• Title/Summary/Keyword: radiation sources

Search Result 599, Processing Time 0.029 seconds

Chamber to Chamber Variations of a Cylindrical Ionization Chamber for the Calibration of an $^{192}Ir$ Brachytherapy Source Based on an Absorbed Dose to Water Standards (물흡수선량 표준에 기반한 $^{192}Ir$ 근접치료 선원 교정 시 원통형 이온함의 이온함 간 변화)

  • Kim, Seong-Hoon;Huh, Hyun-Do;Choi, Sang-Hyun;Kim, Chan-Hyeong;Min, Chul-Hee;Shin, Dong-Oh;Choi, Jin-Ho
    • Progress in Medical Physics
    • /
    • v.20 no.1
    • /
    • pp.7-13
    • /
    • 2009
  • This work is for the preliminary study for the calibration of an $^{192}Ir$ brachytherapy source based on an absorbed dose to water standards. In order to calibrate brachytherapy sources based on absorbed dose to water standards using a clyndirical ionization chamber, the beam quality correction factor $k_{Q,Q_0}$ is needed. In this study $k_{Q,Q_0}s$ were determined by both Monte carlo simulation and semiexperimental methods because of the realistic difficulties to use primary standards to measure an absolute dose at a specified distance. The 5 different serial numbers of the PTW30013 chamber type were selected for this study. While chamber to chamber variations ran up to maximum 4.0% with the generic $k^{gen}_{Q,Q_0}$, the chamber to chamber variations were within a maximum deviation of 0.5% with the individual $k^{ind}_{Q,Q_0}$. The results show why and how important ionization chambers must be calibrated individually for the calibration of $^{192}Ir$ brachytherapy sources based on absorbed dose to water standards. We hope that in the near future users will be able to calibrate the brachytherapy sources in terms of an absorbed dose to water, the quantity of interest in the treatment, instead of an air kerma strength just as the calibration in the high energy photon and electron beam.

  • PDF

DataBase system construction for the study of radiation hardened electronic devices using pulse radiation (펄스방사선을 이용한 내방사선 연구 DB 구축)

  • Ko, Seong-Gon;Oh, Seung-Chan;Hwang, Young-Gwan;Jeong, Sang-Hun;Lee, Nam-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.05a
    • /
    • pp.778-781
    • /
    • 2012
  • The electronic element the damage occurs with radiation being bombed. In order applies in the artificial satellite or the space ship therefore from the within has radiation introspection the use of the radiation electronic element is essential. Transient radiation tests performed for the first time in Korea evaluation data database (DB) was constructed to. Web-based materials in the DB is designed to be able to search and update, and existing foreign (NASA, ESA) for a total of 695 species, including public sources of data has been entered. Search DB than the existing foreign DB is an efficient and practical.

  • PDF

RADIATION SAFETY ASSESSMENT FOR KN-12 SPENT NUCLEAR FUEL TRANSPORT CASK USING MONTE CARLO SIMULATION

  • Kim, J.K.;Kim, G.H.;Shin, C.H.;Choi, H.S.
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.3
    • /
    • pp.207-214
    • /
    • 2001
  • The KN-12 spent nuclear fuel (SNF) transport cask is designed for transportation of up to 12 assemblies and is in standby status for being licensed in accordance with Korea Atomic Energy Act. To evaluate radiation shielding and criticality safety of the KN-12 cask, each case of study was carried out using MCNP4B Code. MCNP code is verified by performing benchmark calculation for the KSC-4 SNF cask designed in 1989. As a result of radiation safety evaluation for the KN-12 cask, calculated dose rates always satisfied the standards at the cask surface, at 2m from the surface in normal transport condition, and at 1 m from the surface in hypothetical accident condition. Maximum dose rate was always arisen on the side of the cask. For normal transport condition, photons primarily contribute to dose rate between two kinds of released sources, neutrons and photons, from spent nuclear fuel but for hypothetical accident condition, contrary case was resulted. The level of calculated dose rate was 27.8% of the limit at the cask surface, 89.3% at 2 m from the cask surface, and 25.1% at 1 m from the cask surface. For criticality analysis, keff resulting from the criticality analysis considering the condition of optimum partial flooding with fresh water is 0.89708(0.00065. The results confirm the standards recommended by all regulations on radiation safety.

  • PDF

Understanding radiation effects in SRAM-based field programmable gate arrays for implementing instrumentation and control systems of nuclear power plants

  • Nidhin, T.S.;Bhattacharyya, Anindya;Behera, R.P.;Jayanthi, T.;Velusamy, K.
    • Nuclear Engineering and Technology
    • /
    • v.49 no.8
    • /
    • pp.1589-1599
    • /
    • 2017
  • Field programmable gate arrays (FPGAs) are getting more attention in safety-related and safety-critical application development of nuclear power plant instrumentation and control systems. The high logic density and advancements in architectural features make static random access memory (SRAM)-based FPGAs suitable for complex design implementations. Devices deployed in the nuclear environment face radiation particle strike that causes transient and permanent failures. The major reasons for failures are total ionization dose effects, displacement damage dose effects, and single event effects. Different from the case of space applications, soft errors are the major concern in terrestrial applications. In this article, a review of radiation effects on FPGAs is presented, especially soft errors in SRAM-based FPGAs. Single event upset (SEU) shows a high probability of error in the dependable application development in FPGAs. This survey covers the main sources of radiation and its effects on FPGAs, with emphasis on SEUs as well as on the measurement of radiation upset sensitivity and irradiation experimental results at various facilities. This article also presents a comparison between the major SEU mitigation techniques in the configuration memory and user logics of SRAM-based FPGAs.

Duct Effects on rotor noise in radiation (덕트가 로터 소음 방사에 미치는 영향)

  • Choi, Han-Lim;Chung, Ki-Hoon;Lee, Duck-Joo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.938-941
    • /
    • 2004
  • Sound generation and radiation from the duct-rotor system are calculated numerically. The wake geometries of a two-bladed rotor are calculated by using a time-marching fiee-wake method without a non-physical model of the far wake. Acoustic free field due to a rotating rotor is obtained by Lowson's equation. Using Kirchhoff source, rotating sources are modeled as stationary ones and can be inserted in the thin body boundary element method. The Kirchhoff source is validated through calculation of acoustic pressure due to a rotating point force. The thin body boundary element method (thin body BEM) is validated through calculation of acoustic radiation of ducted dipole. Using Kirchhoff source and thin body BEM, acoustic radiation of a ducted rotating source is calculated. Acoustic shielding is observed by inserting a duct and shows different phenomena at each major frequency. Acoustic radiation of a real duct-rotor system is also calculated using this method and the ducted acoustic field is significantly different from rotor only.

  • PDF

Feasibility study of spent fuel internal tomography (SFIT) for partial defect detection within PWR spent nuclear fuel

  • Hyung-Joo Choi;Hyojun Park;Bo-Wi Cheon;Hyun Joon Choi;Hakjae Lee;Yong Hyun Chung;Chul Hee Min
    • Nuclear Engineering and Technology
    • /
    • v.56 no.6
    • /
    • pp.2412-2420
    • /
    • 2024
  • The International Atomic Energy Agency (IAEA) mandates safeguards to ensure non-proliferation of nuclear materials. Among inspection techniques used to detect partial defects within spent nuclear fuel (SNF), gamma emission tomography (GET) has been reported to be reliable for detection of partial defects on a pin-by-pin level. Conventional GET, however, is limited by low detection efficiency due to the high density of nuclear fuel rods and self-absorption. This paper proposes a new type of GET named Spent Fuel Internal Tomography (SFIT), which can acquire sinograms at the guide tube. The proposed device consists of the housing, shielding, C-shaped collimator, reflector, and gadolinium aluminum gallium garnet (GAGG) scintillator. For accurate attenuation correction, the source-distinguishable range of the SFIT device was determined using MC simulation to the region away from the proposed device to the second layer. For enhanced inspection accuracy, a proposed specific source-discrimination algorithm was applied. With this, the SFIT device successfully distinguished all source locations. The comparison of images of the existing and proposed inspection methods showed that the proposed method, having successfully distinguished all sources, afforded a 150 % inspection accuracy improvement.

The Analysis of the Collimator & Radiation Shield for the Radiation Sensor for the 3Dimension Radiation Detection (3차원 방사선 탐지장치용 검출센서의 차폐체 및 Collimator 구조 분석 연구)

  • Hwang, Young-Gwan;Lee, Nam-Ho;Park, Sumg-Hun;Jeong, Sang-Hun;Kim, Jong-Ryul;Choi, Myung-Jin
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.05a
    • /
    • pp.707-709
    • /
    • 2014
  • The radiation sources leaked from large-scale radiation leak accident like the Fukushima nuclear power plant accident or nuclear explosions can cause to the very large damage for us. So that the damage can be minimized, we have being developed a detector that can providing information about the location of the source to remove dangerous substances quickly than the conventional single detector. In this paper, we designed and implemented the radiation shield and the collimator for the development of the stereo radiation detector to detect contamination things using MCNP Simulation. And we analysed the test results of the radiation shield and collimator using the radiation source. The results of this paper will be used as the basis for improving the efficiency of the stereo radiation detector being studied currently.

  • PDF

The Measurement and Analysis for Ultraviolet Radiation (자외선복사의 측정과 분석)

  • Han, Jong-Sung;Kim, Hong-Bum;Kim, Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.2
    • /
    • pp.7-12
    • /
    • 2005
  • When a light is projected upon a material, part of its radiant energy is absorbed and the rest is reflected or transmitted according to the nature of the material. The molecules of the substance absorbing a light obtains the radiant energy to make thermal reactions or photochemical reactions. Specially, photochemical reactions by ultraviolet(UV) radiation brings about photochemical degradation such as color change. Because the photochemical damage brings about a devaluation of material and once damaged, it is irretrievable, it is necessary to minimize the damage and conserve the native quality of a material by a protective lighting system. This paper presents the measurement and photochemical damage for UV radiation from light sources. We measured the optical radiations from artificial light sources and daylight, and we analyzed a functional relation between irradiance and UV radiation form the results.

Fabrication, characterization, simulation and experimental studies of the ordinary concrete reinforced with micro and nano lead oxide particles against gamma radiation

  • Mokhtari, K.;Kheradmand Saadi, M.;Ahmadpanahi, H.;Jahanfarnia, Gh.
    • Nuclear Engineering and Technology
    • /
    • v.53 no.9
    • /
    • pp.3051-3057
    • /
    • 2021
  • The concrete is considered as an important radiation shielding material employed widely in nuclear reactors, particle accelerators, laboratory hot cells and other different radiation sources. The present research is dedicated to the shielding properties study of the ordinary concrete reinforced with different weight fractions of lead oxide micro/nano particles. Lead oxide particles were fabricated by chemical synthesis method and their properties including the average size, morphological structure, functional groups and thermal properties were characterized by XRD, FESEM-EDS, FTIR and TGA analysis. The gamma ray mass attenuation coefficient of concrete composites has been calculated and measured by means of the Monte Carlo simulation and experimental methods. The simulation process was based on the use of MCNP Monte Carlo code where the mass attenuation coefficient (μ/ρ) has been calculated as a function of different particle sizes and filler weight fractions. The simulation results showed that the employment of the lead oxide filler particles enhances the mass attenuation coefficient of the ordinary concrete, drastically. On the other hand, there are approximately no differences between micro and nano sized particles. The mass attenuation coefficient was increased by increasing the weight fraction of nanoparticles. However, a semi-saturation effect was observed at concentrations more than 10 wt%. The experimental process was based on the fabrication of concrete slabs filled by different weight fractions of nano lead oxide particles. The mass attenuation coefficients of these slabs were determined at different gamma ray energies using 22Na, 137Cs and 60Co sources and NaI (Tl) scintillation detector. The experimental results showed that the HVL parameter of the ordinary concrete reinforced with 5 wt% of nano PbO particles was reduced by 64% at 511 keV and 48% at 1332 keV. Reasonable agreement was obtained between simulation and experimental results and showed that the employment of nano PbO particles is more efficient at low gamma energies up to 1Mev. The proposed concrete is less toxic and could be prepared in block form instead of toxic lead blocks.

Optimization of Yonsei Single-Photon Emission Computed Tomography (YSECT) Detector for Fast Inspection of Spent Nuclear Fuel in Water Storage

  • Hyung-Joo Choi;Hyojun Park;Bo-Wi Cheon;Kyunghoon Cho;Hakjae Lee;Yong Hyun Chung;Yeon Soo Yeom;Sei Hwan You;Hyun Joon Choi;Chul Hee Min
    • Journal of Radiation Protection and Research
    • /
    • v.49 no.1
    • /
    • pp.29-39
    • /
    • 2024
  • Background: The gamma emission tomography (GET) device has been reported a reliable technique to inspect partial defects within spent nuclear fuel (SNF) of pin-by-pin level. However, the existing GET devices have low accuracy owing to the high attenuation and scatter probability for SNF inspection condition. The purpose of this study is to design and optimize a Yonsei single-photon emission computed tomography version 2 (YSECT.v.2) for fast inspection of SNF in water storage by acquisition of high-quality tomographic images. Materials and Methods: Using Geant4 (Geant4 Collaboration) and DETECT-2000 (Glenn F. Knoll et al.) Monte Carlo simulation, the geometrical structure of the proposed device was determined and its performance was evaluated for the 137Cs source in water. In a Geant4-based assessment, proposed device was compared with the International Atomic Energy Agency (IAEA)-authenticated device for the quality of tomographic images obtained for 12 fuel sources in a 14 × 14 Westinghouse-type fuel assembly. Results and Discussion: According to the results, the length, slit width, and septal width of the collimator were determined to be 65, 2.1, and 1.5 mm, respectively, and the material and length of the trapezoidal-shaped scintillator were determined to be gadolinium aluminum gallium garnet and 45 mm, respectively. Based on the results of performance comparison between the YSECT.v.2 and IAEA's device, the proposed device showed 200 times higher performance in gamma-detection sensitivity and similar source discrimination probability. Conclusion: In this study, we optimally designed the GET device for improving the SNF inspection accuracy and evaluated its performance. Our results show that the YSECT.v.2 device could be employed for SNF inspection.