• Title/Summary/Keyword: shunt

Search Result 1,335, Processing Time 0.025 seconds

Management of Posthemorrhagic Hydrocephalus in an Extremely Low Birth Weight Infant with an Ommaya reservoir: A Case Report (Ommaya reservoir로 관리한 초극소저출생 체중아의 출혈 후 수두증 1례)

  • Cho, Hye-Jung;Son, Dong-Woo;Shim, So-Yeon;Kim, Eun-Young;Kim, Seung-Ki;Kim, Han-Suk;Jeon, In-Sang
    • Neonatal Medicine
    • /
    • v.16 no.2
    • /
    • pp.234-238
    • /
    • 2009
  • Posthemorrhagic hydrocephalus is a major problem in premature infants. We describe our experience with a neonate that was an extremely low birth weight infant with posthemorrhagic hydrocephalus, who was treated by repeated ventricular drainage through an Ommaya reservoir for more than two months until the placement of a ventriculoperitoneal shunt was possible. The Ommaya reservoir served as a bridge to definitive treatment. The patient required sodium supplements due to excessive salt loss from the repeated ventricular drainage procedures. Regular measurement of serum electrolytes in any infant requiring serial ventricular drainage is recommended.

Design of MMIC SPST Switches Using GaAs MESFETs (GaAs MESFET을 이용한 MMIC SPST 스위치 설계)

  • 이명규;윤경식;형창희;김해천;박철순
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.4C
    • /
    • pp.371-379
    • /
    • 2002
  • In this paper, the MMIC SPST switches operating from DC to 3GHz were designed and implemented. Prior to the design of switches, the small and large-signal switch models were needed to predict switch performance accurately. The newly proposed small-signal switch model parameters were extracted from measured S-parameters using optimization technique with estimated initial values and boundary limits. In the extraction of large-signal switch model parameters, the current source was modeled by fitting empirical equations to measured DC data and the charge model was derived from extracted channel capacitances from measured S-parameters varying the drain-source voltage. To design basic series-shunt SPST switches and isolation-improved SPST switches, we applied this model to commercial microwave circuit simulator. The improved SPST switches exhibited 0.302dB insertion loss, 35.762dB isolation, 1.249 input VSWR, 1.254 output VSWR, and about 15.7dBm PldB with 0/-3V control voltages at 3GHz.

Effect of Ginseng Saponin on Alcohol Metabolism in the Animal Body (인삼사포닌이 동물생체의 주정대사에 미치는 영향)

  • Joo, Chung-No
    • Journal of Ginseng Research
    • /
    • v.16 no.3
    • /
    • pp.222-227
    • /
    • 1992
  • Unlike carbohydrats and fats, alcohol is essentially foreign to the body and it is known that the body get rid of it by oxidizing alcohol maily in the liver. Acetaldehyde is produced during ethanol metabolism and is known to be oxidized mainly by aldehyde dehydrogenase (ALDH). ALDH activity was found mainly in the mitochondrial fraction but a significant ALDH activity was also present in microsomal and cytosol fraction. Wistar rats (150~200 g, male) were given freely with 12% ethanol (Control) and/or 12% ethanol containing 0.1% ginseng saponins (Test) instead of water for 6 days and the liver was analyzed. ALDH activities of both control and test group were lower than that of normal group but test AkDH was less inhibited than control. ADH activies of both control and test were slightly higher than that of normal group but our previous data showed that it became gradually steady after prolonged ethanol feeding. MEOS activities of both control and test group were much higher than that of normal group. MEOS enzymes are inducible but the activity of test group was greatly higher than that of control. Ethanol containing [1-i4C] ethanol (5 $\mu$Ci) was injected to the above three groups and 30 min later, the distribution of radioactivity of hepatic lipids was investigated. Radioactivities of hepatic lipids of both control and test group were higher than that of normal group, however, that of test group was much lower than that of control. Analysis of individual lipids showed that phospholipid biosynthesis was significantly impaired and fatty acid and triglycerides biosynthesis were greatly stimulated. However, it was realized that the saponin prevented phospholipid biosynthesis depression and the increase of triglyceride biosynthesis considerably. It seemed that the saponin might stimulate ADH, ALDH and MEOS and the acetaldehyde formed would be removed faster. The excess hydrogen can be shunt more quickly into lipid biosynthesis. Electron microscopic observation showed that the hepatic cell of control group was si gnificantly damaged. Mitochondria were swollen and rough endoplasmic reticulum were dilated, however, hepatocytes of test group were not damaged.

  • PDF

스퍼터링 및 셀렌화 공정 조건에 따른 C(IG)Se2 박막태양전지 제작과 특성

  • Choe, Seung-Hun;Son, Yeong-Ho;Jeong, Myeong-Hyo;Park, Jung-Jin;Lee, Jang-Hui;Kim, In-Su;Hong, Yeong-Ho;Yun, Jong-O
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.362-363
    • /
    • 2011
  • 태양광 발전산업에서 현재 주류인 결정 실리콘 태양전지의 변환효율은 꾸준히 향상되고 있으나, 태양전지의 가격이 매년 서서히 하강되고 있는 실정에서 결정질 실리콘 가격의 상승 등으로 부가가치창출에 어려움이 있으며, 생산 원가를 낮출 수 있는 태양전지 제조기술로는 2세대 태양전지로 불리는 박막형이 현재의 대안이며, 특히 에너지 변환 효율과 생산 원가에서 장점이 있는 것이 CIGS 박막태양전지로 판단된다. 화합물반도체 베이스인 CIGS 박막태양전지는 연구실에서는 세계적으로 20.3% 높은 효율을 보고하고 있으며, 모듈급에서도 13% 효율로 생산이 시작되고 있다. 국내에서도 연구실 규모뿐만 아니라 대면적(모듈급) CIGS 박막 태양전지 증착용 장비, 제조공정 등의 기술개발이 진행되고 있다. CIGSe2를 광흡수층으로 하는 CIGSe2 박막 태양전지의 구조는 여러 층의 단위박막(하부전극, 광흡수층, 버퍼층, 상부투명전극)을 순차적으로 형성시켜 만든다. 본 연구에서 광흡수층은 스퍼터링 방법으로 CIG precusor를 먼저 만들고, 그 위에 증발법으로 Se를 증착한 다음, 열처리 조건으로 CIGSe2 박막태양전지를 제작하였다. 제작된 CIGSe2 박막태양전지는 열처리 조건에 따라서 에너지 변환효율이 3.3에서 9.5%까지 다양하게 측정되었으며, 본 연구의 최고효율이 측정된 디바이스에서 개방전압은 0.48 V, 전류밀도는 33 mA/cm였으며, 그리드 전극을 제외한 디바이스의 면적은 0.57 cm2였다. 본 연구에서는 셀렌화 열처리 조건에 따른 CIGSe2 박막태양전지의 효율 측면을 고려하였지만, 더 높은 에너지 변환효율을 갖기 위해서 좀 더 높은 에너지 밴드갭과 개방전압, 낮은 직렬저항과 높은 shunt 저항 값 등의 상호 의존성에 대해서 연구결과들을 논하고자 한다.

  • PDF

A Study on Future System Construction Using WSCR Strengthness Index based on Python (Python 기반 WSCR 강건 지수를 이용한 미래계통 구축에 관한 연구)

  • Park, Seong-Jun;Hur, Jin;Kim, Hyun-Jin;Cho, Yoon-Sung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.8
    • /
    • pp.994-1001
    • /
    • 2018
  • In this paper, to studied about future power system construction using PSS / E-Python API. Python-based future system automatical construction methods and modeling of renewable sources. it confirmed the stability of the powert system for each renewable area by calculating the weighted short circuit ratio (WSCR) index. it calculated the short circuit ratio (SCR) and selected the transmission line linkage scenario to improve the stability of vulnerable areas. it confirmed the WSCR index improvement through the selected transmission line linkage of scenario, and analyzed the stability of the renewable power system applying the scenario. It describes Facts and Shunt devices adjustment for the load flow convergence. It describes the stable methed of the bus voltage through the transformer Ratio Tap adjustment. By performing PSS/E ASCC using the Python it was performed three-phase short circuit fault capacity analysis, it is confirmed whether excess of the fault current circuit breaker capacity. In order to contingency accident analysis, it have described the generation of one or two line list of each areas using the Python. The list is used to contingency analysis and describe the soluted of the transmission line overload through comparison before and after adding the scenario line.

The solar cell modeling using Lambert W-function (Lambert W 함수를 이용한 태양전지 모델링)

  • Bae, Jong-Guk;Kang, Gi-Hwan;Kim, Kyung-Soo;Yu, Gwon-Jong;Ahn, Hyung-Geun;Han, Deuk-Young
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.278-281
    • /
    • 2011
  • This system can predict the maximum output about all illumination levels so that the PV system designer can design the system having the best efficiency. For the output prediction exact about the solar cell, that is the device the basis most in the PV system, the basis has to be in order to try this way. The solution based on Lambert W-function are presented to express the transcendental current-voltage characteristic containing parasitic power consuming parameters like series and shunt resistances. A simple and efficient method for the extraction of a single current-voltage (I-V) curve under the constant illumination level is proposed. With the help of the Lambert W function, the explicit analytic expression for I is obtained. And the explicit analytic expression for V is obtained. This analytic expression is directly used to fit the experimental data and extract the device parameters. The I-V curve of the solar cell was expressed through the modeling using Lambert W-function and the numerical formula where there is the difficulty could be logarithmically expressed This method expresses with the I-V curve through the modeling using Lambert W-function which adds other loss ingredients to the equation2 as to the research afterward. And the solar cell goes as small and this I-V curve can predict the power penalty in the system unit.

  • PDF

Management of Permanent Tracheostomal Stenosis by Tracheal Advancement Flap (기관전진피판술을 이용한 영구기관 개구협착의 치료)

  • Choi, Jong-Ouck;Min, Hun-Ki;Choi, Geon;Jung, Kwang-Yoon;Kim, Young-Ho;Park, Chan;Lee, Byeong-Ki
    • Korean Journal of Bronchoesophagology
    • /
    • v.1 no.1
    • /
    • pp.136-141
    • /
    • 1995
  • Tracheostomal stenosis after total laryngectomy is a distressing complication which con-tributes significantly to both psychosocial and physical morbidity according to nature and severity in laryngectomee. Sternal stenosis will compromise not only optimal air exchange, crust formation but also the ability to clear tracheobronchial secretion, so pneumonia and atelectasis will develop. Having a number of procedure recommended for correction of such stenosis with limited results. We developed new technique which is based on tracheal advancement flap had been ap-plied to 12 patients, successfully. We think that total or partial tracheal advancement flap technique Is useful for widening the stoma and advantages of this method are following. 1. Simple technique. possible under local anesthesia 2. Healthy tracheal ring facilities width control 3. Less chance of refractory scar stenosis 4. Tracheoesophageal shunt can be constructed after the partial advancement flap.

  • PDF

Correlation of B-type natriuretic peptide levels and echocardiographic parameters in preterm infants with patent ductus arteriosus

  • Jeong, Hyun Ah;Shin, Jeonghee;Kim, Eunji;Lee, Eun Hee;Choi, Byung Min;Son, Chang Sung;Lee, Joo Won
    • Clinical and Experimental Pediatrics
    • /
    • v.59 no.4
    • /
    • pp.183-189
    • /
    • 2016
  • Purpose: This study aimed to evaluate the correlation, according to postnatal age, between plasma B-type natriuretic peptide (BNP) levels and echocardiographic parameters for the assessment of patent ductus arteriosus (PDA) in preterm infants with respiratory distress. Methods: We enrolled 42 preterm infants with respiratory distress who underwent serial echocardiographic evaluation with simultaneous plasma BNP measurements until ductal closure. The correlations between BNP levels and the following 4 representative echocardiographic parameters were studied: diameter of the ductus arteriosus (DA), ratio of the left atrial diameter to the aortic diameter (LA/Ao), ratio of the PDA diameter to the infant's left pulmonary artery diameter (PDA/LPA), and the antegrade diastolic flow of LPA (DFLPA). Results: BNP levels were significantly correlated to the magnitude of the ductal shunt, comprising the DA diameter, PDA/LPA ratio, LA/Ao ratio, and antegrade DFLPA for the overall study period. The earliest significant correlation, starting from postnatal day 2, was observed between the LA/Ao ratio and BNP levels. The PDA/LPA ratio and the antegrade DFLPA showed significant correlations with BNP levels postnatal day 3 onward, and with the DA diameter, postnatal day 5 onward. Conclusion: BNP levels and echocardiographic parameters showed a positive correlation, but the significance of the correlations differed according to the postnatal age, especially during the first few days of life.

Analysis on Temperature Dependence of Crystalline Silicon Solar Cells with Different Emitter Types for Desert Environment (사막형 결정질 실리콘 태양전지의 에미터 구조에 따른 온도 별 특성 변화 분석)

  • Nam, Yoon Chung;Kim, Soo Min;Kang, Yoonmook;Lee, Hae-Seok;Kim, Donghwan
    • Current Photovoltaic Research
    • /
    • v.2 no.3
    • /
    • pp.135-139
    • /
    • 2014
  • Different power output of solar cells can be observed at high-temperature regions such as desert areas. In this study, performance dependence on operating temperature of crystalline silicon solar cells with different emitter types was analyzed. Based on the light current-voltage (LIV) measurement, temperature coefficients of short-circuit current density ($J_{SC}$), open-circuit voltage ($V_{OC}$), fill factor (FF) and power conversion efficiency were measured and compared for two groups of crystalline silicon solar cells with different emitter types. One group had homogeneously doped (conventional) emitter and another selectively doped (selective) emitter. Varying the operating temperature from 25 to 40, 60, and $80^{\circ}C$, LIV characteristics of the cells were measured and the properties of saturation current densities ($J_0$) were extracted from dark current-voltage (DIV) curve. From the DIV data, effect of temperature on the performance of the solar cells with different electrical structures for the emitter was analyzed. Increasing the temperature, both emitter structures showed a slight increase in $J_{SC}$ and a rapid degradation of $V_{OC}$. FF and power conversion efficiency also decreased with the increasing temperature. The degrees of $J_{SC}$ increase and $V_{OC}$ degradation for two groups were compared and explained. Also, FF change was explained by series and shunt resistances from the LIV data. It was concluded that the degradation of solar cells shows different values at different temperatures depending on the emitter type of solar cells.

Effects of Cadmium on Glucose Transport in L6 Myocytes (L6 근육세포에서 포도당 수송능에 미치는 $CdCl_2$의 영향)

  • Kang Donghee;Khil Lee-Yong;park Kwangsik;Lee Byung-Hoon;Moon Chang-Kiu
    • Environmental Analysis Health and Toxicology
    • /
    • v.20 no.1
    • /
    • pp.75-85
    • /
    • 2005
  • This study was aimed to know the effect of cadmium chloride (CdCl₂) on glucose transport in L6 myotube and its action mechanism. CdCl₂ increased the 2-deoxy- (l-3H)-D-glucose (2-DOG) uptake 1.9 and 2.4 fold at 10 and 25 μM respectively. To investigate the stimulating-mechanism of glucose transport induced by CdCl₂, the wortmannin and PD98059 were used as PI3K (phosphatidylinositol 3-kinase) inhibitor and MAPK inhibitor respectively, which did not affect 2-DOG uptake. This fact suggests that CdCl₂ induced 2-DOG uptake may not be concerned to the insulin signalling pathway. Whereas nifedipine, a calcium channel blocker, and trifluoperazine, a calmodulin inhibitor, were found to inhibit the 2-DOG uptake stimulted by CdCl₂. In addition, we also measured the ROS (reactive oxygen species) production and GSH level in L6 myotube to investigate the correlation between the glucose uptake and ROS. CdCl₂(25 μM) increased ROS generation approximately 1.5 fold and changed the cellular GSH level, but GSSG/GSH ratio remained unchanged. CdCl₂ stimulated 2-DOG uptake and ROS generation were inhibited by N-acetylcystein. And BSO pretreatment, a potent inhibitor of γ-GCS, resulted in the dramatic decrease of 2-DOG uptake and also the increase of the sensitivity to cadmium cytotoxicity. The obtained results suggest that CdCl₂-stimulated glucose uptake might be based on the activation of HMP shunt as an antioxidant defense mechanism of the cells.