• Title/Summary/Keyword: plaster method

Search Result 95, Processing Time 0.02 seconds

Numerical Simulationof Plaster Casting with Pressurized Vibration (진동을 부가한 저압의 석고주조 공정 해석)

  • Kim, Gi-Don;Yang, Dong-Yeol;Jeong, Jun-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.9
    • /
    • pp.101-109
    • /
    • 2001
  • The simulated die casting process in which the traditional plaster casting process is combined with rapid prototyping technology is being used to produce Al, Mg and Zn die casting prototypes. Because of lower mechanical properties induced by the large grain structure and incomplete filling, conventional plaster casting is not suitable for the simulated die casting process. A plaster casting process with pressurized vibration was developed for the simulated die casting process[5]. In this paper, numerical simulation for the filling stage of the process has been performed to show the effect of the pressurized vibration for complete filling. Treatment of boundary condition based on the finite element method has been proposed for imparted pressurized vibration in the plaster casting process.

  • PDF

A Literature study on the external therapy of contact dermatitis. (接觸性皮膚炎의 外治法에 關한 文獻的 考察)

  • Jeon, Jae-hong;Kim, Hyun-a;Kang, Yun-ho;Ho
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.11 no.1
    • /
    • pp.197-218
    • /
    • 1998
  • In this study, I invastigate about oriental medical drug, dosage form and directions in external therapy of contact dermatitis. and after study on relationship oriental medical drug, dosage form and directions with cause, symptom and differentiation of symptom and sign. The results are as follows; 1. Most frequently used oriental medical drug is until qing(淸) dynasty Eriocheir sinensis H. Milne-Edwards(蟹), Salix babylonica L.(柳葉), Natrii sulfas(芒硝), Allium macrostemon Bge.(해), Nelumbo nucifera Gaertn.(荷葉), nowadays in Korea and China Phellodendron amurense Rupr.(黃柏), Gypsum(石膏), Rheum palmatum L.(大黃), Baphicacanthus cusia Bremek(靑黛), Talcum(滑石). 2. In the frequency of dosage form, until qing(淸) dynasty powder 1case, liquor 49cases, liquer and solid mixture 58cases, nowadays Korea and China powder 16cases, liquor 96cases, liquer and solid mixture 59cases. 3. Most frequently used directions of dosage is thinly attaching method(薄貼法), attaching method(敷貼法), furnigating and cleansing method(熏洗法), cleansing method(洗傷法), wet dressing method(濕敷法), spreading powder method(撲粉法), plaster method(途차法), rubbing skin method(摩擦法) 4. In the external therapy of contact dermatitis, oriental medical drug's usage is based on stage of contact dermatitis In acute stage, most frequently used drug is heat and damp remove drug(淸熱燥濕藥), nature of drug(藥性) is bitter taste and cold charactor(苦寒), In chronic stage, most frequently used drug is nourishing the blood drug(養血藥), promoting blood circulation drug(活血藥). 5. The dosage form of drug is based on symptom. In acute stage, when papules and vesicles, or erosion and exudation is the main symptom of skin, liquor or powder is used, when erosion and crust is the main symptom of skin, plaster is used. In chronic stage, plaster is used. 6. In the directions of dosage is based on dosage form of drug and symptom. In acute stage, when papules and vesicles is the main symptom of skin, fumigating and cleansing method, cleansing method, plaster method is used, when erosion, vesicles and exudation the main symptom of skill, cleansing method, wet dressing method, spreading powder method, attaching method, spreading powder method is used, when crust is the main symptom of skin, plaster method is used. In chronic stage, plaster method, rubbing skin method is used.

  • PDF

Fire Resistance of High Strength Concrete followed by Thickness of Fireproof Plaster Board and Change of Adhesive Method (방화석고보드의 두께 및 접착방식 변화에 따른 고강도 콘크리트의 내화특성)

  • Jang, Ki-Hyun;Kim, Won-Ki;Jin, Hu-Lin;Lee, Jin-Woo;Yang, Seong-Hwan;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2008.05a
    • /
    • pp.67-71
    • /
    • 2008
  • The study analyzed on fire resistance of high strength concrete followed by thickness of fireproof plaster board and change of adhesive method. In spalling characteristics after fire resistance test, all four-side covering concretes were left out of testing screens. Thus, serious spalling was happened by exposing their internal reinforcing rods. in partial testing screens, spalling was happened till the internal concrete of main reinforcing rod. Only, temperature history didn't have special differences among changes of adhesive method. However, thickness of fireproof plaster board is very important. Namely, mock member reinforcing 25mm general adhesive + Bending was 583℃ in the highest temperature of surface part and 479℃ in the highest temperature of the main reinforcing rod, which was relatively good temperature history.

  • PDF

Combination Effects of Capsicum Plaster at the Korean Hand Acupuncture Points K-D2 with Prophylactic Antiemetic on Postoperative Nausea and Vomiting after Gynecologic Laparoscopy (고추파스를 이용한 수지요법 침점(K-D2) 자극과 예방적 항구토제의 병용요법이 부인과 복강경 수술 후 오심과 구토에 미치는 효과)

  • Jung, Hyun Jung;Park, Sang Youn
    • Journal of Korean Academy of Nursing
    • /
    • v.43 no.2
    • /
    • pp.215-224
    • /
    • 2013
  • Purpose: This study was done to evaluate the combination effects of capsicum plaster at the Korean hand acupuncture points K-D2 with prophylactic antiemetic on Postoperative Nausea and Vomiting (PONV). Methods: An experimental research design (a randomized, a double-blinded, and a placebo-control procedure) was used. The participants were female patients undergoing gynecologic laparoscopy; the control group (n=34) received intravenous prophylactic ramosetron 0.3mg, while the experimental group (n=34) had Korean Hand Therapy additionally. In the experimental group, capsicum plaster was applied at K-D2 of both 2nd and 4th fingers by means of Korean Hand Therapy for a period of 30 minutes before the induction of anesthesia and removed 8 hours after the laparoscopy. Results: The occurrence of nausea, nausea intensity and need for rescue with antiemetic in the experimental group was significantly less than in the control group 2 hours after surgery. Conclusion: Results of the study show capsicum plaster at K-D2 is an effective method for reducing PONV in spite of the low occurrence of PONV because of the prophylactic antiemetic medication.

Accuracy and precision of polyurethane dental arch models fabricated using a three-dimensional subtractive rapid prototyping method with an intraoral scanning technique

  • Kim, Jae-Hong;Kim, Ki-Baek;Kim, Woong-Chul;Kim, Ji-Hwan;Kim, Hae-Young
    • The korean journal of orthodontics
    • /
    • v.44 no.2
    • /
    • pp.69-76
    • /
    • 2014
  • Objective: This study aimed to evaluate the accuracy and precision of polyurethane (PUT) dental arch models fabricated using a three-dimensional (3D) subtractive rapid prototyping (RP) method with an intraoral scanning technique by comparing linear measurements obtained from PUT models and conventional plaster models. Methods: Ten plaster models were duplicated using a selected standard master model and conventional impression, and 10 PUT models were duplicated using the 3D subtractive RP technique with an oral scanner. Six linear measurements were evaluated in terms of x, y, and z-axes using a non-contact white light scanner. Accuracy was assessed using mean differences between two measurements, and precision was examined using four quantitative methods and the Bland-Altman graphical method. Repeatability was evaluated in terms of intra-examiner variability, and reproducibility was assessed in terms of interexaminer and inter-method variability. Results: The mean difference between plaster models and PUT models ranged from 0.07 mm to 0.33 mm. Relative measurement errors ranged from 2.2% to 7.6% and intraclass correlation coefficients ranged from 0.93 to 0.96, when comparing plaster models and PUT models. The Bland-Altman plot showed good agreement. Conclusions: The accuracy and precision of PUT dental models for evaluating the performance of oral scanner and subtractive RP technology was acceptable. Because of the recent improvements in block material and computerized numeric control milling machines, the subtractive RP method may be a good choice for dental arch models.

Fire Resistance of Repaired High Strength Concrete Column Damaged by Fire (화재 피해를 입은 고강도 콘크리트 기둥의 보수공법 변화에 따른 내화특성)

  • Park, Chun-Jin;Back, Dae-Hyun;In, Gi-Ho;Yeo, In-Hwan;Min, Byung-Yeol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.11a
    • /
    • pp.113-116
    • /
    • 2009
  • This study analyzed fire-resistant characteristics according to changes in repair methods of PFH mixed high-strength concrete roof structures having undergone fire damage. The results of the study are as follows. First, as a repulsive characteristics of structures, the remaining repulsion was shown to increase following fire-resistance tests according to increases in depth of coverings. The results of the relationship between depth of coverings and remaining repulsion rates following fire-proofing tests showed a high correlation. At a covering depth of 67.3mm, remaining repulsion rate was estimated to be 100%. For fire-resistant characteristics following repairs of structure, as for spalling, severe separation was shown in the case of general plaster while general plaster + Metal Lath showed overall superior spalling prevention. For internal structure temperatures, general plaster showed max temperatures of 705℃, average temperatures of 636℃ while general plaster + metal lath showed max temperature of 660℃ and average temperature of 520℃, demonstrating lower temperature distributions than use of only general plaster. In conclusion, after removing the covering of structures damaged due to high temperatures of fires within high-strength concrete installations, the use of fire-resistant mortars and applying metal laths on surfaces of general plaster will provide superior fire-resistance performance in the occurrence of a 2nd fire.

  • PDF

Evaluation of accuracy of 3-dimensional printed dental models in reproducing intermaxillary relational measurements: Based on inter-operator differences

  • Choi, Won-joon;Lee, Su-jung;Moon, Cheol-Hyun
    • The korean journal of orthodontics
    • /
    • v.52 no.1
    • /
    • pp.20-28
    • /
    • 2022
  • Objective: Although, digital models have recently been used in orthodontic clinics, physical models are still needed for a multitude of reasons. The purpose of this study was to assess whether the printed models can replace the plaster models by evaluating their accuracy in reproducing intermaxillary relationships and by appraising the clinicians' ability to measure the printed models. Methods: Twenty sets of patients' plaster models with well-established occlusal relationships were selected. Models were scanned using an intraoral scanner (Trios 3, 3Shape Dental System) by a single operator. Printed models were made with ZMD-1000B light-curing resin using the stereolithography method 3-dimensional printer. Validity, reliability, and reproducibility were evaluated using measurements obtained by three operators. Results: In evaluation of validity, all items showed no significant differences between measurements taken from plaster and printed models. In evaluation for reliability, significant differences were found in the distance between the gingival zeniths of #23-#33 (DZL_3) for the plaster models and at #17-#43 (DZCM_1) for the printed models. In evaluation for reproducibility, the plaster models showed significant differences between operators at midline, and printed models showed significant differences at 7 measurements including #17-#47 (DZR_7). Conclusions: The validity and reliability of intermaxillary relationships as determined by the printed model were clinically acceptable, but the evaluation of reproducibility revealed significant inter-operator differences. To use printed models as substitutes for plaster models, additional studies on their accuracies in measuring intermaxillary relationship are required.

New Measuring Method of Breast Volume Using Polyethylene Bag and Plaster Molding (투명 폴리백과 반창고를 이용한 간편한 유방 부피 측정법의 소개)

  • Lee, Seung Jong;Lee, Hye Kyung;Tark, Kwan Chul;Shin, Keuk Shun
    • Archives of Plastic Surgery
    • /
    • v.33 no.5
    • /
    • pp.676-679
    • /
    • 2006
  • Purpose: Breast volume is one of the crucial measurements in preoperative planning and postoperative evaluation of the results in mammoplasty. There are several methods suggested by different authors, but there is still no commonly accepted standard methods for measuring breast volume. To help the surgeons to base their estimation on an objective evaluation, we developed a simple method using Polyethylene bag and plaster molding. Methods: After Polyethylene bags were put in suitable size on both breasts of the patient in upright position, silk plaster was molded on the surface evenly. Then molds can be obtained after marking boundaries of breasts with a pen. Breast volume measurement can be done by filling water in the molds and measuring it. Moreover, postoperative design for natural skin brassier was possible using the molds. Results: This method was applied to 2 patients for reduction mammoplasty and the breast volume measurement was simple, hygienic and accurate, done within 10 minutes. Conclusion: This method using Polyethylene bag and plaster molding has several advantages. 1. It is comparatively accurate regardless of the size and shape of patient's breasts in upright position. 2. Measurement time is short and inconvenience and shame of patients can be reduced by making molds after putting on Polyethylene bags. 3. It is relatively economical and uses easily available hygienic materials. 4. The postoperative shape and volume of breasts can be predicted by using molds preoperatively.

Experimental and numerical investigation of walls strengthened with fiber plaster

  • Basaran, Hakan;Demir, Ali;Bagci, Muhiddin;Ergun, Sefa
    • Structural Engineering and Mechanics
    • /
    • v.56 no.2
    • /
    • pp.189-200
    • /
    • 2015
  • The topic of this study is to investigate behaviors of masonry walls strengthened with reinforced fiber plaster under diagonal tensile loads. Full blend brick $100{\times}50{\times}30mm$ in dimensions were used to make masonry walls with dimensions of $400{\times}400{\times}100mm$. Three different samples were manufactured by plastering masonry walls with traditional style, with 3% polypropylene or with 5% steel fiber. All the samples were tested using ASTM 1391-81 standards. The propagation of damage on samples caused by diagonal tensile load was observed and load-displacement graphs were plotted for each sample. A finite element software (ABAQUS) was used to obtain numerical values for all samples and crack patterns and load-displacement responses were obtained. Experimental and numerical results were compared.

Accuracy of five implant impression technique: effect of splinting materials and methods

  • Lee, Sang-Jik;Cho, Sung-Bum
    • The Journal of Advanced Prosthodontics
    • /
    • v.3 no.4
    • /
    • pp.177-185
    • /
    • 2011
  • PURPOSE. The aim of this study was to evaluate the effect of dimensional stability of splinting material on the accuracy of master casts. MATERIALS AND METHODS. A stainless steel metal model with 6 implants embedded was used as a master model. Implant level impressions were made after square impression copings were splinted using 5 different techniques as follows. (1) Splinted with autopolymerizing resin and sectioned, reconnected to compensate polymerization shrinkage before the impression procedure. (2) Splinted with autopolymerizing resin just before impression procedure. (3) Primary impression made with impression plaster and secondary impression were made over with polyether impression material. (4) Splinted with impression plaster. (5) Splinted with VPS bite registration material. From master model, 5 impressions and 5 experimental casts, total 25 casts were made for each of 5 splinting methods. The distortion values of each splinting methods were measured using coordinate measuring machine, capable of recordings in the x-, y-, z- axes. A one-way analysis of variance (ANOVA) at a confidence level of 95% was used to evaluate the data and Tukey's studentized range test was used to determine significant differences between the groups. RESULTS. Group 1 showed best accuracy followed by Group 3 & 4. Group 2 and 5 showed relatively larger distortion value than other groups. No significant difference was found between group 3, 4, 5 in x-axis, group 2, 3, 4 in y-axis and group 1, 3, 4, 5 in z-axis (P<.0001). CONCLUSION. Both Splinting impression copings with autopolymerizing resin following compensation of polymerization shrinkage and splinting method with impression plaster can enhance the accuracy of master cast and impression plaster can be used simple and effective splinting material for implant impression procedure.