• 제목/요약/키워드: reference range

검색결과 1,777건 처리시간 0.031초

주관절의 정형 물리치료 (Elbow Orthopaedic Physical Therapy)

  • 박지환
    • 대한정형도수물리치료학회지
    • /
    • 제1권1호
    • /
    • pp.65-74
    • /
    • 1995
  • There is no line of demarcation between the shoulder and elbow regions. Pain In the arm may originate at the shoulder with reference downwards or less often at the elbow with reference upwards. Most pains indicated by the patient at the elbow or forearm have a local origin, since at the more distal part of the upper limb the capacity for correct localization is good. Once it is clear that the elbow region is at fault, the joint and the muscles about it are tested by ten movements. 1. Four. Passive extension, flexion, pronation, supination-full range, LOM, painful, painless. 2. Four. Resisted extension, flexion, pronation, supination-strong, weak, painful, painless. 3. Two. Resisted flexion, extension at the wrist-painful, painless. The muscles that perform theses two movements arise from the humeral epicondyles and a lesion in either often causes pain felt at the elbow although the tissuse affected is not functionally a part of the elbow (i. e. Tennis elbow and Golfer's elbow).

  • PDF

비동기 샘플링에 의한 전력과 에너지 측정 기준시스템 (Electrical Power and Energy Reference Measurement System with Asynchronous Sampling)

  • 위제싱허;박영태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.684_685
    • /
    • 2009
  • A digital sampling algorithm that uses a two high resolution integrating Voltmeters which are synchronized by Phase Lock Loop (PLL) time clock for accurately measuring the parameters, active and reactive power, for sinusoidal power measurements is presented. The PLL technique provides high precision measurements, root mean square (rms), phase and complex voltage ratio, of the AC signal. The system has been designed to be used at the Korean Research Institute of Standards and Science (KRISS) as a reference power standard for electrical power calibrations. The test results have shown that the accuracy of the measurements is better than $10 {\mu}W/VA$ and the level of uncertainty is valid for the power factor range zero to 1 for both lead and lag conditions. The system is fully automated and allows power measurements and calibration of high precision wattmeters and power calibrators at the main power frequencies 50 and 60 Hz.

  • PDF

책임있는 엔지니어를 위한 STS 교육의 몇 가지 쟁점 (A Few Issues in the STS Education for Responsible Engineers)

  • 이상욱
    • 공학교육연구
    • /
    • 제15권1호
    • /
    • pp.79-83
    • /
    • 2012
  • I argue that STS education for engineers, despite its prima facie usefulness in demystifying the conventional image of science and technology, should deal with a few challenges in order to cultivate 'responsible' engineers. The challenges come from the fact that there are more than one legitimate way of understanding 'responsible' in the engineering contexts depending on how wide the range of responsibility is intended and on how the relevant reference class is defined. In order to tackle these issues, I suggest that we should take into account more seriously the 'value-laden' nature of the engineering design.

Deformable image registration in radiation therapy

  • Oh, Seungjong;Kim, Siyong
    • Radiation Oncology Journal
    • /
    • 제35권2호
    • /
    • pp.101-111
    • /
    • 2017
  • The number of imaging data sets has significantly increased during radiation treatment after introducing a diverse range of advanced techniques into the field of radiation oncology. As a consequence, there have been many studies proposing meaningful applications of imaging data set use. These applications commonly require a method to align the data sets at a reference. Deformable image registration (DIR) is a process which satisfies this requirement by locally registering image data sets into a reference image set. DIR identifies the spatial correspondence in order to minimize the differences between two or among multiple sets of images. This article describes clinical applications, validation, and algorithms of DIR techniques. Applications of DIR in radiation treatment include dose accumulation, mathematical modeling, automatic segmentation, and functional imaging. Validation methods discussed are based on anatomical landmarks, physical phantoms, digital phantoms, and per application purpose. DIR algorithms are also briefly reviewed with respect to two algorithmic components: similarity index and deformation models.

Flow-channel과 microsensor를 내장한 전해질 측정용 소형 카트리지 제작 (Fabricationof small size catridge for electrolyte measurement including flow-channel and microsensors)

  • 이영철;조병욱;김창수;고광락;손병기
    • 전자공학회논문지D
    • /
    • 제35D권4호
    • /
    • pp.78-83
    • /
    • 1998
  • A small size cartrideg for FET type electrolyte sensor is designed and faricated with much simplified process by using micromachining tenchiques such as silicon etching andglass bonding. Size of the whole cartideg is 2.4cm*2.5cm, and the dead volume of a micro flow-channel in the cartrideg is only 8.5.mu.l. The photosensitive polymer(THB 30) is used to define a micropool and to encapsulate the sensor surface for standardizationof electrolyte sensors. To miniaturize micro flow-channel conventional reference electrode(Ag/AgCl) a differential amplification is introduced using REFET and quasi reference electrode. Refet was fabricated using photosensitive polymer(OMR 83). The fabricated cartridge with built-in pH-ISFET showed good operational characteristics such as linearity and high sensitivity (55.4mV/pH) in a wide pH range(pH2-pH12).

  • PDF

초음파센서를 이용한 자율 이동로봇의 위치추적 (Localization of an Autonomous Mobile Robot Using Ultrasonic Sensor Data)

  • 최창혁;송재복;김문상
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2000년도 추계학술대회 논문집
    • /
    • pp.666-669
    • /
    • 2000
  • Localization is the process of aligning the robot's local coordinates with the global coordinates of a map. A mobile robot's location is basically computed by a dead reckoning scheme, but this position information becomes increasingly inaccurate during navigation due to odometry errors. In this paper, the method of building a map of a robot's environment using ultrasonic sensor data and the occupancy grid map scheme is briefly presented. Then, the search and matching algorithms to compensate for the odometry error by comparing the local map with the reference map are proposed and verified by experiments. It is shown that the compensated error is not accumulated and exists within the limited range.

  • PDF

PWM 인버터의 전압 이용률 개선 (Improvement of Voltage Utilization in PWM Inverters)

  • 이지명;이동춘
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 추계학술대회 논문집 학회본부
    • /
    • pp.518-520
    • /
    • 1997
  • In a space vector PWM inverter, the dc input voltage is utilized to the maximum by an overmodulation technique, which is derived from Fourier series expansion of the reference phase voltage. Data angles such reference angle and holding angle are piecewise-linearized for on-line control. Harmonic components and THD of the output voltage are also analyzed. For disturbance of the dc input voltage, a smooth transition is obtained from a linear range to the six-step mode by the control angle change.

  • PDF

소음원 영상화를 위한 마이크로폰 배열 설계 (Microphone Array Design for Noise Source Imaging)

  • 윤종락
    • 소음진동
    • /
    • 제7권2호
    • /
    • pp.255-260
    • /
    • 1997
  • This paper describes 3-dimensional volume array of 4 microphones including a reference microphone which is capable of imaging wideband noise source position in 2-dimensional image plane. The cross correlation function and corresponding imaging function between a reference microphone and other microphone, are derived as a function of noise source position. The magnitude of the imaging function gives noise source mapping in image plane. Since the image plane is selective from a rectangular and a cylindrical plane, noise source position information such as range and bearing relative to the array is identified very much easily. Simulation results for typical source configurations confirms the applicability of the proposed array in noise control field.

  • PDF

ISFET 및 pt 기준전극과 차동증폭법을 이용한 요소감지소자 개발 (Development of urea sensor using the ISFET and Platinum reference electrode and by employing the differential amplification)

  • 김성진;권대혁;이종현;손병기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 전기.전자공학 학술대회 논문집
    • /
    • pp.356-359
    • /
    • 1988
  • An FET type urea sensing device has been developed using the ISFET and platinum reference electrode and by employing the differential amplification. The performance characteristics of the fabricated sensor show a good linearity in the urea concentration range of $5{\times}10^{-5}$ to $10^{-3}$g/ml and a stable response.

  • PDF

클램프 형 직교류 저 전류 측정 센서 (A Clamp Type Sensor for AC/DC Low Current Measurement)

  • 박영태;유광민
    • 한국전기전자재료학회논문지
    • /
    • 제15권12호
    • /
    • pp.1045-1053
    • /
    • 2002
  • This paper describes characteristics of the developed current sensor by means of two identically wound magnetic cores forming a clamp like for measurement of a low DC, or AC current. This sensor consists of peak value detectors, a sensor of an electrically compensated current transformer type, a reference alternating voltage, Precision measuring circuits to measure the output signals of sensor with harmonics, and can be measured up to 2 A at DC, or AC current. The current sensor shows a measurement accuracy of less than 0.3% in the frequency range 40 Hz - 10 HBz. The resolution and sensitivity of the sensor were evaluated 0.1 mA and 10 mV/mA, respectively.