• Title/Summary/Keyword: set-up reproducibility

Search Result 40, Processing Time 0.02 seconds

A study on the effect of collimator angle on PAN-Pelvis volumetric modulated arc therapy (VMAT) including junction (접합부를 포함한 PAN-전골반암 VMAT 치료 계획 시 콜리메이터 각도의 영향에 관한 고찰)

  • Kim, Hyeon Yeong;Chang, Nam Jun;Jung, Hae Youn;Jeong, Yun Ju;Won, Hui Su;Seok, Jin Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.32
    • /
    • pp.61-71
    • /
    • 2020
  • Purpose: To investigate the effect of collimator angle on plan quality of PAN-Pelvis Multi-isocenter VMAT plan, dose reproducibility at the junction and impact on set-up error at the junction. Material and method: 10 adult patients with whole pelvis cancer including PAN were selected for the study. Using Trubeam STx equipped with HD MLC, we changed the collimator angle to 20°, 30°, and 45° except 10° which was the default collimator angle in the Eclipse(version 13.7) and all other treatment conditions were set to be the same for each patient and four plans were established also. To evaluate these plans, PTV coverage, coverage index(CVI) and homogeneity index (HI) were compared and clinical indicators for each treatment sites in normal tissues were analyzed. To evaluate dose reproducibility at the junction, the absolute dose was measured using a Falmer type ionization chamber and dose changes at the junction were evaluated by moving the position of the isocenter in and out 1~3mm and setting up the virtual volume at the junction. Result: CVI mean value was PTV-45 0.985±0.004, PTV-55 0.998±0.003 at 45° and HI mean value was PTV-45 1.140±0.074, and PTV-55 1.031±0.074 at 45° which were closest to 1. V20Gy of the kidneys decreased by 9.66% and average dose of bladder and V30 decreased by 1.88% and 2.16% at 45° compared to 10° for the critical organs. The dose value at the junction of the plan and the actual measured were within 0.3% and within tolerance. At the junction, due to set-up error the maximum dose increased to 14.56%, 9.88%, 8.03%, and 7.05%, at 10°, 20°, 30°, 45°, and the minimum dose decreased to 13.18%, 10.91%, 8.42%, and 4.53%, at 10°, 20°, 30°, 45° Conclusion: In terms of CVI, HI of PTV and critical organ protection, overall improved values were shown as the collimator angle increased. The impact on set-up error at the junction by collimator angle decreased as the angle increased and it will help improve the anxiety about the set up error. In conclusion, the collimator angle should be recognized as a factor that can affect the quality of the multi-isocenter VMAT plan and the dose at the junction, and be careful in setting the collimator angle in the treatment plan.

Resistive Switching in Vapor Phase Polymerized Poly (3, 4-ethylenedioxythiophene)

  • Kalode, P.Y.;Seong, Myeong-Mo
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.384-384
    • /
    • 2012
  • We report nonvolatile memory properties of poly (3, 4-ethylenedioxythiophene) (PEDOT) thin films grown by vapor phase polymerization using FeCl3 as an oxidant. Liquid-bridge-mediated transfer method was employed to remove FeCl3 for generation of pure PEDOT thin films. From the electrical measurement of memory device, we observed voltage induced bipolar resistive switching behavior with ON/OFF ratio of 103 and reproducibility of more than 103 dc sweeping cycles. ON and OFF states were stable up to 104 seconds without significant degradation. Cyclic voltammetry data illustrates resistive switching effect can be attributed to formation and rupture of conducting paths due to oxidation and reduction of PEDOT. The maximum current before reset process was found to be increase linearly with increase in compliance current applied during set process.

  • PDF

Pressure and Temperature Control and HPHT Diamond Synthesis Using FB25 Type Belt Apparatus

  • Fukunaga, O.;Ko, Y.S.;Ohashi, N.
    • The Korean Journal of Ceramics
    • /
    • v.4 no.1
    • /
    • pp.5-8
    • /
    • 1998
  • Flat belt(FB) type high pressure apparatus has been succesfully utilized in various high pressure experimental stations in Korea and Japan to conduct HPHT (high pressure and high temperature) diamond synthesis. Present paper discusses pressure calibration of FB apparatus at high temperature to establish P-T condition of diamond synthesis. We also present some examples of controling P-T condition through careful experimental set-up of the high pressure sample cells. Finally we discuss reproducibility of pressure and temperature condition of the HPHT diamond synthesis.

  • PDF

Usability assessment of thermoplastic Bolus for skin VMAT radiotherapy (피부 병변에 대한 VMAT 치료 시 열가소성 bolus의 유용성 평가: case review)

  • Kim, Min Soo;Kim, Joo Ho;Shin, Hyun Kyung;Cho, Min Seok;Park, Ga Yeon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.32
    • /
    • pp.85-92
    • /
    • 2020
  • Purpose: To find out the advantages of thermoplastic bolus compared to conventional bolus, which is mainly used in clinical practice, We evaluated Two cases in terms of dose and location reproducibility to assess Usability of thermoplastic Bolus for skin VMAT radiotherapy. Materials and Methods: Two patient's treated with left breast skin lesion were simulated using thermoplastic Bolus and planned with 2arc VMAT. the prescription dose was irradiated to 95% or more of the target volume. We evaluated The reproducibility of the bolus position by measuring the length of the air gap in the CBCT (Cone Beam CT) image. to evaluate dose reproducibility, we compared The dose distribution in the plan and CBCT and measured in vivo for patient 2. Results: The difference between the air gap in patient 1's simulation CT and the mean air gap (M1) during 10 treatments in the CBCT image was -0.42±1.24mm. In patient 2, the difference between the average air gap between the skin and the bolus (M2) during 14 treatments was -1.08±1.3mm, and the air gap between the bolus (M3) was 0.49±1.16. The difference in the dose distribution between Plan CT and CBCT was -1.38% for PTV1 D95 and 0.39% for SKIN (max) in patient 1. In patient 2, PTV1 D95 showed a difference of 0.63% and SKIN (max) -0.53%. The in vivo measurement showed a difference of -1.47% from the planned dose. Conclusion: thermoplastic Bolus is simpler and takes less time to manufacture compared to those produced by 3D printer. Also compared to conventional bolus, it has high reproducibility in the set-up side and stable results in terms of dose delivery.

Evaluation of Manufactured Device for Radiation therapy in Head and Neck Cancer (두경부암 환자의 방사선 치료시 자체 제작한 고정용구 (Shoulder Retractor)에 대한 유용성 평가)

  • Kim, Tae Jun;Jin, Sun Sik;Kim, Dong Hyun;Kim, Dong Wook;Chung, Weon Kuu;Kim, Kyoung Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.99-105
    • /
    • 2014
  • Purpose : We compared the set-up accuracy and right-left Shoulder position variation of the manufactured device and other commercial shoulder-retractors in the head and neck radiation treatment. Materials and Methods : Six patients consist of three groups which were used three different Shoulder retractors. We measured position corrections of left and right Shoulder and the couch after the image guidance by using on board imager (OBI) for six head and neck patients who has the extended target to the neck node lower region. Results : The position variation correction of left (right) Shoulder after image guidance were $1.07{\pm}3.99mm$ ($-4.35{\pm}2.09mm$), $-0.37{\pm}5.91mm$ ($1.26{\pm}5.28mm$), $-0.63{\pm}2.44mm$ ($0.25{\pm}1.61mm$) for group A, B and C. The vertical, lateral, longitudinal position and angular corrections of the couch after image guidance were $-2.06{\pm}2.68$, $-1.11{\pm}8.15$, $0.34{\pm}3.78mm$, and $0.51{\pm}0.77$ degree for group A, $-1.18{\pm}1.82$, $-0.94{\pm}2.13$, $-0.67{\pm}1.98mm$, and $0.91{\pm}1.04$ degree for group B and $0.12{\pm}2.18$, $-0.79{\pm}2.64$, $0.79{\pm}2.64$, and $0.00{\pm}0.49$ degree for group C. Conclusion : In this preliminary study, we found the positioning accuracy of the manufactured Shoulder retractor is comparable to other commercial Shoulder retractors. We expect that the reproducibility and accuracy of the patient set-up could be improved by using the home made Shoulder retractor in the head and neck radiation treatment.

Moving Artefacts Detection System for a Pulse Diagnosis System (맥진기를 위한 동잡음 검출 시스템)

  • Lee, Jeon;Woo, Young-Jae;Jeon, Young-Ju;Lee, Yu-Jung;Kim, Jong-Yeol
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.45 no.5
    • /
    • pp.21-27
    • /
    • 2008
  • Despite recent studies on development of pulse diagnosis systems and needs for commercializing them, the reproducibility is one of the most controversial issues as ever. Because the pulse pressure value, which is one of the important parameters to evaluate reproducibility, is very vulnerable to moving artifacts, the reproducibility can not be obtained easily. In this paper, we suggested a moving artefacts detection system for a pulse diagnosis system so that a pulse diagnosis system can be robust to theses kinds of artefacts by excluding the contaminated parts from the pulse wave signal to be analyzed. This moving artifacts detection system was designed to consist of a three-axis accelerometer, an electromyography amplifier and a two-axis tilt sensor. To assess the suitability of the system, we examined the characteristics of each sensor's output signals with regard to the three specific motions such as extension, flexion and rotation. And, we also examined the each sensor's response to the high-frequency and low-frequency moving artifacts while the pulse wave signal was acquired from a pressure sensor for the pulse diagnosis. From these results, we could find that the response to subject's motions would be reflected in electromyography signal first, in accelerometer signals and in tilt sensor sequently. And, the facts that a stable pulse wave can be acquired in two seconds after high frequency or low frequency motions ended, were also found. Consequently, based on these findings, we set up some rules on the moving artifacts detection and designed an algorithm which is fit for our moving artifacts detection system.

Oxygen Permeability Characteristics of the Multi-Cathode Type Dissolved Oxygen Sensor Using the Low Noise Measuring Circuit (저잡음화 계측회로에 의한 다음극형 용존산소센서의 산소투과특성)

  • Rhie, Dong-Hee;Kim, T.J.;Kim, Y.H.;Sung, Yung-Kwon
    • Proceedings of the KIEE Conference
    • /
    • 1998.11c
    • /
    • pp.764-766
    • /
    • 1998
  • An evaluation method for oxygen permeable characteristics of the membrane covering to each cathode of multiple cathode - single anode type dissolved oxygen sensor, which has high reproducibility and is capable of measuring multiple components in solutions. For this purpose, a measuring circuit for the multiple cathode type DO sensor was designed to lower the noise signal by adapting a digital LPF to readout the sensor output accurately. Digital LPF is designed by setting up the transfer function to set the cutoff frequency to 10Hz, and the transfer function is programmed by C language, and then the filtering characteristics are evaluated with the simulation and experiments. Using this LPF added measuring circuit for the multiple cathode type DO sensor, we have obtained the calibration factor for each cathode to calibrate the variation of the output signals. The calibration factor was obtained by measuring the sensor output signal followed by oxygen partial pressure, using the same oxygen permeable membrane at each cathode of the multiple cathode type DO sensor.

  • PDF

Effects of Linear and Nonlinear Shear Deformation on Measurement for Stickiness of Cosmetics Using Rotational Rheometer

  • Bae, Jung-Eun;Ryoo, Joo-Yeon;Kang, Nae-Gyu
    • Korea Journal of Cosmetic Science
    • /
    • v.2 no.1
    • /
    • pp.33-46
    • /
    • 2020
  • Cosmetics are representative complex fluids, and there have been many studies focusing on the correlation between the rheological properties and sensory attributes. Various instrumental measurements have been suggested to evaluate the sensory attributes, and one of the most common instruments is Texture Analyzer (TA). Although it is reported that the adhesiveness measured by TA is related to the stickiness of cosmetics, there exists reproducibility problem because measurements with TA are sensitive to application conditions. In this study, an instrumental protocol using rotational rheometer has been set up to measure the stickiness of cosmetics. This protocol consists of two steps. The first step is a preconditioning step, and various types of shear deformations are applied to the samples. The next step is the extensional flow and the axial force is measured. When the amplitude of the shear flow corresponded to the linear viscoelastic region, the axial force is the same as those without preconditioning. On the other hand, an axial force decreases as variation nonlinearity increases. It is because the effects of microstructure changes caused by nonlinear deformation affects the extensional flow. It is worth noting that a new protocol facilitates to evaluate the stickiness of cosmetics in a more systematic way.

A Study on the Development of a Infusion Pump based on an Active Muscle Pump (능동형 근육펌프 구조의 수액 주입 펌프 개발에 관한 연구)

  • Lee, Jeong-Whan;Lee, Sang-Yeob;Lee, Jung-Eun;Ahn, Ihn-Seok
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.3
    • /
    • pp.443-449
    • /
    • 2022
  • In this study, in order to improve the disadvantages of the environmental error of the infusion set that performs infusion therapy in the existing clinical practice and to maximize the user's convenience by miniaturizing the existing infusion pump system, the structure of the muscle pump of the human vein was imitated. As a double check valve method, a method for preventing the backflow of fluid and discharging a constant fluid in one direction by external pressure was proposed. The proposed bio-mimic muscle pump uses a check valve that controls the flow of fluid in one direction and a silicone tube with elasticity, and a chamber is constructed. A peristaltic pump for applying intermittent pressure to the tube chamber was constructed using a multi-cam structure roller. In order to verify the performance of the proposed pump, optimization was performed while changing the number of multi-cam rollers and adjusting the speed of the roller driving motor, and the reproducibility of the instantaneous discharge amount and the continuous discharge amount of the pump was compared and tested. The performance of the muscle pump proposed in this study was verified through experiments that it can inject up to 1L of fluid within 12 hours, and that it is possible to inject the fluid with an accuracy of ±0.1ml. Real-time monitoring of the fluid injection volume through the bio-mimic muscle pump proposed in this study not only increases the convenience of the administrator, but also provides a precise fluid administration environment to more patients at a low cost, and additionally applies bubble detection and occlusion detection technology If so, it is believed that a safer medical environment can be provided to patients.

Reproducibility of Reaeration in Sewer using Batch Reactor Test (실험반응조를 이용한 하수관에서의 재포기현상 재현 가능성에 관한 연구)

  • Hwang, Hwankook;Min, Sangyun;Cho, Jinkyu
    • Journal of the Korean GEO-environmental Society
    • /
    • v.15 no.8
    • /
    • pp.45-50
    • /
    • 2014
  • The microorganism decomposition experiment of sewage in the underground sewer has the limit of experiment condition and time. The way to reproduce the microorganism decomposition in the underground sewer was studied using batch reactor setting up the DO as a limiting condition. The DO concentration in the sewer is controlled by reaeration. It is possible to obtain correlation between flow condition and reaeration coefficient through the reproduction of reaeration phenomenon by controlling the flow condition in the sewer using this phenomenon. And it is possible to set the flow condition and agitation intensity (velocity gradient) that has the same reaeration coefficient using the correlation between the reaeration coefficient with the flow condition and reaeration coefficient with the agitation intensity. The circumstances in the sewer system was reproduced using batch reactor setting up the DO as a limiting condition from these results.