• Title/Summary/Keyword: roof structure

Search Result 587, Processing Time 0.028 seconds

Effects of vortex generators on the wind load of a flat roof: A computational study

  • Zhao, Yagebai;Deng, Xiaolong;Zhang, Hongfu;Xin, Dabo;Liu, Zhiwen
    • Wind and Structures
    • /
    • v.32 no.1
    • /
    • pp.1-9
    • /
    • 2021
  • Vortex generators are commonly used in mechanical engineering and the aerospace industry to suppress flow separation owing to their advantages of simple structure, economic viability, and high level of efficiency. Owing to the flow separation of the incoming wind on the leading edge, a suction area is formed on the roof surface, which results in a lifting effect on the roof. In this research, vortex generators were installed on the windward surface of a flat roof and used to disturb to roof flow field and reduced suction based on flow control theory. Computational fluid dynamics (CFD) simulations were performed in this study to investigate the effects of vortex generators on reduce suction. It was determined that when the vortex generator was installed on the top of the roof on the windward surface, it had a significant control effect on reduce suction on the roof leading edge. In addition, the influence of parameters such as size, placement interval, and placement position of the vortex generator on the control effect of the roof's suction is also discussed.

Effect of shear wall location in rigid frame on earthquake response of roof structure

  • Ishikawa, Koichiro;Kawasaki, Yoshizo;Tagawa, Kengo
    • Structural Engineering and Mechanics
    • /
    • v.11 no.6
    • /
    • pp.605-616
    • /
    • 2001
  • The purpose of this study is to investigate the effect of the shear wall location in rigid frames on the dynamic behavior of a roof structure due to vertical and horizontal earthquake motions. The study deals with a gabled long span beam supported by two story rigid frames with shear walls. The earthquake response analysis is carried out to study the responses of the roof: vibration mode, natural period, bending moment and horizontal shear force of the bearings. The study results in the following conclusions: First, a large horizontal stiffness difference between the side frames is caused by the shear wall location, which results in a large vertical vibration of the roof and a large shear force at the side bearings. Second, in this case, the seismic design method for ordinary buildings is not useful in determining the distribution of the static equivalent loads for the seismic design of this kind of long span structures.

Analysis of Field Condition for Proper Waterproofing Materials applied to Green Roof System for Depot (도시철도 차량기지의 기반녹화에 적합한 방수시스템 선정을 위한 환경 조건 분석)

  • Min, Kwang-Man;Kwon, Shi-Won;Choi, Sung-Min;Kwak, Kyu-Sung;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2006.11a
    • /
    • pp.127-131
    • /
    • 2006
  • Depot have a lagged behind structure in the side of building up the view. With this reason, people have been recognized depot as hatred facility causes to have car noise, air pollution. In the other hand, depot become a underground and complex facility as a higher-value added building, and moreover, it need to understand the environment that depot structure have a specific field condition to apply green roof system. 1) Analysis proper waterproofing material and root barrier apply to depot need root penetrating test method 2) Suggest root barrier and waterproofing material relate to maintain and construction for green roof system 3) Construction condition for depot have crack movement of structure by vehicle vibration and root penetrating force by plant growth

  • PDF

Booming Noise Reduction of Passenger Cars by Mode Decoupling of Structural-Acoustic Systems (구조-음향 모드 비연성에 의한 차량의 부밍 소음 저감)

  • 고강호;이장무
    • Journal of KSNVE
    • /
    • v.9 no.4
    • /
    • pp.822-827
    • /
    • 1999
  • The reduction of booming noise level and improvement of sound quality in the vehicle interior have been major fields of vehicle NVH for many years. In order to reduce the booming noise this paper proposed a system variable, which takes account of mode shapes and natural frequencies of the structural-acoustic system, measurement points and excitation frequency. By simplifying the system variable, the major contributors of panels inculding roof, roof lining, wind shield glasses, doors and floor to booming noise at a specific frequency was experimentally found. Also the relationships between structural modes of roof lining, one of the major contributors, and acoustic modes of compartment cavity were investigated from the viewpoint fo structure-borne noise. In addition, the roof lining was modified structurally by applying marble sponge to the gap between roof and roof lining. Asthe result of structural modification, the booming noise was reduce at target frequency.

  • PDF

Pitched Roof-Building Integrated Wind Turbine System Performance Estimation (건물 지붕 구조를 활용한 건물일체형 풍력발전시스템의 성능 예측)

  • Choi, Hyung-Sik;Chang, Ho-Nam
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.324-327
    • /
    • 2008
  • We simulated the performance improvement of a wind turbine installed on the pitched roof-building(apartment in urban area, 50m height). A nozzle shape wind guide is added on the roof of a model apartment. The nozzle-diifuser structure effects for the free stream wind (average 4m/s, 50m height in Incheon) is studied by a basic CFD analysis. This paper examines the effects of roof structure on the wind velocity and the wind distortion effects by a front building. The possible wind power generation capacity on building roof in urban is calculated.

  • PDF

Active Vibration Control of An Automotive Roof using Piezoelectric Sensor and Actuator (압전재료 센서 액츄에이터를 이용한 자동차루프의 능동진동제어)

  • Moon, Sung-Jin;Kim, Chan-Mook;Kang, Young-Kyu
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.834-839
    • /
    • 2004
  • In this paper, we have studied on the active vibration control of an automotive roof in passenger car's structure using piezoelectric material as the actuator and sensor attached on the surface of the automotive roof, As a control algorithm, negative velocity feedback control method is used in the study and the position of the sensor is almost attached on the nearest position of maximum normal stresses occurring while the roof is vibrating due to disturbance or exciting, Also, the actuator is attached on the other side mostly collocated to the sensor. The optimum positions have the maximum stresses of the roof which have been found in the result of the finite element analysis using Nastran software, As the fundamental experiments, a beam and plate have also been implemented to verify the performance of vibration suppression. Finally the experiment of the roof has been carried out and The roof experiment has just given a possibility to an active vibration control of the automotive structure still not applied for passenger cars.

  • PDF

A Study on the Acceptance of Western timber structure and the Interior space of Church buildings in the early modern period in Korea - Focused on the roof structure of church architecture in the Flowering and Japanese occupation period - (한국 근대초기 서양 목구조의 수용과 교회 내부공간형태에 관한 연구 - 개화기와 일제강점기 교회건축의 지붕틀 구조를 중심으로 -)

  • Kim Jung-Shin
    • Korean Institute of Interior Design Journal
    • /
    • v.14 no.5 s.52
    • /
    • pp.10-17
    • /
    • 2005
  • This Study is concerned with the acceptance of Western timber structure and the interior space of church buildings in the early modern period in Korea. Timber roofs have represented a wide variety of constructional forms and have been fundamental to any technological appraisal of the evolution of both of Western and Eastern architecture. Especially the roof structure of the church buildings reflects the technological level, aesthetic sense, and spacial concepts of the age. Between Western timber structure and Korean timber structure, there are many differences in not only structural form but also form of roof, members, load, frame system and etc. And there were various types of framing technique such as timber truss, timber arch, timber vault in the western style church architecture in the early modern period in Korea. I have summarized the character of the acceptance process of Western timber structure and the influences on the interior space of church buildings.

A Study on the 'Perpendicular crossing Dori(Purlin)' Structure of the Ddeulzip(Courthouse) in Andong Cultural Area (안동문화권(安東文化圈) 뜰집의 '직교(直交)도리' 구조(構造)에 관한 연구(硏究))

  • Kim, Hwa-Bong
    • Journal of architectural history
    • /
    • v.9 no.2 s.23
    • /
    • pp.7-17
    • /
    • 2000
  • The purpose of this study is the analysis of 'perpendicular crossing Dori' with a structural character of Ddeulzip in Andong cultural area. There are many structural methods to solve the problems of Ddeuljip which is connected space in the rectangular type. There are 'Slope Base', 'Woosangak' roof, 'Seosangak' roof, and '4 beam roof framing' Moreover, they have been used 'perpendicular crossing Dori'. Its characters are as follows ; 1. The 'perpendicular crossing Dori' structure is occurred in different depth of width and length space of 'ㄱ' typed plan. At that time the beam of width is crossed in the middle of the beam of length without the order under them. 2. The 'perpendicular crossing Dori' structure is the method of free depth of width in regular distance of column which is different from general usage of balcony order. 3. The 'perpendicular crossing Dori' structure is founded north-western area of Andong Cultural Area(Bonghwa, Andong, Youngju, and Yeacheun). The best old sample was in Andong(16C) and the next is Yeacheun(17C) and the last is Bonghwa(18C). 4. The frequency in use of roof type of 'perpendicular crossing Dori' structure is 64% of 'Seosangak' and 36% of 'Woosangak'. The sample of 'Woosangak' house of 'perpendicular crossing Dori' structure is concentrated in Bonghwa. 5. The best merit of the 'perpendicular crossing Dori' structure is usage of double swing window in front of Anbang, It is the spacial success which overcomes the structural limits. And it is the structural rationality.

  • PDF

Analysis of Wind Pressure Coefficient for Spatial Structure Roofs by Wind Load Standards and Wind Tunnel Tests (국가별 풍하중 기준과 풍동실험에 따른 대공간 구조물 지붕의 풍압계수 분석)

  • Cheon, Dong-jin;Yoon, Sung-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.17 no.4
    • /
    • pp.103-113
    • /
    • 2017
  • Spatial Structure has suffered from a lot of damage due to the use of lightweight roofs. Among them, the damage caused by strong winds was the greatest, and the failure of the calculation of the wind load was the most frequent cause. It provides that wind tunnel test is used to calculate the wind load. However, it is often the case that the wind load is calculated based on the standard of wind load in the development design stage. Therefore based on this, the structure type and structural system and member design are often determined. Spatial structure is usually open at a certain area. The retractable roof structure should be operated with the open roof in some cases, so the wind load for the open shape should be considered, but it is not clear on the basis of the wind load standard. In this paper, the design wind pressure of a closed and retractable roof structure is calculated by KBC2016, AIJ2004, ASCE7-10, EN2005, and the applicability of wind pressure coefficient is compared with wind tunnel test.

Analysis and Experiment on dynamic characteristics of a Carbon Fiber Reinforced Composite Automotive Roof (탄소섬유 복합재로 된 자동차 루프에 대한 동특성 해석 및 실험)

  • 제형호;진용선;김찬묵;강영규;사종성
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.330-335
    • /
    • 2003
  • Analysis and experiment on dynamic characteristics of automotive roof have been carried out experimentally and numerically to design a lightweight roof. Finite element analysis of a conventional steel automotive roof was verified by experiments on vibration characteristics. The dynamic analysis of carbon fiber reinforced composite automotive roof shows that the roof stiffness changes as the fiber orientation of the laminated panel changes. Optimization results yielded a composite roof, which was 52% lighter, than the steel conventional steel automotive roof. This paper addresses a design strategy of composite roof for weight reduction.

  • PDF