• Title/Summary/Keyword: power conversion system

Search Result 1,264, Processing Time 0.033 seconds

A High Efficient Piezoelectric Windmill using Magnetic Force for Low Wind Speed in Wireless Sensor Networks

  • Yang, Chan Ho;Song, Yewon;Jhun, Jeongpil;Hwang, Won Seop;Hong, Seong Do;Woo, Sang Bum;Sung, Tae Hyun;Jeong, Sin Woo;Yoo, Hong Hee
    • Journal of the Korean Physical Society
    • /
    • v.73 no.12
    • /
    • pp.1889-1894
    • /
    • 2018
  • An innovative small-scale piezoelectric energy harvester has been proposed to gather wind energy. A conventional horizontal-axis wind power generation has a low generating efficiency at low wind speed. To overcome this weakness, we designed a piezoelectric windmill optimized at low-speed wind. A piezoelectric device having high energy conversion efficiency is used in a small windmill. The maximum output power of the windmill was about 3.14 mW when wind speed was 1.94 m/s. Finally, the output power and the efficiency of the system were compared with a conventional wind power system. This work will be beneficial for the piezoelectric energy harvesting technology to be applied to the real world such as wireless sensor networks (WSN).

Analysis of RF-DC Conversion Efficiency of Composite Multi-Antenna Rectifiers for Wireless Power Transfer

  • Deng, Chao;Huang, Kaibin;Wu, Yik-Chung;Xia, Minghua
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.11 no.10
    • /
    • pp.5116-5131
    • /
    • 2017
  • This paper studies the radio frequency to direct current (RF-DC) conversion efficiency of rectennas applicable to wireless power transfer systems, where multiple receive antennas are arranged in serial, parallel or cascaded form. To begin with, a 2.45 GHz dual-diode rectifier is designed and its equivalent linear model is applied to analyze its output voltage and current. Then, using Advanced Design System (ADS), it is shown that the rectifying efficiency is as large as 66.2% in case the input power is 15.4 dBm. On the other hand, to boost the DC output, three composite rectennas are designed by inter-connecting two dual-diode rectifiers in serial, parallel and cascade forms; and their output voltage and current are investigated using their respective equivalent linear models. Simulation and experimental results demonstrate that all composite rectennas have almost the same RF-DC conversion efficiency as the dual-diode rectifier, yet the output of voltage or current can be significantly increased; in particular, the cascade rectenna obtains the highest rectifying efficiency.

Design and Development of a High-Voltage Transformer-less Power Supply for Ozone Generators Based on a Voltage-fed Full Bridge Resonant Inverter

  • Amjad, Muhammad;Salam, Zainal;Facta, Mochammad;Ishaque, Kashif
    • Journal of Power Electronics
    • /
    • v.12 no.3
    • /
    • pp.387-398
    • /
    • 2012
  • It is known that transformer based power supplies for ozone generators have low efficiency, high cost and exhibits a limited frequency range of operation. To overcome these disadvantages, this paper proposes a high frequency ozone generator with the absence of a transformer. The voltage step-up is achieved only by utilizing the resonant tank. This is made possible by a novel combination of ozone chamber materials that allow ozone to be generated at only 1.5 - 3.5 $kV_{p-p}$. The input to the resonant tank is driven by a PWM full bridge resonant inverter. Furthermore, zero-current zero-voltage switching (ZCZVS) operation is achieved by employing a duty factor of 25% between the switches of the full bridge. The advantages of the proposed system include high efficiency, low cost and the ability to control ozone production by varying the input voltage to the inverter. The prototype is verified by both simulation and experimental results.

A Study on the Compensation of Reactive Power by Power MOSFET INVERTER (전력용 MOSFET Inverter에 의한 무방전력보상에 관한 연구)

  • 이계호;김동필
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.36 no.3
    • /
    • pp.163-170
    • /
    • 1987
  • It is known that reactive component of AC power in the power system gives no energy to outside and cuses enlargiment of power apparatus, voltage fluctuation and unstability of power system. The power conversion system and control system which are composed of power semiconductor devices such as tyristor, transistor, GTO and so on have been appeared as new sources of reactive power. So the cmpensation of reactive power in power semiconductor systems is one of impending problem on the point of energy conservation and inprovement of power factor. This paper treates the fundamental review of the current type power compensation system that compensates the reactive power by MOSFET inverter. This inverter detects not only the reactive power of fundamental wave but also that of all harmoics created in the power semiconductor system and is scheduled to control by sampled value.

  • PDF

Characteristic of Three-Phase Voltage Type Soft-Switching Inverter using the Novel Active Auxiliary Resonant DC Link Snubber (새로운 액티브 보조 공진 DC 링크 스너버를 이용한 3상 전압형 소프트 스위칭 인버터의 특성)

  • Sung, Chi-Ho;Heo, Young-Hwan;Mun, Sang-Pil;Park, Han-Seok
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.65 no.2
    • /
    • pp.114-121
    • /
    • 2016
  • This paper is Instant space vector PWM(Pulse Width Modulation)power conversion devices in switching power semiconductors from my generation to losses and switching when the voltage surge and current surge of electronic noise(EMI: Electro Magnetic Interference / RFI: Radio Frequency Interference)to effectively minimize the power soft-switching power conversion circuit topologies of auxiliary resonant DC tank for the purpose of high performance realization of the electric power conversion system by the high-speed switching of a semiconductor device(AQRDCT simultaneously : an active auxiliary resonance using auxiliary Quasi-resonant DC tank)DC link snubber switch has adopted a three-phase voltage inverter. AQRDCL proposed in this paper can reduce the effective and current peak stress of the power semiconductors of the auxiliary resonant snubber circuit compared to the conventional active-resonant DC link snubber, it is not necessary to install the clamp switch of the auxiliary resonant DC link, DC the peak current and power loss of the bus line can be reduced.

The Characteristics of Planar EMI Filter with Bi-Ground Layers Considering Impedance Mismatching

  • Wang, Shishang;Song, Zheng;Lou, Qianceng
    • Journal of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.1200-1208
    • /
    • 2016
  • Planar electromagnetic interference (EMI) filter has significant engineering significance to power electronic system integration and miniaturization. However, the value of differential mode capacitance cannot meet the demand of noise suppression because of the size limit of ceramics. In this case, the EMI filter of novel multilayers is recommended to address this issue. A novel integrated structure of EMI filter based on multilayer ceramic is proposed in this study. The inductance and capacitance of the new structure can be designed separately, which is an advantage in manufacturing. Insertion loss is measured more closely to the actual situation in this study, which is different from the condition where source and load impedances are both 50 Ω. In the process of designing a novel EMI filter, noise impedance is considered. Moreover, the prototype is created and applied to a small switching power supply, which verifies the effectiveness of the developed EMI filter.

A Comparison Study on Mechanical Properties of XLPE Insulation Thermally Degraded at Equivalent and Variable Temperature Conditions (XLPE 절연체의 등가 및 가변온도 가속열화실험을 통한 기계적 특성 비교 분석)

  • Taejoon, Kim;Jae-Sang, Hwang;Sung Hoon, Jung;Tae Young, Kim
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.8 no.2
    • /
    • pp.73-77
    • /
    • 2022
  • Recently, as the number of years of operation has increased for more than 30 years, interest in evaluating the remaining life of major power facilities such as transformers and ultra-high voltage cables is increasing. In particular, the risk of failure is increasing because the underground transmission XLPE cable has been built since 1980 and has been operating in excess of 30 years of design life or close proximity. Therefore, it is necessary to develop an algorithm to evaluate the residual life of the XLPE cable considering the load to determine the risk of failure. Since load data is large amount of data, it is necessary to make the variable load information equivalent to the time unit first in order to calculate the remaining life of the system quickly. In overseas literature, transformers are reported to be standardized for variable load equivalent conversion formulas, but they have not been reported for ultra-high voltage cables. Therefore, in this paper, whether the equivalent conversion formula of a transformer can be applied to XLPE cables was reviewed through accelerated degradation tests under equivalent and variable temperature conditions, and considerations were studied when evaluating the remaining operating life of XLPE cables based on the experimental results.

Modeling of Load Element for a Low Voltage DC Distribution System (저전압 DC 배전시스템 구성요소의 부하 모델링)

  • Gwon, Gi-Hyeon;Han, Joon;Oh, Yun-Sik;Kim, Eung-Sang;Kim, Chul-Hwan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.6
    • /
    • pp.113-121
    • /
    • 2014
  • At the end of the 19th century, a battle known as the War of the Currents was fought over how electricity would be generated, delivered, and utilized. In this day and age, there has been a growing interest in Green Growth policies as countermeasures against global warming. As a result of these policies, the use of new and renewable energy needed a power converter to replace fossil fuels has expanded. To reduce power consumption through high efficiency of conversion, Low Voltage DC (LVDC) distribution systems are suggested as an alternative. In a DC distribution system, DC loads are very efficient due to decrease the stages of power conversion. If the LVDC distribution system is adopted, not only DC load but also existing AC loads should be connected with LVDC system. Thus, the modeling of two loads is needed to analyze the DC distribution system. This paper, especially, is focused on the modeling of resistive load and electronic load including power electronic converters using ElectroMagnetic Transient Program (EMTP) software.

Development of Grid Connection Type Inverter for 30kW Wind Power Generation System (30kW급 발전시스템의 계통 연계형 인버터 개발)

  • Hahm, Nyeon-Kun;Kang, Seung-Ook;Kim, Yong-Joo;Han, Kyong-Hee;Ahn, Gyu-Bok;Song, Seung-Ho;Kim, Dong-Yong;Rho, Do-Hwan;Oh, Young-Jin
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.990-992
    • /
    • 2002
  • 30kW electrical power conversion system is delveloped for the variable speed wind turbine system. In the wind energy conversion system(WECS) a synchronous generator with field current excitation converts the mechanical energy into electrical energy. As the voltage and frequency of generator output vary according to the wind speed, a dc/dc boosting chopper is utilized to maintain constant dc link voltage. Grid connection type PWM inverter supply currents into the utility line by regulating the dc link voltage. The active power is controlled by q-axis current which the reactive power can be controlled by d-axis current reference change. The phase angle of utility voltage is detected using s/w PLL(Phased Locked Loop) in d-q synchronous reference frame. This scheme gives a low cost power solution for variable speed WECS.

  • PDF

A Study on The Effect of Power conversion system for De-wiring Trolley wire by Electric Railway System (전기철도 전차선 이선이 전력변환장치에 미치는 영향 연구)

  • Shin, Seung-Chul;Kim, Jae-Chul;Han, Seong-Ho;Lee, Su-Gil
    • Proceedings of the KIEE Conference
    • /
    • 2006.11a
    • /
    • pp.381-383
    • /
    • 2006
  • A de-wiring trolley wire usually makes the electrical system complex and may have an adverse effect on the electrical system inside the train. It is important to analyze the effect on trains in de-wiring trolley wire. we accomplished an equivalent model of the electric train system. We used PSCAD/EMTDC, an electromagnetic transient program. The result of this study can be used as a facility design to use a power conversion system filter and needs to prove through actual field data in the main circuit of an electric train for a precise analysis about effect of de-wiring.

  • PDF