An Analysis on Performance Test of TLD and MTLD Using Shaking Table

진동대를 이용한 TLD와 MTLD의 성능실험에 대한 분석

  • 유장열 (전북대학교 건축도시공학부) ;
  • 송창현 (전북대학교 건축도시공학부) ;
  • 유기표 (전북대학교 건축도시공학부) ;
  • 김영문 (전북대학교 건축도시공학부)
  • Published : 2008.05.02

Abstract

Experimental studies using tuned liquid damper(TLD) and multiple tuned liquid damper(MTLD), which are passive control devices consisting of a rigid tank filed with liquid, are used to suppress vibration of structures. This TLD and MTLD are attributable to several potential advantage -low costs, easy; easy to install in existing structures: effective even for small amplitude vibrations. For this, we conducted shaking table experiments for two natural frequencies (0.44Hz, 0.55Hz) according to the excitation amplitude(1mm, 3mm, 5mm, 10mm, 20mm) So, the majority of studies suggested optimized natural frequence and excitation amplitude for control devices.(TLD and MTLD type : circle, rectangular) As the analysis result, we verified vibration reduction effects of a MTLD by analyzing the performance experiment of TLD and MTLD

본 논문은 건물의 형태와 동적특성을 변화시키지 않고 건물에 부가질량을 설치하여 건물의 진동을 제어하는 방법중 수동형 제진장치인 TLD(tuned liquid damper)와 MTLD(multiple tuned liquid damper)의 진동응답을 감소시키기 위해 진동대를 이용한 성능실험을 실시하였다. 따라서 기존의 형태별(원형, 직사각형) TLD 실험의 실험 데이터를 가지고 가진 진폭(1mm, 3mm, 5mm, 10mm, 20mm) 의 변화에 따른 고유진동수(0.44Hz, 0.55Hz)에 대한 MTLD의 형태별 실험을 통하여 TLD와 MTLD의 진동감소효과에 대한 성능실험을 비교 분석 하였다.

Keywords