• 제목/요약/키워드: shoes insole

검색결과 55건 처리시간 0.022초

뒤꿈치 인솔착용과 시각통제 유무가 하이힐 착용 시 균형관련 지수에 미치는 영향 (Influence of Heel Insole and Visual Control on Body Sway Index with High-heeled Shoes)

  • 윤정규
    • 대한물리의학회지
    • /
    • 제9권4호
    • /
    • pp.407-413
    • /
    • 2014
  • PURPOSE: We investigated the influence of heel insole and visual control on body sway index with high-heeled shoes. METHODS: The subjects of this study were 61 healthy students. None of the participants had any orthopedic or neurologic alterations. C90 area, C90 angle, trace length, sway average velocity were measured using a force plate by BT4. The variables were measured both with insole and without insole when wearing high-heeled shoes under the conditions of eyes open and eyes closed. The collected data were analyzed using the Kolmogorov-Smirnov test and paired t-test. RESULTS: When wearing high-heeled shoes with insole under the conditions of eyes open, trace length, C90 area, velocity were significantly more decreased than without insole (p<.01). When wearing high-heeled shoes with insole under the conditions of eyes closed, only C90 area was significantly more decreased than without insole (p<.05). When wearing high-heeled shoes with insole under the conditions of eyes open, trace length, C90 area, velocity were significantly more decreased than under the conditions of eyes closed (p<.01). CONCLUSION: The present study demonstrates that the use of high-heeled shoes with insole supported from heel to midfoot more increased static balance than without insole under the conditions of eyes open.

안전화 형태와 인솔착용 유무에 따른 보행동작시 하지부위에 대한 운동학적 부하 분석 (A Study on the Kinematic Variables in Different Safety Shoes and Applying Insole During Walking)

  • 김중진;최상복;차상은
    • 한국안전학회지
    • /
    • 제23권1호
    • /
    • pp.35-45
    • /
    • 2008
  • This study was performed to compare the kinematics among three different safety shoes(type 1: ergonomically designed and high quality shoes, 2: curved and cushioned safety shoes, and 3: regular safety shoes) and to find the effect of insole during walking. Ten healthy subjects were recruited for this study. The range of motion of knee and ankle joint, angle of rear foot and angle of heel contact were measured using a three dimensional motion analysis system. In the second peak, the angle of heel contact showed statistically significant difference between safety shoes and insole, however, there was no statistical significance among three different safety shoes. The angle of ankle increased significantly at initial contact, first peak, the second peak and the toe off phase compared with type 1 and 2 safety shoes, and the angle of ankle showed statistically significant difference between with and without applying the insole. During the first peak, the second peak and the toe off phase, the angle of knee was statistical significance between safety shoes and insole. In heel contact, the angles of Achilles' tendon showed statistically significant difference between safety shoes and insole. The rear foot angles showed statistically significant difference between safety shoes and insole during heel contact and early heel contact. These results suggest that the type 1 safety shoes were superior to others in the statistics, and applying insole could be a possible method to prevent fatigue of lower extremity and musculoskeletal disorders. Further studies are needed to find the effect of ergonomically designed safety shoes and insole on practical value in prevention of musculoskeletal disorder, fatigue and satisfaction of workers.

안전화 형태와 Insole 착용 유무에 따른 보행동작시 하지부위에 대한 지면반발력과 압력분포 부하 (A study on the ground reaction forces and plantar pressure variables in different safety shoes and applying insole during walking)

  • 김중진;최상복;차상은
    • 한국산업보건학회지
    • /
    • 제17권2호
    • /
    • pp.131-143
    • /
    • 2007
  • The purpose of this study was to compare the ground reaction forces and plantar pressure variables among three different safety shoes (Type 1: ergonomically designed and high quality shoes, 2: curved and cushioned safety hoes, and 3: regular safety shoes) and to find the effect of insole during walking. Ten healthy subjects were recruited for this study. The ground reaction force was measured using a 3 dimensional motion analysis system. Plantar pressures were measured Pedar Mobile foot pressure scan system. The ground reaction force variables were not significantly different among three different shoe types and insole conditions. After insertion insole, plantar pressure distributions were improved. These results suggest that the type 1 safety shoes was superior than other safety shoes in the statistics, and applying insole could be a possible method to prevent fatigue of lower extremity and musculoskeletal disorders. Further studies are needed to find the effect of ergonomically designed safety shoes design and insole on practical value prevention of musculoskeletal disorder, fatigue and satisfaction of workers.

편마비 환자의 비손상측 안창 착용이 보행에 미치는 영향 (Effect of uneffected side insole on Gait Pattern in Hemiplegia Patients)

  • 유재응;정석
    • 대한물리치료과학회지
    • /
    • 제10권2호
    • /
    • pp.37-41
    • /
    • 2003
  • The aim of this study is to present the basic reference data Effect of uneffected side insole on Gait Pattern in Hemiplegia Patients. The basic gait parameters were extracted from 10 Adult Hemiplegia Patients, 5 left Hemiplegia Patients and 5 right Hemiplegia Patients, 50 to 60 years of age using VICON 512 Motion Analyzer. The results were as follows; 1) The mean Cadence of the shoes to the 1cm insole in shoes were $70.58{\pm}12.67\;steps/min$, to $77.28{\pm}14.58\;steps/min$.(p>0.05) 2) The mean Walking Speed of the shoes to the 1cm insole in shoes were $0.40{\pm}0.17\;m/s$, to $0.49{\pm}0.18\;m/s$.(p>0.05) 3) The mean Stride Length of the shoes to the 1cm insole in shoes were $0.67{\pm}0.20\;m$, to $0.75{\pm}0.19m$.(p>0.05) 4) The mean anterior angles of pint on the pelvic tilt for different the shoes to the 1cm insole in shoes were $13.22{\pm}7.25^{\circ}$, to $11.68{\pm}4.02^{\circ}$.(p>0.06) 5) The mean maximal angles of pint on the hip flexion motion for different the shoes to the 1cm insole in shoes were $24.62{\pm}8.35^{\circ}$, to $24.74{\pm}9.12^{\circ}$.(p>0.05) 6) The mean maximal angles of joint on the knee flexion motion for different the shoes to the 1cm insole in shoes were $34.27{\pm}16.71^{\circ}$, to $35.93{\pm}18.22^{\circ}$.(p>0.05) insole in shoes were $15.97{\pm}7.72^{\circ}$, to $18.77{\pm}11.03^{\circ}$.(p>0.05) 7) The mean maximal angles of joint on the ankle dorsiflexion motion for different the shoes to the 1cm. 8) The mean maximal angles of joint on the ankle plantarflexion motion for different the shoes to the 1cm insole in shoes were $-4.24{\pm}10.66^{\circ}$, to $-7.04{\pm}11.00^{\circ}$.(p<0.05)

  • PDF

Removal Effect of Odor Gases Generated in Foaming Process of Shoes Insole with Addition of Self Actuated Photocatalyst Prepared by Sol-gel Method

  • Choi, Sei Young
    • Elastomers and Composites
    • /
    • 제50권2호
    • /
    • pp.132-137
    • /
    • 2015
  • A self actuated photocatalyst $Weltouch^{(R)}$ used to the remove the odor gases generated in the foaming process of shoes insole was prepared by sol-gel method and studied its property. Specially, with mixing $Weltouch^{(R)}$ in the foaming process of shoes insole, the physical functionality such as specific gravity, hardness, elongation, compression set was studied. The physical functionality of shoes insole was no variation by added $Weltouch^{(R)}$. The odor gases generated in the foaming process of shoes insole was detected to be reduced to 60~80% by self actuated photocataylst $Weltouch^{(R)}$ even in the dark conditions, which was observed for both anatase and rutile phase.

키높이 깔창이 성인남성의 보행 및 발의 압력분포에 미치는 영향 (The Effect of Height Increase Elevator Shoes Insole on Gait and Foot Pressure)

  • 구봉오
    • 대한물리의학회지
    • /
    • 제6권2호
    • /
    • pp.199-205
    • /
    • 2011
  • Purpose: The purpose of this study was to investigate the effect of 0cm, 2.5cm, 5cm height increase elevator shoes insole on gait and foot pressure Methods: Fifteen young adult were recruited this study. Gait and foot was measured by Gait AnalyzerTM(Tech Storm Inc. korea). Statistical analysis was used one-way ANOVA to know difference between 0cm, 2.5cm insole and 5cm insole Results: There was no significantly difference on foot length, foot width, foot angle, step time during gait. But step length and step width was significantly difference during gait. There was no significantly difference on gait ratio during stance phase. There was significantly difference on forefoot pressure and rearfoot pressure ratio. Conclusion: These results indicate that height increase elevator shoes insole may be caused step length, step width decreaseed during gait. It caused forefoot pressure increased and rearfoot pressure decreased on foot.

인솔 차이에 따른 런닝화의 운동역학적 비교 (The Biomechanical Comparison of Running Shoes According to the Difference of Insole)

  • 진영완;신성훈
    • 한국운동역학회지
    • /
    • 제17권2호
    • /
    • pp.51-59
    • /
    • 2007
  • These studies show that I applied to functional insole (a specific A company) for minimizing shocks and sprain people's ankle arising from running. How to an effect on human body which studied a kinematics and kinetics from 10 college students during experiments. This study imposes several conditions by barefoot, normal running shoes and put functional insole shoes ran under average $2.0{\pm}0.24\;m$/sec by motion analysis and ground reaction force that used to specific A company. First of all, motion analysis was caused by achilles tendon angle, angle of the lower leg, angle of the knee, initial sole angle and barefoot angle. The result of comparative analysis can be summarized as below. Motion analysis showed that statically approximates other results from achilles tendon angle (p<.01), initial ankle angle(p<.05), initial sole angle(p<.001) and barefoot angle(p<.001). Ground reaction force also showed that statically approximates other results from impact peak timing (p<.001), Maximum loading rate(p<.001), Maximum loading rate timing (p<.001) and impulse of first 20 percent (p<.001). Above experiment values known that there was statically difference between Motion analysis and Ground reaction force under absorbing of the functional insole shoes which was not have an effect on our body for kinetics and kinematics.

유한요소법을 이용한 신발의 열전달 해석 및 설계 (Heat Transfer Analysis and Design of Shoes Using Finite Element Method)

  • 김병수;문병영
    • Elastomers and Composites
    • /
    • 제38권3호
    • /
    • pp.206-212
    • /
    • 2003
  • 본 논문에서는 인솔에 coolant가 있는 골프화에 대해서 이론적인 해석방법과 설계기술을 연구하였다. 골프화를 구성하고 있는 인솔의 형상과 미드솔, 아웃솔을 고려하여 유한요소법으로 모델링하였다. 열전달을 위한 유한요소의 경계조건으로는 인간발의 표준적인 온도가 사용되었다. 열전달해석을 위해 상용프로그램으로는 MARC V7.3를 사용하였고 온도 및 인솔의 열전도량을 구했다. 본 연구에서 열전달의 특성에 따라서 유한요소법의 결과가 다르게 나온다는 결론을 얻었다. 본 연구 결과는 골프화 해석에 보다 나은 이해를 제공해준다. 더욱이, 본 연구결과는 골프화 관련 업체에서 활용할 경우 보다 효과적으로 설계하도록 도울 것이라고 믿는다.

운동효과 증진을 위한 Arch Support 효과에 관한 연구 (A Study on the Effect of Arch Support for Improvement of Muscle Activity)

  • 이창민;김진훈;오연주;김대웅
    • 대한인간공학회지
    • /
    • 제27권3호
    • /
    • pp.71-79
    • /
    • 2008
  • Walking shoes for walking and jogging have been used to enjoy lots of leisure time. Functional shoes such as walking shoes have special functions to improve body motility by changing of shoe shapes. The walking shoes could improve the motility by structural transformation of outsole as increase degrees of heel and toe. The study on insoles has not been conducted enough on the contrary of the study of outsole. The purpose of this study is to perform ergonomics analysis whether the Arch Supported insoles have an improving effect of muscle activities or not. Experiments were performed with 6 subjects who are health and haven't experienced any diseases past. EMG(Electromyography) and Foot Pressures were measured repeatedly for 5 seconds at 0 hour, after 1 hour and after 2 hours of walking. Insoles used for experiment are normal insole, insole inserted Arch Support and pad. The electrodes for EMG measurement were set on waist (erector spinae), and thigh (vastus lateralis), calf (gastrocnemius). Evaluations of EMG were analyzed by shift of MF (Median Frequency) and MPF (Mean Power Frequency). Foot Pressure was analyzed by mean pressure of feet and change of walking time. As results, Arch Support insole had larger frequency shift value than that of normal insole. Frequency shift between Arch Support insoles and normal insole showed significant difference on 95% confidence interval. And insole 1 has the highest value of frequency shift. For results of foot pressure, Arch Support insoles show continuous decreasing tendency when comparing with normal insoles by changing of times. Also, insole 1 has the highest decreasing value of foot pressure. Therefore, this study presented that the Arch Support insole can promote muscle activities and improves comfort for a prolonged walking.

런닝화의 일반인솔과 기능성인솔의 운동역학적 비교 분석 (Biomechanical Comparison Analysis of Popular Insole and Functional Insole of Running Shoes)

  • 신성훈;진영완
    • 한국운동역학회지
    • /
    • 제16권3호
    • /
    • pp.9-18
    • /
    • 2006
  • These studies show that I applied to functional insole (a specific S company) for minimizing shocks and sprain people's ankle arising from running. How to an effect on human body which studied a kinematics and kinetics from 10 college students during experiments. This study imposes several conditions by barefoot, normal running shoes and put functional insole shoes ran under average $2.0{\pm}0.24$ meter per second by motion analysis, ground reaction force and electromyography that used to specific A company. First of all, Motion analysis was caused by Achilles tendon angle, Angle of the lower leg, Angle of the knee, Initial sole angle and Barefoot angle. Second, Contact time, Vertical impact force peak timing, Vertical active force and Active force timing, and Maximum loading rate under impulse of first 20 percent and Value of total impulse caused Ground reaction force. Third. The tendon fo Quadriceps femoris, Biceps femoris, Tibialis anterior and gastronemius medials caused. electromyography. 1. Ground reaction force also showed that statically approximates other results from impact peak timing (p.001), Maximum loading rate(p<.001), Maximum loading rate timing (p<.001) and impulse of first 20 percent (p<.001). 2 Electromyography showed that averagely was distinguished from other factors, and did not show about that. Above experiment values known that there was statically difference between Motion analysis and Ground reaction force under absorbing of the functional insole shoes which was not have an effect on our body for kinetics and kinematics.