• Title/Summary/Keyword: repellent

Search Result 334, Processing Time 0.03 seconds

An Experimental Study on the Water Repellent Property of Mortar Applied Water Repellent Agent of Inorganic Polymer Type (무기질 폴리머계 흡수방지재를 도포한 모르터의 발수성능 평가에 관한 실험적 연구)

  • 이일형;엄덕준;오상근
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2004.05a
    • /
    • pp.33-37
    • /
    • 2004
  • Recently, Growing tendency for structure surface to use water repellent agent has increased steadily. But investigation of it's protection and durability property is not sufficient. Therefore, this paper shows the investigation about repellent property and micro structure's change in surface layer of mortar that is applied by water repellent agent. Water repellent property, absorption coefficient, air permeability, porosity and observation of micro construct was investigated according to water repellent agent type. The test results indicated that mortar applied water repellent agent appears tiny absorption coefficient, but air permeability is maintained. The reason is because silane solution is coating at capillary surface of a wall and minute pore structure is changeless.

  • PDF

An Experimental Study on the Water Repellent Property of Mortar Applied Water Repellent Agent of Inorganic Polymer Type (무기질 폴리머계 흡수방지재를 도포한 모르터의 발수성능 평가에 관한 실험적 연구)

  • 김영삼;양승도;유재강;오상근
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2002.05a
    • /
    • pp.31-36
    • /
    • 2002
  • Recently, more interests in surface treatment of structure with water repellent agent are steadily increased, But, investigation of its properties such as protection, durability, morphology of micro structure is not sufficient. Therefore, This paper is aimed for the investigation of water repellent property and change of morphology of micro pores in mortar that is treated by water repellent agent(Inorganic polymer based material). Water repellent property, water absorption coefficient, air permeability, porosity and the observation of micro structure was investigated in different water repellent agent type. The test results indicated that water repellent treated mortar showed low absorption coefficient and air permeability(breathing effect). This is why inorganic polymer is coated at the wall of capillary and micro pores, also, the volume of micro pore is reduced without the change of morphology in micro structure.

  • PDF

Compressive Strength and Absorption Ratio of Mortar Replaced with Coated Spent Coffee Grounds by Type of Water Repellent (발수제 종류에 따른 코팅된 커피찌꺼기를 치환한 모르타르의 압축강도 및 흡수율)

  • Choi, Byung-Cheol;Kim, Gyu-Yong;Pyeon, Su-Jeong;Ji, Sung-Jun;Lee, Yae-Chan;Nam, Jeong-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.63-64
    • /
    • 2023
  • In order to reduce the high absorption ratio of spent coffee grounds, this study examined the compressive strength and absorption ratio of mortar replacing coated spent coffee grounds according to the type of water repellent. In order to examine this, as the water repellent used, a silane-based water repellent (fluorine-based water repellent) and an acrylic-based water repellent, which are film-type water repellents, and a silane/siloxane-based water repellent, which are penetration-type water repellents, were used. The spent coffee grounds were coated with each of three water repellents, and mortar was prepared by mixing cement and fine aggregate. As a result of the experiment, the compressive strength and absorption ratio of the mortar replaced with coated spent coffee grounds coated with the film-type water repellent were superior to the penetration-type water repellent. Therefore, in order to reduce the high absorption ratio of spent coffee grounds, a suitable water repellent is a film-type water repellent. Among them, it is judged that the acrylic type has excellent water repellency and is suitable.

  • PDF

An Experimental Study on Physical Properties and Water Repellent Performance of Cement Mortar According to Mixing Method of Water Repellent (발수제 혼입 방법에 따른 시멘트 모르타르의 물리적 특성 및 발수 성능에 관한 실험적 연구)

  • Kim, Wan-Su;Yang, Hyun-Min;Kim, Yeung-Kwan;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.05a
    • /
    • pp.99-100
    • /
    • 2019
  • Water repellent and waterproofing agents fail to act work properly if cracks or detachment occurs outside. The method of making mortar was tested by classifying it into two methods: direct water-repellent put in concrete and water-repellent spray to sand method. It was found that the compressive strength was decreased as the amount of water repellent was increased. As a result of measuring the contact angle, all of the specimens were hydrophobic. The spray method showed greater water repellent effect than the direct mixing method.

  • PDF

A Study on the Deicing Performance of Cement Mortar through the Addition of Water-repellent (발수제 혼입에 따른 시멘트 모르타르의 표면 얼음 제거성능에 관한 연구)

  • Kang, Suk-Pyo;Hong, Seong-Uk;In, Byung-Eun;Kim, Sang-Jin
    • Journal of the Korea Institute of Building Construction
    • /
    • v.22 no.6
    • /
    • pp.597-606
    • /
    • 2022
  • This paper examined the effect of water repellent type and addition among various factors on the deicing performance of cement mortar surface according to incorporation. As a result, the compressive strength of the water repellentcement mortar compared to the cement mortar, and the compressive strength of the oligomer-based water repellent mortar was higher than that of the monomer-based water repellent. The contact angle of the water-repellent mortar was increased compared to the additive mortar, and the oligomer water-repellent agent compared to the monomer-based water-repellent. As a result of measuring the ice formation time of cement mortar due to the mixing of the water repellent, the ice formation was delayed until 25 minutes for mortar to which the water repellent was added. the measurement of the ice attachment load mortar without water repellent with water repellentwhen the water repellent was added to mortar, deicing performance was increased.

Flame-Retardant and Water-Repellent Finishing of Automobile Indoor Fabrics (자동차 내장용 직물의 난연 및 발수가공)

  • 박병기;이방원;김환철;김학용
    • Textile Coloration and Finishing
    • /
    • v.11 no.5
    • /
    • pp.7-12
    • /
    • 1999
  • The objective of this study is to apply water repellent and flame retardant finishes simultaneously to the fabric used for automobile. Both two step and one step methods were tried to apply the finishing agent to the fabric. In the two step method, water repellent agent was treated first, and flame retardant agent was applied next. The reverse finishing process was also attempted. In the one step method, flame retardant agent and water repellent agent treated to the fabric in one bath. The results of two step method revealed that the finishing effect was better when the water repellent agent was treated first than when flame retardant agent was treated first. In one step method, fluoro water repellent agent was superior to silicon water repellent agent.

  • PDF

Durable Water and Oil Repellent Finish of Wool Fabric(I) (양모직물의 내구성 발수 및 발유가공(I))

  • 나도춘;정순량;박병기;정경락
    • Textile Coloration and Finishing
    • /
    • v.10 no.1
    • /
    • pp.33-37
    • /
    • 1998
  • It is rather important in the water and oil repellent finishing for wool fabric what kind of water-repellent agents will be used. In many cases, Fluorocarbon-based water-repellent agents(eg.Oleophobol-S), the surface tensions of which very low, were recom-mended on account of good water and oil repellencies. In repellent finishing, fabrics were padded in a bath which contained aqueous solution of water-repellent agents, and wetting agents, followed by drying and curing. The most suitable treating condition for excellent repellency was as follows Fabrics were padded at liquor pick-up ratio of 50%, with aqueous solution which contained $30g/\ell$ of water-repellent agents, and $40g/\ell$ of wetting agents. And the padded fabrics were dried at $110^\circ{C}$ for 1 minute, and cured at $160^\circ{C}$ for 2 minutes. For the fabrics, water and oil repellencies and durability to repeated dry-cleanings are observed.

  • PDF

Development of Rodent Repellent Cable With High Stability (고안정성을 가진 방서 케이블의 개발)

  • Yang, W.Y.;Kang, T.O.;Kim, K.S.;Chun, C.O.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1354-1356
    • /
    • 1994
  • In order to protect cable from rat's biting, a development of rodent repellent is described. This cable has double coated sheath such as construction of skin layer over the conventional cable sheath. Stabilized rodent repellent agent which has good compatibility with PVC is employed in a skin layer. Rodent repellent layer has highly residual properties of agent through the manufacturing process, and meets the general requirements of cable sheath. Also, rat repellent effect is excellent.

  • PDF

Material Properties Evaluation of Cement Mortar Mixed with Organic/Inorganic Combined Water-repellent (유/무기 복합 발수제를 혼입한 모르타르의 재료특성 평가)

  • Kim, Wan-Su;Yoon, Chang-Bok;Cho, In-Sung;Lee, Han-Seung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.6
    • /
    • pp.50-58
    • /
    • 2020
  • When the concrete surface layer is damaged, The method of impregnating the concrete surface with a water repellent cannot secure the expected durability. Recently, various waterproofing and water-repellent materials were mixed into concrete or mortar to secure water repellency even inside cracks, but compressive strength was greatly reduced. In order to overcome the decrease in compressive strength, there has not yet been a study using the merits of organic and inorganic materials at the same time, so in this study, the physical properties and water repellency performance were evaluated by mixing an organic/inorganic composite water repellent appropriately mixed with an organic and inorganic material into the mortar. When mixed with organic/inorganic water repellent, the flow and air content were reduced by about 10% and 50% compared to the Liquid specimen. In the case of the P6L1 specimen, it was confirmed that the compressive strength decreased by about 3.5% compared to the non-mixed mortar at 39.5 MPa, the same as the existing water repellent, Powder. Water-repellent performance The organic-inorganic composite water repellent mixture specimen confirmed higher water repellency than the existing water repellent mixture powder, and the chloride penetration resistance evaluation result showed that the organic-inorganic composite water repellent mixture specimen reduced the passing charge by about 45% compared to the non-mixed mortar. In summary, it is judged that the P5L1 organic/inorganic composite water repellent mixed with a powder water repellent and a liquid water repellent in a ratio of 5:1 is the most reasonable to prevent the decrease in compressive strength and secure water repellency.

Status and Prospect of Test Methods of Quality Silicone Water Repellent for Protecting Reinforced Concrete

  • Sun, H.Y.;Yuan, Z.Y.;Yang, Z.;Shan, G.L.;Shen, M.X.
    • Corrosion Science and Technology
    • /
    • v.16 no.3
    • /
    • pp.141-150
    • /
    • 2017
  • Impregnating with quality silicone water repellent on the concrete surface is an effective method of protecting concrete. Quality silicone water repellent has been widely used in the engineering profession because of its desirable properties such as hydrophobicity, keeping concrete breathable and preserving the original appearance of the concrete. The companies in China that produce silicone water repellent are listed. Test methods in the specifications or standards about silicone water repellent in China are summed. The test methods relative to durability of concrete impregnated with silicone water repellent (such as resistant to chloride ion penetration, resistant to alkali, resistance to freezing and thawing and weatherability etc.) and the constructive quality (such as water absorption rate, impregnating depth and the dry velocity coefficient etc.) are compared and analyzed. The results indicate that there are differences among test methods relative to different specifications with the same index and therefore, confusion has ensued when selecting test methods. All test methods with the exception of the method of water absorption rate by using a Karsten flask are not non-destructive methods or conducted in a laboratory. Finally, further research on silicone water repellent during application is proposed.