• 제목/요약/키워드: power factor correction (PFC)

검색결과 315건 처리시간 0.038초

KTX 고속전철 추진제어시스템의 역률제어장치(PFC) 동작특성 분석 (Dynamic Characteristics Analysis on the Power Factor Correction (PFC) System for Propulsion System of KTX High Speed Train)

  • 이을재;이은규;윤차중
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.82-92
    • /
    • 2011
  • This paper presents a PFC(Power Factor Correction) system to control the power factor of input current of the converter system which is working in the propulsion system of KTX high speed train. In the KTX train system, initially introduced from ALSTOM, the thyristor converter with phase controlling technique is adopted in the current fed type powering system. The input current induces harmonic losses highly because the waveform becomes rectangular shapes according to the filter inductor current increased as the train speed increasing gradually. Especially the interference with the signalling systems is severe concerned due to high current harmonics on the catenary line. To protect this problem, a frequency trap filter(notch filter) is operating with the input converter system. In this paper, an analysis work and PC simulation have been done on the PFC system to upgrade its performance and maintenance efficiency.

  • PDF

단일 PWM 제어기에 의한 역률보상 이단 풀 브리지 컨버터에 관한 연구 (A Study on Two Stage PFC Full-Bridge Converter with a Single PWM Controller)

  • 전준상;김용;권순도;김필수;윤석호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 B
    • /
    • pp.368-371
    • /
    • 2000
  • Two-stage power factor correction (PFC) converter with a single PWM controller is proposed. It consists of a power factor pre-regulator cascaded by an isolated DC/DC converter as in a conventional two-stage approach. However, a single PWM controller is used as in a single-stage, single-switch PFC approach. This converter gives the goof power factor correction, low line current harmonic distortions, and tight output voltage regulations. This converter also has a high efficiency by employing an soft switching method. The proposed approach has advantages such as high performance over the single-stage approach and low cost over two-stage approach. The experimental results obtained on a 300W (30V/10A) prototype PFC converter are given to verify the effectiveness of the proposed control method.

  • PDF

부스트 방식 역률개선회로의 설계와 특성분석 (Analysis of continuous conduction mode boost power-factor-correction circuit)

  • 김철진;장준영;김상덕;송요창;윤신용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.1120-1122
    • /
    • 2002
  • Switching power supply are widely used in many industrial field. Power factor improvement and harmonic reduction technique is very important in switching power supply. The power factor correction (PFC) circuit using boost converter used in input of power source is studied in this paper. It is analyzed distortional situations and harmonics of input currents that presented at continuous conduction mode(CCM) of boost PFC circuit. It is done simulations of harmonics distribution according to load variation by using PSPICE and MATLAB. From the actual experiment of boost PFC circuit the validity of the analysis is confirmed.

  • PDF

Novel Zero-Voltage-Switching Bridgeless PFC Converter

  • Haghi, Rasool;Zolghadri, Mohammad Reza;Beiranvand, Reza
    • Journal of Power Electronics
    • /
    • 제13권1호
    • /
    • pp.40-50
    • /
    • 2013
  • In this paper, a new zero-voltage-switching, high power-factor, bridgeless rectifier is introduced. In this topology, an auxiliary circuit provides soft switching for all of the power semiconductor devices. Thus the switching losses are reduced and the highest efficiency can be achieved. The proposed converter has been analyzed and a design procedure has been introduced. The control circuit for the converter has also been developed. Based on the given approach, a 250 W, 400 Vdc prototype converters has been designed at 100 kHz for universal input voltage (90-264 Vrms) applications. A maximum efficiency of 94.6% and a power factor correction over 0.99 has been achieved. The simulation and experimental results confirm the design procedure and highlight the advantages of the proposed topology.

연속-불연속 경계 모드에서 동작하는 승압형 역률보상회로의 평균화 모델 (Averaged Model for Controlled On-Time Boost Power Factor Correction Circuit)

  • 박효길;최병조;백영식
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.126-129
    • /
    • 1999
  • This paper presents a new averaged model for controlled on time boost power factor correction (PFC) circuit. The proposed model accurately predicts the average behavior of the PFC circuit, and offers a good alternative in studying the large signal dynamics of the circuit. The accuracy of the model is verified through both computer simulation and experiments.

  • PDF

SMALL-SIGNAL MODEL FOR A CONTROLLED ON-TIME BOOST POWER FACTOR CORRECTION CIRCUIT

  • Kang, Yonghan;Choi, Byungcho
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.642-647
    • /
    • 1998
  • A new small-signal model for the controlled on-time boost power factor correction (PFC) circuit is presented. The proposed small-signal model is valid up to high frequencies over lKHz. The model can be used in designing the voltage feedback compensation of PFC circuits, the control bandwidth of which is maximized with auxiliary means of removing the low-frequency ripple from the output. The accuracy of the model is confirmed by a 200W experimental hardware

  • PDF

새로운 CCM 단일 전력단 역률보상 풀 브리지 컨버터 (New CCM Single Stage PFC Full Bridge Converter)

  • 임창섭;권순걸;조정구;송두익
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.986-989
    • /
    • 2002
  • This paper proposes a new single stage power factor correction (PFC) full bridge converter which operates at continuous conduction mode(CCM). The proposed single stage PFC consists of typical zero voltage switching(ZVS) full bridge DC/DC converter, two transformer auxiliary windings, and two small inductors, and two diodes. Neither additional active switch nor any control circuit are added for PFC resulting in very low cost. The proposed converter provides input power factor correction with CCM control and tight output voltage regulation. All switching devices are operated under ZVS with minimum voltage stress. Operation principle and analysis are explained and verified with computer simulation and experimental results on a 1.2kW, 100kHz prototype.

  • PDF

PFC 기능 통합형 단일 전력단 LLC Converter (Single Power Stage LLC Converter With Power Factor Correction Integration)

  • 김상연;강경수;김다솜;최윤석;노정욱
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2016년도 전력전자학술대회 논문집
    • /
    • pp.153-154
    • /
    • 2016
  • 기존 단상 AC 전원용 LLC 컨버터는 250W의 조건에서는 PFC (Power-Factor Correction, 약칭 PFC) 회로를 채용하는 것이 일반적이다. 그러나 이러한 2단 전력단 형태의 회로는 자성체(인덕터) 및 제어기의 사용이 필수적이며, 이는 회로 부피 및 원가 상승의 주요한 원인이 된다. 본 논문은 DM Choke와 차지 펌프를 적용해 회로의 역률을 개선하는 방안을 제안하여, PFC Stage를 삭제하고 역률 개선 기능을 통합한 단일 전력단 LLC 컨버터를 제안한다. 본 논문에서는 제안한 회로를 이론적으로 분석하고, 190W급의 시작품을 이용한 실험적 분석을 통해 실용 가능성을 검증하였다.

  • PDF

Modulated Carrier Control for Interleaved Continuous Conduction Mode(CCM) Boost Power Factor Correction Converter

  • Kim, Hye-jin;Choi, Kyu-sik;Cho, B.H.;Choi, Hang-seok
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 전력전자학술대회 논문집
    • /
    • pp.195-196
    • /
    • 2012
  • In recent years, in an effort to improve the efficiency and the power density of the front-end power factor correction(PFC), the interleaving of multiple converter is employed. The conventional interleaved continuous conduction mode(CCM) boost PFC converter requires input and output voltage sensing and three current sensing to obtain current balancing between modules. In this paper, the interleaved CCM PFC converter based on modulated carrier control is proposed. With the proposed method, two phase interleaved PFC can be realized simply without line voltage sensing resistor and can achieve current balancing without additional current sensing resistor on common return path. The simulation studies are carried out to verify the effectiveness of the proposed control scheme.

  • PDF

수동역률 개선회로를 이용한 110/220V 겸용 정출력 안정기 개발 (The development of 110/220V alternative static output ballast by using passive power factor correction circuit)

  • 송명석;조계현;박종연
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 춘계학술대회 논문집
    • /
    • pp.210-213
    • /
    • 2004
  • In this paper, we propose the passive PFC(Power Factor Correction) circuit of an electronic ballast with the constant power the detection circuit for 110 or 220 volt. The proposed PFC circuit is composed with the modified dither circuit and the input voltage detection circuit. We have concluded that the proposed method is the attractive method to improve of power factor for the electronic ballast with the input voltage regulation and it is a similar experimental results with other active power factor correction method using other PWM ICs.

  • PDF