• Title/Summary/Keyword: set-connected

Search Result 729, Processing Time 0.023 seconds

A Flexible Mobile-Geofence to support Connected-Cars Technology (커넥티드 카 기술을 지원하는 가변적 모바일 지오펜스)

  • Eom, Young-Hyun;Choi, Young-Keun;Yoo, HyunMi;Cho, Sungkuk;Jeon, Byungkook
    • Smart Media Journal
    • /
    • v.6 no.3
    • /
    • pp.89-94
    • /
    • 2017
  • The existing geofences provide only context-awareness service for entering or leaving the set region when a user sets a virtual region for his/her PoI(Point of Interest). Applying the mobile-geofence technology to the connected car technology, which is attracting attention as a next generation technology, it is possible to provide application service without additional infrastructure construction cost However, to do this, we need to expand and improve the functions of traditional geofence. In this paper, we propose and implement a flexible mobile-geofence in which the radii of each geofence applied to vehicles is changed according to context-aware in order to support connected cars technology based on the previously studied mobile three-dimensional geofence system. The proposed flexible mobile-geofence shows experimentally that the region of the geofence is changed according to context-aware of itself and its surroundings after applying a flexible decision algorithm by the flexible factor analysis. In the future, we are expected that the flexible mobile-geofence proposed in this paper will be applied not only to connected-cars technology but also to the application technology of V2X(Vehicle to Everything) for safe and efficient vehicle operation.

A study on application of eco-friendly follow-up process connected with livestock wastewater treatment plant using the upflow constructed wetland (가축분뇨처리시설과 연계한 상향류식 인공습지의 자연형 후속처리공정 적용방안에 관한 연구)

  • Choi, Hanna;Cho, Eunha;Kang, Hogeun;Park, Joohyun;Kang, Seonhong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.3
    • /
    • pp.359-370
    • /
    • 2015
  • This study developed an up-flow wetland providing either an eco-friendly follow-up process of medium-sized public treatment facility for livestock manure or a non-point source pollution controller near livestock farms. The four bench-scale up-flow wetlands were operated with four different bed media sets. The removal efficiencies of the wetland effluent for CODCr, TN, TP, SS were 35.2 %, 29.5 %, 31.2 % and 52.2 % for set 1(Blank, without reed, with bio-ceramic), 40.6 %, 43.4 %, 42.2 % and 55.4 % for set 2(with bio-reed & without bio-ceramic), 45.2 %, 48.7 %, 46.6 % and 66.3 % for set 3(with bio-reed & bio-ceramic), 32.9 %, 27.3 %, 29.3 % and 54.1 % for Set 4(with reed & bio ceramic), respectively. The set 3 condition having a mixture of bio-reed and bio-ceramic showed the highest efficiency in the bench-scale evaluation. This study suggests a mixture of bio-reed and bio-ceramic as suitable bed media in the construction of artificial wetlands near livestock farms. Soils including the bed media were monitored during the evaluation for trace elements. Soil analysis results were satisfied with the Korean Soil Contamination Standard. This study showed that the up-flow constructed wetland was feasible to treat the effluent livestock wastewater treatment facility.

Maximum Degree Vertex Domatic Set Algorithm for Domatic Number Problem (도메틱 수 문제에 관한 최대차수 정점 지배집합 알고리즘)

  • Lee, Sang-Un
    • Journal of the Korea Society of Computer and Information
    • /
    • v.20 no.2
    • /
    • pp.63-70
    • /
    • 2015
  • In the absence of a polynomial time algorithm capable of obtaining the exact solutions to it, the domatic number problem (DNP) of dominating set (DS) has been regarded as NP-complete. This paper suggests polynomial-time complexity algorithm about DNP. In this paper, I select a vertex $v_i$ of the maximum degree ${\Delta}(G)$ as an element of a dominating set $D_i,i=1,2,{\cdots},k$, compute $D_{i+1}$ from a simplified graph of $V_{i+1}=V_i{\backslash}D_i$, and verify that $D_i$ is indeed a dominating set through $V{\backslash}D_i=N_G(D_i)$. When applied to 15 various graphs, the proposed algorithm has succeeded in bringing about exact solutions with polynomial-time complexity O(kn). Therefore, the proposed domatic number algorithm shows that the domatic number problem is in fact a P-problem.

PHLIS-Based Characteristics Analysis of a 2 MW Class Tidal Current Power Generation System (PHILS 기반 2 MW급 조류발전시스템 특성 분석)

  • Go, Byeong Soo;Sung, Hae Jin;Park, Minwon;Yu, In Keun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.31 no.8
    • /
    • pp.665-670
    • /
    • 2014
  • In this paper, characteristics of a tidal current power generation system are analysis using power hardware-in-the-loop simulation (PHILS). A 10 kW motor generator set is connected to the real grid through a fabricated 10 kW back to back converter. A power control scheme is applied to the back to back converter. A 2 MW class tidal current turbine is modeled in real time digital simulator (RTDS). Generating voltage and current from the 10 kW PMSG is applied to a 2 MW class tidal current turbine in the RTDS using PHILS. The PHILS results depict the rotation speed, power coefficient, pitch angle, tip-speed ratio, and output power of tidal current turbine. The PHILS results in this paper can contribute to the increasing reliability and stability of the tidal current turbines connected to the grid using PHILS.

Cycle Embedding of Faulty Recursive Circulants (고장난 재귀원형군의 사이클 임베딩)

  • 박정흠
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.31 no.1_2
    • /
    • pp.86-94
    • /
    • 2004
  • In this paper, we show that $ G(2^m, 4), m{\geq}3$with at most m-2 faulty elements has a fault-free cycle of length 1 for every ${\leq}1{\leq}2^m-f_v$ is the number of faulty vertices. To achieve our purpose, we define a graph G to be k-fault hypohamiltonian-connected if for any set F of faulty elements, G- F has a fault-free path joining every pair of fault-free vertices whose length is shorter than a hamiltonian path by one, and then show that$ G(2^m, 4), m{\geq}3$ is m-3-fault hypohamiltonian-connected.

Selection of Connection Position to Change Dynamic Characteristic of Structure (동특성 변경을 위한 구조물의 결합 위치 선정)

  • Kim, Kyung-Won;Park, Youn-Sik;Kim, Sung-Hoon;Kim, Jin-Hee;Rhee, Ju-Hun;Hwang, Do-Soon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.13 no.12
    • /
    • pp.930-937
    • /
    • 2003
  • This research deals with how to select connection positions of two substructures to be synthesized. The goal of this research is to find optimal connection positions in order to maximize the fundamental natural frequency of the synthesized structure. The natural frequencies of a connected structure are obtained by modal-force equations. Optimal connection positions can be selected through optimization process. In the optimization process, the natural frequencies of a connected structure are set to object function value and connection positions become design variables. The method described above is applied to synthesis problems of plates, which is initially conducted for FE models and verified through experiments. Especially in experiments. FRF(frequency response function) s are obtained by means of the Modal Testing technique to be used in modal-force equations for synthesizing. Once the substructures are synthesized. the Modal Testing technique is again applied to spot-welded structure using the result from the optimization procedure. It is found that the fundamental natural frequency of the synthesized structure with the optimized result gives higher value than those with the initially given connection positions.

Experiment for the Relation Between Arrangement,Numbers and Pumping Rates of Well (관정의 배열수 및 양수량의 상호관계에 관한 실험)

  • 권무남
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.11 no.3
    • /
    • pp.1707-1718
    • /
    • 1969
  • The purpose of this experiment is to determine the relations between numbers, arrangements and pumping rates of wells. In this experiment, well pipes were vertically set up in an artificial water-bearing sand layer of homogeneous quality. Wells were arranged in different ways and their number was varied in order to observe the variation of pumping rates. Sands were filled in a square tank, $183cm{\times}91.5cm{\times}91.5cm$ so as to secure a water-bearing layer. Water was constantly supplied from a supply tank located at an end of the tank. The number of well pipes was varied from one to four. Well pipes were connected by a horizontal header pipes were connected by a horizontal header pipe located above them and one pump was used. Pumping rates were measured, when they were arranged in longitudinal and lateral directions, They were also arranged in a square and triangle. The main results thus obtained are presented as follows: (1) When well pipes are laid out in a longitudinal line, i. e., in a flow direction, the ratios of pumping rates of one-pipe well and wells 2-, 3- and 4- pipe t, are 1.903, 2.506 and 2.66, respectively. (2) When well pipes are laid out in a lateral line, i.e., in a perpendicular direction to flow, the same ratios as (1) are 1.912, 2.527 and 2.88. (3) When four pipes are laid out in a square and three pipes are laid out in a triangle, pumping rates are deereased, Comparing with the cases when pipes are laid out in a straight line.

  • PDF

Impulse Response Characteristics of the Grounding Systems with respect to the Common-Connection Position in Power Utility System (수변전설비에서 접지시스템의 공결점의 위치에 따른 임펄스 응답특성)

  • Lee, B.H.;Eom, J.H.;Kim, S.W.;Shim, P.S.;Lee, S.C.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2149-2151
    • /
    • 1999
  • This paper describes the impulse response characteristics of the grounding systems in power utility system. Several regulations regarding to electric power equipments, services and managements require that the groundings of class 1 ($E_1$) and class 2 ($E_2$) must be connected at the common point in grounding systems. In addition, the grounding for arrester ($E_{LA}$), which belongs to the grounding of class 1, should be connected at the same point. However, there is no method and position of common-connection at anywhere. In this work, when the impulse current was injected through the grounding conductor for arrester, the investigations measuring and analyzing potential rises induced at the common connection point and other grounding conductors were conducted. The experiments were carried out in the conditions of the grounding conductor of 25m long and the near or remote common connection from ground electrode. The lightning impulse current was applied so as to simulate the on-set of arrester due to lightning and/or switching surges.

  • PDF

A study on Design and Efficient Management of 30kW BIPV System (건물통합형 30kW태양광발전시스템의 설계 및 효율적 운전관리에 관한 연구)

  • Park, Se-Joon;Lim, Jung-Yeol;Yoon, Seok-Am;Cha, In-Su
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.3
    • /
    • pp.15-20
    • /
    • 2008
  • Building-integrated photovoltaics(BIPV) are increasingly incorporated into new domestic and industrial buildings as a principal or ancillary source of electrical power, and are one of the fastest growing segments of the photovoltaic industry. This paper presents design, operational features analysis, and PCS(Power Conditioning System) of grid-connected 30kW BIPV set up on the library of Dongshin University. For a sustainable photovoltaics system in this area, the data of the BIPV system are collected and analyzed by monitoring system using LabView. PCS of the grid-connected BIPV system, also, is designed for optimal operation with characteristics suggested in this paper.

Selection of Connection Position to Change Dynamic Characteristic of Structure (동특성 변경을 위한 구조물의 결합 위치 선정)

  • 김경원;박윤식;박영진
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.65-71
    • /
    • 2003
  • This research deals with how to select connection positions of two substructures to be synthesized. The goal of this research is to find optimal connection positions in order to maximize the fundamental natural frequency of the synthesized structure. The natural frequencies of a connected structure are obtained by modal-force equations. Optimal connection positions can be selected through optimization process. In the optimization process, the natural frequencies of a connected structure are set to object function value and connection positions become design variables. The method described above is applied to synthesis problems of plates, which is initially conducted for FE models and verified through experiments. Especially in experiments, FRE(frequency Response function)s are obtained by means of the Modal Testing technique to be used in modal-force equations for synthesizing. Once the substructures are synthesized, the Modal Testing technique is again applied to spot-welded structure using the result from the optimization procedure. It is found that the fundamental natural frequency of the synthesized structure with the optimized result gives higher value than those with the initially given connection positions.

  • PDF