• Title/Summary/Keyword: scanned data

Search Result 479, Processing Time 0.025 seconds

A Study on BWMS Installation for a Ship without CAD Data (설계 데이터가 손실된 선박에 대한 BWMS 설치 계획 연구)

  • Jeon, Songkwun;Choi, Young
    • Korean Journal of Computational Design and Engineering
    • /
    • v.21 no.1
    • /
    • pp.1-8
    • /
    • 2016
  • After 2017 years, BWMS units must be installed in the existing ship as well as the new ship by the ballast water management convention. Software tools that can help automatically searching for BWMS installation space to avoid pipes and equipment in the engine room of the existing ship will be very useful in the BWMS layout design. In this study, voxel representation of scanned data is generated first to search space efficiently. Simplified voxel models of each unit are prepared to be located in the engine room space as well. Distance between connected models is calculated through the arrangement direction and position of each model. Sums of distance between connected models are compared for the optimal configuration. It is assumed that the sum of distance between connected models depicts the pipe usage. The proposed method can save the time needed for BWMS installation design and allows optimal configuration of BWMS units.

Optimum Weight in Spline for Surface Model

  • Shon, Ho-Woong;Oh, Seok-Hoon;Kim, Young-Kyung
    • Journal of the Korean Geophysical Society
    • /
    • v.8 no.1
    • /
    • pp.23-33
    • /
    • 2005
  • The digital surface model (DSM) is used for several purposes in photogrammetry, remote sensing and laser scanned data such as orthoimage production, contours erivation, extraction of height information. Creation of a surface model from point-clouds (3-D sparse points) that can be derived from stereo imagery and range data (e.g. laser scanned data) can be done with several mathematical interpolation models. In this paper, thin-plate-spline (TPS) is used for digital surface modeling. Determination of suitable weight is an important problem in thin-plate function for a surface. The Voronoi algorithm has been proposed as a method for determination of the weight in thin-plate-spline. In this paper, methods has been tested for different surfaces. The results show that thin-plate-spline can be independent of weight.

  • PDF

DIMENSIONAL ACCURACY OF DENTURE BASE USING LASER SCANNER OF REVERSE ENGINEERING TECHNIC (Reverse Engineering 기법의 레이저 스캐너를 이용한 의치상의 정확도에 관한 연구)

  • Lee, Si-Hyuk;Chang, Ik-Tae;Yim, Soon-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.2
    • /
    • pp.167-184
    • /
    • 1999
  • The purpose of this study was to evaluate and compare the at of denture bases processed by injection pressing technic using laser scanner of reverse engineering technic. The auther duplicated 20 maxillary edentulous models and 20 mandibular edentulous models, which were scanned on HYSCAN 45C 3D BCANNER(Hymarc Co., Canada). The scanned data were stored in the personal computer using SURFACER (Imageware Co. U.S.A.) software program. After 40 dentures were cured by PERform Inkovac system, SR-Ivocap system, Palajet system, and Sulfon system, they were stored in water at room temperature fir 24 hours. The dentures were scanned on HYSCAN 45C 3D SCANNER(Hymarc Co., Canada). The scanned data were stored in the personal computer using SURFACER (Imageware Co., U.S.A.) software program. By overlapping two images using the same program, the fit between two surfaces was scaled by positive and negative errors. The obtained results were as follows 1. In the upper denture, most of the positive errors occurred on the lingual side of anterior alveolar ridge and the negative errors were on the flange of denture bases. 2. In the lower denture, most of the positive errors occurred on the inner side of lingual flange and the negative errors were on the border of anterior labial flange areas, 3. There were no statistical differences among the positive errors of the four types of injection denture curing methods and also no statistical differences between negative errors except only in negative maximum errors. 4. In PERform system and SR-Ivocap system, they have the tendency of inaccurate at of lower denture bases comparing to that of upper denture bases. 5. The negative error scales were greater than the positive error scales in all types of injection denture curing methods.

  • PDF

Visualization of 3D Scanned Model for Interpretation of Heritage - Case of Dinosaur Tracks for Documentation and Interpretation (문화 및 자연 유산의 해석을 위한 3차원 스캔 모델의 가시화 - 공룡발자국의 기록과 해석 사례)

  • Ahn, Jaehong;Kong, Dal-Yong;Wohn, Kwang-Yun
    • Journal of the HCI Society of Korea
    • /
    • v.8 no.1
    • /
    • pp.19-28
    • /
    • 2013
  • As yet the use of 3D scanning technology has been limited to documentation, preservation and monitoring in cultural and natural heritage domain. Appropriate visualization of precise geometric information in scan data can support scientific interpretation of the domain experts. We studied the rendering techniques which visualize the required features from scanned models, and proposed a 3D scan data visualization pipeline, rendering methods, and a classification scheme. As a case study, we analyzed the traditional method in the study of dinosaur tracks and performed the visualization of 3D scanned models. A user test based on the result confirmed an effectiveness of the proposed method. This research showed a practical method in which 3D scanned models can be used to effective interpretation of heritage.

  • PDF

Evaluation of Efficacy of Body Shaper for Senior Women Using 3D Scanned Data (3차원 데이터를 활용하여 시니어를 대상으로 한 바디쉐이퍼의 보정기능성 평가)

  • Kim, Soyoung;Hong, Kyunghi;Lee, Heeran
    • Fashion & Textile Research Journal
    • /
    • v.21 no.2
    • /
    • pp.220-230
    • /
    • 2019
  • The Fourth Industrial Revolution has increased studies on observing the cross section by overlapping the clothing worn using 3D human body data. However, there is a lack of studies on the effect of pressure clothing that contracts the shape of the human body. Therefore, this study objectively evaluated the shaping functionality of body shapers using 3D scan and 3D data. Two types of commercial body shapers were selected for this study. The nude body and body wearing body shapers were then scanned. A 3D program evaluated the shaping functionality by overlapping the nude state with the body wearing body shaper A and B respectively. As a result, it was found that the effect of body shapers could be adequately observed according to body parts. The smaller body shaper was shown to have superior shaping capability with the abdomen more affected. Analysis of the horizontal cross section indicated that the waist circumference decreased by 6 cm when wearing body shaper A and decreased by 12cm when wearing body shaper B. The volume of the waist part decreased by 8.6% when wearing body shaper A and by 20.4% when wearing body shaper B. Therefore, it is more effective to compare the objective shaping functionality by body parts using the overlapped 3D scanned data rather than using exterior evaluation or length measurement when wearing clothing that contracts the body shape.

3-D Body Typing of Korean Adults and its Application to Vehicle Design (자동차 설계를 위한 한국인 3차원 표준 형상의 선정)

  • Hong, Seung-U;Park, Seong-Jun;Jeong, Ui-Seung
    • Journal of the Ergonomics Society of Korea
    • /
    • v.25 no.2
    • /
    • pp.85-94
    • /
    • 2006
  • The purpose of this study is to extract typical body shapes of Korean adults based on the three-dimensional Korean anthropometric data measured through 5th national anthropometric survey and to examine the suitability of the 3-D human shape data for the interior packaging. 36 three-dimensional anthropometric variables related to the design of vehicle interior were considered for the appraisal of typical body shapes. Four major factors were extracted by the factor analysis and factor scores were calculated for all subjects. Typical or standard drivers of Korean adults were selected by the minimum deviation criteria for the four factor scores with respect to 5th, 50th, and 95th percentiles, respectively. Typical drivers of Korean adults were visualized by the CATIA-HUMAN program due to the absence of proper application software for three-dimensionally scanned human body data. There are considerable differences between the anthropometric data of Korean adults and those provided by CATIA-HUMAN program, which shows that the modeling data provided by CATIA-HUMAN should not be directly applied to the ergonomic evaluation for the vehicle design. This suggests the necessity for the development of suitable software for scanned human shape data. It is also expected that the anthropometric data of typical drivers extracted from this study help design package layouts and improve the suitability of ergonomic evaluation for Korean customers.

Development of a Program That Computes the Position of the Club Face Based on the Experimental Data (실험 데이터를 이용한 클럽 페이스 움직임 분석 프로그램 개발)

  • Park, Jin;Shin, Ki-Hoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.20 no.2
    • /
    • pp.231-237
    • /
    • 2010
  • The moving trajectory of a golf ball is mainly determined by the angles of the clubface and the trajectory of the club shaft. This paper presents a computer program for analyzing the position and angles of the club while the club moves in a circular motion. For this purpose, a mathematical algorithm was developed and implemented on the experimental data(5 m and 10 m carries) using VC++ and OpenGL. A skilled female golfer(174 cm, 65 kg, 0 handicap) was participated in data collection for the short approach shots. An iron club(Titleist 52 degree, 91.5 cm length, 450 g mass), attached with five reflective markers(12 mm), was used to collect experimental data. However, exact 3D coordinates and angles of the clubface are not directly calculated from measured data. A reverse engineering platform(Minolta Vivid910 hardware and Rapidform software) was thus employed to acquire the scanned data of the clubface. The scanned data and measured data were first aligned by applying appropriate coordinate transformations, and then exact coordinates and angles of clubface could be obtained at each position during circular motion. The program(Club Motion Analysis 1.0) exports the open, heel, loft angles of the club.

Analysis of overlap ratio for registration accuracy improvement of 3D point cloud data at construction sites (건설현장 3차원 점군 데이터 정합 정확성 향상을 위한 중첩비율 분석)

  • Park, Su-Yeul;Kim, Seok
    • Journal of KIBIM
    • /
    • v.11 no.4
    • /
    • pp.1-9
    • /
    • 2021
  • Comparing to general scanning data, the 3D digital map for large construction sites and complex buildings consists of millions of points. The large construction site needs to be scanned multiple times by drone photogrammetry or terrestrial laser scanner (TLS) survey. The scanned point cloud data are required to be registrated with high resolution and high point density. Unlike the registration of 2D data, the matrix of translation and rotation are used for registration of 3D point cloud data. Archiving high accuracy with 3D point cloud data is not easy due to 3D Cartesian coordinate system. Therefore, in this study, iterative closest point (ICP) registration method for improve accuracy of 3D digital map was employed by different overlap ratio on 3D digital maps. This study conducted the accuracy test using different overlap ratios of two digital maps from 10% to 100%. The results of the accuracy test presented the optimal overlap ratios for an ICP registration method on digital maps.

Dental Impression Measurement Based on an Adaptive Measuring Process Plan (적응형 측정계획 기반 치과인상 측정)

  • Park, Sang Chul;Chung, Yong Ho;Hwam, Won Kyung
    • Korean Journal of Computational Design and Engineering
    • /
    • v.18 no.4
    • /
    • pp.283-289
    • /
    • 2013
  • Presented in this paper is an adaptive measuring procedure of dental impression using the Structured Light System. While measuring a complex object, such as dental impression, in the reverse engineering, it is not possible to acquire all parts of the scanned surface. Missing scanned data is resulted in holes in a created triangular mesh. The focus of this paper is to introduce an algorithm for automatic identification of additional scanning orientations to fill holes that are created by a default scan. The proposed algorithm was developed by the three major technological requirements: camera visibility, projector visibility, data reliability. In order to satisfy the requirements, the proposed algorithm determines additional scanning orientation from the orientation of a projection plane derived from the average normal vector of boundary triangles.

The Fast 3D mesh generation method for a large scale of point data (대단위 점 데이터를 위한 빠른 삼차원 삼각망 생성방법)

  • Lee, Sang-Han;Park, Kang
    • Proceedings of the KSME Conference
    • /
    • 2000.11a
    • /
    • pp.705-711
    • /
    • 2000
  • This paper presents a fast 3D mesh generation method using a surface based method with a stitching algorithm. This method uses the surface based method since the volume based method that uses 3D Delaunay triangulation can hardly deal with a large scale of scanned points. To reduce the processing time, this method also uses a stitching algorithm: after dividing the whole point data into several sections and performing mesh generation on individual sections, the meshes from several sections are stitched into one mesh. Stitching method prevents the surface based method from increasing the processing time exponentially as the number of the points increases. This method works well with different types of scanned points: a scattered type points from a conventional 3D scanner and a cross-sectional type from CT or MRI.

  • PDF