• Title/Summary/Keyword: platform switching

Search Result 83, Processing Time 0.025 seconds

Three-dimensional finite element analysis of platform switched implant

  • Moon, Se-Young;Lim, Young-Jun;Kim, Myung-Joo;Kwon, Ho-Beom
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.1
    • /
    • pp.31-37
    • /
    • 2017
  • PURPOSE. The purpose of this study was to analyze the influence of the platform switching concept on an implant system and peri-implant bone using three-dimensional finite element analysis. MATERIALS AND METHODS. Two three-dimensional finite element models for wide platform and platform switching were created. In the wide platform model, a wide platform abutment was connected to a wide platform implant. In the platform switching model, the wide platform abutment of the wide platform model was replaced by a regular platform abutment. A contact condition was set between the implant components. A vertical load of 300 N was applied to the crown. The maximum von Mises stress values and displacements of the two models were compared to analyze the biomechanical behavior of the models. RESULTS. In the two models, the stress was mainly concentrated at the bottom of the abutment and the top surface of the implant in both models. However, the von Mises stress values were much higher in the platform switching model in most of the components, except for the bone. The highest von Mises values and stress distribution pattern of the bone were similar in the two models. The components of the platform switching model showed greater displacement than those of the wide platform model. CONCLUSION. Due to the stress concentration generated in the implant and the prosthodontic components of the platform switched implant, the mechanical complications might occur when platform switching concept is used.

Evaluation of marginal bone loss around platform-switched implants by digital subtraction radiography (디지털 공제술을 이용한 platform switching 임플란트의 변연골 소실에 대한 연구)

  • Kim, Chi-Yoon;Kim, Sung-Sook;In, Hee-Sun;Kim, Yu-Lee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.31 no.1
    • /
    • pp.33-44
    • /
    • 2015
  • Purpose: This study is to evaluate the clinical significance of the platform switching concept by comparing the marginal bone loss around platform-matched and platform-switched implants. Materials and Methods: Date of implant placement, diameter, length, implant-abutment connection type and absence of splinting prosthesis were investigated on patients who performed treatment with implant placement at Wonkwang University Dental Hospital Implant Center. To measure the marginal bone loss around implants, periapical radiographs of patient were used when implant was placed and when visited the center most recently by using the program, Emago advanced v5.6. Results: As a result of observing on 150 implants of 82 patients for 6 - 63 months, platform-matched implants showed $1.16{\pm}0.54mm$, platform-switched implants showed $0.68{\pm}0.27mm$ of marginal bone loss. Conclusion: It was considered that there is the positive effect to reduce marginal bone loss around platform-switched implants.

Evaluation of platform switching and its clinical application (Platform switching(또는 Platform shifting) 개념 및 임상적용에 관한 고찰)

  • Yang, Byoung-Eun;Song, Sang-Hun;Kim, Seong-Gon
    • The Journal of the Korean dental association
    • /
    • v.45 no.9 s.460
    • /
    • pp.562-570
    • /
    • 2007
  • Many dentists and patients expect that implant function and esthetics will not change over time. However, even the most successful implant restorations with ideal position, vertical height, and occlusion can be aesthetically pleasing, but may hide a common problem. Many dentists noticed that there can be some circumferential bone loss around the neck of the implants. To circumvent this bone loss, a "platform switching" concept was introduced recently. The basic concept of platform switching is by moving the fixture-abutment interface further away from the crestal bone to minimize crestal bone loss. Since crestal bone loss is a multifactor problem, it is important to consider microgap formation and micromotion between the implant and abutment because platform switching does not solve the problem on its own. In this article, we reviewed studies concerning platform switching and discussed the clinical application and the problems that may occur with its use.

  • PDF

An Abstract Object-Oriented Platform Model for an ATM Switching System

  • Kim, Young-Man;Jung, Boo-Geum;Lee, Eun-Hyang;Lim, Dong-Sun
    • Proceedings of the IEEK Conference
    • /
    • 2000.07b
    • /
    • pp.723-726
    • /
    • 2000
  • In this paper, we present an abstract object-oriented plat-form model .suitable for the real-time distributed telecommunication system. The proposed platform is constructed upon the extended version of the real-time, distributed operating system, SROS(Scalable Real-time Operating System), that is developed at ETRI and successfully operated in the ATM switching system for several years. The object-oriented software development and maintenance methodology will resolve the current software crisis in the area of telecommunication and switching systems due to the everlasting maintenance about the huge amount of the existing software and the ever increasing needs for the better and new communication services. In general, an object-oriented software platform realizes the object-oriented methodology and possesses many good aspects like high productivity, better reusability, easy maintenance, et at. The platform is also designed to present the distributed multimedia service in addition to real-time event delivery. Recently, we have been implementing a couple of prototype bated on the proposed platform. Reflecting the evaluation results from these prototypes, the final platform specification will be determined.

  • PDF

APPLICATION OF FINITE ELEMENT ANALYSIS TO EVALUATE PLATFORM SWITCHING

  • Kim Yang-Soo;Kim Chang-Whe;Jang Kyung-Soo;Lim Young-Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.6
    • /
    • pp.727-735
    • /
    • 2005
  • Statement of problem. Platform switching in implant prosthesis has been used for esthetic and biological purpose. But there are few reports for this concept. Purpose. The purpose of this study is evaluation of platform switching in wide implant by three dimensional finite element analysis. Materials and Methods. The single implant and prosthesis was modeled in accordance with the geometric designs for Osstem implant system. Three-dimensional finite element models were developed for (1) a wide diameter 3i type titanium implant 5 mm in diameter, 13 mm in length with wide cemented abutment, titanium alloy abutment screw, and prosthesis (2) a wide diameter 3i type titanium implant 5 mm in diameter, 13 mm in length with regular cemented abutment, titanium alloy abutment screw and prosthesis(platform switching) was made for finite element analysis. The abutment screws were subjected to a tightening torque of 30 Ncm. The amount of preload was hypothesized to 650N, and round and flat type prostheses were loaded to 200 N. Four loading offset point (0, 2, 4, 6 mm from the center of the implants) were evaluated. Models were processed by the software programs HyperMesh and ANSA. The PAM-CRASH 2G simulation software was used for analysis of stress. The PAM-VIEW and HyperView were used for post processing. Results. The results from experiment were as follows; 1. von Mises stress value is increased in order of bone, abutment, implant and abutment screw. 2. von Mises stress of abutment screw is lower when platform switching. 3. von Mises stress of implant is lower when platform switching until loading offset 4 mm. 4. von Mises stress of abutment is similar between each other. 5. von Mises stress of bone is slightly higher when platform switching. Conclusion. The von Mises stress pattern of implant components is favor when platform switch ing but slightly higher in bone stress distribution than use of wide abutment. The research about stress distribution is essential for investigation of the cortical bone loss.

A Study on Factors Affecting Vender's Continuous Use Intention in O2O Delivery App Platform Service (O2O 배달 앱 플랫폼 서비스에서 공급 업체의 지속이용의도에 영향을 미치는 요인에 관한 연구)

  • Lee, Jae Kwang;Choi, Youngwoo;Lim, Eunju;Kim, Yoomin;Ahan, Saerom;Kim, Minjeong
    • Journal of Information Technology Services
    • /
    • v.20 no.2
    • /
    • pp.13-31
    • /
    • 2021
  • Recently, delivery app services based on the O2O platform are increasing rapidly. Accordingly, various studies on O2O service have been conducted. Most of the studies are on consumer behavior in O2O services, and few studies on platform vendors have been conducted. Therefore, this study empirically analyzed the factors affecting the vender's intention to continuous use in the O2O delivery app platform service. Based on prior researches, we set the quality characteristics and network characteristics of the O2O platform as independent variables. The quality characteristics of the O2O platform consisted of system quality, information quality, and service quality, and the O2O platform network characteristics consisted of network externality and platform reputation. Perceived value and switching cost were set as mediated variables, and vender's intention to continuous use was set as dependent variables. For empirical analysis, we conducted a survey targeting vendors of O2O delivery app platform service, and conducted frequency analysis, factor analysis, reliability analysis, and regression analysis. As a result of the analysis, the quality characteristics of the O2O platform, such as system quality, information quality, service quality, and O2O platform network characteristics, showed that network externality and platform reputation had a positive effect on perceived value. The perceived value was found to have a positive effect on the switching cost and the intention to continuous use, and the switching cost was found to mediate the perceived value and the intention to continuous use. This study can contribute to the establishment of platform operation strategy as an empirical analysis on the factors that influence the intention of O2O platform vendors to use the platform continuously.

Influence of platform switching on crestal bone resorption (치조정 골흡수에 대한 platform switching이 미치는 영향)

  • Kim, Do-Young;Kim, Tae-Il;Seol, Yang-Jo;Lee, Yong-Moo;Ku, Young;Rhyu, In-Chul;Chung, Chong-Pyoung;Han, Soo-Boo
    • Journal of Periodontal and Implant Science
    • /
    • v.38 no.2
    • /
    • pp.135-142
    • /
    • 2008
  • Purpose: Numerous studies have shown that crestal bone resorption around the implant was related to the location of the implant abutment junction(IAJ). Recently it was hypothesized that platform switching termed the inward horizontal repositioning of the IAJ might limit bone resorption around the implants. The purpose of this clinical study was to evaluate the effect of platform switching on crestal bone resorption. Materials and Methods: The crestal bone loss of 65 external hex implants in 26 patients were radiographically measured at crown placement and follow-up examinations. 23 standard implants(non-platform switching group, NP) were connected with the matching abutments and 42 wide implants(platform switching group, PS) were connected with the 1 mm smaller diameter abutments. Results: There was significant difference of crestal bone loss between NP group and PS group. For implants in the NP group, mean crestal bone loss was $1.18{\pm}0.68\;mm$ at crown placement and $1.42{\pm}0.41\;mm$ at follow-up. The meal bone loss in PS group was $0.47{\pm}0.52\;mm$ at crown placement and $0.60{\pm}0.65\;mm$ at follow-up. When the crestal bone changes according to placement depths of implants were compared, subcrestal position of IAJ had a significantly less bone loss in PS group, but it was not in NP group. Conclusion: Within the limits of the present study, it was concluded that platform switching technique might decrease crestal bone loss around the implants. Additionally, when the IAJ of implant was placed 1 mm deeper in the alveolar bone, the effect of platform switching on bone loss was enhanced.

An Analysis on Competition and Ecology of Mobile Platform : Based on the Continuous Usage Intention of Smart-Phone OS Platform (모바일 플랫폼 경쟁과 모바일 생태계에 관한 고찰 : 스마트폰 운영 플랫폼의 지속사용 의도를 중심으로)

  • Lee, Bo-Kyoung;Shim, Seon-Young
    • Journal of Information Technology Services
    • /
    • v.11 no.2
    • /
    • pp.19-47
    • /
    • 2012
  • Contemporary smartphone competition is generally described as the battle between Apple's proprietary platform and Google's open platform. However, this competition is not limited within smartphone adoption itself. User's pre-adoption of one mobile platform via smartphone can be connected to the post-adoption of the same mobile platform based on the other smart devices (e.g. smart pad). In this study, we investigate whether user's preference to a certain platform is persistent over mobile ecology, from the pre-adoption of one smart device to the post-adoption of following devices. For this investigation, we adopt the dual-model as the ground theory, where post-adoption of IT product is explained by both dedication and constraint factors. The empirical testing first evidences that dual model works well as our research model for identifying the reasons of post-adoption. Next, we group our data into two parts in order to compare the switching behavior of iPhone users and Android phone users. iPhone users show much lower switching rate to Android based smart pads, while Android phone users show higher churn rate to iPad (49.3% : 96.3%). Especially, satisfaction showed much stronger effect than switching cost on the continuing intention of existing platform, when the analysis is given to the iPhone user's group. From this result, we can conjecture the relatively stronger loyalty of iPhone users. More managerial implications on the mobile platform strategy are driven.

Service Characteristics Leading to "Winner-takes-all" Phenomenon in Platform Business (플랫폼 비즈니스에서의 승자독식 현상에 영향을 미치는 서비스 특성)

  • Jeon, Ikjin;Ahn, JaeHyeon;Kim, Dohoon
    • Korean Management Science Review
    • /
    • v.33 no.4
    • /
    • pp.33-49
    • /
    • 2016
  • The market of platform business is typically served by a few dominant players, presenting "winner-takes-all" phenomenon. This study aims to find service characteristics leading to the phenomenon. Six different service-characteristics were considered : Same-side network effect, cross-side network effects, entry barrier, multi-homing cost, switching cost, and heterogeneity of preference. To assess the degree of concentration of market share, HHI (Herfindahl-Hirschman Index) is calculated for top three major players. Based on the HHI value, 10 most eminent platform businesses are classified into three different segments and each segment is characterized with key factors. The results from this study provide some insight into the strategic management of platform business.

A Study on Optical Transport Platform on ATCA

  • Yang, Choong-Reol;Ko, Je-Soo
    • Journal of the Optical Society of Korea
    • /
    • v.11 no.4
    • /
    • pp.145-148
    • /
    • 2007
  • In this paper, we discuss a study on Advanced TCA(ATCA) based 40 Gbps level Optical transport platform having 120 Gbps(12, 10 Gbps modules) switching capacity as an OTP based large capacity multi service technology. The ATCA-based OTP(Optical Transport Platform) is composed of OTH(Optical Transport Hierarchy) 10 or 40 Gbps client signal interface module, OTH 10 Gbps transport module, high-rate OTH unit switch, system processor, and can be installed in ATCA platform.