• Title/Summary/Keyword: process diagnostics

Search Result 180, Processing Time 0.021 seconds

Experimental Investigation on Admittance-Based Piezoelectric Sensor Diagnostic Process (Admittance 기반 압전체 센서 자가진단절차의 영향인자 파악 및 실험적 고찰)

  • Jo, HyeJin;Park, Tong-Il;Park, Gyuhae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.1
    • /
    • pp.37-43
    • /
    • 2015
  • Structural health monitoring (SHM) techniques based on the use of active-sensing piezoelectric (PZT) materials have received considerable attention. The validation of the PZT functionality during SHM operation is critical to successfully implementing a reliable SHM system. In this study, we investigated several parameters that affect the admittance-based sensor diagnostic process. We experimentally identified the temperature dependency of the active-sensor diagnostic process. We found that the admittance-based sensor diagnostic process can differentiate the adhesion conditions of bonding materials that are used to install a PZT on a structure, which is important when designing a sensor diagnostic process for an SHM system.

Multiagent Enabled Modeling and Implementation of SCM (멀티에이전트 기반 SCM 모델링 및 구현)

  • Kim Tae Woon;Yang Seong Min;Seo Dae Hee
    • The Journal of Information Systems
    • /
    • v.12 no.2
    • /
    • pp.57-72
    • /
    • 2003
  • The purpose of this paper is to propose the modeling of multiagent based SCM and implement the prototype in the Internet environment. SCM process follows the supply chain operations reference (SCOR) model which has been suggested by Supply Chain Counsil. SCOR model has been positioned to become the industry standard for describing and improving operational process in SCM. Five basic processes, plan, source, matte, deliver and return are defined in the SCOR model, through which a company establishes its supply chain competitive objectives. A supply chain is a world wide network of suppliers, factories, warehouses, distribution centers and retailers through which raw materials are acquired, transformed or manufactured and delivered to customers by autonomous or semiautonomous process. With the pressure from the higher standard of customer compliance, a frequent model change, product complexity and globalization, the combination of supply chain process with an advanced infrastructure in terms of multiagent systems have been highly required. Since SCM is fundamentally concerned with coherence among multiple decision makers, a multiagent framework based on explicit communication between constituent agents such as suppliers, manufacturers, and distributors is a natural choice. Multiagent framework is defined to perform different activities within a supply chain. Dynamic and changing functions of supply chain can be dealt with multi-agent by cooperating with other agents. In the areas of inventory management, remote diagnostics, communications with field workers, order fulfillment including tracking and monitoring, stock visibility, real-time shop floor data collection, asset tracking and warehousing, customer-centric supply chain can be applied and implemented utilizing multiagent. In this paper, for the order processing event between the buyer and seller relationship, multiagent were defined corresponding to the SCOR process. A prototype system was developed and implemented on the actual TCP/IP environment for the purchase order processing event. The implementation result assures that multiagent based SCM enhances the speed, visibility, proactiveness and responsiveness of activities in the supply chain.

  • PDF

Development of fission 99Mo production process using HANARO

  • Lee, Seung-Kon;Lee, Suseung;Kang, Myunggoo;Woo, Kyungseok;Yang, Seong Woo;Lee, Junsig
    • Nuclear Engineering and Technology
    • /
    • v.52 no.7
    • /
    • pp.1517-1523
    • /
    • 2020
  • The widely used medical isotope technetium-99 m (99mTc) is a daughter of Molybdenum-99 (99Mo), which is mainly produced using dedicated research reactors from the nuclear fission of uranium-235 (235U). 99mTc has been used for several decades, which covers about 80% of the all the nuclear diagnostics procedures. Recently, the instability of the supply has become an important topic throughout the international radioisotope communities. The aging of major 99Mo production reactors has also caused frequent shutdowns. It has triggered movements to establish new research reactors for 99Mo production, as well as the development of various 99Mo production technologies. In this context, a new research reactor project was launched in 2012 in Korea. At the same time, the development of fission-based 99Mo production process was initiated by Korea Atomic Energy Research Institute (KAERI) in 2012 in order to be implemented by the new research reactor. The KAERI process is based on the caustic dissolution of plate-type LEU (low enriched uranium) dispersion targets, followed by the separation and purification using a series of columns. The development of proper waste treatment technologies for the gaseous, liquid, and solid radioactive wastes also took place. The first stage of this process development was completed in 2018. In this paper, the results of the hot test production of fission 99Mo using HANARO, KAERI's 30 MW research reactor, was described.

Development of Industrial-Scale Fission 99Mo Production Process Using Low Enriched Uranium Target

  • Lee, Seung-Kon;Beyer, Gerd J.;Lee, Jun Sig
    • Nuclear Engineering and Technology
    • /
    • v.48 no.3
    • /
    • pp.613-623
    • /
    • 2016
  • Molybdenum-99 ($^{99}Mo$) is the most important isotope because its daughter isotope, technetium-99m ($^{99m}Tc$), has been the most widely used medical radioisotope for more than 50 years, accounting for > 80% of total nuclear diagnostics worldwide. In this review, radiochemical routes for the production of $^{99}Mo$, and the aspects for selecting a suitable process strategy are discussed from the historical viewpoint of $^{99}Mo$ technology developments. Most of the industrial-scale $^{99}Mo$ processes have been based on the fission of $^{235}U$. Recently, important issues have been raised for the conversion of fission $^{99}Mo$ targets from highly enriched uranium to low enriched uranium (LEU). The development of new LEU targets with higher density was requested to compensate for the loss of $^{99}Mo$ yield, caused by a significant reduction of $^{235}U$ enrichment, from the conversion. As the dramatic increment of intermediate level liquid waste is also expected from the conversion, an effective strategy to reduce the waste generation from the fission $^{99}Mo$ production is required. The mitigation of radioxenon emission from medical radioisotope production facilities is discussed in relation with the monitoring of nuclear explosions and comprehensive nuclear test ban. Lastly, the $^{99}Mo$ production process paired with the Korea Atomic Energy Research Institute's own LEU target is proposed as one of the most suitable processes for the LEU target.

Non-thermal Plasma for Air Pollution Control Technology (저온 플라즈마 이용 대기환경설비기술)

  • Song, Young-Hoon
    • Applied Chemistry for Engineering
    • /
    • v.17 no.1
    • /
    • pp.1-11
    • /
    • 2006
  • Non-thermal plasma technology for air pollution control, which are NOx, SOx, VOCs, soot, etc., is reviewed. In the early parts of the paper, generation of non-thermal plasma and plasma chemical process are introduced to provide an appropriate plasma condition (electron energy density) for treating air pollutions. Recent results on numerical simulation, optical diagnostics, and gas treatment are provided to characterize an optimal design of plasma generation and plasma chemical process. These data are also helpful to understand unique features of non-thermal plasma process that is achieved with relatively low temperature conditions, i.e. low enthalpy conditions of the treated gas molecules. In the later parts of the paper, several examples of recently developed non-thermal plasma techniques are illustrated, in which technical and economical assessments of the present techniques are provided.

Study on Electron Temperature Diagnostic and the ITO Thin Film Characteristics of the Plasma Emission Intensity by the Oxygen Gas Flow (산소 유량별 플라즈마 방출광원 세기에 따른 전자온도 진단과 산화주석박막 특성연구)

  • Park, Hye Jin;Choi, Jin-Woo;Jo, Tae Hoon;Yun, Myoung Soo;Kwon, Gi-Chung
    • Journal of the Korean institute of surface engineering
    • /
    • v.49 no.1
    • /
    • pp.92-97
    • /
    • 2016
  • The plasma has been used in various industrial fields of semiconductors, displays, transparent electrode and so on. Plasma diagnostics is critical to the uniform process and the product. We use the electron temperature of the various plasma parameters for the diagnosis of plasma. Generally, the range of the electron temperature which is used in a semiconductor process used the range of 1 eV to 10 eV. The difference of electron temperature of 0.5 eV has a influence in plasma process. The electron temperature can be measured by the electrical method and the optical method. Measurement of electron temperature for various gas flow rates was performed in DC-magnetron sputter and Inductively Coupled Plasma. The physical properties of the thin film were also determined by changing electron temperatures. The transmittance was measured using the integrating sphere, and wavelength range was measured at 300 ~ 1100 nm. We obtain the thin film of the mobility, resistivity and carrier concentration using the hall measurement system. As to the electron temperature increase, optical and electrical properties decrease. We determine it was influenced by the oxygen flow ratio and plasma.

Probing the Feedback Process in Local Type-2 AGNs with Integral-Field Spectroscopy

  • Luo, Rongxin;Woo, Jong-Hak;Shin, Jaejin;Kang, Daeun;Bae, Hyun-Jin;Karouzos, Marios
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.44 no.1
    • /
    • pp.36.3-36.3
    • /
    • 2019
  • Feedback process is one of the most important topics in the study of AGNs since it plays a key role in linking the SMBHs and their host galaxies. In order to further understand the co-evolution of SMBHs and their host galaxies, we probe the feedback process in local type-2 AGNs with a series of integral-field-spectroscopy observations. In the first part of my talk, I will introduce our GMOS observations of luminous type-2 AGNs at z < 0.1, which are selected using the integrated [O III] kinematics. Based on the dedicated emission-line diagnostics and kinematic studies, we identify the signatures of AGN-driven outflows and quantify the outflow size in the targets with extreme [O III] kinematics. For the targets without extreme [O III] kinematics, we find the presence of weak AGN-driven outflows, which are indicated by the significant differences between the kinematics of gas and stars. Then, I will present our recent study of 40 type-2 AGNs based on the SNIFS IFU. By comparing the radial profile of velocity dispersion of gas and stars, we measure the size of AGN-driven outflows in these targets and extend the outflow size-AGN luminosity relation in our previous GMOS studies. We also discuss the feedback effect of AGN-driven outflows by connecting the outflow velocity and host galaxy properties. These results highlight the importance of spatially-resolved observation in investigating gas kinematics and identifying the signatures of AGN-driven outflows.

  • PDF

Association Between Vertebrobasilar Insufficiency and Cervicogenic Headache: Hypothetical Approach Towards Etiopathogenesis of Headache

  • Kaur, Aninditya;Rakesh, N.;Reddy, Sujatha S.;Thomas, Nithin;Nagi, Ravleen;Patil, Deepa Jatti
    • Journal of Oral Medicine and Pain
    • /
    • v.45 no.4
    • /
    • pp.97-109
    • /
    • 2020
  • Purpose: Cervicogenic headache (CGH) is pain referred to the head/ face from the structures in vicinity of upper cervical spinal nerves via trigeminocervical pathway. Ponticulus Posticus (PP) and Elongated Styloid Process (ESP) are anatomical structures that cause compression of vasculature present around upper cervical nerve plexus. Recently, computational fluid dynamics (CFD) has shown to play an essential role in identification of these high-pressure zones in the brain. The aim of this research is to study the association of ESP and PP in patients with CGH and to develop a hypothesis by CFD to analyse vertebrobasilar insufficiency as a contributing factor in occurrence of CGH. Methods: Retrospective analysis of 4500 full skull CBCT scans was done for the presence of partial or complete PP and length of Styloid Process (SP). Research was divided into two phases; In first Preliminary Phase, 150 scans that showed the presence of PP and ESP were analysed, and only 134 patients gave consent to fill the questionnaire containing 96 question items pertaining to symptoms associated with CGH. In the second phase, simulation of Vertebral and Carotid Artery was done using Fluent 14.5 Software and by CFD, pressure distribution on arteries was obtained that helped to identify high pressure regions. Results: Both PP and ESP showed a statistically significant association with CGH (p<0.001). By CFD analysis, both steady and transient phases of simulation showed drop in pressure due to constriction of internal carotid and vertebral artery by ESP and PP respectively and were found to decrease the volume of blood reaching the brain, 0.12 /0.13 mL and 0.06 mL respectively. Conclusions: Our analysis proves ESP and PP as contributing factors towards CGH. Hence for proper diagnosis and management of headache disorders, clinicians should have adequate knowledge about these anatomical structures and their resulting clinical symptoms.

Invastigating literatures about mechanism of internal·external damage, through Qi mouth and Renying (기구(氣口), 인영맥(人迎脈)의 진단(診斷)을 통(通)한 내상(內傷), 외감병기(外感病機)에 대(對)한 문헌적(文獻的) 고찰(考察))

  • Kim, Moo-Sin;Cho, Myung-Rae;Park, Young-Bae
    • Journal of Acupuncture Research
    • /
    • v.18 no.4
    • /
    • pp.161-177
    • /
    • 2001
  • Objective : We have studied the part, definition, diagnostic generaliztion and pathological viewpoint of Qi mouth and Renying by refering literatures Methods : I refered to records from anciant to modern. The results are followings : 1. Qi mouth and Renying is ancient diagnostic method and the origin of diagnostic method through the pulsation of radial artery. And Qi mouth is recognized as the right and left Qi mouth and Renying is located on pulsation points of both common carotid arteries. 2. The yin of five viscera, nutritional blood and viscous liquid are diagnosed by Qi mouth which is inclued lung meridian. And the yang of six organs, guarding Qi and the rise and fall of stomach energy are diagnosed by Renying which is inclued stomach meridian. 3. It is possible that the position, process and transformational condition of disease are decided by comparing and examining Qi mouth and Renying.

  • PDF

Properties of Inductively coupled Ar/CH4 plasma based on plasma diagnostics with fluid simulation

  • Cha, Ju-Hong;Son, Ui-Jeong;Yun, Yong-Su;Han, Mun-Gi;Kim, Dong-Hyeon;Lee, Ho-Jun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.210.2-210.2
    • /
    • 2016
  • An inductively coupled plasma source was prepared for the deposition of a-C:H thin film. Properties of the inductively coupled plasma source are investigated by fluid simulation including Navier-Stokes equations and home-made tuned single Langmuir probe. Signal attenuation ratios of the Langmuir probe harmonic frequency were 13.56Mhz and 27.12Mhz. Dependencies of plasma parameters on process parameters were accord with simulation results. Ar/CH4 plasma simulation results shown that hydrocarbon radical densities have their lowest value at the vicinity of gas feeding line due to high flow velocity. For input power density of 0.07W/cm3, CH radical density qualitatively follows electron density distribution. On the other hand, central region of the chamber become deficient in CH3 radical due to high dissociation rate accompanied with high electron density. The result suggest that optimization of discharge power is important for controlling deposition film quality in high density plasma sources.

  • PDF