• Title/Summary/Keyword: serial communication protocol

Search Result 128, Processing Time 0.025 seconds

A study of multi protocol communication on single serial interface (Serial 전송라인에서 Multi-Protocol 통신의 구현 연구)

  • Lee, Jae-Cheol;Ko, Dae-Sik
    • Journal of Advanced Navigation Technology
    • /
    • v.12 no.5
    • /
    • pp.464-469
    • /
    • 2008
  • The RS-232C (Unbalanced serial) and RS-485 (balanced serial) are standard in serial communication. RS-485 uses a differential electrical signal, as opposed to unbalanced signals referenced to ground with the RS-232. Differential transmission, which uses two lines each for transmit and receive signal results in greater noise immunity and longer distances as compared to the RS-232C. The greater noise immunity and distance are big advantages in industrial environments. In general, one protocol on one serial interface is very normal application. In this study, we implemented multi protocols on one serial RS-485 interface and examine the performance and result with hanging multi equipments.

  • PDF

A Study on the design and implementation of serial communication using only one pin (단일 핀을 이용한 직렬 통신 설계 및 구현에 관한 연구)

  • Park, Sang-Bong;Heo, Jeong-Hwa
    • The Journal of the Convergence on Culture Technology
    • /
    • v.1 no.3
    • /
    • pp.83-85
    • /
    • 2015
  • It has been increased that communicate each other things such as consumer electronics, mobile equipments and wearable computer with serial communication protocol. The conventional method of SPI and I2C high speed serial communication is widely used with 2 pin of clock and data pin. It has been more important than the speed of data transfer to simplify the hardware structure because the IoT components is reduced the hardware complexity. In this paper, we describe the protocol and implementation of serial data transfer with only one pin. The proposed protocol is suitable for the mobile products that send and receive the small amount of data with low speed and low power consumption.

Implementation of RS232C Serial Communication by CSMA protocol (충돌검지 다중접속(CSMA) 프로토콜에 의한 RS232C 직렬통신의 구현)

  • Kwak, Hee-Soo;Han, Kyong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1998.07g
    • /
    • pp.2473-2475
    • /
    • 1998
  • In this paper, we implemented RS232C serial communication by the 2 wires(Data,GND), and multiple access, by the applying Collision Sensing Multiple Access(CSMA) Protocol. Multiple access is implemented by assigning a unique ID to each controller. The multiple access control operation starts by sending a command packet from a host to another host and the command packet is composed of ID bytes of source and target host computer, data bytes and the check sum, byte. In host computer, after sending command packet, the collision from loop back data. If collision is detected, it means a command packet was collided with another command packet for another host. The packet communication of the controller enables the multiple acces of the controller through the common serial data link. The application of this serial communication through CSMA protocol and the usage of two wires, have an effect on saving the wires and convenient of layout work.

  • PDF

A Study on The Improvement of Multidisplinary Structure Technique of Ethrnet Network based of PC Serial Communication (PC 시리얼통신 기반의 이더넷 네트워크 융복합 구성 기술 성능 향상에 관한 연구)

  • Jin, Hyun-Soo
    • Journal of Digital Convergence
    • /
    • v.13 no.10
    • /
    • pp.263-269
    • /
    • 2015
  • This paper suggest remote control technic using TCP/IP protocol network after UART serial communication implemented through RS-232 cable to ethernet module. This is multidisplinary signal technique which is PC signal is converted to internet communication signal. Ethernet module is WIZ1000SR. This is gate module which convert RS-232 protocol to TCP/IP protocol. This module convert serial data transmitted serial device to TCP/IP type data, in contrast TCP/IP data received through network converted to serial data transmitted to serial device. This paper propose that the lower subnet internet layer UDP module make the higher speed in control board than TCP/IP signal.

Performance Comparison of Mobile Ad Hoc Multicast Routing Protocols (모바일 애드 혹 멀티캐스트 라우팅 프로토콜 성능분석)

  • Lee, Joo-Han;Cho, Jin-Woong;Lee, Jang-Yeon;Lee, Hyeon-Seok;Park, Sung-Kwon
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.8 no.5
    • /
    • pp.173-179
    • /
    • 2008
  • An ad hoc network is multi-hop wireledss formed by mobile node without infrastructure. Due to the mobility of nodes in mobile ad hoc networks, the topology of network changes frequently. In this environments, multicast protocols are faced with the challenge of producing multi-hop routes and limitation of bandwidth. We compare the performance of two multicast routing protocols for mobile ad hoc networks - Serial Multiple Disjoint Tree Multicast Routing Protocol (Serial MDTMR) and Adaptive Core Multicast Routing Protocol (ACMRP). The simulator is implemented with GloMoSim.

  • PDF

Design and Implementation of Wireless Lighting LED Controller using Modbus TCP for a Ship (Modbus TCP를 이용한 선박용 무선 LED 제어기의 설계 및 구현)

  • Jeong, Jeong-Soo;Lee, Sang-Bae
    • Journal of Navigation and Port Research
    • /
    • v.41 no.6
    • /
    • pp.395-400
    • /
    • 2017
  • As a serial communications protocol, Modbus has become a practically standard communication protocol and is now a commonly available means of connecting industrial electronic devices. Therefore, all devices can be connected using the Modbus protocol with the measurement and remote control on ships, buildings, trains, airplanes and more. The existing Modbus that has been used is based on serial communication. Modbus TCP uses Ethernet communication based on TCP / IP which is the most widely used Internet protocol today; so, it is faster than serial communication and can be connected to the Internet of Things. In this paper, we designed an algorithm to control LED lighting in a wireless Wi-Fi environment using the Modbus TCP communication protocol, and designed and implemented a LED controller circuit that can check external environmental factors and control remotely through the integrated management system of a ship. Temperature, humidity, current and illuminance values, which are external environmental factors, are received by the controller through the sensors, and these values are communicated to the ship's integrated management system via the Modbus protocol. The Modbus can be connected to Master devices via TCP communication to monitor temperature, humidity, current, illuminance status and LED output values, and also users can change the RGB value remotely in order to change to the desired color. In addition, in order to confirm the implementation of the controller, we developed a simulated ship management system to monitor the temperature, humidity, current and illumination conditions, and change the LED color of the controller by changing the RGB value remotely.

[Retracted]Cyber Threat Analysis on Network Communication in Power System and Countermeasures Suggestions ([논문철회]전력계통 네트워크 통신방식 변화에 따른 사이버위협 분석 및 대응방안 제시)

  • Il Hwan Ji;Seungho Jeon;Jung Taek Seo
    • Smart Media Journal
    • /
    • v.12 no.2
    • /
    • pp.91-102
    • /
    • 2023
  • The Energy Management System (EMS) communicates with power plants and substations, monitors the substations and plant operational status of the transmission and substation system for stability, continuity, real-time, and economy of power supply, and controls power plants and substations. Currently, the power exchange EMS communicates with power plants and substations based on the serial communication-based Distributed Network Protocol (DNP) 3.0 protocol. However, problems such as the difficulty of supply and demand of serial communication equipment and the lack of installation space for serial ports and modems are raised due to the continuous increase in new facilities to perform communication, including renewable power generation facilities. Therefore, this paper presents a TCP/IP-based communication method instead of the existing serial communication method of the power exchange EMS, and presents a security risk analysis that may occur due to changes in the communication method and a countermeasure to the security risk.

Serial Communication-Based Fault Diagnosis of a BLDC Motor Using Bayes Classifier

  • Suh, Suhk-Hoon;Woo, Kwang-Joon
    • International Journal of Control, Automation, and Systems
    • /
    • v.1 no.3
    • /
    • pp.308-314
    • /
    • 2003
  • This paper presents a serial communication based fault diagnosis scheme for a brushless DC (BLDC) motor using parameter estimation and Bayes classifier. The presented scheme consists of a smart network board, and a fault detection and isolation (FDI) master. The smart network board is installed near the BLDC motor drive system to acquire motor data and transmit motor data to the FDI-master via serial communication channel. The FDI-master estimates BLDC motor resistance to detect symptom of faults, and assign symptom to fault type using Bayes classifier. In this scheme, since communication time delay has a serious effect on performance, periodic and fixed communication protocol is designed. Hence, the delay time is priory known. By experiment result, presented scheme was verified.

Communication Architecture of the IEC 61850-based Micro Grid System

  • Yoo, Byong-Kwan;Yang, Seung-Ho;Yang, Hyo-Sik;Kim, Won-Yong;Jeong, Yu-Seok;Han, Byung-Moon;Jang, Kwang-Soo
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.5
    • /
    • pp.605-612
    • /
    • 2011
  • As the power grids are integrated into one big umbrella called a "smart grid," communication protocol plays a key role in successful operations. The successful deployment of smart grid interoperability is a major hurdle that must be overcome. The micro grid, a small power system that distributes energy resource, is operated in diverse regions. Different vendors use different communication protocols in the operation of the micro grid. Recently, the IEC 61850 has been legislated to solve the interoperability problems in power utility automation. The present paper presents a micro grid system based on the IEC 61850 protocol. It consists of a micro grid monitoring system, a protocol converter that transforms serial data to IEC 61850 data, and distributed energy resource controllers for diverse DER nodes. A developed communication gateway can be deployed for DER controllers with serial links to exchange data with IEC 61850-based devices. The gateway can be extended to IEC 61850-based distribution automation systems, substation automation systems, or SCADA.

Implementation and design of fuse controller using single wire serial communication (단일 입력 직렬 통신을 이용한 퓨즈 제어 회로설계 및 구현)

  • Park, Sang-bong;Heo, Jeong-hwa
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.6
    • /
    • pp.251-255
    • /
    • 2015
  • In this paper, we propose a fuse controller which is used for storing the optimal value or the correction value for the surrounding product of the IoT applications and it is implemented serial communication circuit using a single pin. Because of the proposed single pin protocol is simpler in the hardware than the conventional $I^2C$ and SPI using two or more pins, it is suitable for the area of small amount of data transmission. The function of the one pin protocol is verified by logic simulation and the FPGA test board and it is fabricated using CMOS 0.35um technology. It is expected to use the IoT product that require the low power consumption and simple hardware.