found in $Al_2O_3$ sandblasted wrought titanium(28.6at.% $\rightarrow$ 8.3at.%). On the other hand, the least change was seen in Au-Pd-In alloy(24.5at.% $\rightarrow$ 9.1at.%). 3. Much amount of Si components was uniformly distributed in Au and TiN coated titanium, but less amount of Si's was unevenly dispersed on Al2O3 sandblasting surfaces. 4. In X-ray diffraction diagnosis after porcelain debonding, we could see $Au_2Ti$ compound and TiN coating layers on Au and TiN coated surfaces and $TiO_2$, typical oxide of titanium, on all titanium surfaces. 5. Debonding of porcelain on cast and wrought titanium surface after the biaxial flection is considered as a result of adhesion deterioration between coating layers and titanium surfaces. We found that there are both adhesive failure and cohesive failure at the same time. Conclusion: These results showed that the titanium-ceramic adhesion could be improved by coating cast and wrought titanium surfaces with Au and TiN when making porcelain fused to metal crowns. In order to use porcelain fused to titanium clinically, it is considered that coating technique to enhance the bonding strength between coating kKlayers and titanium surfaces should be developed first.

Analysis of Occlusal Contacts Using Add-picture Method (Add-picture 방법을 이용한 교합접촉점 분석)

  • Park, Ko-Woon;Cho, Lee-Ra;Kim, Dae-Gon;Park, Chan-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.1
    • /
    • pp.45-58
    • /
    • 2013
  • The purpose of this study was to analyze the area of occlusal contact points using visual method. One subject was selected who had Angle Class I, normal dentition, without dental caries, periodontal disease and temporomandibular disorders. Forty times PVS impressions were taken and 10 pairs casts were fabricated using dental super hard stone. After mounting the casts with customized loading apparatus, 78.9kg/f force was loaded as a maximum biting force. In T-Scan method, occlusal contact points measurement was repeated twice. Then, using Photoshop program (Adobe photoshop CS3, Adobe. San Jose, USA), the pixels which indicated occlusal contact points by color was recognized, and the distribution of recognized pixels were calculated to area. In Add picture method, polyether bite material applied to the occlusal surface of the casts. Then, the image of the translucent areas was recorded and classified $0{\sim}10{\mu}m$, $0{\sim}30{\mu}m$, $0{\sim}60{\mu}m$ area by the amount of transmitted light. To acquire occlusal surface, the numbers of pixels from the photograph of the contact area indicated cast converted to $mm^2$. The mean occlusal contact area by two methods was statistically analyzed (paired t-test). Part of the red and pink area in T-Scan image were almost equivalent to the $0{\sim}10{\mu}m$, $0{\sim}30{\mu}m$, $0{\sim}60{\mu}m$ area in Add picture image. The distribution of occlusal contact points were similar, but the average area of occlusal contact points was wider in T-scan image (P<.05). Pink and red area in T-scan image was wider than $0{\sim}10{\mu}m$, $0{\sim}30{\mu}m$ area in Add picture image (P<.05), but similar to $0{\sim}60{\mu}m$area in Add picture image (P>.05). Occlusal contact points in T-scan image did not indicate real occlusal contact points. Occlusal contact areas in T-scan method were enlarged results comparing with those in Add picture method.

Comparison of Mitral Valve Repair between a Minimally Invasive Approach and a Conventional Sternotomy Approach (승모판 성형술에 있어 최초 침습적 수술방식과 고전적 정중 흉골 절개술을 통한 접근방식의 비교)

  • Cho, Won-Chul;Je, Hyoung-Gon;Kim, Jeong-Won;Lee, Jae-Won
    • Journal of Chest Surgery
    • /
    • v.40 no.12
    • /
    • pp.825-830
    • /
    • 2007
  • Background: Minimally invasive cardiac surgery appears to offer certain advantages such as earlier postoperative recovery and a greater cosmetic effect than that achieved through conventional sternotomy. However, this approach has not yet been widely adopted in Korea to replace complex open heart surgery such as mitral valve reconstruction. This study compared the results of robot assisted minimally invasive mitral valve repair with those results of conventional sternotomy. Material and Method: From December 1993 to December 2005, 520 consecutive patients underwent mitral valve reconstruction for mitral regurgitation in our institution. These patients were subdivided according to those whose surgery used the conventional sternotomy approach (Group S, n=432) and those who underwent minimally invasive right anterior thoracotomy (Group M, n=88); we then compared the clinical results of both groups. When we performed minimally invasive right thoracotomy, we used a robot (AESOP 3000) and made an incision less than 5 cm. Result: Our study patients in both groups were similar for their age, gender and preoperative ejection fraction. There were two hospital mortalities in group S. but there was no mortality in the group M patients. Significant reductions in the ICU stay and the postoperative hospital stay were observed in the group M patients compared with the group S patients. However, both the bypass time and the aortic cross-clamp time were significantly longer in the group M patients. In spite of the confined incision in the group M patients, there were no limitations on the mitral valve repair techniques. There was a similar frequency of postoperative significant residual mitral regurgitation in both groups. Conclusion: In this study, the minimally invasive mitral valve repair showed comparable early results with the conventional sternotomy patients. We will now need long-term follow-up of these patients who underwent minimally invasive mitral valve repair, but we anticipate that based on the results of this study, we will begin to routinely perform minimally invasive cardiac surgery as out primary approach for mitral valve reconstruction.

DEVELOPMENT OF BIOCOMPATIBLE DRESSING MATERIAL MADE OF COLLAGEN AND AMNIOTIC MEMBRANE AND WOUND HEALING EXPERIMENT IN RAT (양막과 콜라겐을 이용한 생체 적합 드레싱 소재 개발 및 백서 창상치유 실험)

  • Ahn, Kang-Min;Lee, Ji-Ho;Lee, Ui-Lyong;Lee, Jong-Ho;Lee, Jong-Won;Kim, Sung-Po;Yang, Eun-Kyung;Kim, Ki-Ho
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.32 no.3
    • /
    • pp.189-199
    • /
    • 2006
  • Purpose of study: Partial thickness skin graft is the golden standard regimen for full-thickness skin defect caused by burn or trauma. However, in case of extensive burns of more than 50% of total body surface area, the donor site is not sufficient to cover all defects. As a second choice, allograft, xenograft and synthetic materials have been used to treat skin defect. Among them the amniotic membrane(AM) was used as a biological dressing for centuries because of its potential for wound healing. In this study, quantification of EGF in AM and effect of AM-collagen complex on full thickness skin defects was examined. Materials & Methods: The concentration of EGF in fresh, deep frozen and freeze-dried AM was evaluated by ELISA. EGF-R immunostaining was performed in freeze-dried AM. SD rats weighing 250${\sim}$300g was used for wound healing experiment. Three full thickness skin defects(28mm diameter) were made on dorsal surface of SD rat. The control group was covered by Vaselin gauze and AM-collagen complex and $Terudermis^{(R)}$. was grafted in two other defects. Healing area, Cinamon's score were evaluated before biopsy. Grafted sites were retrieved at 3 days, 1 week, 2 weeks and 4 weeks after operation. H & E and Factor VIII immunohistochemical stain was performed to evaluate the microscopic adhesion and structural integrity and microvessel formation. Results: 1. EGF concentration of fresh, deep frozen and freeze-dried AM showed similar level and EGF-R was stained in epithelial layer of freeze-dried AM. 2. At 4 weeks after grafting, the healing area of AM-collagen and Terudermis group was 99.29${\pm}$0.71% and 99.19${\pm}$0.77 of original size. However, that of control group was 24.88${\pm}$2.90. 3. The Cinamon's score of AM-Collagen and $Terudermis^{(R)}$. group at 4 weeks was 15.6${\pm}$1.26 and 14.6${\pm}$3.13 and that of control group was 3.7${\pm}$0.95. Significant difference was observed among control and experimental groups(p<0.05). 4. Histologic examination revealed that AM protected leukocyte infiltration and epithelial migration was nearly completed at 4 weeks. $Terudermis^{(R)}$. group showed mild neutrophil infiltration until 2 weeks and completion of epithelization at 4 weeks. Control group showed massive leukocyte infiltration until 4 weeks. 5. Microvessels were increased sharply at 1 week and control group at 1 and 4 week showed significant differences with $Terudermis^{(R)}$. group of same interval(p<0.05) but no differences were found with AM group(p<0.05). Conclusion: EGF and EGF-R were well preserved in freeze-dried AM. AM attached to collagen acted as excellent biologic dressing which had similar effect with $Terudermis^{(R)}$. AM showed anti-inflammatory action and healing was completed at 4 weeks after full-thickness skin defect.

Risk factors of Pneumonectomy in Non-Small Cell Lung Cancer (비소세포폐암에시 전폐절제술의 위험 인자)

  • Hwang Eun-Gu;Baek Heejong;Lee Hae-Won;Park Jong-Ho;Zo Jae-Ill
    • Journal of Chest Surgery
    • /
    • v.38 no.9 s.254
    • /
    • pp.616-621
    • /
    • 2005
  • Background: In the resection of lung cancer, pneumonectomy occupied $20 {\~}35\%$ of all resections, and significantly high operative mortality is reported in right pneumonectomy ($10{\~}25\%$). The aim of this study is to identify the characteristics of morbidity, operative mortality and factors affecting operative mortality after pneumonectomy. Material and Method: This study recruited the database which performed pneumonectomy for lung cancer in Korea Cancer Center Hospital from Aug 1987 to Apr 2002. Result: Total of 386 pneumonectomies were peformed in that period. Sidedness were left in 238, right in 148; and the procedures were standard resection in 207, and extended resection in 179. Morbidity occurred in 115 cases ($29.8\%$, 115/386). Mortality occurred in 12 cases ($3.1\%$, 12 in 386). This mortality rate was similar to that of lobectomy ($2.1\%$, 13 in 613) during the same period. Morbidity consisted of 42 hoarseness, 17 (9) pneumonia and ARDS, 8 empyema, 5 (1) broncho-pleural fistula, 5 reoperation for bleeding, 5 (1) arrhythmia, 1 (1) pulmonary edema, and 25 others (The number in the parenthesis is the number of mortality case for that morbidity). Several factors affecting the operative mortality were evaluated. At first, extended procedure ($3.3\%$, 6 in 179) affected the operative mortality similar to the standard procedure ($2.9\%$, 6 in 207)(p=0.812). Second, the rate of operative mortality in an elderly group over 60 years ($5.5\%$, 10 in 182) was significantly higher than the younger group under 60 years ($1\%$, 2 in 204)(p=0.016). Third, sidedness of resection affects to operative mortality. Right pneumonectomy ($6.8\%$, 10 in 148) showed higher operative mortality than that of left pneumonectomy ($0.8\%$, 2 in 238)(p=0.002). The group over 60 years showed higher incidence of respiratory morbidity ($11.0\%$, 20 in 182) than that of the group under 60 years ($3.4\%$, 7 in 204)(p=0.005). Right pneumonectomy also showed significantly higher incidence ($11.5\%$, 17 in 148) than that of left pneumonectomy ($4.2\%$, 10 in 238)(p=0.008). Conclusion: Age and sidedness of pneumonectomy were the risk factors of operative mortality and respiratory complications, Therefore, careful selection of patients and more attention perioperatively were demanded in right pneumonectomy. However, because the operative mortality is acceptable, pneumonectomy could be done safely if the pneumonectomy is necessary for curative resection of lung cancer.

Dose Evaluation of Dental Artifacts Using MVCT in Head and Neck (두경부암 환자의 MVCT를 이용한 치아 인공물 보정에 따른 선량평가)

  • Shin, Chung Hun;Yun, In Ha;Jeon, Su Dong;Kim, Jeong Mi;Kim, Ho Jin;Back, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.2
    • /
    • pp.25-31
    • /
    • 2019
  • Purpose: Metals induce metal artifact during CT-image for therapy planning, and it occurs images distortion, which affects the volumetric measurement and radiation calculation. In the case of using megavoltage computed tomography(MVCT), the volume of metals can be measured as similar to true volume due to minimal metal artifact outcome. In this study, radiation assessment was conducted by comparing teeth volume from images of kVCT and MVCT of head and neck cancer patients, then assigning to kVCT image to calculate radiation after obtaining the similar volume of true teeth volume from MVCT. Also, formal IR image was able to verify the accuracy of radiation calculation. Material and method: 5 head and neck cancer patients who had intensity-modulated radiation therapy from Radixact® Series were of the subject in this study. Calculations of radiation when constraining true teeth volume out of kVCT image(A-CT) and when designated specific HU after teeth assigned using MVCT image were compared with formal IR image. Treatment planning was devised at the same constraints and mean dose was measured at the radiation assess points. The points were anterior of the teeth, between PTV and the teeth, the interior of PTV near the teeth, and the teeth where 5cm distance from PTV. Result: A difference of metals volume from kVCT and MVCT image was mean 3.49±2.61cc, maximum 7.43cc. PTV was limited to where the internal teeth were fully contained. The results of PTV dose evaluation showed that the average CI value of the kVCT treatment planning without the artifact correction was 0.86, and the average CI value of the kVCT with the artifact correction using MVCT image was 0.9. Conclusion: When the Treatment Planning was made without correction of metal artifacts, the dose of PTV was underestimated, indicating that dose uncertainty occurred. When the computerized treatment plan was made without correction of metal artifacts, the dose of PTV was underestimated, indicating that dose uncertainty occurred.

The Sympathetic Skin Responses after Thoracic Sympathicotomy for Patients with Palmar Hyperhidrosis (수장부 다한증환자의 흉부 교감신경절단술후 교감신경 피부반응)

  • 김오곤;홍종면;이석재;홍장수;이광래;김상규
    • Journal of Chest Surgery
    • /
    • v.32 no.6
    • /
    • pp.579-583
    • /
    • 1999
  • Background: Thoracic sympathicotomy has been used safely and successfully to manage palmar hyperhidrosis. The preoperative and postoperative recording of Sympathetic Skin Responses(SSR) was performed for objective evaluation and follow-up of thoracic sympathicotomy in hyperhidrosis patients, and also for ascertaining the clinical usefullness of SSR. Material and Method: The recording of SSR was performed on 15 patients suffering from palmar hyperhidrosis with Medelec Sapphire Plus electromyogragh before and after thoracic sympathicotomy. Eletrical stimuli on the right median nerve was made in patients in supine position and results were recorded on right and left palms with soles at the same time by 4 channels. Skin temperatures were also monitored simultaneously. T2,3 sympathicotomy was performed with VATS in every patients. SSR was done in 2 patients one month later. Result: Clinically, all patients had symptomatic improvement with satisfaction. Postoperative complication was small amount of residual pneumothorax in 5 patients but it was absorbed sponteneously. There was no recurrence during follow-up period and ten patients(66%) complained compensatory hyperhidrosis. After operation, SSR change was shown in every 15 patients. Abolition of SSR on both palms was achieved in 12 patients(80%) and on both soles in 6 patients. In the other 3 patients, the latencies were significantly delayed and the amplitudes were significantly reduced at both palms and soles. In two patients who were examined at one month later after operation, similar results with postoperative SSRs were shown. The skin temperature on preoperative both palm and sole were lower than normal temperature, and those on postoperative both palm and sole were increased. Those had statistical significance(p<0.05), and the temperature on the palm was increased higher that than on the sole. Conclusion: After thoracic sympathicotomy was performed on palmar hyperhidrosis patients, an increment of skin temperatures and SSR changes were achieved at both palms and soles of all patients. Palmar SSRs were completely abolished in 12 patients(80%), and similar results of postoperative SSRs were achieved. The recording of SSR may be useful to easily and objectively assess the completeness of sympathicotomy and the follow-up of recurrence in hyperhidrosis patients.

  • PDF

Microleakage of endodontically treated teeth restored with three different esthetic post and cores (심미적 포스트 코어의 종류에 따른 미세누출에 관한 연구)

  • Park, Ji-Geun;Park, Ji-Man;Park, Eun-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.1
    • /
    • pp.53-60
    • /
    • 2009
  • Statement of problem: At present, as the esthetic demands are on the increase, there are many ongoing studies for tooth-colored post and cores. Most of them are about fiber post and prefabricated zirconia post, but few about one-piece milled zirconia post and core using CAD/CAM (computer-aided design/computer-aided manufacturing) technique. Purpose: The objective of this study was to compare microleakage of endodontically treated teeth restored with three different tooth-colored post and cores. Material and methods: Extracted 27 human maxillary incisors were cut at the cementoenamel junction, and the teeth were endodontically treated. Teeth were divided into 3 groups (n=9); restored with fiber post and resin core, prefabricated zirconia post and heat-pressed ceramic core, and CAD/CAM milled zirconia post and core. After the preparation of post space, each post was cemented with dual-polymerized resin cement (Variolink II). Teeth were thermocycled for 1000 cycles between $5-55^{\circ}C$ and dyed in 2% methylene blue at $37^{\circ}C$ for 24 hours. Teeth were sectioned (bucco-lingual), kept the record of microleakage and then image-analyzed using a microscope and computer program. The data were analyzed by one-way ANOVA and Scheffe's multiple range test (${\alpha}=0.05$). Results: All groups showed microleakage and there were no significant differences among the groups (P>.05). Prefabricated zirconia post and heat-pressed ceramic core showed more leakage in dye penetration at the post-tooth margin, but there was little microleakage at the end of the post. Fiber post and resin core group and CAD/CAM milled zirconia post and core group indicated similar microleakage score in each stage. Conclusion: Prefabricated zirconia post and heat-pressed ceramic core group demonstrated better resistance to leakage, and fiber post and resin core group and CAD/CAM milled zirconia post and core group showed the similar patterns. The ANOVA test didn't indicate significant differences in microleakage among test groups. (P>.05)