• Title/Summary/Keyword: sensor signal level

Search Result 264, Processing Time 0.029 seconds

Design of FMCW radar waveform for flow measurement (유량 측정을 위한 FMCW 레이다 파형 설계)

  • Lee, Changki
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.1
    • /
    • pp.83-90
    • /
    • 2020
  • A commercial flow measurement radar sensor estimates a quantity of flowed water using surface flow rate. In this way, the amount of water flowing per unit time cannot be measured accurately because of using an estimation result and it can't response environmental changes. For more accurate flow measurements we need width of waterway, water level and distance that water moved per unit time. Commonly two sensors are used to measure water level and flow rate. In this paper, we propose a method to simultaneously measure the water level and surface flow velocity using a single FMCW radar sensor and design the transmission waveform. In order to verify the waveform design, received signal is modelled based on transmission waveform. In addition, we consider phenomenons and problems that may occur in signal processing.

Interference of Sulphur Dioxide on Balloon-borne Electrochemical Concentration Cell Ozone Sensors over the Mexico City Metropolitan Area

  • Kanda, Isao;Basaldud, Roberto;Horikoshi, Nobuji;Okazaki, Yukiyo;Benitez-Garcia, Sandy-Edith;Ortinez, Abraham;Benitez, Victor Ramos;Cardenas, Beatriz;Wakamatsu, Shinji
    • Asian Journal of Atmospheric Environment
    • /
    • v.8 no.3
    • /
    • pp.162-174
    • /
    • 2014
  • An abnormal decrease in ozonesonde sensor signal occurred during air-pollution study campaigns in November 2011 and March 2012 in Mexico City Metropolitan Area (MCMA). Sharp drops in sensor signal around 5 km above sea level and above were observed in November 2011, and a reduction of signal over a broad range of altitude was observed in the convective boundary layer in March 2012. Circumstantial evidence indicated that $SO_2$ gas interfered with the electrochemical concentration cell (ECC) ozone sensors in the ozonesonde and that this interference was the cause of the reduced sensor signal output. The sharp drops in November 2011 were attributed to the $SO_2$ plume from Popocat$\acute{e}$petl volcano southeast of MCMA. Experiments on the response of the ECC sensor to representative atmospheric trace gases showed that only $SO_2$ could cause the observed abrupt drops in sensor signal. The vertical profile of the plume reproduced by a Lagrangian particle diffusion simulation supported this finding. A near-ground reduction in the sensor signal in March 2012 was attributed to an $SO_2$ plume from the Tula industrial complex north-west of MCMA. Before and at the time of ozonesonde launch, intermittent high $SO_2$ concentrations were recorded at ground-level monitoring stations north of MCMA. The difference between the $O_3$ concentration measured by the ozonesonde and that recorded by a UV-based $O_3$ monitor was consistent with the $SO_2$ concentration recorded by a UV-based monitor on the ground. The vertical profiles of the plumes estimated by Lagrangian particle diffusion simulation agreed fairly well with the observed profile. Statistical analysis of the wind field in MCMA revealed that the effect Popocat$\acute{e}$petl was most likely to have occurred from June to October, whereas the effect of the industries north of MCMA, including the Tula complex, was predicted to occur throughout the year.

Develoment of high-sensitivity wireless strain sensor for structural health monitoring

  • Jo, Hongki;Park, Jong-Woong;Spencer, B.F. Jr.;Jung, Hyung-Jo
    • Smart Structures and Systems
    • /
    • v.11 no.5
    • /
    • pp.477-496
    • /
    • 2013
  • Due to their cost-effectiveness and ease of installation, wireless smart sensors (WSS) have received considerable recent attention for structural health monitoring of civil infrastructure. Though various wireless smart sensor networks (WSSN) have been successfully implemented for full-scale structural health monitoring (SHM) applications, monitoring of low-level ambient strain still remains a challenging problem for WSS due to A/D converter (ADC) resolution, inherent circuit noise, and the need for automatic operation. In this paper, the design and validation of high-precision strain sensor board for the Imote2 WSS platform and its application to SHM of a cable-stayed bridge are presented. By accurate and automated balancing of the Wheatstone bridge, signal amplification of up to 2507-times can be obtained, while keeping signal mean close to the center of the ADC span, which allows utilization of the full span of the ADC. For better applicability to SHM for real-world structures, temperature compensation and shunt calibration are also implemented. Moreover, the sensor board has been designed to accommodate a friction-type magnet strain sensor, in addition to traditional foil-type strain gages, facilitating fast and easy deployment. The wireless strain sensor board performance is verified through both laboratory-scale tests and deployment on a full-scale cable-stayed bridge.

Variation Factor Assessment of Radial Artery Pulse by the Tonometry Angle of the Pulse Pressure Sensor (토노메트리 방식 맥파 측정의 가압 각도에 따른 변동성 평가)

  • Jung, Chang Jin;Jo, Jung Hee;Jun, Min-Ho;Jeon, Young Ju;Kim, Young-Min
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.2
    • /
    • pp.138-142
    • /
    • 2016
  • A pulse measurement by tonometry provides useful information for diagnosis, including not only blood pressure and heart rate but also parameters for estimating a condition of the cardiovascular system. Currently, various pulse measurement devices based on the tonometry have been developed. A reliability of these devices is determined by a positioning technic between the sensor and the blood vessel and a controlling technique of the pressurization level. An angle of the sensor for the pulse measurement seems to be highly related with a measured signal, however, the objective studies for this issue have been not published. In this paper, the variation of the pulse signals by tonometry direction was experimentally assessed according to the angle of the sensor. In order for guaranteeing the repeatability of the experiment, we used a pulse generator device, which can generate human pulse signal by using silicon tube and fluid pump, and developed a structure for precise adjustment of the angle and the pressurization level of the sensor. The angle of the sensor was acquired by an inclinometer, which was attached at the opposite side of the sensor. As results, a coefficient of variation (CV) of a maximum amplitude (MA) of the pulse wave was largely increased over the angle range of $-9{\sim}9^{\circ}$. Furthermore, the changes of the pulse shape showed different aspects according to the sign of the angle tilted along the blood vessel. It is expected that the results of this study can be helpful for developing more precise pulse measurement devices based on the tonometry and applying in clinic.

Flicker-free Visible Light Communication Using Three-level RZ Modulation

  • Lee, Seong-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.29 no.2
    • /
    • pp.75-81
    • /
    • 2020
  • We introduce a new visible light communication (VLC) method in which three-level return-to-zero (RZ) modulation is used for flicker-free transmission. In the VLC transmitter, the three-level RZ modulation ensures that the average optical power is constant; thus, a flicker-free light-emitting diode (LED) light is achieved. In the VLC receiver, a resistor-capacitor high-pass filter is used for generating spike signals, which are used for data recovery while eliminating the 120 Hz optical noise from adjacent lighting lamps. In transmission experiments, we applied this method for wireless transmission of an air quality sensor message using the visible light of an LED array. This configuration is useful for the construction of indoor wireless sensor networks for air pollution monitoring using LED lights.

Implementation of an Integrated Pressure-sensor System Adapted to the Optimum Sensitivity

  • Hong, Sung-Hee;Cho, Chun-Hyung
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.17 no.2
    • /
    • pp.186-191
    • /
    • 2017
  • An integrated pressure-sensor system was developed using the sensor-conditioning processes, which resulted in the optimum sensitivity of the pressure-sensor through the signal amplification, noise reduction, and level shift. Due to the specified characteristics among the components, such as operation range, the sensor output was generally limited compared to the full scale of the reading when coupled with other parts. Devices fabricated exhibited comparable characteristics with higher pressure sensitivity to that of the pressure sensor without sensor-conditioning process. In this work, the sensor resolution was at least enhanced at least by 25% using the sensor-conditioning processes.

A study on Non-contacted Transmitter Switch for Vehicle (비 접촉식 차량용 Transmitter Switch에 관한 연구)

  • Ahn, Jong-Young;Kim, Young-Sub;Kim, Sung-Su;Hur, Kang-In
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.10 no.5
    • /
    • pp.245-249
    • /
    • 2010
  • Now normally using a contact method of vehicle Inhibitor Switch that is use direct voltage level signal. This method is good solution for signal deliverly. but The contacted method have a short lifetime because of deterioration of contact surface. so we suggest to non-contacted method using magnetic sensor. The magnetic sensor is used to non-contacted method that is solution for problem of contacted method. In this paper using that of magnetic sensor feature, so we applied to Vehicle Transmitter switch that of non-contacting method. Sensor voltage outputs have variable electric potential that normally 0 mV to 150 mV, and it is depend on Switch Angle. we used two differential sin wave for switching of 5 state signal.

Sound System Analysis for Health Smart Home

  • CASTELLI Eric;ISTRATE Dan;NGUYEN Cong-Phuong
    • Proceedings of the IEEK Conference
    • /
    • summer
    • /
    • pp.237-243
    • /
    • 2004
  • A multichannel smart sound sensor capable to detect and identify sound events in noisy conditions is presented in this paper. Sound information extraction is a complex task and the main difficulty consists is the extraction of high­level information from an one-dimensional signal. The input of smart sound sensor is composed of data collected by 5 microphones and its output data is sent through a network. For a real time working purpose, the sound analysis is divided in three steps: sound event detection for each sound channel, fusion between simultaneously events and sound identification. The event detection module find impulsive signals in the noise and extracts them from the signal flow. Our smart sensor must be capable to identify impulsive signals but also speech presence too, in a noisy environment. The classification module is launched in a parallel task on the channel chosen by data fusion process. It looks to identify the event sound between seven predefined sound classes and uses a Gaussian Mixture Model (GMM) method. Mel Frequency Cepstral Coefficients are used in combination with new ones like zero crossing rate, centroid and roll-off point. This smart sound sensor is a part of a medical telemonitoring project with the aim of detecting serious accidents.

  • PDF

An Improvement of Performance in a Satellite Antenna Tracking Control System for Mobile DAB Reception (DAB수신을 위한 이동체용 위성 안테나 트랙킹 시스템의 성능 개선)

  • Jeong Joong-Sung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.7
    • /
    • pp.1178-1184
    • /
    • 2004
  • This paper presents the development of a satellite antenna tracking control system using a plane antenna for mobile DAB(Digital Audio Broadcasting) reception. To track more rapidly in the antenna of this system, this simple tracking system only tracks a direction of azimuth using pendulum in the direction of elevation. This system should track using the AGC(Automatic Gain Control) of the signal level which can receive DAB in spite of the changing of point and movement of the mobile. The directional gyro sensor is attached to solve the delay time in the Proposed tracking algorithm. The effectiveness of both the stabilization and tracking algorithm is demonstrated through experiment measuring AGC signal level. The implemented satellite antenna tracking control system is shown to be excellent for mobile DAB reception.

An Implementation of ISP for CMOS Image Sensor (CMOS 카메라 이미지 센서용 ISP 구현)

  • Sonh, Seung-Il;Lee, Dong-Hoon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.3
    • /
    • pp.555-562
    • /
    • 2007
  • In order to display Bayer input stream received from CMOS image sensor to the display device, image signal processing must be performed. That is, the hardware performing the image signal processing for Bayer data is called ISP(Image Signal Processor). We can see real image through ISP processing. ISP executes functionalities for gamma correction, interpolation, color space conversion, image effect, image scale, AWB, AE and AF. In this paper, we obtained the optimum algorithm through software verification of ISP module for CMOS camera image sensor and described using VHDL and verified in ModelSim6.0a simulator. Also we downloaded into Xilinx XCV-1000e for the designed ISP module and completed the board level verification using PCI interface.