• 제목/요약/키워드: self field loss

검색결과 61건 처리시간 0.02초

전력기기에서 $100 A/mm^2$급 Bi-2223테이프 ($100 A/mm^2$ Class Bi-2223 Tapes in Electromechanical Devices)

  • 류경우;최경주;성기철;류강식
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제4권1호
    • /
    • pp.55-60
    • /
    • 2002
  • $100 A/mm^2$ class Bi-2223 tapes have recently become commercially available. Some important characteristics of the tapes, e .g. critical current, ac loss, characteristics at joint, fault current characteristics, are required for an application such as a power cable or a power transformer. In this paper they have been investigated experimentally. The results indicate that the self-field loss of the high current density tapes is not negligible, compared to resistive loss in a copper wire for the same currents. In a cable, the self-field loss for relatively large currents is much larger than the magnetization loss due to an external field. But in a transformer, the magnetization loss is dominant, compared to the self-field loss. Finally the fault current characteristics show that the high current density tapes are never safe from burn-out even for fault currents with a few cycles.

고온초전도체의 자기자계손실 측정 (Measurement of the Self-field Loss in the HTS Tape)

  • 심정욱;차귀수;이지광;한승엽
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 A
    • /
    • pp.274-276
    • /
    • 1999
  • Transport current is the HTS tape generates the self field loss. To measure the self field loss, rectangular voltage tap has been used. In this paper, self field loss was measured using the spiral voltage tap method. Result of the measurement was compared with that of the theoretical.

  • PDF

초전도 선재에서의 자기 자계 손실 해석 (Self-field loss analysis of multifilamentary superconducting wire)

  • 이지광;김우석;한송엽;김호성;차귀수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.160-162
    • /
    • 1996
  • The estimation of AC losses is demanded for higher efficiency and stability in AC use of superconducting coils. Hysteresis loss occurred by a.c. transport current is called of self field loss, and it is major part of losses generated in a.c. superconducting wire in case of located in low external magnetic field as superconducting transformer with iron core, or in short twist pitch wire, multiply stacking cable. In this paper, we calculate self field loss of superconducting wire.

  • PDF

장척 Bi-2223/AgMgNi 테이프의 자기자계손실 특성 (Self-field Loss Characteristics of a long Bi-2223/AgMgNi Tape)

  • 류경우;박권배;차귀수;최경달;이지광;한송엽
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권4호
    • /
    • pp.240-245
    • /
    • 2000
  • The self-field losses in a long multifilamentary Bi-2223/AgMgNi tape with varying transport current, voltage tap configurations, frequency and tape arrangements were investigated. Experimental results show that the measured losses are strongly dependent on voltage gap configurations but independent on tape arrangements. All voltage taps except the center tap are found to agree well with those predicted by Norris for an elliptical conductor. The self-field losses are purely hysteretic in nature in the range of applied frequencies for the transport currents below the critical current.

  • PDF

교류용 초전도선에서의 자기자계 손실에 관한 연구 (Analysis of Self-Field Losses in AC Superconducting Wire)

  • 이지광;차귀수;한송엽
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 A
    • /
    • pp.250-252
    • /
    • 1997
  • Phase difference of external magnetic field and self field is known to do an important role in the generation of the AC loss. This paper analize the AC loss of AC superconducting wire in combined action of an AC transport current and AC magnetic field for various phase differences.

  • PDF

실용고온초전도테이프의 교류손실에 대한 Round-robin테스트 (Round-robin Test on AC Losses in a Technical High-Tc Superconducting Tape)

  • 류경우;최병주;황시돌
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권7호
    • /
    • pp.437-443
    • /
    • 2004
  • In this work the AC loss measurement setup based on an iron core background magnet, not used in a conventional one, has been successfully developed. To prove its validity, a round-robin test for the same Bi-2223 tape sample among three institutes has been done. The results show that the self-field and magnetization losses from the developed setup well agree with the losses measured at two other institutes of Korea Basic Science Institute and Yokohama National University. The measured magnetization losses for parallel or perpendicular fields can be well predicted from the slab model or the strip model for a filamentary region. However the magnetization losses for longitudinal fields can be rather predicted by the slab model for a decoupled filament. The self-field losses are well explained by the Norris ellipse model.

AC loss comparison of Bi-2223 and coated conductor HTS tapes under bending

  • Kim, Hae-Joon;Cho, Jeon-Wook;Sim, Ki-Deok;Kim, Jae-Ho;Kim, Seok-Ho;Jang, Hyun-Man;Lee, Soo-Gil
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제9권4호
    • /
    • pp.41-45
    • /
    • 2007
  • Superconductor is developed for applications in high-power devices such as power-transmission cables, transformers, motor and generators. In such applications, HTS tapes are subjected to various kinds of stress or strain. AC loss is also important consideration for many large-scale superconducting devices. In the fabrication of the devices, the critical current $(I_c)$ of the high temperature superconductor degrades due to many reasons including the tension applied by bending and thermal contraction. These bending or tension reduces the $I_c$ of superconducting wire and the $I_c$ degradation affects the AC loss of the wire. The $I_c$ degradation and AC loss (self field loss) of Bi-2223 HTS and Coated conductor were measured under tension and bending conditions at 77K and self-field.

2중 연선 초전도 케이블에서 소선내의 필라멘트의 트위스트 방향이 자기자계 손실에 미치는 영향 (The Influence on self Field Losses in 2nd Stage Superconducting Cable for Different Twist Direction of Filaments)

  • 이지광;차귀수;정희원
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제1권1호
    • /
    • pp.38-41
    • /
    • 1999
  • Strands composing multistage superconducting cables for AC power applications have twisted structure in each stage for lower AC loss and higher stability. So, when transport currents flow in a cable, each strand is exposed to longitudinal and azimuthal magnetic fields produced by transport current flowing in strand itself and Iongitudinal and transverse magnetic fields by transport current flowing in twisted cable. In this paper. we study the influence on self field lesses generated in second stage superconducting cable for different twist direction of filaments in a strand considering twist of strands in cables.

  • PDF

고온 초전도 tape의 임계전류 저하에 따른 교류손실 특성 (AC loss Characteristics under Critical Current Degradation of HTS Tapes)

  • 김해준;조전욱;김재호;심기덕;곽동순;배준한;김해종;성기철
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제7권3호
    • /
    • pp.29-33
    • /
    • 2005
  • Critical current$(I_c)$ degradation of High $T_c$ Superconducting(HTS) tapes and AC loss under mechanical load is one of the hottest issues in HTS development and application. Mechanical load reduces the critical current of superconducting wire, and the $I_c$ degradation affects the AC loss of the wire. We measured the $I_c$ degradation and AC loss under tension and bending of Bi-2223 tapes made by 'Powder-in-Tube' technique at 77K with self-field. Also, we have studied the frequency characteristics on self-field AC loss in multi-filamentary Bi-2223/Ag tape at 77K. The measurement results and discussions on the relationship between $I_c$ degradation and AC loss are presented.

고온 초전도체의 임계전류 저하에 따른 교류 손실 특성 (Ac Loss Characteristics under Critical Current Degradation of HTS Tapes)

  • 김해준;김재호;심기덕;조전욱;곽동순;김해종;성기철
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.286-287
    • /
    • 2005
  • Critical current(Ic) degradation of HTS tapes and AC loss under mechanical load is one of the hottest issues in HTS development and application. Mechanical load reduces the critical current of superconducting wire, and the Ie degradation affects the AC loss of the wire. We measured the Ie degradation and AC loss under tension and bending of Bi-2223 tapes processed by "Powder-in-Tube" technique at 17K with self-field. And we have studied the frequency dependence of self-field AC loss in multi-filamentary Bi-2223/Ag tape at 77K. The measurement results and discussions on the relationship between Ic degradation and AC loss are presented.

  • PDF