DOI QR코드

DOI QR Code

Accuracy of five implant impression technique: effect of splinting materials and methods

  • Received : 2011.03.01
  • Accepted : 2011.11.21
  • Published : 2011.12.30

Abstract

PURPOSE. The aim of this study was to evaluate the effect of dimensional stability of splinting material on the accuracy of master casts. MATERIALS AND METHODS. A stainless steel metal model with 6 implants embedded was used as a master model. Implant level impressions were made after square impression copings were splinted using 5 different techniques as follows. (1) Splinted with autopolymerizing resin and sectioned, reconnected to compensate polymerization shrinkage before the impression procedure. (2) Splinted with autopolymerizing resin just before impression procedure. (3) Primary impression made with impression plaster and secondary impression were made over with polyether impression material. (4) Splinted with impression plaster. (5) Splinted with VPS bite registration material. From master model, 5 impressions and 5 experimental casts, total 25 casts were made for each of 5 splinting methods. The distortion values of each splinting methods were measured using coordinate measuring machine, capable of recordings in the x-, y-, z- axes. A one-way analysis of variance (ANOVA) at a confidence level of 95% was used to evaluate the data and Tukey's studentized range test was used to determine significant differences between the groups. RESULTS. Group 1 showed best accuracy followed by Group 3 & 4. Group 2 and 5 showed relatively larger distortion value than other groups. No significant difference was found between group 3, 4, 5 in x-axis, group 2, 3, 4 in y-axis and group 1, 3, 4, 5 in z-axis (P<.0001). CONCLUSION. Both Splinting impression copings with autopolymerizing resin following compensation of polymerization shrinkage and splinting method with impression plaster can enhance the accuracy of master cast and impression plaster can be used simple and effective splinting material for implant impression procedure.

Keywords

References

  1. Adell R, Lekholm U, Rockler B, Branemark PI. A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. Int J Oral Surg 1981;10:387-416. https://doi.org/10.1016/S0300-9785(81)80077-4
  2. Zarb GA, Schmitt A. The longitudinal clinical effectiveness of osseointegrated dental implants in anterior partially edentulous patients. Int J Prosthodont 1993;6:180-8.
  3. Goll GE. Production of accurately fitting full-arch implant frameworks: Part I-Clinical procedures. J Prosthet Dent 1991;66:377-84. https://doi.org/10.1016/0022-3913(91)90266-Y
  4. Rangert B, Jemt T, Jorneus L. Forces and moments on Branemark implants. Int J Oral Maxillofac Implants 1989;4:241-7.
  5. Zarb GA, Schmitt A. The longitudinal clinical effectiveness of osseointegrated dental implants: the Toronto Study. Part II: The prosthetic results. J Prosthet Dent 1990;64:53-61. https://doi.org/10.1016/0022-3913(90)90153-4
  6. Jemt T. Failures and complications in 391 consecutively inserted fixed prostheses supported by Branemark implants in edentulous jaws: a study of treatment from the time of prosthesis placement to the first annual checkup. Int J Oral Maxillofac Implants 1991;6:270-6.
  7. Jemt T. In vivo measurements of precision of fit involving implant-supported prostheses in the edentulous jaw. Int J Oral Maxillofac Implants 1996;11:151-8.
  8. Kallus T, Bessing C. Loose gold screws frequently occur in fullarch fixed prostheses supported by osseointegrated implants after 5 years. Int J Oral Maxillofac Implants 1994;9:169-78.
  9. Johansson G, Palmqvist S. Complications, supplementary treatment, and maintenance in edentulous arches with implant-supported fixed prostheses. Int J Prosthodont 1990;3:89-92.
  10. Tan KB, Rubenstein JE, Nicholls JI, Yuodelis RA. Three-dimensional analysis of the casting accuracy of one-piece, osseointegrated implant-retained prostheses. Int J Prosthodont 1993;6:346-63.
  11. Stumpel LJ 3rd, Quon SJ. Adhesive abutment cylinder luting. J Prosthet Dent 1993;69:398-400. https://doi.org/10.1016/0022-3913(93)90188-T
  12. Humphries RM, Yaman P, Bloem TJ. The accuracy of implant master casts constructed from transfer impressions. Int J Oral Maxillofac Implants 1990;5:331-6.
  13. Tautin FS. Impression making for osseointegrated dentures. J Prosthet Dent 1985;54:250-1. https://doi.org/10.1016/0022-3913(85)90299-9
  14. Henry PJ. An alternative method for the production of accurate casts and occlusal records in osseointegrated implant rehabilitation. J Prosthet Dent 1987;58:694-7. https://doi.org/10.1016/0022-3913(87)90421-5
  15. Carr AB, Stewart RB. Full-arch implant framework casting accuracy: preliminary in vitro observation for in vivo testing. J Prosthodont 1993;2:2-8. https://doi.org/10.1111/j.1532-849X.1993.tb00373.x
  16. Assif D, Fenton A, Zarb G, Schmitt A. Comparative accuracy of implant impression procedures. Int J Periodontics Restorative Dent 1992;12:112-21.
  17. Barrett MG, de Rijk WG, Burgess JO. The accuracy of six impression techniques for osseointegrated implants. J Prosthodont 1993;2:75-82. https://doi.org/10.1111/j.1532-849X.1993.tb00387.x
  18. Carr AB. Comparison of impression techniques for a five-implant mandibular model. Int J Oral Maxillofac Implants 1991;6:448-55.
  19. Gordon GE, Johnson GH, Drennon DG. The effect of tray selection on the accuracy of elastomeric impression materials. J Prosthet Dent 1990;63:12-5. https://doi.org/10.1016/0022-3913(90)90257-D
  20. Rueda LJ, Sy-Muñoz JT, Naylor WP, Goodacre CJ, Swartz ML. The effect of using custom or stock trays on the accuracy of gypsum casts. Int J Prosthodont 1996;9:367-73.
  21. Burns J, Palmer R, Howe L, Wilson R. Accuracy of open tray implant impressions: an in vitro comparison of stock versus custom trays. J Prosthet Dent 2003;89:250-5. https://doi.org/10.1067/mpr.2003.38
  22. Branemark PI, Zarb GA, Albrektsson T. Tissue-integrated prostheses. Osseointegration in clinical dentistry. Chicago: Quintessence; 1985. P. 11-2, 253-7.
  23. Hsu CC, Millstein PL, Stein RS. A comparative analysis of the accuracy of implant transfer techniques. J Prosthet Dent 1993;69:588-93. https://doi.org/10.1016/0022-3913(93)90287-X
  24. Phillips KM, Nicholls JI, Ma T, Rubenstein J. The accuracy of three implant impression techniques: A three-dimensional analysis. Int J Oral Maxillofac Implants 1994;9:533-40.
  25. Herbst D, Nel JC, Driessen CH, Becker PJ. Evaluation of impression accuracy for osseointegrated implant supported superstructures. J Prosthet Dent 2000;83:555-61. https://doi.org/10.1016/S0022-3913(00)70014-X
  26. Spector MR, Donovan TE, Nicholls JI. An evaluation of impression techniques for osseointegrated implants. J Prosthet Dent 1990;63:444-7. https://doi.org/10.1016/0022-3913(90)90235-5
  27. Inturregui JA, Aquilino SA, Ryther JS, Lund PS. Evaluation of three impression techniques for osseointegrated oral implants. J Prosthet Dent 1993;69:503-9. https://doi.org/10.1016/0022-3913(93)90160-P
  28. Burawi G, Houston F, Byrne D, Claffey N. A comparison of the dimensional accuracy of the splinted and unsplinted impression techniques for the Bone-Lock implant system. J Prosthet Dent 1997;77:68-75. https://doi.org/10.1016/S0022-3913(97)70209-9
  29. Assif D, Marshak B, Schmidt A. Accuracy of implant impression techniques. Int J Oral Maxillofac Implants 1996;11:216-22.
  30. Naconecy MM, Teixeira ER, Shinkai RS, Frasca LC, Cervieri A. Evaluation of the accuracy of 3 transfer techniques for implant- supported prostheses with multiple abutments. Int J Oral Maxillofac Implants 2004;19:192-8.
  31. Vigolo P, Majzoub Z, Cordioli G. Evaluation of the accuracy of three techniques used for multiple implant abutment impressions. J Prosthet Dent 2003;89:186-92. https://doi.org/10.1067/mpr.2003.15
  32. Cabral LM, Guedes CG. Comparative analysis of 4 impression techniques for implants. Implant Dent 2007;16:187-94. https://doi.org/10.1097/ID.0b013e3180587b3f
  33. Rhyu SM, Cho IH, Lim HS, Lim JH, A comparative study on the accuracy of master casts by implant impression techniques. J Korean Acad Prosthodont 2002;40;18-29
  34. Branemark PI. Osseointegration and its experimental background. J Prosthet Dent 1983;50:399-410. https://doi.org/10.1016/S0022-3913(83)80101-2
  35. Millington ND, Leung T. Inaccurate fit of implant superstructures. Part 1: Stresses generated on the superstructure relative to the size of fit discrepancy. Int J Prosthodont 1995;8:511-6.
  36. Jemt T, Book K. Prosthesis misfit and marginal bone loss in edentulous implant patients. Int J Oral Maxillofac Implants 1996;11:620-5.
  37. Jemt T, Lie A. Accuracy of implant-supported prostheses in the edentulous jaw: analysis of precision of fit between cast goldalloy frameworks and master casts by means of a three-dimensional photogrammetric technique. Clin Oral Implants Res 1995;6:172-80. https://doi.org/10.1034/j.1600-0501.1995.060306.x
  38. Mojon P, Oberholzer JP, Meyer JM, Belser UC. Polymerization shrinkage of index and pattern acrylic resins. J Prosthet Dent 1990;64:684-8. https://doi.org/10.1016/0022-3913(90)90296-O
  39. ANSI-ADA Specification No.25 Dental gypsum products. Chicago: American dental association council on dental materials and equipment. 2000.
  40. Dumbrigue HB, Gurun DC, Javid NS. Prefabricated acrylic resin bars for splinting implant transfer copings. J Prosthet Dent 2000;84:108-10. https://doi.org/10.1067/mpr.2000.107914
  41. Assif D, Nissan J, Varsano I, Singer A. Accuracy of implant impression splinted techniques: effect of splinting material. Int J Oral Maxillofac Implants 1999;14:885-8.
  42. Nissan J, Barnea E, Krauze E, Assif D. Impression technique for partially edentulous patients. J Prosthet Dent 2002;88:103-4. https://doi.org/10.1067/mpr.2002.127640
  43. Eid N. An implant impression technique using a plaster splinting index combined with a silicone impression. J Prosthet Dent 2004;92:575-7. https://doi.org/10.1016/j.prosdent.2004.09.013

Cited by

  1. Accuracy Comparison of Implant Impression Techniques: A Systematic Review vol.17, pp.15230899, 2015, https://doi.org/10.1111/cid.12310
  2. Collaboration Patterns and Processes Between Dentists and Dental Laboratories When Planning and Fabricating Implant-Supported Restorations vol.26, pp.3, 2017, https://doi.org/10.1097/ID.0000000000000581
  3. Accuracy of Implant Casts Generated with Conventional and Digital Impressions—An In Vitro Study vol.15, pp.8, 2018, https://doi.org/10.3390/ijerph15081599
  4. Cast accuracy obtained from different impression techniques at different implant angulations (in vitro study) vol.4, pp.None, 2011, https://doi.org/10.1186/s40729-018-0118-6
  5. Comparison of the accuracy of open-tray and snap-on impression techniques of implants with different angulations vol.16, pp.6, 2011, https://doi.org/10.4103/1735-3327.270785
  6. Full-mouth rehabilitation of screw-retained maxillary and mandibular hybrid denture vol.11, pp.1, 2011, https://doi.org/10.4103/njms.njms_22_19
  7. Accuracy of complete-arch implant impression made with occlusal registration material vol.123, pp.1, 2011, https://doi.org/10.1016/j.prosdent.2018.12.011
  8. To evaluate and compare the accuracy of definitive casts using various splinting methods on implant level impressions in All-on-Four treatment: An in vitro study vol.20, pp.2, 2011, https://doi.org/10.4103/jips.jips_210_19
  9. Comparison of the accuracy of different impression procedures in case of multiple and angulated implants : Accuracy of impressions in multiple and angulated implants vol.16, pp.None, 2020, https://doi.org/10.1186/s13005-020-00225-3
  10. Comparison of the Accuracy of Fixture-Level Implant Impression Making with Different Splinting Techniques vol.2021, pp.None, 2011, https://doi.org/10.1155/2021/2959055