• 제목/요약/키워드: rectangular TLD

검색결과 9건 처리시간 0.214초

사각형 동조 액체 감쇄장치(TLD)에서 조절하중의 수치적 산정 (Numerical Evaluation of Control Force in Rectangular Tuned Liquid Damper)

  • 정일영;황종국
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1995년도 가을 학술발표회 논문집
    • /
    • pp.250-257
    • /
    • 1995
  • The properties of Tuned Liquid Damper are investigated theoretically. In this study, numerical model is a nonlinear model for a rectangular TLD under horizontal motion on the basis of the shallow water wave theory, where the damping of the liquid motion is included semianalytically. For TLD subjected to harmonic external force, the liquid motion of TLD is simulated. Analysis result is showed that liquid motion in TLD is strongli nonlinear even under small excitation.

  • PDF

Shaking table tests on a SDOF structure with cylindrical and rectangular TLDs having rotatable baffles

  • Zahrai, Seyed Mehdi;Kakouei, Sirous
    • Smart Structures and Systems
    • /
    • 제24권3호
    • /
    • pp.391-401
    • /
    • 2019
  • Control of vibrations against extraordinary excitations such as wind and earthquake is very important to the protection of life and financial concerns. One of the methods of structural control is to use Tuned Liquid Damper (TLD), however due to the nature of TLD only one sloshing frequency can be created when the water is sloshing. Among various ideas proposed to compensate this problem, by changing the angle of some rotatable baffles embedded inside a TLD, a frequency range is created such that these baffles are tuned manually at different frequencies. In this study, the effect of cross sectional shape of container with rotating baffles on seismic behavior of TLD is experimentally studied. For this purpose, rectangular and cylindrical containers are designed and used to suppress the vibrations of a Single Degree-Of-Freedom (SDOF) structure under harmonic and earthquake excitations considering three baffle angles. The results show that the rectangular-shaped damper reduces the structural response in all load cases more than the damper with a cylindrical shape, such that maximum differences of two dampers to reduce the structural displacement and structural acceleration are 5.5% and 3% respectively, when compared to the cases where no baffles are employed.

진동대를 이용한 TLD와 MTLD의 성능실험에 대한 분석 (An Analysis on Performance Test of TLD and MTLD Using Shaking Table)

  • 유장열;송창현;유기표;김영문
    • 한국공간구조학회:학술대회논문집
    • /
    • 한국공간구조학회 2008년도 춘계 학술발표회 논문집
    • /
    • pp.139-144
    • /
    • 2008
  • 본 논문은 건물의 형태와 동적특성을 변화시키지 않고 건물에 부가질량을 설치하여 건물의 진동을 제어하는 방법중 수동형 제진장치인 TLD(tuned liquid damper)와 MTLD(multiple tuned liquid damper)의 진동응답을 감소시키기 위해 진동대를 이용한 성능실험을 실시하였다. 따라서 기존의 형태별(원형, 직사각형) TLD 실험의 실험 데이터를 가지고 가진 진폭(1mm, 3mm, 5mm, 10mm, 20mm) 의 변화에 따른 고유진동수(0.44Hz, 0.55Hz)에 대한 MTLD의 형태별 실험을 통하여 TLD와 MTLD의 진동감소효과에 대한 성능실험을 비교 분석 하였다.

  • PDF

내부 슬로싱 현상을 이용한 사각상자 형태의 부유체 Sway 거동 모사에 대한 수치적 고찰 (Numerical study of sway motion of a rectangular floating body with inner sloshing phenomena)

  • 하민호;정철웅
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2013년도 춘계학술대회 논문집
    • /
    • pp.161-165
    • /
    • 2013
  • In this paper, possibility of controlling motion of a floating structure using a tuned liquid damper (TLD) is numerically investigated. A TLD is a tank partially filled with liquid. Sloshing phenomena of liquid inside a tank can suppress movement of the tank subject to external excitations at specific frequency. The effects of sloshing phenomena inside a rectangular floating body on its sway motion are investigated by varying excitation frequency. First, a grid-refinement study is carried out to ensure validity of grid independent numerical solutions using present numerical techniques. Then, sway motion of the floating body subjected to wave with five different frequencies are simulated. The normalized amplitudes of sway motion of the target floating body are compared over the frequency, for cases with and without water inside the floating body. It is shown that the motion of the floating body can be minimized by matching the sloshing natural frequency to excitation frequency.

  • PDF

The Vibration Performance Experiment of Tuned Liquid Damper and Tuned Liquid Column Damper

  • Kim Young-Moon;You Ki-Pyo;Cho Ji-Eun;Hong Dong-Pyo
    • Journal of Mechanical Science and Technology
    • /
    • 제20권6호
    • /
    • pp.795-805
    • /
    • 2006
  • Tuned Liquid damper and Tuned Liquid Column are kind of passive mechanical damper which relies on the sloshing of liquid in a rigid tank for suppressing structural vibrations. TLD and TLCD are attributable to several potential advantages - low costs ; easy to install in existing structures : effective even for small-amplitude vibrations. In this paper, the shaking table experiments were conducted to investigate the characteristics of water sloshing motion in TLD (rectangular, circular) and TLCD. The parameter obtained from the experiments were wave height, base shear force and energy dissipation. The shaking table experiments show that the liquid sloshing relies on amplitude of shaking table and frequency of tank. The TLCD was more effective control vibration than TLD.

내부 슬로싱 현상에 따른 사각상자 형태의 부유체 서지 거동에 대한 수치적 고찰 (Numerical Investigation on Surge Motion of a Rectangular Floating Body due to Inner Sloshing Phenomena)

  • 하민호;정철웅
    • 한국소음진동공학회논문집
    • /
    • 제23권7호
    • /
    • pp.662-668
    • /
    • 2013
  • In this paper, possibility of controlling motion of a floating structure using a tuned liquid damper (TLD) is numerically investigated. A TLD is a tank partially filled with liquid. Sloshing motion of liquid inside a tank is known to suppress movement of the tank subject to external excitations at specific frequency. The effects of sloshing phenomena inside a rectangular floating body on its surge motion are investigated by varying external excitation frequency. First, a grid-refinement study is carried out to ensure validity of grid independent numerical solutions using present numerical techniques. Then, surge motion of the floating body subjected to external wave is simulated for five different excitation frequencies of which the center frequency equals to the natural frequency of internal liquid sloshing. The normalized amplitudes of surge motion of the target floating body are compared according to the excitation frequency, for the cases with and without water inside the floating body. It is shown that the motion of the floating body can be minimized by matching the sloshing natural frequency to the excitation frequency.

전악 치근단 방사선사진 촬영시 촬영조건에 따른 흡수선량 변화에 대한 연구 (COMPARISON OF ABSORBED DOSES RESULTING FROM VARIOUS INTRAORAL PERIAPICAL RADIOGRAPHY)

  • 강미애;박태원
    • 치과방사선
    • /
    • 제25권2호
    • /
    • pp.297-308
    • /
    • 1995
  • This study was designed to measure the absorbed dose to organs of special interest from full mouth with intraoral film(l4 films) and to compare the five periapical techniques. Thermoluminescent crystals(TLD-100 chip) were located in brain, orbit, bone marrow of mandibular ramus, bone marrow of mandibular body, bone marrow of 4th cervical spine, parotid gland, submandibular gland and thyroid gland. X -ray machine was operated at 70kVp and round collimating film holding device(XCP) and rectangular collimating film holding device(Precision Instrument) were used. The distance from the X-ray focus to the open end of the collimator was 8 inch, 12 inch and 16 inch. The results were as follows : 1. The absorbed dose was the highest in bone marrow of mandibular body(5.656mGy) and the lowest in brain (0.050mGy). 2. Generally, the lowest absorbed dose was measured from 16 inch cylinder, rectangular collimating film holding device with paralleling technique. But, in bone marrow of mandibular body and the floor of mouth, the highest absorbed dose was measured from 12 inch cylinder, rectangular collimating film holding device with paralleling techniques. 3. Comparing of five intraoral radiographic techniques, it was appeared statistically significant reduction of the absorbed doses measured with rectangular collimating film holding device compared to XCP film holding device (P<0.05). 4. No statistically significant reduction in the absorbed dose was found as cylinder length was changed(P>0.05).

  • PDF

저주파수 하의 TLCD 시스템의 오리피스 형상 효과 (Orifice shape effect of the TLCD system under a low frequency)

  • 임희창
    • 한국가시화정보학회지
    • /
    • 제12권1호
    • /
    • pp.30-34
    • /
    • 2014
  • Bluff bodies under the external periodic force vibrate at their own natural or forced frequency. Rectangular bodies or similar structures such as high-rise towers and apartments, and recently a well-cited application - offshore floating bodies, usually needs to reduce these vibrations for stability and the mode control. Therefore, this study is aiming to reduce or control the vibration of a structure by a passive control method, i.e., TLCD (Tuned Liquid Column Damper). Controlling a moving body with a TLCD based on a variety of the orifice shape has been preliminary studied. In order to get a proper control, an optimized study is made on the design of the orifice shape, which has internal plates with the holes. The results show the force acting on the body due to the periodic movement highly depends on the number of holes on the plate and the height of the water level. Therefore, the optimum shape of the orifice and the height of the water level should be confirmed by a series of experiments.

고 에너지 방사선치료에서 환자의 피폭선량 분포와 생식선의 차폐 (Shielding for Critical Organs and Radiation Exposure Dose Distribution in Patients with High Energy Radiotherapy)

  • 추성실;서창옥;김귀언
    • Journal of Radiation Protection and Research
    • /
    • 제27권1호
    • /
    • pp.1-10
    • /
    • 2002
  • 의료용 선형가속기에서 발생되는 고 에너지 광자선은 콜리메이터에 의하여 누출되며 치료두부(head), 콜리메이터, 환자를 포함한 치료실내의 모든 벽과 구성 물질들에 의하여 많은 산란선이 발생된다. 방사선치료는 종양에 따라서 최소한 40 Gy에서 80 Gy까지 조사되기 때문에 주위건강조직 특히 생식가능한 사람에 대한 생식선의 피폭선량을 평가하여야하며 종양치료에 영향을 주지 않은 범위에서 가능한 방법을 동원하여 피폭선량을 줄여야한다. 방사선 안전관리등의 기술기준에 관한 규칙(과학기술부령 제17호) 제3절 의료분야의 특별기준, 제44조(진료환자의 방사선 피폭)에 의하면 진료를 위한 환자 피폭선량을 합리적으로 달성 가능한 최소의 수준으로 유지하기 위한 절차를 구비하여야 하며 과학기술부 장관은 이에 준하는 의료시설 및 장비취급의 기술기준을 정하고 고시하여야한다고 명시 되어있다. 고 에너지방사선은 악성종양환자들의 치료성과를 향상시키는 동시에 치료후 방사선에 의한 만성효과가 발생 될 수 있기 때문에 주선속의 다양한 산란선과 누출선의 선질변화와 선량을 측정하고 생식선과 같은 주요장기를 산란선으로부터 차폐할 수 있는 기구를 제작 사용함으로서 방사선 피폭선량을 최대한으로 감소시킬 수 있었다. 고 에너지 방사선은 의료용 선형가속기(CLINAC 2100C/D. 2100C. 600C)에서 발생시킨 4, 6, 10 MV x-ray와 코발트원격치료장치(ALCYON II)의 코발트선원에서 방출되는 1.25 MV의 감마선을 이용하였다. 선량측정은 폴리스틸렌과 인체팬텀(Rando)사용하였으며 측정기는 이온함, TLD 및 필름을 사용하였다. 고 에너지 방사선에 의한 산란선은 장치의 콜리메이터 뿐만 아니라 치료실 벽 인체내부등 모든 방향에서 방사됨으로 납 벽돌에 의한 차폐율측정은 많은 변수를 가졌으며 고환인 경우에는 3면이 모두 차폐되도록 항아리모양으로 제작하였다. 태아인 경우 태아가 위치하고 있는 골반위에 육교모양의 선반을 만들고 그 위에 납 벽돌을 장치하도록 고안하였다. Co-60 감마선, 4 MV x-선, 10 MV x-선에서 발생되는 누출선량과 산란선량에 의한 평균 피폭선량은 조사면 중심으로부터 10, 30, 60cm 거리에서 조사면내 최대선량에 대하여 각각 $10^{-2},\;10^{-3},\;10^{-4}$의 비율로 측정되었으며 거리에 따라 지수함수로 줄어들었다. 흉부에 국한된 종양을 10 MV x-ray, $12{\times}12 cm^2$ 조사면으로 치료하였을 때 자궁에 받는 피폭선량은 0.9 mGy/Gy이며 고환이 받는 피폭선량은 0.6 mGy/Gy 이었으며 체장과 신장은 각각 4.8 mGy/Gy 와 2.5 mGy/Gy이다 10 MV x-선, $14{\times}14cm^2$ 조사면 경계로부터 10 cm 밖에서 납벽돌의 반가층 두께는 약 9.0 mm 이였고 20cm 밖에서는 반가층 두께가 약 6.5 mm로 측정되었다. 복부에 위치한 악성종양을 60 Gy 조사하였을 경우 태아가 위치하고 있는 자궁의 피폭선량은 약 370 mGy이고 이곳을 10 mGy이하가 되도록 차폐하려면 약 6.2 cm두께의 납 벽돌을 자궁위에 장착하여야 하며 골반치료시 고환에 10 mGy이하가 되도록 차폐하려면 약 5 cm 두께의 납 항아리가 요구된다. 고 에너지 고 준위 방사선치료시 고환은 3면을 항아리모양으로 차폐할 수 있어 피폭선량을 상당히 줄일 수 있으며 자궁인 경우 체내에서 산란된 선량의 차폐는 불가능하였다.