• Title/Summary/Keyword: pulse measurement

Search Result 949, Processing Time 0.027 seconds

Time-dependent Characteristics of Pulse Modulated rf Plasma (펄스모듈레이션 된 고주파 플라즈마의 시변특성)

  • Lee Sun-Hong;Park Chung-Hoo;Lee Ho-Jun
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.11
    • /
    • pp.566-571
    • /
    • 2004
  • Pulse modulation technique provide additional controling method for electron temperature and density in rf and microwave processing plasma. Transient characteristics of electron density and temperature have been measured in pulse modulated rf inductively coupled argon plasma using simple probe circuit. Electron temperature relaxation is clearly identified in the after glow stage. Controllability of average electron temperature and density depends on the modulation frequency and duty ratio. Numerical calculation of time-dependent electron density and temperature have been performed based on the global model. It has been shown that simple langmuir probe measurement method used for continuous plasma is also applicable to time-dependent measurement of pulse modulated plasma.

The quantitative study on the Renying·Qi mouth comparison pulse diagnosis (인영(人迎)·기구비교맥법(氣口比較脈法)의 정량화(定量化)에 관(關)한 연구(硏究))

  • Cho, Myung-Rae;Kim, Moo-Shin;Ryu, Choong-Ryul;Choi, Chan-Hun;Jang, Kyeong-Seon;So, Cheol-Ho;Park, Young-Dae
    • Journal of Acupuncture Research
    • /
    • v.19 no.2
    • /
    • pp.149-163
    • /
    • 2002
  • Objective : We have studied literatures of Renying Qi mouth comparison pulse diagnosis theory and distinguished the excess, deficiency and quick-temper of pulse as the measurement parameter of Renying Qi mouth pulse diagnosis. Methods : We have acquired pulse signals of Renying Qi mouth by using diagnostic equipment of Renying Qi mouth pulsation and estimated reappearance of pulse signals. Results : 1. The measurement parameter of Renying Qi mouth pulse diagnosis distinguishes the excess, deficiency and quick-temper of pulse through relative comparison of Renying Qi mouth. 2. When we acquired the pulse singals of Renying Qi mouth by using diagnostic equipment, the property, measuring area, bias pressure, contact or adhesion state of the sensor are considered. 3. As getting the pulse signal of Renying Qi mouth, the sensor of a sound detective mode is effective. 4. The diagnostic equipment of Renying Qi mouth pulse is assessed as being significant reappearance.

  • PDF

MEASUREMENT OF LONG IMPULSE RESPONSE BY USING A TIME-STRETCHED PULSE

  • Kim, Hack-Yoon;Asano, Futoshi;Suzuki, Yoiti;Sone, Toshio
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1994.06a
    • /
    • pp.867-872
    • /
    • 1994
  • The transfer function of an acoustic system, in general, often exhibits a wide dynamic range and a very long impulse response. The time-stretched pulse (TSP) proposed by Aoshima (ATSP) has a small peak-factor and is accordingly suitable for the measuring impulse responses. The pulse is not so suitable, however, for the measurement of impulse responses over a wide frequency range. In this paper, we try to generalize and optimize this method (OATSP). This makes the method applicable for measuring of impulse responses longer than the length of the TSP. An analysis of error in such a case is also shown. Finally, we discuss how to implement this technique in specific measurement conditins.

  • PDF

An Operating Frequency Independent Energy Measurement Technique for High Speed Microprocessors

  • Thongnoo, Krerkchai;Changtong, Kusumal
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.2051-2054
    • /
    • 2004
  • This paper proposes a more accurate task level energy measurement technique for high speed microprocessors. The technique is based on the relationship of the amount of current consumed by the microprocessor and the pulse width of the power supply controller chip, employed in the synchronous buck DC-DC converter in the microprocessor's power supply. The accuracy of the measurement is accomplished by measuring variation in pulse width in each power supply cycle. The major advantage of this technique is that its accuracy does not depend on the operating frequency of the microprocessor. To prove the proposed technique, we implemented the measurement unit of the microprocessor energy meter using an FPGA chip operating at 50 MHz. Both static and dynamic load measurement are tested in order to obtain some behaviours. Moreover, various commercially available mainboards which employ synchronous buck regulators at 200 KHz switching frequency, were measured. The results agree with previous works with better accuracy at higher operating frequency.

  • PDF

Design of Measurement System and Thrust Force Analysis Method for HB-Type Linear Pulse Motor (HB형 선형 펄스모터의 추력 계산법의 비교 및 측정장치 설계)

  • Bae D.K.;Kim K.H.;Park H.S.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.141-145
    • /
    • 2003
  • The linear motor available for linear transition motion, because of its advantages, the motor design and its application have gradually increased, but the quantitative measurement system of thrust force has not been generalized. So, this paper proposes the modeling, computation method, and measurement system of linear thrust force in HB-type linear pulse motor. As the computation method of thrust force in linear motor is presented and the measurement system is designed, and manufactured, it would be verified that reliability of measurement method and measurement system, considering on and comparing the results of mathematical modeling with measured values of static thrust force and dynamic one.

  • PDF

Implementation of the Pulse Wave Measurement System Using Bipolar Biased Head on Mode of the Hall Sensor (홀 센서의 양극 바이어스 수직모드를 이용한 맥파측정시스템 구현)

  • Jin, Sang-Gon;Kim, Myoung-Nam
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.5
    • /
    • pp.322-328
    • /
    • 2011
  • There are many ways to detect the heart rate non-invasively such as ECG, PPG, strain gauge, and pressure sensor. In this paper, the pulse wave measurement system using bipolar biased head on mode of the Hall sensor is proposed for measuring the radial artery pulse. TMS320F2812 was used to implement the proposed system and a portable wireless network(zig-bee) was used to show the experimental result. It was confirmed from experiment that the performance of the implemented system was more stable and faster than PPG sensor or piezoelectric film pressure sensor.

Development of 3-channel Pulse Wave Measurement System (3채널 맥파 측정 시스템 개발)

  • Kim, Eun-Geun;Heo, Hyun;Nam, Ki-Chang;Kang, Hee-Jung;Huh, Young
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.1049-1050
    • /
    • 2008
  • It is difficult to measure the pulse wave in a short time because radial artery position and located depth are different depending on the person. In this paper, the pulse wave measurement system was developed using 3 channel piezoresistive sensor array to detect the most significant pulse wave. Augmentation Index(AI) and Heart Rate(HR) analysis are also available for predicting cardiovascular risks. The developed system is small and easy to use. And it is promising to be used as home healthcare device.

  • PDF

Estimation of Non- Invasive Blood Pressure Using Peripheral Plethysmograph (말초혈관 혈류 측정을 이용한 비관혈적 혈압 추정법에 대한 연구)

  • Jeong In-cheol;Shin Tae-min;Yoon Hyung-Ro
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.54 no.8
    • /
    • pp.504-509
    • /
    • 2005
  • This paper presents a new method for obtaining the noninvasive and unrestrained blood pressure readings noninvasively and unrestrainedly using based on reflected wave arrival time(RAT) in the volume of pulse. Since this new method employs only volume pulse, is more rapider and simpler than the method using pulse transit time(PTT) because it only employs the volume of pulse. Blood pressure, PTT and RAT were acquired from 15 healthy subjects. Each subjects were performed forty trials of each measurement. As a result of those trials, the mean error between oscillometric and RAT measurements for systolic blood pressure was $4.55\pm5.64mmHg$. This result showed quite equal with the mean error between oscillometric and PPT measurf:ments, $4.22\pm5.30mmHg$, However, it was not obtained a satisfactory result in the relativity of oscillometric to both RAT and PPT measurements for diastolic blood pressure because of personal difference. To conclude, the method of systolic blood pressure estimation noninvasively and unrestrainedly using by RAT may be used as the method by PTT. Nevertheless, additional studies would be necessary for the RAT/PTT estimation of diastolic blood Pressure measurement.

Systolic blood pressure measurement algorithm with mmWave radar sensor

  • Shi, JingYao;Lee, KangYoon
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.16 no.4
    • /
    • pp.1209-1223
    • /
    • 2022
  • Blood pressure is one of the key physiological parameters for determining human health, and can prove whether human cardiovascular function is healthy or not. In general, what we call blood pressure refers to arterial blood pressure. Blood pressure fluctuates greatly and, due to the influence of various factors, even varies with each heartbeat. Therefore, achievement of continuous blood pressure measurement is particularly important for more accurate diagnosis. It is difficult to achieve long-term continuous blood pressure monitoring with traditional measurement methods due to the continuous wear of measuring instruments. On the other hand, radar technology is not easily affected by environmental factors and is capable of strong penetration. In this study, by using machine learning, tried to develop a linear blood pressure prediction model using data from a public database. The radar sensor evaluates the measured object, obtains the pulse waveform data, calculates the pulse transmission time, and obtains the blood pressure data through linear model regression analysis. Confirm its availability to facilitate follow-up research, such as integrating other sensors, collecting temperature, heartbeat, respiratory pulse and other data, and seeking medical treatment in time in case of abnormalities.

Development of Pulse Measurement Method for Health Monitoring of Dairy Cows (젖소 건강 모니터링을 위한 맥박 측정 방법 개발)

  • Jun, Hak-Bong;Kim, Han-Joon;Kim, Jin-Oh
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.12
    • /
    • pp.27-37
    • /
    • 2013
  • Today, livestock industry grows faster and bigger. The number of livestock numbers per farm also grows rapidly. The bigger farms need more sophisticated control of livestock to prevent from all possible diseases, especially contagious diseases. In Korea, diseases cause serious economic loss of 2 trillion won every year, which is about 20% of the total production output. Researches on the wireless bio-signal monitoring technology for livestock are of great importance in the world. In this paper, as a way to predict the possible diseases, we propose a measurement method of the pulse of dairy cows for the continuous health monitoring. It is possible to measure a pulse from central artery and the left chest-wall of the cow. The pulse from central artery is measured by the sensor attached at the tail winding. The pulse at the left chest-wall can also be measured with our newly designed harness.