• Title/Summary/Keyword: positions

Search Result 6,435, Processing Time 0.039 seconds

Wall flow characteristics with static mixer position and housing geometry for preventing urea-salt deposition (우레아염 퇴적 방지를 위한 믹서 위치 및 하우징 형상에 따른 벽면 유동특성에 관한 연구)

  • Lee, Banguk;Lee, Jeekeun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.4
    • /
    • pp.368-377
    • /
    • 2013
  • The Urea-SCR system commercialized shows a remarkable performance to reduce NOx emission in heavy duty diesel engines. However, Urea-water solution injected upstream a mixer, which is set up inside a exhaust pipe to promote exhaust gas-atomized droplet mixing, bumps up against the wall of a exhaust pipe as the droplets flow downstream through the exhaust gas. The urea deposited on the wall of the exhaust pipe is changed into the Urea-salt, resulting in the decreased life-time of the SCR catalysts. Therefore, the development of the urea deposition avoidance technologies is being treated as an important issue of the Urea-SCR systems. An experimental study was carried out to investigate the effects of the wall flow characteristics around the mixer-housing assembly with the variation of the mixer housing surrounding and supporting the mixer, which is designed to increase the wall flow and then to reduce droplet deposition. The flow characteristics was investigated by using a hot-wire anemometry for 2-D simplified duct model, and the housing tilt angles and the position of the mixer were changed : angle of $0^{\circ}$, $1^{\circ}$, $2^{\circ}$, $3^{\circ}$, and mixer positions of 0L, 0.5L, 1L. The results showed that the wall flow onto the exhaust pipe was improved with changing the tilt angle of the mixer housing, and the wall flow improved more when the position of the mixer was on 1L.

Development of Ideal Model Based Optimization Procedure with Heuristic Knowledge (정위적 방사선 수술에서의 이상표적모델과 경험적 지식을 활용한 수술계획 최적화 방법 개발)

  • 오승종;송주영;최경식;김문찬;이태규;서태석
    • Progress in Medical Physics
    • /
    • v.15 no.2
    • /
    • pp.84-93
    • /
    • 2004
  • Stereotactic radiosurgery (SRS) is a technique that delivers a high dose to a target legion and a low dose to a critical organ through only one or a few irradiations. For this purpose, many mathematical methods for optimization have been proposed. There are some limitations to using these methods: the long calculation time and difficulty in finding a unique solution due to different tumor shapes. In this study, many clinical target shapes were examined to find a typical pattern of tumor shapes from which some possible ideal geometrical shapes, such as spheres, cylinders, cones or a combination, are assumed to approximate real tumor shapes. Using the arrangement of multiple isocenters, optimum variables, such as isocenter positions or collimator size, were determined. A database was formed from these results. The optimization procedure consisted of the following steps: Any shape of tumor was first assumed to an ideal model through a geometry comparison algorithm, then optimum variables for ideal geometry chosen from the predetermined database, followed by a final adjustment of the optimum parameters using the real tumor shape. Although the result of applying the database to other patients was not superior to the result of optimization in each case, it can be acceptable as a plan starling point.

  • PDF

Observation of Ignition Characteristics of Coals with Different Moisture Content in Laminar Flow Reactor (층류 반응기를 이용한 수분함량에 따른 석탄 휘발분의 점화 특성에 관한 연구)

  • Kim, Jae-Dong;Jung, Sung-Jae;Kim, Gyu-Bo;Chang, Young-June;Song, Ju-Hun;Jeon, Chung-Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.5
    • /
    • pp.451-457
    • /
    • 2011
  • The main objective of this study is to investigate the variation in the ignition characteristics of coals as a function of moisture content in a laminar flow reactor (LFR) equipped with a fuel moisture micro-supplier designed by the Pusan Clean Coal Center. The volatile ignition position and time were observed experimentally when a pulverized coal with moisture was fed into the LFR under burning conditions similar to those at the exit of the pulverizer and real boiler. The reaction-zone temperature along the centerline of the reactor was measured with a $70-{\mu}m$, R-type thermocouple. For different moisture contents, the volatile ignition position was determined based on an average of 15 to 20 images captured by a CCD camera using a proprietary image-processing technique. The reaction zone decreased proportionally as a function of the moisture content. As the moisture content increased, the volatile ignition positions were 2.92, 3.36, 3.96, and 4.65 mm corresponding to ignition times of 1.46, 1.68, 2.00, and 2.33 ms, respectively. These results indicate that the ignition position and time increased exponentially. We also calculated the ignition-delay time derived from the adiabatic thermal explosion. It showed a trend that was similar to that of the experimental data.

Enhancement of the Performance a Centrifugal Compressor in an Automobile Turbocharger by Modifying the Circumferential Inlet Height of Volute (원주방향 볼류트 입구 높이를 수정한 자동차용 터보차저 원심압축기의 성능 향상)

  • Zhou, Tianjun;Lee, Geun Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.2
    • /
    • pp.115-120
    • /
    • 2014
  • To enhance the performance of an automobile turbocharger compressor, the circumferential inlet heights of the volute were modified and the flow field for the combined region of the diffuser and volute was numerically investigated using commercial software. Basically, a well-designed volute should have a high pressure recovery coefficient and a low loss coefficient for the total pressure. In this study, two circular volutes with the same cross sectional shape and tongue angle, but circumferentially different volute inlet heights, were selected. One volute had the middle inlet in the cross-section at the circumferential angle of $90^{\circ}$ but gradually lower inlet heights for the angles between $90^{\circ}$ to $360^{\circ}$ with respect to the cross sectional center of the volute, while maintaining the same height between the tangential line connecting the lowest positions of the cross section and the line connecting the volute inlets in the circumferential direction (case 1 volute). The other volute has an inlet height that is 2 mm lower than in case 1 volute such that the tongue section has a tangential inlet (case 2 volute). The results showed that the case 2 volute had a higher total pressure ratio because of its higher pressure recovery coefficient and higher isentropic efficiency, resulting from the lower loss coefficient along the circumferential position than the case 1 volute.

Optimization of Dose Distribution for High Dose Rate Intraluminal Therapy (고선량율 관내 방사선치료를 위한 종양선량분포의 최적화에 대한 연구)

  • Chu, Sung-Sil;Kim, Gwi-Eon;Loh, Juhn-Kyu
    • Radiation Oncology Journal
    • /
    • v.12 no.2
    • /
    • pp.243-252
    • /
    • 1994
  • The use of high dose rate remote afterloading system for the treatment of intraluminal lesions necessitates the need for a more accurate of dose distributions around the high intensity brachytherapy sources, doses are often prescribed to a distance of few centimeters from the linear source, and in this range the dose distribution is very difficult to assess. Accurated and optimized dose calculation with stable numerical algorithms by PC level computer was required to treatment intraluminal lesions by high dose rate brachytherapy system. The exposure rate from sources was calculated with Sievert integral and dose rate in tissue was calculated with Meisberger equation, An algorithm for generating a treatment plan with optimized dose distribution was developed for high dose rate intraluminal radiotherapy. The treatment volume becomes the locus of the constrained target surface points that is the specified radial distance from the source dwelling positions. The treatment target volume may be alternately outlined on an x-ray film of the implant dummy sources. The routine used a linear programming formulism to compute which dwell time at each position to irradiate the constrained dose rate at the target surface points while minimizing the total volume integrated dose to the patient. The exposure rate and the dose distribution to be confirmed the result of calculation with algorithm were measured with film dosimetry, TLD and small size ion chambers.

  • PDF

Anatomical Study of Superficial Peroneal Nerve Accessory Artery and Perforators in the Anterior Intermuscular Septum of Lower Leg Using Cadaveric Dissection (시체 해부를 통한 다리의 얕은종아리신경 동반동맥과 앞근육사이막에 존재하는 관통가지에 관한 해부학적 연구)

  • Kim, Jun Sik;Shin, Sang Ho;Choi, Tae Hyun;Lee, Kyung Suk;Kim, Nam Gyun
    • Archives of Plastic Surgery
    • /
    • v.33 no.6
    • /
    • pp.695-699
    • /
    • 2006
  • Purpose: In the 1990s, skin island flap supplied by the vascular axis of the sensitive superficial nerves had been introduced. For example, neurocutaneous flaps supplied by the vascular axis of the sural nerve and saphenous nerve have been used. But the flap supplied by the vascular axis of superficial peroneal nerve has not been used commonly. Because there have been few anatomical reports about the superficial peroneal nerve accessory artery(SPNAA), we could not apply the neurocutaneous flap supplied by SPNAA. The aim of this study is to investigate the anatomy of SPNAA, number and location of its perforators, and septocutaneous perforators from the anterior tibial artery in anterior intermuscular septum. Methods: So, we dissected a total of eight cadavers. Measurements were made of the positions of the dissected arteries and perforators from the head of the fibula. Results: In all cadavers the superior lateral peroneal artery was originated from the anterior tibial artery and contributed SPNAA. Arising from the anterior tibial artery an average of 5.63 cm inferior to the fibular head, it varied from 10 cm to 16 cm in length. SPNAA gave off an average of 4.38 perforators to supply lateral aspect. In one case the inferior lateral peroneal artery was present and arose from the anterior tibial artery 18 cm inferior to the fibular head. There were an average of 3.38 direct septocutaneous perforators from the anterior tibial artery. Conclusion: Septocutaneous perforators from SPNAA mainly exist from proximal 1/6 to 3/5 of lower leg. In the distal 1/3 of lower leg where the accessory artery was disappeared, exist mainly direct septocutaneous perforators from the anterior tibial artery. Our results can be helpful to applications of the neurocutaneous flap using SPNAA or fasciocutaneous flap based on direct septocutaneous perforators.

Comparison of Characteristics of Hepatic Microsomal Cytochrome P45O-dependent Monooxygenases from Snake and Rat (꽃뱀과 흰쥐의 간 마이크로좀에 존재하는 Cytochrome P45O 의존성 Monooxygenases의 특성 비교)

  • Ja Young Moon;Dong Wook Lee;Ki Hyun Park
    • Journal of Life Science
    • /
    • v.8 no.6
    • /
    • pp.695-701
    • /
    • 1998
  • This study was carried out to investigate levels of the components of microsomal mixed function oxidase (MFO) system and activities of the hepatic microsomal cytochrome P45O (P45O)-dependent monooxygenases of grass snake (Natrix tigrina Lateralis) and to compare with those of rat. The levels of P45O and cytochrome b$_{5}$, (b$_{5}$) of snake were much lower than those in rat. NADPH-cytochrome c reductase activity in the snake was also only 40% of that in the rat. Activities of 7-ethoxycoumarin 0-deethylase (ECOD) and benzphetamine N-demethylase (BPDM) of snake hepatic microsomes, when compared with those of rat, were markedly low. But, aryl hydrocarbon hydroxylase (AHH) and testosterone hydroxylase (TSH) activities were nearly the same or higher than those of the rat. Of the P45O-dependent TSHs measured, 7$\alpha$-hydroxylase activity was the highest in snake, whereas, 6$\beta$-hydroxylase activity was the highest in rat. However, stereoselectivity of the enzyme from the snake to C2 and C6 positions of testoste-rone was the same as rat. The result of radioimmunoassay (RIA) for the identification of five P45O isozymes with MAbs shows that relatively high content of ethanol-inducible P45O isozyme, CYP2El, exists in the rat, whereas MC-inducible P45O isozyme, CYP2A1/1A2, does in the snake. From the analyses of SDS-PAGE and RIA of partially pu-rified P45O, we suggest the possibility of the presence of a certain P45O isozyme(s) in hepatic microsomes of snake different from those of rat.

  • PDF

Effect of Leaf Maturity on Physico -chemical Properties of Leaf Tobacco (담배 잎의 성숙도에 따른 이화학적 특성)

  • 이철환;진정의;한철수
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.41 no.2
    • /
    • pp.200-206
    • /
    • 1996
  • Experiment was conducted to get the information about physico-chemical properties of flue-cured tobacco on the degree of maturity cultivated in paddy-upland rotated field, and compared to upland ones. For the samples of this experiment, 3~4 leaves at each stalk position were harvested from the bottom of plants. Physico-chemical properties of cured leaves were determined from the samples collected at weekly intervals, and of obtained from 4 stalk positions. For the degree of maturity, harvested leaves were separated with visual characters into four classes such as immature, mature, ripe, and mellow. Regardless of stalk position, the order of shrinkage rate with length and width of leaves was mellow> immature> ripe> mature, and ripe leaves from paddy field showed higher shrinkage rate than those of upland. Nicotine and total nitrogen contents were decreased with the degree of maturity while reducing sugar content were showed a reverse tendency. Ripe leaves from paddy field had lower reducing sugar contents, comparing with upland tobacco. Filling capacity of cured leaves from paddy field was decreased with degree of maturity, but there was no difference between upland and paddy tobacco. Shatter index was increased in the oeder of immature > mellow > mature > ripe. Chemical components of cigarette smoke from paddy field tobacco were little higher in $CO_2$ total particulate matter and tar contents, while combustibility was little lower than that of upland tobacco. It was also evaluated that paddy field tobacco was unfavorable for the non-volatile organic and higher fatty acids contents comparing with upland tobacco.

  • PDF

Occurrence and Genetic Environments of Quartz Veins from the Jukwangri area, Hwawon-myeon, Jeollanamdo, Republic of Korea (전남 화원면 주광리일대 석영맥의 산상 및 생성환경)

  • Yoo, Bong-Chul;Lee, Hyun-Koo;Choi, Dong-Ho
    • Economic and Environmental Geology
    • /
    • v.39 no.6 s.181
    • /
    • pp.653-662
    • /
    • 2006
  • Quartz veins from the Jukwangri area of Hwawon-myeon are epithermal quartz veins that are filling the NW or NE-trending faults within Precambrian metasedimentary rocks. Based on their prolongation and ore grades, No. 1 quartz vein can be traced for about 200 m and varies 0.1 to 3 m in thickness. Mineralization of No. 1 quartz vein can be divided into hypogene and supergene stages. Hypogene stage is associated with hydrothermal alteration minerals(phyllic and argillic zones) such as illite, sericite and sulfides such as pyrite, arsenopyrite, sphalerite. chalcopyrite, galena, argentian tetrahedrite. Supergene stage is composed of Fe-Mn oxide, Zn-Fe oxide and Pb oxide. Fluid inclusion data indicate that homogenization temperature and salinity of hypogene stage range from 187 to $306^{\circ}C$ and ken 0.0 to 6.2 wt.% eq. NaCl, respectively. They suggest that ore forming fluids were progressively cooled and diluted from mixing with meteoric water. Oxygen($-4.1{\sim}4.1%o$) and hydrogen($-107{\sim}-88%o$) isotope com-positions indicated that hydrothermal fluids were derived from meteoric and evolved by progressive mixing with meteoric water during mineralization.

Helicobacter pylori Strain 51 (Korean Isolate): Ordered Overlapping BAC Library, Combined Physical and Genetic Map, and Comparative Analysis with H. pylori Strain 26695 and Strain J99

  • KANG HYUNG-LYUN;LEE WOO-KON;SONG JAE-YOUNG;CHOI SANG-HAENG;PARK SEONG-GYU;RYU BOK-DEOK;LEE EUN-JOO;KIM JI-SUN;PARK JEONG-UCK;BAIK SEUNG-CHUL;CHOI MYOUNG-BUM;YOUN HEE-SHANG;KO GYUNG-HYUCK
    • Journal of Microbiology and Biotechnology
    • /
    • v.15 no.4
    • /
    • pp.844-854
    • /
    • 2005
  • We constructed a defined physical and genetic map of H. pylori strain 51, previously isolated from a Korean patient with a duodenal ulcer, by combining a restriction analysis by pulse-field gel electrophoresis with the construction of a BAC library. A Notl-digest of H. pylori strain 51 genome yielded seven fragments, from which the genomic size was estimated to be 1,698$\pm$24 kb. The BAC library was constructed from 50 to 200 kb fragments of HindIII-digested genomic DNA. From 700 BAC clones, an ordered overlapping maxi-set of 82 BAC clones was assembled that covered the entire genome. The positions of 15 genes were localized in the strain 51 genome with 4-22 kb of resolution and were compared with their orthologues in strain 26695 and strain J99. The arrangement of the 15 genes was identical in strain 51 and strain J99, except for flaA and hpaA. The plasticity zone of strain 51, like that of strain J99, was located in the single region, and was shorter than those of strain 26695 and strain J99. The strain 51 plasticity zone consisted of ORFs common only to strain 51 and J99 or to strain 51 and 26695, as well as strain 51-specific ORFs. Three genetic translocations and/or inversions were found between orthologue ORFs in strain 51 and strain J99. These results show that the chromosomal organization of strain 51 differs from Western strains such as strain 26695 and strain J99.