• 제목/요약/키워드: portable measurement device

검색결과 98건 처리시간 0.027초

휴대용 혈중pH 측정시스템의 구현 (Development of Portable System for Measuring pH in Blood)

  • 정도운;김우열;배진우;강성철;심윤보;전계록
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 하계종합학술대회 논문집(5)
    • /
    • pp.195-198
    • /
    • 2001
  • We developed the portable blood analysis system, which can be measured pH of the blood. This system is composed to electronic circuit, mechanism, and system software. Electronic circuit is composed to the sensor, pre-amp part, temperature regulation part, fluid sensing part, A/D(analog to digital) conversion part, main and peripheral device processing part. And the mechanism is composed to the flow cell and the liquid flow part. The liquid flow part is consisted of blood and washing control system under the control of the 6-channel solenoid valve and syringe rump. The system software is composed to measurement program, calibration program, washing and diagnostic program. The program of each routine is designed as sequential process for an efficiency. And the portable pH analysis system used two-point calibration method using the two types of corrective liquid. As a result, we obtained the calibration curve and calculated the value of pH. For verifying the system, we confirmed the output voltage of the sensor, and estimated reappearance of system using the standard liquid.

  • PDF

A Prototype System for Early-Stage Breast Cancer Detection

  • Yi, Guk-Jin;Kang, Woo-Geun;Kim, Hyuk-Je;Jeon, Soon-Ik;Pack, Jeong-Ki
    • Journal of electromagnetic engineering and science
    • /
    • 제15권3호
    • /
    • pp.158-166
    • /
    • 2015
  • The early detection of breast cancer is very important. The final goal of this study is to develop an inexpensive portable device for simply detecting the existence of breast cancer using microwaves. In this study, we proposed a detection algorithm and the system configuration of such a device. The feasibility of the proposed method was investigated by numerical simulation and actual measurement. A prototype sensing module was fabricated, and the measurement results for tumor phantoms were presented. The measurement results showed that the prototype sensing module worked well, and the simulation results revealed that the detection rate of the device could be about 60% for a 4 mm tumor and almost 100% for a 6 mm tumor. The proposed device can be used for the self-diagnosis of breast cancer. Further study is required to reduce the size of the sensing module.

디지털경사계를 사용한 체간재위치오류 검사의 신뢰도 분석 (Analysis of Intrarater and Interrater Reliability of Trunk Repositioning Error Test using a Portable Digital Inclinometer)

  • 장우남;이경보;염준우;황병용
    • The Journal of Korean Physical Therapy
    • /
    • 제25권4호
    • /
    • pp.210-216
    • /
    • 2013
  • Purpose: A cost effective tool for the clinical measurement of trunk reposition sense is clearly needed. This study was to analyze intrarater and interrater Reliability of trunk repositioning error (TRE) test which assesses trunk position sense using a portable digital inclinometer. Methods: Twenty four normal healthy subjects were recruited. TRE was measured using a portable digital inclinometer. A digital inclinometer (Acumar-ACU360; Lafayetter Instrument) with precision to $1^{\circ}$ was placed on skin over the spinous process from first to second thoracic vertebra (T1-T2) and secured with double-sided tape. TRE test during sitting forward and lateral flexion movement was assessed. When they reached a point approximately 50% of full trunk flexion range, the examiner instructed the subjects to stop and told them. This was the target position that they should try to reproduce exactly. Each subject performed six trials. Results: ICC (2,1) for intrarater reliability (with-day and between-day) of TRE test in sagittal and frontal plane of movement was 0.75 and 0.78 (excellent reliability). Interrater reliability was 0.66 in sagittal and 0.64, frontal plane (fair to good reliability). However, there were poor correlations between an average of TRE test in sagittal and frontal plane. Conclusion: TRE test using a portable digital inclinometer demonstrated good to excellent reliability. The device may be a cost effective clinical measurement for trunk reposition sense measurement.

휴대용 수면 패턴 모니터링을 위한 복합 fNIRS-EEG 시스템 개발 (Development of a Hybrid fNIRS-EEG System for a Portable Sleep Pattern Monitoring Device)

  • 김경한;우성우;하성훈;박금룡;사커 엠디 샤힌;박배정;김창세
    • 대한의용생체공학회:의공학회지
    • /
    • 제44권6호
    • /
    • pp.392-403
    • /
    • 2023
  • This study presents a new hybrid fNIRS-EEG system to meet the demand for a lightweight and low-cost sleep pattern monitoring device. For multiple-channel configuration, a six-channel electroencephalogram (EEG) and a functional near-infrared spectroscopy (fNIRS) system with eight photodiodes (PD) and four dual-wavelength LEDs are designed. To enhance the convenience of signal measurement, the device is miniaturized into a patch-like form, enabling simultaneous measurement on the forehead. Due to its fully integrated functionality, the developed system is advantageous for performing sleep stage classification with high-temporal and spatial resolution data. This can be realized by utilizing a two-dimensional (2D) brain activation map based on the concentration changes in oxyhemoglobin and deoxyhemoglobin during sleep stage transitions. For the system verification, the phantom model with known optical properties was tested at first, and then the sleep experiment for a human subject was conducted. The experimental results show that the developed system qualifies as a portable hybrid fNIRS-EEG sleep pattern monitoring device.

이동형 X선 장치 차폐도구 제작을 통한 표면선량 분포 측정 (Measurement of Skin Dose Distribution for the Mobile X-ray Unit Collimator Shielding Device)

  • 홍선숙;김득용
    • 대한디지털의료영상학회논문지
    • /
    • 제12권1호
    • /
    • pp.5-8
    • /
    • 2010
  • Opened a court in February 10, 2006, a rule of safety management of the diagnosis radiation system was promulgated for safety of the radiation worker, patients and patients' family members. The purpose of this rule is to minimize the risk of being exposed to radiation during the process of handling X-ray. For this reason, we manufactured shielding device of mobile X-ray unit collimator for diminution of skin dose. Shielding device is made to a thickness of Pb 0.375mm. For portable chest radiography, we measured skin dose 50cm from center ray to 200cm at intervals of 20cm by Unfors Xi detector. As a result, a rule of safety management of the diagnosis radiation system has been strengthened. But there are exceptions, such as ER, OR, ICU to this rule. So shielding device could contribute to protect unnecessary radiation exposure and improve nation's health.

  • PDF

Efficient Measurement System to Investigate Micro-Doppler Signature of Ballistic Missile

  • Choi, In-O;Kim, Kyung-Tae;Jung, Joo-Ho;Kim, Si-Ho;Park, Sang-Hong
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제17권4호
    • /
    • pp.614-621
    • /
    • 2016
  • Micro-Doppler (MD) shift caused by the micro-motion of a ballistic missile (BM) can be very useful to identify it. In this paper, the MD signatures of three scale-model BMs are investigated using a portable measurement system. The measurement system consists of an X-band 2-by-2 phase comparison mono-pulse radar, and a mechanical device that can impart controlled spinning and coning motions simultaneously to a model to yield the MD signature that replicates the characteristic of each target and the corresponding micro-motion. The coning motion determined the overall period of MD, and the spinning motion increased its amplitude. MD was also dependent on aspect angle. The designed system is portable, and can implement many micro-motions; it will contribute to analysis of MD in various situations.

휴대용 단말 기반 의료용 무선 방사선 모니터링 시스템 개발 (Development of a Portable Device Based Wireless Medical Radiation Monitoring System)

  • 박혜민;홍현승;김정호;주관식
    • Journal of Radiation Protection and Research
    • /
    • 제39권3호
    • /
    • pp.150-158
    • /
    • 2014
  • 각 의료기관 내 방사선 관련 종사자나 방사선 치료환자들은 진단 및 치료 시 필연적으로 의료상 피폭을 수반하게 된다. 국제방사선방호위원회(ICRP) 권고나 국제원자력기구(IAEA)의 기준에 따라 기준선량 제약치를 적용 및 권고 받고 있지만 1차 피폭대상자인 종사자나 환자들의 피폭최적관리를 위해서는 잠재적인 피폭대상자들에게 기존의 피폭관리 시스템보다 직접적이고 가용성이 높은 측정 및 분석 방법이 필요하다. 따라서 본 연구에서는 기존에 구비된 휴대용 단말과 연동하여 원거리에서 실시간으로 방사선 모니터링이 가능한 시스템을 개발하였다. 모니터링 시스템은 검출부, 영상부, 통신부 세 부분으로 구성되었다. 검출부는 시스템의 소형화를 위해 실리콘 광증배소자(silicon photomultiplier) 기반 섬광검출기를 설계하였으며, 영상부는 무선 CCD (charge-coupled device)카메라 모듈을 사용하여 검출부와 함께 Bluetooth 통신모듈을 통해 휴대용 단말로 측정된 방사선 정보와 영상이 전송된다. 제작된 시스템은 성능 평가를 위해 진단용 X-ray 발생장치와 $^{137}Cs$, $^{22}Na$, $^{60}Co$, $^{204}Tl$, $^{90}Sr$ 선원을 사용하였다. 측정결과를 통해 개발된 시스템은 gamma, beta, X-ray에 대해서 검출 반응성을 확인하였고, 방사선 세기에 따른 응답 선형성과 MCNPX 전산코드를 이용한 측정 거리에 따른 시스템의 검출 정확도 평가 시 3% 내외의 오차범위를 확인하였다. 본 연구의 결과는 방사선 검출 시스템 구성의 비용절감 효과와 개인피폭정도관리에 기여할 것으로 기대한다.

막구조물의 막장력 측정장치 개발에 관한 연구 (Development of Measuring System of Membrane Stress for Membrane Structure)

  • 정환목;우재원;조병욱;이성연
    • 한국공간구조학회논문집
    • /
    • 제8권6호
    • /
    • pp.67-74
    • /
    • 2008
  • 본 연구는 막구조물의 장력 측정을 위한 휴대용 막장력측정기기의 개발을 목적으로 한다. 2축시험기에 장착된 막의 장력을 간이 측정기에 의해 측정하여 구한 실험 데이터를 근거로 효율적인 2축방향 막 장력측정기기를 개발하는데 그 목적이 있다. 연구결과 개발된 휴대용 간이 장력측정기기는 정량적이고 정성적인 측면에서 데이터의 정밀도가 매우 높아 향후 상용제픔으로도 개발이 가능함을 알 수 있었다.

  • PDF

이동식 배출가스 측정장비를 이용한 소형 경유 자동차의 실도로 질소산화물 배출특성 분석 (Evaluation of On-Road NOx Emission from a Light Duty Diesel Vehicle using a Portable Emissions Measurement System)

  • 이태우;이종태;김정수
    • 한국대기환경학회지
    • /
    • 제28권1호
    • /
    • pp.94-104
    • /
    • 2012
  • The purpose of this research is to quantify the compliance of on-road emission from a light duty diesel vehicle, based on a comparison to emission regulation standard. $NO_x$, CO and THC emissions were measured using a portable device on a selected real-world driving route with a length of approximately 22 km. On-road measurements were repeated by 10 times on a same route to reflect variability in traffic conditions. A test route was divided into 22 road links with length of 1 km to analyze emission results with higher spatial resolution. The average emissions of $NO_x$, CO and THC over total travel distance, which is approximately 220 km, were quantified to be in compliance with emission regulation standards. Under higher spatial resolution, $NO_x$ concentration exceeded a standard in 92 links out of 220 links. The extended time in stop period and the stop-and-go driving cycle were identified as two important reasons for increased $NO_x$ emissions in observed cases. Heavy traffics showed higher $NO_x$ emissions than free flow. These results indicate that the real-world vehicle emissions might exceed the compliance level associate with traffic conditions. Another interesting observation of this research is that the on-road emission characteristics can be independent to the average speed of road links with higher spatial resolution. Variability in on-road emission might not be fully described by solely relying on an average speed, because variability in traffic conditions and road conditions can influence on real-world vehicle emissions.

발전소 회전기기 정밀진단을 위한 휴대용 진동분석기 개발 (Development of a Portable Vibration Analyzer for Precision Diagnosis of Plant's Rotating Equipment)

  • 노형호;유호선
    • 플랜트 저널
    • /
    • 제17권4호
    • /
    • pp.53-60
    • /
    • 2021
  • 본 연구에서는 국내 진동감시시스템 제작업체인 (주)나다와 발전소 회전기기 진동데이터 취득 및 분석에 효과적인 휴대용 진동분석기를 개발하고자 하였다. 개발된 휴대용 진동분석기의 하드웨어는 측정기기의 교정을 위한 측정 불확도를 통해 얻은 측정값을 시스템에서 보정함으로써 측정오차를 최소화하였고, 고속 데이터 처리로 높은 분해능을 가진 신호처리 장치로 구성되었다. 소프트웨어 구조는 다양한 진동 플롯을 구현하여 상세한 분석프로그램을 실행하며, 회전기기 운전 중 외란으로 발생하는 노이즈 측정 및 제거에 효과적인 알고리즘을 적용하였다. 개발품은 사용자의 이동 편의성 증대 및 고속 데이터 처리로 분해능을 높임으로써 성능향상은 물론, 국산화 개발에 따른 구입비용 절감에도 크게 기여하였다.