• Title/Summary/Keyword: self-Inspection

Search Result 272, Processing Time 0.026 seconds

A study of the system that enables real-time contact confirmation of probes in OLED panel inspection (OLED Panel 검사 시에 Probe의 실시간 Contact 확인 가능한 시스템에 관한 연구)

  • Hwang, Mi-Sub;Han, Bong-Seok;Han, Yu-Jin;Choi, Doo-Sun;Kim, Tae-Min;Park, Kyu-Bag;Lee, Jeong-woo;Kim, Ji-Hun
    • Design & Manufacturing
    • /
    • v.14 no.2
    • /
    • pp.21-27
    • /
    • 2020
  • Recently, LCD (Liquid Crystal Display) has been replaced by OLDE (Organic Light Emitting Diode) in high resolution display industry. In the process of OLDE production, it inspects defective products by sending a signal using a probe during OLED panel inspection. At this time, the cause of the detection of failure is divided into two. One is the self-defect of the OLED panel and the other is the poor contact occurring in the process of contact between the two. The second case is unknown at the time of testing, which increases the time for retesting. To this end, we made a system that can identify in real time whether the probe is in contact during the inspection. A contact probe unit was designed for the system, and a stage system was implemented. An inspection system was constructed through S / W and circuit configuration for actual inspection. Finally, a system that can check contact and non-contact in real time was constructed.

A study on Translation-, Magnification- and Rotation- Invariant automatic Inspection System Development (이동, 배율, 회전에 무관한 자동 검사 장치 개발에 관한 연구)

  • O, Chun-Seok;Im, Jong-Seol
    • The Transactions of the Korea Information Processing Society
    • /
    • v.6 no.4
    • /
    • pp.1136-1142
    • /
    • 1999
  • A difficulty of the visual inspection for translated, magnified and rotated objects exists owing to the limitation of recognition rate. In this paper, we perform to define Integral Logarithm Transform(ILT), to consider its characteristic for implementation of Translation-, Magnification- and Rotation-invariant inspection system, and to compare with other methods in inspection error rate. By using magnification and rotation invariance properties of ILT, it makes easier than other methods to extract the rotation degree. The new method employs the ILT for the good/bad inspection of translated, magnified and rotated objects and experiment is performed to achieve translation, magnification and rotation invariance. In other methods both magnification and rotation invariance can't be available. As the result of he experiment, it is not better than the self-organizing map in the improvement of recognition rate, but it shows us the possibility to be used as a tool for the good/bad inspection system.

  • PDF

Defect Length Estimation Using SQI for Underground Gas Pipelines (SQI를 이용한 지하 매설 가스 배관 결함 길이 추정)

  • Kim, Min-Ho;Choi, Doo-Hyun
    • Journal of the Korean Institute of Gas
    • /
    • v.15 no.2
    • /
    • pp.27-32
    • /
    • 2011
  • In this paper a new defect length estimation algorithm using SQI(self quotient image) is presented for the MFL(magnetic flux leakage) inspection of underground gas pipelines. Gas pipelines are magnetized by the permanent magnets of the MFL PIG(pipeline inspection gauge) when the PIG runs through pipelines. If defects or corrosions exist in the pipeline, magnetic leakage flux is increased. The MFL signals measured by hall sensors are analyzed to estimate defect length using SQI. For 74 real defects carved in KOGAS pipeline simulation facility(KPSF) the accuracy of defect length estimation of the proposed algorithm was compared with that of conventional methods.

A Study on the Development of Self-Checklists for Small and Medium-Sized Chemical Industries (중소규모 화학업종을 위한 자율점검표 개발 연구)

  • Woo Sub Shim;Kyeong-Seok Oh
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.5
    • /
    • pp.757-763
    • /
    • 2023
  • Major industrial accidents in which workers die due to fires or explosions while working at chemical substance handling workplaces continue to occur. Among the major industrial accidents that occurred between 2005 and 2021, the accident status by work situation and equipment was analyzed. Through analysis, it was confirmed that storage, reaction, and piping facilities were the main causes of the accident, and a self-checklist for each facility was developed. Verification was conducted through the supply and use groups to evaluate the suitability of the use, duties, and items of the self-checklist. The user group showed higher satisfaction than the supplier group for all three suitability of use, job, and item. In particular, since the inspection items of the self-checklist were organized around the cause of the accident derived through the analysis of actual accident cases, the satisfaction level was high in all groups. It is expected that the self-checklist developed through this study will be useful not only for large companies but also for small and medium-sized chemical industries that lack professional manpower.

An attitude survey on the safety of the household utilities with the urban gas (설문에 의한 도시가스 사용가구의 안전의식도 조사)

  • Ko Jae-Sun;Kim Hyo;Lee SuKyoung
    • 한국가스학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.37-43
    • /
    • 2005
  • The questionnaires about the safety of the urban gas have been carried out for the end users. about 8 of 10 persons said that the urban gas Is safe to use, whereas $35\%$ of them said there exists a hazard of an accident in thier residences. There cannot be found the clear evidences that the understandings on the safety of the urban gas have no relations to their ages, sex, and monthly incomes, while the safety is less confidential to the highly educated, the accident-experienced, or the mans who are poor at the safety inspections. Most of the questioned man know the inspection knacks for the gas utilities, but only $60\%$ of them carry out it. They said that they do not feel the necessity of the inspection because they are inspected routinely by the suppliers or the inspection companies. This says that the end user does not concern the safety inspections, and in order to improve the dependency of the user for the self-inspections, the inspection staff should educate the user for the necessity and the knack of inspections to encourage the self-inspection of the gas utilities.

  • PDF

A Study on the Daily Inspection Optimization of the Rolling Stocks (철도차량 일상검수 최적화에 관한 연구)

  • Kang, Byoung-Soo;Lee, Kang-In
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.7 no.4
    • /
    • pp.41-47
    • /
    • 2012
  • Railroad rolling stock has long service life and a lot of maintenance cost running on rail by wear and vibration. And it is very important to get optimization of maintenance. This paper want to analyze rolling stock maintenance situation of KORAIL and find out its improvement methods. Especially, the purpose of this paper is to adopt the most effective maintenance period and methods to daily inspection which needs many maintenance manpower in rolling stock. Rolling stock has self-diagnosis function using computer system and the quality of rolling stock has much improved these days but current daily inspection repeat for short period routinely and it is very ineffective. Therefore, the paper adopt improved daily inspection period reflecting the characteristics of rolling stock, and want to secure reliability of rolling stock and minimize maintenance cost.

  • PDF

Improving the Safety Regulation For Self Contained Breathing Apparatus (특정소방대상물의 공기호흡기 안전규제 개선방안)

  • Lee, Sang-Pal
    • Fire Science and Engineering
    • /
    • v.24 no.3
    • /
    • pp.45-51
    • /
    • 2010
  • The objective of this study to analyse the cause and pattern of failing to use in Self Contained Breathing Apparatus using by government regulation for producer and client. Regulation for producer is related to legal and institution of safety inspectiontest of SCBA. Rregulation for client is preventive maintenance. Improving fail in use of SCBA are following. First, expansion of ad hoc collection inspection and safety checking is required. Second, the strict application of the law for monitoring and auditing disposal procedure in low performance SCBA is required.

The Effects of Self-Healing for Ternary Blended Cement in Tap-water and Sea-water (삼성분계 시멘트의 해수와 담수에서의 자기치유 효과)

  • Kim, Tae-Wan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.6
    • /
    • pp.10-19
    • /
    • 2016
  • The objective of this study is to investigate the self-healing properties of ternary blended cement(TBC) paste made with OPC, GGBFS and FA. The influence of OPC-GGBFS-FA on the self-healing ability of ternary blended cement paste was researched by ultrasonic pulse velocity(UPV) measurement. The TBC paste with GGBFS-FA replacement ratios of 20%, 40% and 60% were prepared having a constant water-cementitious materials ratios os 0.5. The research focuses on behavior after 28days(after loading). Four-point bending tests are used to pre-cracked the prismatic specimens at 28days. For specimens (uncracked and cracked) submerged in tap-water and sea-water until 60days. According to the experimental results, the TBC paste system has self-healing ability increased when the fraction of GGBFS increased. Because GGBFS and FA continues to hydrate after 28days, it is likely that hydrated products from GGBFS and FA may modify microstructures, seal these cracks. From these results, it is clear that the crack in all samples experience self-healing and that this occurs mostly in the first 30days of submerging. Futhermore, most of the healing for both specimens of submerged in sea-water and tap-water occurred during the first 30days. Sea-water submerged specimens healed cracks as fast as those in tap-water. Differences in healing effects of submerged in sea-water and tap-water may be attributed to the presence of specific sea-water ions. Therefore, self-healing effects considered age-effects was more strong effect occurred mostly in the first 30days, and then gradually weaken.

A Study on the Production and Badness of Women's Jacket Manufacturing Companies (숙녀복(淑女服) 재킷 봉제업체(縫製業體)의 생산(生産) 및 부량(不良) 실태(實態) 연구(硏究))

  • Shim, Jae-Hee;Sohn, Hee-Soon
    • Journal of Fashion Business
    • /
    • v.5 no.4
    • /
    • pp.118-126
    • /
    • 2001
  • The purpose of this study, which is related with local women's jacket Manufacturing companies in Seoul and Kyeong-Ki areas, is for the research of general problems, badness in those companies, noticing products' quality level, and full solutions of luxurious sewing technology and high quality products. The results of this study are as follows. 1. Most women's jacket manufacturing companies are poor and producing system is on a changing trend to the pair system. 2. A wage level of inspectors are low compared with working experiences and working period is short compared with working experiences. So, the separation rate was high. 3. The inspection form is full style, but some companies are just inspecting samples or frequent check. 4. Insperation method is highly at the rate of self-inspection and head office inspection. There are inspects in their factories and companies, but some companies don't. 5. There are lots of badness styles such as shrinking of fabric, contaminating of product, dying of fabric, pressing. 6. A work standard, workers' technical education, and giving purposes to workers are demanded for avoiding of products badness.

  • PDF

A Study on the Development of Light Emotion Friendly Concrete Block for Efficient Application of Titan-oxide Photocatalyst (이산화티탄 광촉매의 효율적 적용을 위한 LEFC 블록 제작에 관한 연구)

  • Kim, Byoung-Il;Oh, Sang-Keun;Seo, Seung-Hoon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.6
    • /
    • pp.120-131
    • /
    • 2019
  • Recently, the level of fine dust and ultrafine dust has reached its highest level, threatening the public's health. If the air purifier was not operated indoors, natural ventilation would not be possible. In this study, photocatalyst is applied to building materials to purify air in a passive manner. In order to use photocatalyst for LEFC(Light Emotion Friendly Concrete), it is necessary to secure self-consolidating capability. Therefore, self-consolidating performance was evaluated by slump test, J-ring test and L-box test with UHPC materials applied. Based on these results, the mixture proportion was determined, and the mechanical performance was evaluated by compressive and flexural tests. Concrete blocks were constructed with a fabrication method that improved the existing process of making LEFC. Also, the concrete block was emptied as a way to reduce the use of expensive photocatalyst. Finally, in order to identify the distribution of TiO2, an EDS analysis was performed.