• Title/Summary/Keyword: short implant

Search Result 187, Processing Time 0.025 seconds

Clinical evaluation of retained preload and cement washout in screw- and cement-retained implant prosthesis (나사 시멘트 유지형 임플란트 보철물의 잔여 전부하 및 시멘트 파손에 대한 임상평가)

  • Chung, Chae-Heon;Son, Mee-Kyoung;Kim, Seok-Gyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.4
    • /
    • pp.301-309
    • /
    • 2015
  • Purpose: The aim of this study was to evaluate the clinical performance of screw- and cement-retained implant prosthesis (SCP) design in terms of retained preload of abutment screws and cement washout. Materials and methods: Patients with the partial posterior edentulous areas comprised the study group. Implants were placed, and SCPs were delivered after 3 to 6 months healing. Follow-up examinations were performed. The implant survival rate and the prosthetic success rate were evaluated. The retained preload ratio of abutment screws and the prosthetic decementation ratio were measured. Results: Twenty one SCPs (forty three implants)in twenty patients were followed up to 64 months. All of the implants survived during the follow-up period (mean follow-up: 34 months). The prosthetic success rate was 100 % considering no abutment, screw, porcelain or metal frame fractures, as well as no screw loosening. The retained preload ratio of SCPs at the end of follow-up period was 97.61% (${\pm}16.29$) and the decementation ratio was 9.5 %. Conclusion: Within the limitations of this clinical study, SCP design showed favorable short-term clinical performances in respect of screw loosening and cement washout.

The Effect of Conscious Sedation on Pain and Anxiety of Implant Surgery (임플란트 수술 시 의식하진정법이 환자의 통증과 불안에 미치는 영향)

  • Kim, Hye-Young;Lee, Su-Young;Cho, Young-Sik
    • Journal of dental hygiene science
    • /
    • v.14 no.3
    • /
    • pp.411-416
    • /
    • 2014
  • The purpose of this study was to examine the effects of conscious sedation on pain and anxiety of patients in implant surgery. A total of 95 patients who underwent implant surgery were included in the study. In this study, the patient's anxiety and pain to evaluate the pre-operative Visual Analogue Scale (VAS), during-operative Pain Question (PQ), post-operative (Short-form McGill Pain Questionnaire [SF-MPQ], VAS) was used for tools such as questionnaires. The data were analyzed using the chi-squire, independent-samples t-test, multiple linear regression analysis. As a result, the pain reduction was significantly different between the sedative dental treatment and non-sedative dental treatment (p<0.05). The finding of the study multiple linear regression analysis showed that operation time, implant surgery experience, gender, age, operation form and Pain Catastrophizing Scale (PCS) with factors that affect the pain and anxiety (p<0.05). According to the results of the study, considered to be necessary to develop intervention strategies effective using the PCS when managing pain and anxiety of behavior management of this implant patient. Thus, it is advised to provide necessary practical guidelines and dental utilization behaviors on patients with conscious sedation.

A Retrospective study on $Br{\aa}nemark$ $TiUnite^{(R)}$ implant for mandibular posterior single tooth replacement (하악 구치부에서 $Br{\aa}nemark$$TiUnite^{(R)}$ implant를 이용한 단일 치아수복의 후향적 연구)

  • Oh, Kyung-Choon;Chae, Gyung-Joon;Jung, Ui-Won;Kim, Chang-Sung;Cho, Kyoo-Sung;Choi, Seong-Ho;Kim, Chong-Kwan;Chai, Jung-Kiu
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.4
    • /
    • pp.705-718
    • /
    • 2007
  • The purpose of this study was to evaluate 6 years cumulative survival rate (CSR, %) of mandibular posterior single tooth implants replaced with $Br{\aa}nemark$ $TiUnite^{(R)}$ implant system. The findings from this study were as followed ; 1. The 112 (111 persons) single implants that were placed in the mandibular posterior region were successful except 4 cases and showed 96.42% CSR. 2. The 55 (55 persons) single implants that were placed in the mandibular first molar region were successful except 2 cases and showed 96.36% survival rate. And, among the 57 (56 persons) single implants replacing the mandibular second molar. 2. failed showing 96.49% survival rate. There was no significant statistical difference. 3. Among the total 112 implants, 5.0mm wide diameter implants were placed in 96 cases(85.7%) showing 96.9% survival rate. 4.0mm standard diameter implants were placed in 16 cases showing 93.8% survival rate. There was no significant statistical difference. 4. Long implants above 10.0mm length were placed 103 cases(91.0%) and showed 96.1% survival rate. Short implants within 8.5mm length were placed 9 cases and showed 100% survival rate. There was no significant statistical difference. 5. 37 implants placed in type I, II bone quality were showed higher survival rate(100%) than that of 52 implants placed in type III, IV bone quality(92.3%). But, there was no significant statistical difference. In conclusion, $Br{\aa}nemark$ $TiUnite^{(R)}$ implant showed successful results when replacing manbibular single molar.

Influence of implant diameter and length changes on initial stability (임플란트의 직경과 길이 변화가 초기 안정성에 미치는 영향)

  • Cho, Jae-Myoung;Cho, Uk;Yun, Mi-Jung;Jeong, Chang-Mo;Jeon, Young-Chan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.3
    • /
    • pp.335-341
    • /
    • 2009
  • Statements of problem: Adequate bone quality and quantity were important to achieve initial stability and to prevent early failures. However there were few published data available regarding the actual effect of dimensional change in implant geometry on initial stability. Purpose: The purpose of the current study was to investigate the influence of diameter and length changes on initial stability of implants. Material and methods: Four types of dummy bone (D1, D2, D3 and D4) consisted of cortical and cancellous layers with different thickness were simulated. Implants which had similar surface area to each other ($3.5{\times}13.0-mm$, $4.0{\times}11.5-mm$, $4.5{\times}10.0-mm$, $5.0{\times}8.5-mm$) were inserted in dummy bones. Implant stability as a function of peak insertion torque and resonance frequency values were recorded for each implant. Results: 1. Bone quality was a major influential factor to achieve initial stability (P <.05). 2. In D1, D2 and D3 dummy bones, implant stability quotient values were not significantly different to each other (P >.05), however insertion torques were increased with wider and shorter implants (P <.05). 3. In D4 dummy bone, implant stability quotient values and insertion torques were decreased with wider and shorter implants (P <.05). Conclusion: From a point of view of initial stability, it is suggested that use of wide and short implant may be helpful in avoiding bone augmentation procedures in area of adequate bone quality.

Case report of esthetic maxillary anterior crown lengthening (상악 전치부에서 심미적 치관 연장술의 치유 양상 보고)

  • Kim, Sun-Ha;Park, Jin-Woo;Suh, Jo-Young;Lee, Jae-Mok
    • Journal of Periodontal and Implant Science
    • /
    • v.39 no.2
    • /
    • pp.199-204
    • /
    • 2009
  • Purpose: Excessive gingival display and short clinical crowns due to altered passive eruptions are major concerns for a considerable number of patients visiting dental clinics. Altered passive eruptions could be corrected through various types of periodontal surgery conformable to a classification. 3 cases are reported here on the esthetic correction of altered passive eruption to evaluate results of crown lengthening procedure. Methods: Three patients whose major complaints were excessive gingival display and short teeth were picked out for this case study. Before treatment, clinical and radiological exam was performed to choose type of surgery. Thickness and width of keratinized gingiva was measured in all three patients then they were treated by surgical methods including flap operation and depigmentation under subsequent diagnosis. Results: Uneventful healing and stable gingival margin were observed in all three patients except recurrence of gingival pigmentation of one patient. Conclusions: The treatment of altered passive eruption requires precise diagnostic procedure and could achieve better esthetic outcomes when it is accompanied by other orthodontic and orthognathic treatment.

Influence of Implant Fixture-Abutment Connection and Abutment Design on Mechanical Strength (임플란트 고정체-지대주 연결부 및 지대주 디자인이 기계적 강도에 미치는 영향)

  • Chun, Mi-Hyun;Jeong, Chang-Mo;Jeon, Young-Chan;Eom, Tae-Gwan;Yoon, Ji-Hoon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.3
    • /
    • pp.269-281
    • /
    • 2008
  • Fatigue or overload can result in mechanical problems of implant components. The mechanical strength in the implant system is dependent on several factors, such as screw and fixture diameters, material, and design of the fixture-abutment connection and abutment. In these factors, the last rules the strength and stability of the fixture-abutment assembly. There have been some previous reports on the mechanical strength of the fixture-abutment assembly with the compressive bending test or short-term cyclic loading test. However, it is restrictive to predict the long-term stability of the implant system with them. The purpose of this study was to evaluate the influence of the design of the fixture-abutment connection and abutment on the mechanical strength and failure mode by conducting the endurance limit test as well as the compressive bending strength test. Tests were performed according to a specified test(ISO/FDIS 14801) in 4 fixture-abutment assemblies of the Osstem implant system: an external butt joint with Cemented abutment (group BJT), an external butt joint with Safe abutment (group BJS), an internal conical joint with Solid abutment (group CJO), and an internal conical joint with ComOcta abutment (group CJT). The following conclusions were drawn within the limitation of this study. Compressive bending strengths were decreased in order of group BJS(1392.0N), group CJO(1261.8N), group BJT(1153.2N), and group CJT(1110.2N). There were no significant differences in compressive bending strengths between group BJT and group CJT(P>.05). Endurance limits were decreased in order of group CJO(600N), group CJT(453N), group BJS(360N), and group BJT(300N). 3. Compressive bending strengths were influenced by the connection and abutment design of the implant system, however endurance limits were affected more considerably by the connection design.

Controlled release of nerve growth factor from heparin-conjugated fibrin gel within the nerve growth factor-delivering implant

  • Lee, Jin-Yong;Kim, Soung-Min;Kim, Myung-Jin;Lee, Jong-Ho
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.40 no.1
    • /
    • pp.3-10
    • /
    • 2014
  • Objectives: Although nerve growth factor (NGF) could promote the functional regeneration of an injured peripheral nerve, it is very difficult for NGF to sustain the therapeutic dose in the defect due to its short half-life. In this study, we loaded the NGF-bound heparin-conjugated fibrin (HCF) gel in the NGF-delivering implants and analyzed the time-dependent release of NGF and its bioactivity to evaluate the clinical effectiveness. Materials and Methods: NGF solution was made of 1.0 mg of NGF and 1.0 mL of phosphate buffered saline (PBS). Experimental group A consisted of three implants, in which $0.25{\mu}L$ of NGF solution, $0.75{\mu}L$ of HCF, $1.0{\mu}L$ of fibrinogen and $2.0{\mu}L$ of thrombin was injected via apex hole with micropipette and gelated, were put into the centrifuge tube. Three implants of experimental group B were prepared with the mixture of $0.5{\mu}L$ of NGF solution, $0.5{\mu}L$ HCF, $1.0{\mu}L$ of fibrinogen and $2.0{\mu}L$ of thrombin. These six centrifuge tubes were filled with 1.0 mL of PBS and stirred in the water-filled beaker at 50 rpm. At 1, 3, 5, 7, 10, and 14 days, 1.0 mL of solution in each tubes was collected and preserved at $-20^{\circ}C$ with adding same amount of fresh PBS. Enzyme-linked immunosorbent assay (ELISA) was done to determine in vitro release profile of NGF and its bioactivity was evaluated with neural differentiation of pheochromocytoma (PC12) cells. Results: The average concentration of released NGF in the group A and B increased for the first 5 days and then gradually decreased. Almost all of NGF was released during 10 days. Released NGF from two groups could promote neural differentiation and neurite outgrowth of PC12 cells and these bioactivity was maintained over 14 days. Conclusion: Controlled release system using NGF-HCF gel via NGF-delivering implant could be an another vehicle of delivering NGF to promote the nerve regeneration of dental implant related nerve damage.

Practicability Strength Assessment of a Bone Metallic Plate at the Femur Fixation (대퇴골(Femur)고정용 골 금속판 제작 및 강도 평가)

  • Kim, Jeong-Lae;Ahn, Chang-Sik;Seo, Byoung-Do
    • Journal of the Ergonomics Society of Korea
    • /
    • v.27 no.2
    • /
    • pp.83-89
    • /
    • 2008
  • Study was developed the metallic plate for fixation in the femur fracture and plates has a firm place in fracture treatment. This plates can be stabilized for fracture fixation as well as biological and dynamical device. The device's designation and sizing has a optimization with bending structural stiffness and strength, known meaning that is reliable regardless of the plate by the short type and long type. The bending strength of the curved metallic long plate has to evaluate a 11,000N and the bending strength of the curved metallic short plate has to evaluate a 6,525N. This see the X-ray image of bending angle made certain of 15$^{\circ}$ at number 2 and same 82.87$^{\circ}$ at number 2, 4, 5, 7, 8, 9, 10 by outside angle, and confirmed 25.26$^{\circ}$ at number 3, 3.68$^{\circ}$ at number 6, 15.64$^{\circ}$ at number 9 by inside angle. This study shows that keep up the metallic plate for fixation in the femur fracture through X-ray Image and the device can be used to support Revision case of Hip Implant and to use a case of Hip screw compression of Hip Neck Fracture. Short plate have a wrapping of femur and long plate have to preserve a pole of femur.

Primary Total Elbow Replacement for Treatment of Complex Distal Humerus Fracture: Outcomes of Short-term Follow-up

  • Kim, Du-Han;Kim, Beom-Soo;Baek, Chung-Sin;Cho, Chul-Hyun
    • Clinics in Shoulder and Elbow
    • /
    • v.23 no.1
    • /
    • pp.20-26
    • /
    • 2020
  • Background: High complication rate after open reduction and internal fixation can lead to use of primary total elbow replacement (TER) in treatment of complex distal humerus fractures in elderly patients. The purpose of this study was to investigate the short-term outcomes and complications after primary TER in patients with complex distal humerus fracture. Methods: Nine patients with acute complex distal humerus fracture were treated by primary TER using the semiconstrained Coonrad-Morrey prosthesis. The mean age of patients was 72.7 years (range, 63-85 years). Clinical and radiographic outcomes were evaluated over a mean follow-up of 29.0 months (range, 12-65 months) using visual analog scale (VAS) score for pain; Mayo elbow performance score (MEPS); Quick Disabilities of the Arm, Shoulder, and Hand (Quick-DASH) score; and serial plain radiographs. Complications were also evaluated. Results: At the final follow-up, mean VAS, MEPS, and Quick-DASH scores were 1.2, 80.5, and 20, respectively. The mean range of motion was 127.7° of flexion, 13.8° of extension, 73.3° of pronation, and 74.4° of supination. There was no evidence of bushing wear or high-grade implant loosening on serial plain radiographs. Three complications (33.3%) comprising two periprosthetic fractures and one ulnar neuropathy were observed. Conclusions: Primary TER for treatment of complex distal humerus fractures in elderly patients yielded satisfactory short-term outcomes. However, surgeons should consider the high complication rate after primary TER.

Design and Characteristics of Modern Power MOSFETs for Integrated Circuits

  • Bang, Yeon-Seop
    • The Magazine of the IEIE
    • /
    • v.37 no.8
    • /
    • pp.50-59
    • /
    • 2010
  • $0.18-{\mu}m$ high voltage technology 13.5V high voltage well-based symmetric EDMOS isolated by MTI was designed and fabricated. Using calibrated process and device model parameters, the characteristics of the symmetric and asymmetric EDMOS have been simulated. The asymmetric EDMOS has higher performance, better $R_{sp}$ / BVDSS figure-of-merit, short-channel immunity and smaller pitch size than the symmetric EDMOS. The asymmetric EDMOST is a good candidate for low-power and smaller source driver chips. The low voltage logic well-based EDMOS process has advantages over high voltage well-based EDMOS in process cost by eliminating the process steps of high-voltage well/drift implant, high-temperature long-time thermal steps, etc. The specific on-resistance of our well-designed logic well-based EDMOSTs is compatible with the smallest one published. TCAD simulation and measurement results show that the improved logic well-based nEDMOS has better electrical characteristics than those of the conventional one. The improved EDMOS proposed in this paper is an excellent candidate to be integrated with low voltage logic devices for high-performance low-power low-cost chips.

  • PDF