• 제목/요약/키워드: sealed cavity

검색결과 28건 처리시간 0.029초

Cavity를 갖는 SDB SOI 구조의 제작 (Fabrication of SDB SOI structure with sealed cavity)

  • 강경두;정수태;주병권;정재훈;정귀상
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.557-560
    • /
    • 2000
  • Combination of SDB(Si-wafer Direct Bonding) and electrochemical etch-stop in TMAH anisotropic etchant can be used to create a variety of MEMS(Micro Electro Mechanical System). Especially, fabrication of SDB SOI structures using electrochemical etch-stop is accurate method to fabrication of 3D(three-dimensional) microstructures. This paper describes on the fabrication of SDB SOI structures with sealed cavity for MEMS applications and thickness control of active layer on the SDB SOI structure by electrochemical etch-stop. The flatness of fabricated SDB SOI structure is very uniform and can be improved by addition of TMAH to IPA and pyrazine.

  • PDF

Sealed amalgam restoration의 미세누출에 관한 연구 (A STUDY ON MICROLEAKAGE OF SEALED AMALGAM RESTORATION)

  • 이상헌;이재천;이상훈
    • 대한소아치과학회지
    • /
    • 제27권1호
    • /
    • pp.54-61
    • /
    • 2000
  • 아말감은 널리 사용되어 온 대표적 치과재료이지만 치질과의 접착성이 없어 와동의 형태에 의해 유지되는 단점을 가진다. 아말감 수복물은 산화물에 의한 변연봉쇄가 일어나기 전까지 초기에 큰 미세누출을 보이며 수복초기에 이를 적절하게 예방하지 않으면 타액이나 미생물이 와동내에 침투하게 되고 이로 인해 수복 후의 과민반응, 충전물의 용해 및 파괴, 변연 변색과 2차 우식이 유발되어, 결과적으로 수복물의 수명이 단축되며 치수 병변이 발생될 수도 있다. 최근 기존 아말감 수복의 장점을 그대로 유지하면서 치질삭제를 줄이고 변연을 봉쇄하며 소와열구에 예방적 처치를 함께 할 수 있는 수복법이 제안되었는데 이를 이른바 sealed amalgam이라 한다. 이 술식은 예방적 확대 없이 병소만을 제거한 뒤 수복물 변연과 인접 소와열구에 치면열구전색재를 도포함으로서 소와열구의 예방적 충전은 물론 수복물 변연과 치질사이의 틈을 봉쇄하여 미세누출을 감소시킬 수 있다고 하였다. 이에 저자는 아말감 수복후 수복물의 마무리 처리와 전색재 적용시점을 달리 하여 sealed amalgam 수복과 기존의 아말감 수복과의 미세누출의 차이를 비교하고자 30개의 상, 하악 소구치를 준비하여 V급 와동을 소구치의 협, 설측에 형성하고 통상적 아말감 수복을 시행한 후 다음의 각 군으로 나누어 처리하였다. 제 1 군 : 24시간 후 연마 (대조군) 제 2 군 : 연마하지 않음, 즉시 전색재 적용 제 3 군 : 연마하지 않음, 열순환(thermocycling) 500회 후 전색재 적용 위의 처리 후 각 군을 $5^{\circ}C$$55^{\circ}C$의 온도변화를 30초씩 번갈아 주며 총 500회의 열순환을 실시한 후 1% methylene blue 용액에 침윤시켜서 100% 습도가 유지된 $37^{\circ}C$ 항온기에 24시간 보관하였다. 치아를 레진에 매몰한 후 협설측으로 치아 장축에 평행하게 절단하여 stereomicroscope를 사용해 색소침투도를 관찰하여 다음과 같은 결론을 얻었다. 1. 평균 미세누출은 연마하지 않고 바로 치면열구전색재를 도포한 2군이 가장 낮았고, 연마만 시행한 1군이 가장 높았다. 2. 실험군간의 미세누출 비교에서 연마만 시행한 1군은 2군에 비해 미세누출이 켰으며 통계적으로 유의성 있는 차이를 보였다(p<0.05). 3군은 1군보다 평균미세누출이 작았으나 통계적으로 유의한 차이가 없었다(p>0.05). 2군은 3군보다 평균 미세누출이 작았으나 통계적으로 유의한 차이가 없었다(p>0.05).

  • PDF

예방적 레진수복의 미세누출에 관한 연구 (A STUDY ON MICROLEAKAGE OF PREVENTIVE RESIN RESTORATION)

  • 구현정;이상훈;한세현
    • 대한소아치과학회지
    • /
    • 제28권3호
    • /
    • pp.504-511
    • /
    • 2001
  • 예방적 레진수복은 교합면 열구전색의 개념을 확대하여 초기우식에만 국한한 와동을 형성하여 복합레진으로 충전한 후 나머지 건전한 부위의 소와열구를 치면열구전색재로 도포하는 것이다. 충전제가 첨가된 치면열구전색재로서 작은 와동의 수복도 가능하다는 새로운 방법은 소아환자의 치료시 술자와 환자 모두에게 도움을 줄 수 있을 것이다. 그러나 예방적 레진수복을 시행하여 비교한 연구가 아직까지는 부족한 실정이다. 이에 저자들은 4가지 방법의 예방적 레진수복시의 미세누출을 비교해보고자 하였으며 레진수복만을 한 경우도 함께 비교하여 보았다. 55개의 상, 하악 소구치를 준비하여 I급와동을 교합면에 형성하고 다음과 같이 수복하였다. 제1군 : 와동을 복합레진(Z-100)으로 수복 제2군 : 와동을 복합레진(Z-100)으로 수복 중합후, 비충전 전색재인 Teethmate F-1으로 소와열구도포 제3군 : 와동을 복합레진(Z-100)으로 수복 중합후, 충전 전색재인 Ultraseal XT-plus로 소와열구도포 제4군 : 와동과 소와열구를 한 번에 Ultraseal XT-plus로 수복 제5군 : 와동과 소와열구를 나누어 Ultraseal XT-plus로 수복 위와 같이 처리한 치아를 $5^{\circ}C$$55^{\circ}C$의 수조에 번갈아 30초씩 500회의 열순환을 실시하고 1% methylene blue용액에 24시간 담근 후 수세하고 투명레진에 매몰하였다. 매몰된 치아를 협설측으로 치아장축방향으로 평행하게 절단한 후 입체현미경으로 염색용액의 침투정도를 관찰하여 다음의 결과를 얻었다. 1. 평균 미세누출은 4군에서 가장 높았고, 3군에서 가장 낮았다. 평균 미세누출은 4>1>5>2>3군의 순으로 감소하였다. 2. 군간의 미세누출 비교에서 1군은 5군과는 통계학적으로 유의한 차이가 없었으나 2군, 3군보다 유의하게 높은 미세누출을 보였고(p<0.05), 4군보다는 유의하게 낮은 미세누출을 보였다(p<0.05). 3. 2군은 3군과는 통계학적으로 유의한 차이가 없었으나 4군, 5군보다는 유의하게 낮은 미세누출을 보였다(p<0.05). 4. 3군은 4, 5군보다 통계학적으로 유의하게 낮은 미세누출을 보였다(p<0.05). 5. 5군은 4군보다 통계학적으로 유의하게 낮은 미세누출을 보였다(p<0.05).

  • PDF

Formocresol이 손상치수조직(損傷齒髓組織) 치유(治癒)에 미치는 영향(影響)에 관(關)한 실험적(實驗的) 연구(硏究) (AN EXPERIMENTAL STUDY ON THE INFLUENCE OF FORMOCRESOL TO THE HEALING PROCESS OF AMPUTATED PULP)

  • 권혁춘
    • Restorative Dentistry and Endodontics
    • /
    • 제12권2호
    • /
    • pp.27-32
    • /
    • 1987
  • After a vital pulpotomy in human permanent teeth, the responses of the remaining pulp tissue under formocresol was studied histologically. The class I cavity was prepared on the teeth and the pulp was amputated. Formocresol was placed over the amputated tissue and the cavity was sealed with zinc phosphate cement and amalgam. The teeth were extracted after 1, and 3 weeks following the operation and were decalcified, sectioned and stained with hematoxylin and losin. Microscopic examination reveals as follows; I. Healing of the pulp at the amputated site did not occur in the pulps treated with formocresol. 2. At one week the pulps were normal except only slight inflammatory reaction. 3. At three weeks, the pulps showed the most serious inflammation, bleeding and necrotic state.

  • PDF

An Investigation of the Catalytic Effect with $Nd_{1-x}Sr_{x}CoO_{3}$ Perovskite in a Sealed-off $CO_2$ Laser

  • Oh Heui-Suk;Kim Sung-Ho;Cho Ung-In
    • Bulletin of the Korean Chemical Society
    • /
    • 제13권6호
    • /
    • pp.593-595
    • /
    • 1992
  • To improve the lifetime and output power in a sealed-off $CO_2$ laser, a series of Nd$_{1-x}$Sr$_x$CoO$_3$(x = 0.0, 0.25, 0.40, 0.50, 0.60, 0.75) perovskite-type compounds has been synthesized and used for a cathode material. Using a typical method samples were sintered at 1150$^{\circ}$C and their structures were determined as a cubic form by means of XRD analysis. The degrees of $CO_2$ dissociation were measured by PAS (photoacoustic spectroscopy) with the lapse of time. In the case of $Nd_{0.4}$Sr$_{0.6}$$CoO_3$, which showed the highest catalytic cathode effect, only 7% of the initial $CO_2$ concentration were dissociated at 30 torr of gas mixture and 5 mA of discharge current. The more the gas pressure decreased and the discharge current increased, the more the degree of dissociation occurred. The ability of catalytic cathode to regenerate CO$_2$ in the laser cavity lies in order for x, 0.60 > 0.50 > 0.40 > 0.75 > 0.25 ${\gg}$ 0.0. Except for the case of x = 0.0 the amounts of $CO_2$ dissociation were found to be within 7-15% of the initial $CO_2$ concentration.

Surface penetrating sealant가 치경부 수복물의 미세누출에 미치는 영향 (EFFECT OF SURFACE PENETRATING SEALANT ON THE MICROLEAKAGE OF CERVICAL RESTORATIONS)

  • 김성원;조용범;홍찬의
    • Restorative Dentistry and Endodontics
    • /
    • 제26권1호
    • /
    • pp.64-76
    • /
    • 2001
  • Despite the improvements in bond strengths of dentin adhesives and resin-modified glass ionomers, the marginal seal of cervical restorations remains a concern. Microleakage at poorly sealed margins can result in staining, post-operative sensitivity, pulpal irritation, and recurrent caries. The objective of this study was to evaluate the effect of surface penetrating sealant(SPS) on the microleakage of cervical restorations. 45 extracted human teeth were selected, and Class V preparations were prepared on the both buccal and lingual surface of the teeth to the following dimensions : 1.5mm axially, 3mm mesiodistally, and 3mm incisogingivally. After cervical restoration with composite resin, compomer, glass ionomer each restoration was treated as three methods: No Tx., Scotchbond Multipurpose Adhesive$^{\circledR}$, Fortify$^{\circledR}$. The sections were examined with a stereomicroscope to determine the extent of microleakage at enamel and dentin margins. The results of this study were as follows. 1. All groups showed some microleakage. 2. Gingival cavity wall with cementum margin showed significantly higher leakage value than occlusal cavity wall with enamel margin. 3. The group treated with SPS showed significantly lower leakage value than no treated group(p<0.05). But there is no difference between Fortify$^{\circledR}$ and Scotchbond Multipurpose adhesive$^{\circledR}$. The results of this study suggest that SPS are effective in reducing microleakage of class V restorations. But it is certain that some microleakage still occurred despite the application of SPS.

  • PDF

퍼지 전문가 시스템을 이용한 강관 하이드로포밍의 성형성 예측에 관한 연구 (Optimization of tube hydroforming process by using fuzzy expert system)

  • 박광수;김동규;이동활;문영훈
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2004년도 춘계학술대회 논문집
    • /
    • pp.194-197
    • /
    • 2004
  • In the tube hydroforming process, a tube is placed into the die cavity and the ends of the tube are sealed by fixing the axial cylinder piston into the ends. Then the tube is pressurized with a hydraulic fluid and simultaneously the axial cylinders move to feed the material into the expansion zone. Therefore, the quantitative relationship between process parameters such as internal pressure and feeding amount and hydroformabillity, is hard to establish because of their high complexity and many unknown factors. In this study, the empirical and the quantitative relationship between process parameters and hydroformabillity are analyzed by fuzzy rules. Fuzzy expert system is an advanced expert system which uses fuzzy rule and approximate reasoning. Many process parameters are converted to the quantitative relationship by use of approximate reasoning of fuzzy expert system. The comparison between experimentally measured hydroformabillity from hydroforming experiments and the predicted values by fuzzy expert system shows a good agreement.

  • PDF

Air Bulging을 이용한 열간 알루미늄 성형에 관한 연구 (A Study on Al Hot Forming Using Air Bulging)

  • 박동환;김태준
    • 소성∙가공
    • /
    • 제24권1호
    • /
    • pp.20-27
    • /
    • 2015
  • Hot tensile tests were conducted at different temperatures ranging from $20^{\circ}C$ to $550^{\circ}C$ to evaluate the mechanical properties of Al5052 seamless tubes. Such tubes can provide the technological foundation for complex forming using hot air bulging. Hot air bulging is one of the recently developed hydroforming techniques and it has some limitations in terms of cycle times. The benefits of hot air bulging are weight and cost savings through part consolidation and reduced post-forming processes such as welding and piercing. In order to extend the forming limits of Al lightweight material hot air bulging was investigated. A heated tube was placed in a heated die and sealed at the ends by sealing cylinders. The heated tube was subsequently expanded against the die cavity wall by internal pressure using air medium. The results of the current study show that axial feeding speed and air pressure have an effect on the formability of Al tubes during air bulging at elevated temperatures.

Air Bulging을 이용한 열간 알루미늄 성형에 관한 연구 (Study on Al Hot Forming using Air Bulging)

  • 박동환;강성수;김병년
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2009년도 춘계학술대회 논문집
    • /
    • pp.145-147
    • /
    • 2009
  • The benefits of hydroforming technology are known as weight and cost savings through part consolidation and reduced post-forming processes such as welding and piercing. Hydroforming technology has some weaknesses in terms of process cycle times. But, as the hydraulic system and process designs are continuously developed, the cycle time is also reduced to acceptable and competitive levels. Hot air bulging is one of recently developed hydroforming techniques. Hot air bulging in order to further extend the forming degrees of Al lightweight material is investigated. A heated tube is placed in a heated die and sealed at the ends by sealing cylinders. The tube is subsequently expanded against the die cavity wall by internal pressure provided by air medium. The result of this study shows that axial feeding speed and air pressure have an effect on formability of Al air bulging at elevated temperature.

  • PDF

A Direct Detection of $CO_2$ in Sealed-off $CO_2$ Discharge Tube by Optoacoustic Effect

  • Kim Sung-Ho;Choi Joong-Gill;Cho Ung-In
    • Bulletin of the Korean Chemical Society
    • /
    • 제15권1호
    • /
    • pp.23-25
    • /
    • 1994
  • A simple analytical method that allows direct monitoring of small amount of CO$_2$ in a CO$_2$ discharge tube which utilizes the optoacoustic detection technique is described. The dependence of the optoacoustic signal on the mole fraction of CO$_2$ was shown that the system responded linearly to the amount of CO$_2$ present in the miniature discharge cavity equipped with Cu electrodes. It was also found that fraction of dissociated CO$_2$ varied from 14 to 37% of the initial concentration which depended on the current and the pressure in the tube. This simple and easy detection method has proven to possess the practical advantages over the conventional systems for the study of CO$_2$ laser electrodes.