• Title/Summary/Keyword: scan pattern

Search Result 395, Processing Time 0.032 seconds

Direct Clothing Pattern Development from the 3D Illustration on the Personal Human Body Model (인체모델과 3차원 일러스트레이션을 이용한 의복패턴개발)

  • Park, Hye-Jun;Hong, Kyung-Hi
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.32 no.2
    • /
    • pp.340-347
    • /
    • 2008
  • A prototype of 3D clothing design system with a direct pattern development function was suggested, reflecting intuitive design functions and design modifications while considering the fit of clothing patterns with the 3D human body in the virtual 3D space. The research method was as follows. Clothing models were created using a 3D design tool, 3ds max on the surface of 3D human body model made by scanning an actual human body. 3D illustrations were completed by revising the fit and sizing of the human body and clothing models. 2D T-shirt pattern was produced 3D illustrations using from a 3D scanning data modeling solution RapidForm 2004, a 2D conversion program for 3D data called 2C-AN, and Yuka CAD. As a result, the following conclusions were made. The fit of the clothing and human body can be adjusted by reflecting individual body figure characteristics and 3D illustrations over the actual 3D body model. Furthermore, intuitive design support functions were intensified overcoming the weak point of existing 3D clothing design system by developing the direct clothing design in the virtual 3D space. 3D illustration design modifications can be directly reflected on clothing patterns from 3D illustrations by 3D clothing design system developed in this study.

Occlusal Analysis of the Patients with Temporomandibular Disorders Using T-Scan II System (T-Scan II 시스템을 이용한 측두하악장애 환자의 교합 분석)

  • Yang, Dong-Hyo;Lee, Won-Seop;Kim, Mee-Eun
    • Journal of Oral Medicine and Pain
    • /
    • v.32 no.1
    • /
    • pp.105-111
    • /
    • 2007
  • Correlation between occlusal contact pattern and TMD have been hypothesized and partially investigated but results are controversial and not conclusive. The purposes of this study were to compare right-to-left difference of occlusal contact pattern, through contact points, contact force and occlusal balance, in the patients with unilateral TMD and also to evaluate its change related with TMD treatment. 36 patients with unilateral TMD from Department of Oral Medicine in Dankook University Dental Hospital were selected in this study (M:F=7:29, mean age of $29.2{\pm}14.8$ years). A computerized T-Scan II system (Tekscan, INC., USA) was employed for occlusal analysis and the simultaneity and occlusal balance through the number of tooth contact and magnitude of contact force were determined before and after TMD treatment. The number of contact points and contact force was more on the unaffected side than the affected side before treatment (p=0.056 and p=0.060, respectively) while significant difference between both sides was not found after treatment. The number of contact points and contact force on the affected sides significantly increased after treatment (p=0.038 and p=0.052), but the unaffected sides exhibited no significant difference between before and after treatment. In addition, sides difference in relative contact force decreased from about 27% to about 12% after TMD treatment (p=0.001). According to the results of this study, it is likely that unilateral TMD impairs right-to-left occlusal balance and that conservative TMD treatment alleviates the imbalance, subsequently leading to more symmetrical occlusal condition with increased contact points and force.

Significance of Dynamic MRI in Brain Tumors

  • Kim, Dong-Woo;Sung, Soon-Ki;Song, Young-Jin;Choi, Soon-Seop;Kim, Dae-Cheol;Choi, Young-Min;Huh, Won-Ju;Kim, Ki-Uk
    • Journal of Korean Neurosurgical Society
    • /
    • v.42 no.1
    • /
    • pp.27-34
    • /
    • 2007
  • Objective : On the magnetic resonance image (MRI) of the infiltrating brain tumor, enhancement is usually higher in malignant tumor than in benign tumor, and tumor cells can invade into the peritumoral area without definite enhancement. In various pathological conditions, the blood brain barrier (BBB) becomes changed to pathological condition, allowing various materials extravasating into the interstitial space, and degree of enhancement is depend on the pathology. Authors performed dynamic MRI on enhancing and surrounding edematous area in order to evaluate the degrees of opening of BBB, to differentiate tumor from non-tumorous condition, and to determine its relationship with the recurrence of the tumor. Methods : Dynamic MRI was performed in 25 patients. Dynamic scans were done every 15 seconds after administration of Gd-DTPA on the enhancing and surrounding area for maximum 300 seconds, and the patterns of enhancement were ana lysed. The enhancement curve with initial steep increase followed by slow decrease was defined as "N pattern", those with initial steep increase followed by additional slow increase as "T pattern", and those with initial steep increase followed by plateau as "E pattern". Histopathological findings were compared with the dynamic scan. Results : The graphs taken from enhancing area showed "T pattern" regardless of pathology. In the surrounding area, "T pattern" was noticed in the malignant tumors, but "E pattern" or "N pattern" was noted in low-grade or benign tumors and non-tumorous condition. "T pattern" in the surrounding area was related to the malignant with tumor cell infiltration and recurrence. Conclusion : The results suggest that the malignant tumor infiltration changes the condition of BBB enough to extravasate the Gd-DTPA. Enhancement pattern in the surrounding edematous area may be a useful information to differentiate the malignant glioma with the low-grade and benign tumors or other non-tumorous conditions.

Location Generalization Method of Moving Object using $R^*$-Tree and Grid ($R^*$-Tree와 Grid를 이용한 이동 객체의 위치 일반화 기법)

  • Ko, Hyun;Kim, Kwang-Jong;Lee, Yon-Sik
    • Journal of the Korea Society of Computer and Information
    • /
    • v.12 no.2 s.46
    • /
    • pp.231-242
    • /
    • 2007
  • The existing pattern mining methods[1,2,3,4,5,6,11,12,13] do not use location generalization method on the set of location history data of moving object, but even so they simply do extract only frequent patterns which have no spatio-temporal constraint in moving patterns on specific space. Therefore, it is difficult for those methods to apply to frequent pattern mining which has spatio-temporal constraint such as optimal moving or scheduling paths among the specific points. And also, those methods are required more large memory space due to using pattern tree on memory for reducing repeated scan database. Therefore, more effective pattern mining technique is required for solving these problems. In this paper, in order to develop more effective pattern mining technique, we propose new location generalization method that converts data of detailed level into meaningful spatial information for reducing the processing time for pattern mining of a massive history data set of moving object and space saving. The proposed method can lead the efficient spatial moving pattern mining of moving object using by creating moving sequences through generalizing the location attributes of moving object into 2D spatial area based on $R^*$-Tree and Area Grid Hash Table(AGHT) in preprocessing stage of pattern mining.

  • PDF

Thallium-201 Perfusion Scan in Peripheral Arterial Disease (말초성 동맥 질환에 있어서 $^{201}T1$을 이용한 말초혈관 관류스캔의 유용성)

  • Nah, Jung-Il;Woo, In-Sook;Kim, Deog-Yoon;Koh, Eun-Mi;Kim, Jin-Woo;Kim, Young-Seol;Kim, Kwang-Won;Choi, Young-Kil
    • The Korean Journal of Nuclear Medicine
    • /
    • v.25 no.2
    • /
    • pp.192-199
    • /
    • 1991
  • Peripheral arterial disease, because of it's significant and prolonged morbidity and related mortality is a major medical and surgical problem. Contrast angiogram remains the essential standard for the anatomic demonstration of disease. It does not, however, provide data suitable for quantification or any evaluation of the microcirculation. For these reasons, radionuclide studies are playing an increasingly important role by not only confirming the diagnosis and offering objective data on the physiologic significance of anatomic lesions, but by offering prognosis of healing and prediction of therapeutic results. In addition, radionuclide procedures offer means to safely and repeatedly monitor response to therapy and long term follow up. The object of this study was to evaluate the clinical availability of $^{201}T1$ perfusion scan in patients with peripheral arterial diseases. We performed $^{201}T1$ perfusion scans in patients with five Buerger' s disease (10 legs), six DM gangrenes (12 legs) and classified three perfusion pattern groups. Finally we compared treatment modalities among each groups and compaired T1-201 perfusion scan findings with angiographic findings in six patients with Buerger's disease. The results were as follows: 1) Seven legs showed increased perfusion in stress image and normal or increased perfusion in resting image (type 1). Six legs showed decreased perfusion in stress image and improved in resting image (type II). Of total 13 legs, only 1 leg needed to amputation. 2) Three legs showed decreased perfusion in stress and resting image (type III), and subsequently all cases were received surgical amputation. 3) In six Buerger's disease patients, there were disagreements in two patients (2 legs) between $^{201}T1$ scan and angiography, in which angiograms were normal but $^{201}T1$ scans showed 'type II' perfusion patterns.

  • PDF

A Study on the Effects of Chewing Side Preference on the Pattern of Occlusal Contacts (저작습관에 따른 교합접촉의 변화양태에 관한 연구)

  • Sun-Oh Kwon;Kyung-Soo Han
    • Journal of Oral Medicine and Pain
    • /
    • v.15 no.1
    • /
    • pp.117-124
    • /
    • 1991
  • The purpose of his study was to investigate the variations of occlusal contact pattern according to chewing side preference. The author selected 59 dental students (mean age 23.6 years) who had no signs and symptoms of masticatory disorders and divided into two groups, that is, bilateral chewing side group and unilateral chewing side group, respectively. For recording, T-Scan System(Teksan Inc., USA) was used and the recorded occlusal contacts were examined as to the number of occlusal contacts, points distribution in dental arch, time sequence and force snapshot. The obtained results were as follow s: 1. Total number of occlusal contacts were more in unilateral chewing side group and there were significant difference in number between right and left side or between chewing and less-chewing side in all two groups. 2. All items related to time sequence showed no statistical significant difference between two groups in any case. 3. Unilateral chewing side group had more occlusal contact force than bilateral group, especially in chewing side. From the above finding, the author considered that there was occlusal unbalance in unilateral chewing side group. 4. Chewing side preference would possibly have more effects on the occurrence rate of anterior tooth contact that the rate of prolonged their contact but proved.

  • PDF

A Case Report: Diagnostic Imaging of a Chondrosarcoma of the Rib in a Dog (개에서 늑골 연골육종에 대한 영상학적 진단증례)

  • Jeong Yu-cheol;Lim Chang-yun;Oh Sun-kyung;Jung Joo-hyun;Lee Chang-woo;Yoon Jung-hee;Choi Min-cheol
    • Journal of Veterinary Clinics
    • /
    • v.22 no.4
    • /
    • pp.444-449
    • /
    • 2005
  • An 11-year-old female, Golden retriever dog with a history of solid mass on the chest wall was referred to Veterinary Medical Teaching Hospital, Seoul National University. The mass was firm on palpation. A soft tissue opacity mass with calcified foci around the right 7th rib and extrapleural patterns around the right 5th rib and 7th rib was shown on thoracic radiographs. The mass of the 7th rib has a mixed-echo pattern with a strong acoustic shadowing and internal vascular signals on ultrasonography. On CT scan, the mass showed contrast enhancement effect, expansive pattern of intrathoracic and extrathoracic legion around costochondral junction. The 7th rib appeared mildly lytic. The mass of the 5th rib had a soft tissue swelling without bone lysis. The mass was diagnosed as a sarcoma by fine needle biopsy. Therefore, the mass was surgically removed. Subsequent histopathological study found the mass was chondrosarcoma.

A STUDY ON THE ANODIC POLARIZATION OF DENTAL AMALGAMS (수종 아말감의 Anodic Polarization에 관한 연구)

  • Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.14 no.1
    • /
    • pp.199-204
    • /
    • 1989
  • The purpose of this study was to observe the anodic polarization curve from 4 kinds of low copper amalgam (Fine cut alloy, Spheralloy, Aristalloy and Amalcap) and 4 kinds of high copper amalgam (Dispersalloy, Sybraloy Orosphere and Tytin) obtained by using the potentiostat. The specimen made as the direction of manufacturer was stored at room temperature for about 7 days. The standard surface preparation was routinely carried out. The 0.9% saline solution was used as electrolyte in pH 6.8-7.0 at $37^{\circ}C$. The open circuit potential was determined after 30 minutes' immersion of specimen. The scan rate was 1mV/sec and the surface area of amalgam exposed to the solution was 0.785$cm^2$ for each specimen. All potentials reported are with respect to Ag/AgCl eelctrode. The following results were obtained. 1. The corrosion potential of high copper amalgams was higher than one of low copper amalgams, and the current density of high copper amalgam was lower than one of low copper amalgams. 2. The low copper amalgams had the similar pattern of polarization curve, but the high copper amalgams had the different pattern one another. 3. The polarization curve of Orosphere amalgam which is the admixed type was similar to one of low copper amalgam.

  • PDF

Fabrication of Grooved Pattern for the Light Guide Plate of TFT-LCD with CO2 Laser (CO2 레이저 빔을 이용한 TFT-LCD 도광판의 패턴 제작에 관한 연구)

  • 김경동;백창일;송철기;안성훈
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.147-150
    • /
    • 2002
  • A light guide panel is an element of the LCD backlight module that is often used for the display of compact electronic devices. In this study, a laser marking system is proposed to fabricate light guide panel, which can be replaced of other manufacturing methods such as silk printing, stamping, and v-cutting methods. The objectives of this research are the establishment of laser marking system, evaluation of laser marking parameters, understanding marking process, application to PMMA, reliability test and quality inspection. A 50W $CO_2$ laser (CW) was used to perform different experiments in which, the influence of some processing parameters (average power, scanning speed) on the geometry and quality of groove pattern was studied. The width of the etched grooves increases with increasing a laser power and decreasing a scan speed. In order to analyze surface characteristics and optical properties (luminance, uniformity), SEM photography and BM7 (luminance measuring system) were used. As a result, the optimal conditions of the process parameters were determined.

  • PDF

An Effective Multiple Transition Pattern Generation Method for Signal Integrity Test on Interconnections (Signal Integrity 연결선 테스트용 다중천이 패턴 생성방안)

  • Kim, Yong-Joon;Yang, Myung-Hoon;Park, Young-Kyu;Lee, Dae-Yeal;Yoon, Hyun-Jun;Kang, Sung-Ho
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.1
    • /
    • pp.14-19
    • /
    • 2008
  • Semiconductor testing area challenges many testing issues due to the minimization and ultra high performance of current semiconductors. Among these issues, signal integrity test on interconnections must be solved for highly integrated circuits like SoC. In this paper, we propose an effective pattern application method for signal integrity test on interconnects. Proposed method can be applied by using boundary scan architecture and very efficient test can be preceded with pretty short test time.