• Title/Summary/Keyword: plasma stability

Search Result 408, Processing Time 0.028 seconds

Polymer (Polydimethylsiloxane (pdms)) Microchip Plasma with Electrothermal Vaporization for the Determination of Metal Ions in Aqueous Solution

  • Ryu, Won-Kyung;Kim, Dong-Hoon;Lim, H.B.;Houk, R.S.
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.4
    • /
    • pp.553-556
    • /
    • 2007
  • We previously reported a 27.12 MHz inductively coupled plasma source at atmospheric pressure for atomic emission spectrometry based on polymer microchip plasma technology. For the PDMS polymer microchip plasma, molecular emission was observed, but no metallic detection was done. In this experiment, a lab-made electrothermal vaporizer (ETV) with tantalum coil was connected to the microchip plasma for aqueous sample introduction to detect metal ions. The electrode geometry of this microchip plasma was redesigned for better stability and easy monitoring of emission. The plasma was operated at an rf power of 30-70 W using argon gas at 300 mL/min. Gas kinetic temperatures between 800-3200 K were obtained by measuring OH emission band. Limits of detection of about 20 ng/mL, 96.1 ng/mL, and 1.01 μ g/mL were obtained for alkali metals, Zn, and Pb, respectively, when 10 μ L samples in 0.1% nitric acid were injected into the ETV.

Development of Plasma Confinement by Applying Multi-Polar Magnetic Fields in an Internal Inductively Coupled Plasma System (선형 유도결합 플라즈마 시스템에서 자장에 의한 플라즈마의 Confinement 효과에 관한 연구)

  • Lim, Jong-Hyeuk;Kim, Kyong-Nam;Yeom, Geun-Young
    • Journal of the Korean institute of surface engineering
    • /
    • v.39 no.3
    • /
    • pp.142-146
    • /
    • 2006
  • A novel internal-type linear inductive antenna, which we refer to as a double comb-type antenna, was developed for a large-area plasma source with substrate size of $880\;mm{\times}660\;mm$ ($4^{th}$ generation glass size). In this study, effect of plasma confinement by applying multi-polar magnetic field was investigated. High density plasmas of the order of $3.18{\times}10^{11}\;cm^{-3}$ could be obtained with a pressure of 15 mTorr Ar at an inductive power of 5000 W with good plasma stability. This plasma density is higher than that obtained for the conventional double comb-type antenna, possibly due to the plasma confinement, low rf voltage, resulting in high power transfer efficiency. Also, due to the remarkable reduction in the antenna rf voltage and length, a plasma uniformity of less than 3% could be obtained within a substrate area of $880\;mm{\times}660\;mm$ as rf power increased.

Pervaporation of Organic Solvents using Plasma Polymerized Thin Film (플라즈마 중합박막을 이용한 유기용매의 투과증발)

  • Kim, Sung-O;Park, Bok-Kee;Kim, Du-Seok;Park, Jin-Kyu;Ryu, Seong-Ryal;Lee, Jin;Ra, Dong-Kyun;Lee, Deok-Chul
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1702-1703
    • /
    • 1999
  • We have prepared the plasma-polymerized membrane for pervaporation of organic-liquid mixtures by the plasma polymerization technique. Plasma polymerization techniques were utilized in the development of hydrophilic composite membranes having high hydrogen ion permeability and excellent dimensional stability. To develop an organic liquid permselective membrane. suppressing membrane swelling as well as enhancing the solubility difference is important, the objectives of the present study are to design a suitable membrane for an organic-mixture system by the control of the plasma-polymer solubility.

  • PDF

Monitoring of Laser Material Processing and Developments of Tensile Strength Estimation Model Using photodiodes (광센서를 이용한 레이저 가공공정의 모니터링과 인장강도 예측모델 개발)

  • Park, Young-Whan;Rhee, Se-Hun
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.17 no.1
    • /
    • pp.98-105
    • /
    • 2008
  • In this paper, the system for monitoring process of aluminum laser welding was developed using the light signal emitted from the plasma which comes from interaction between material and laser. Photodiode for monitoring system was selected based on the spectrum analysis of light from plasma and keyhole. Behavior of plasma and keyhole was analyzed through the sensor signals. Value of sensor signal represented the light intensity and fluctuation of signal indicated the stability of plasma and keyhole. For the relation between welding condition and sensor signals, the input power and weld geometry greatly effected on the average of each sensor signals. Using the feature values of signals, estimation model for tensile strength of weld was formulated with neural network algorithm. Performance of this model was verified through coefficient of determination and average error rate.

An Experimental Analysis on the Thermal Plasma Characteristics to the Geometry in Non-Transferred Torch (비이송식 플라즈마 토치 구조에 따른 열 플라즈마 특성 시험)

  • Jeong, An-Mok;Jun, Euy-Sik
    • Journal of the Semiconductor & Display Technology
    • /
    • v.8 no.4
    • /
    • pp.89-94
    • /
    • 2009
  • The influence on a stability of thermal plasma has been investigated in an electrode structure of non-transferred plasma torch. The variations of dynamic characteristic of the arc voltage was analyzed and compared in terms of voltage character and nozzle types for both the step-shaped nozzles and magnetic-approved cylindrical nozzle. From the experimental results, an electrode gap, flow rate of arc gas, and currents are considered as major operational parameters. As conclusion, it was assured that a torch with step-shaped nozzles of magnetic-approved type produce the stable plasma jet.

  • PDF

A Study on Medium Voltage Power Supply with Enhanced Ignition Characteristics for Plasma Torch

  • Jung, Kyung-Sub;Suh, Yong-Sug
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.242-243
    • /
    • 2010
  • This paper investigates a power supply of medium voltage with enhanced ignition characteristics for plasma torch. Series resonant half-bridge topology is presented to be a suitable ignition circuitry. The ignition circuitry is integrated into the main power conversion system of a multi-phase staggered three-level dc-dc converter with a diode front-end rectifier. The plasma torch rated for 3MW, 2kA and having the physical size of 1m long is selected to be a high enthalpy source in waste disposal system. The steady-state and transient operations of plasma torch are simulated. The parameters of Cassie-Mary arc model are calculated based on 3D magneto-hydrodynamic simulations. Circuit simulation waveform shows that the ripple of arc current can be maintained within ${\pm}10%$ of its rated value under the existence of load disturbance. This power conversion configuration provides high enough ignition voltage around 5KA during ignition phase and high arc stability under the existence of arc disturbance noise resulting in a high-performance plasma torch system.

  • PDF

CHARACTERIXATION OF PLASMA ION IMPLANTED SURFACES USING TIME-OF-FLIGHT SECONDARY ION MASS SPECTROMATRY

  • Lee, Yeon-Hee;Han, Seung-Hee;Lee, Jung-Hye;Yoon, Jung-Hyeon
    • Journal of the Korean institute of surface engineering
    • /
    • v.29 no.6
    • /
    • pp.880-883
    • /
    • 1996
  • Plasma Source Ion Implantation (PSII) technique was used for the hydrophilization or hydrophobization of polymer surfaces. Polymers were modified with different plasma gases such as oxygen, nitrogen, argon, and tetrafluoromethane, and for varying lengths of treatment time. Plasma ion treatment of oxygen, nitrogen, argon and their mixtures increased significantly the hydrophilic properties of polymer surfaces. More hydrophobic surfaces of polymers were formed after the treatment with tetrafluoromethane. A study of plasma source ion implanted polymers was performed using contact angle measurements and Time-of-Flight Secondary Ion Mass Spectrometry (TOF-SIMS). The TOF-SIMS spectra and depth profile were used to obtain the information about the treated surfaces of polymers. The permanence of this technique could be evaluated with respect to ageing time. The surfaces treated with PSII gave better stability than other surface modification methods.

  • PDF

Drug-Release Behavior of Polymeric Prodrugs of Ibuprofen with PEG and Its Derivatives as Polymeric Carriers

  • Lee, Chao-Woo
    • Macromolecular Research
    • /
    • v.12 no.1
    • /
    • pp.71-77
    • /
    • 2004
  • We have synthesized various types of poly(ethylene glycol) (PEG)-ibuprofen conjugates by nucleophilic substitution of bromo-terminated PEG with ibuprofen-Cs salt. The conversion of the terminal hydroxyl groups to bromo-termini was quantitative, as was the drug conjugation process, which suggests that the present synthetic method is very useful for the preparation of PEG-based prodrugs from pharmaceuticals having carboxyl functionalities. The drug-release behavior of the prodrugs was examined in both phosphate buffer (PBS, pH 7.4) and rat plasma. From the drug-release behavior in PBS, we determined that each prodrug has high storage stability. The drug-release rate was observed to be much faster in rat plasma than in buffer solution as a result of the acceleration effect provided by enzymes present in the plasma. The drug-release rate in rat plasma depends on the degree of molecular aggregation of the prodrugs, which can be changed effectively by the nature of their spacer groups or by the use of Pluronic as the polymer carrier.

Step Response of RF Plasma in Carbon Tetrafluoride($CF_4$)

  • So, Soon-Youl;Akinori Oda;Hirotake Sugawara;Yosuke Sakai
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.930-933
    • /
    • 2000
  • To understand the behavior of electron, ions and radicals on radio-frequency non-equilibrium plasma, it is necessary to know the basic information about its fundamental properties and reactions. Especially, the transient response of radio-frequency plasma has an important means of controlling selective etch rates and investigating the stability of a plasma chemical process. In this paper, we present the results of periodic steady-state behavior and transient behavior carbon Tetrafluoride(CF$_4$) discharge at 0.2 Torr in a 2 cm gap parallel-plate. After the number densities of charged particles became steady-state, the applied voltage was increased or decreased in an instant and the transient behavior of charged particles and radicals was investigated from one steady-state to the next steady state.

  • PDF

Comparative Studies on Morphology of Low Temperature Ar-Plasma-treated Polymer Surfaces (알곤저온플라즈마처리된 고분자표면의 모폴로지에 대한 비교연구)

  • Seo Eun-Deock
    • Textile Coloration and Finishing
    • /
    • v.16 no.5
    • /
    • pp.35-41
    • /
    • 2004
  • Poly(ethylene terephthalate), polyimide(Kapton), and polypropylene surfaces were modified with argon low temperature plasma by RF glow discharge at 240m Torr, 40W to investigate the surface morphological changes due to the plasma treatment using atomic force microscopy(AFM). Analysis of the AFM images and Ra(average roughness) revealed that the plasma treatment resulted in significant ablation on the surfaces. The morphological changes and surface roughness, however, were different depending on material characteristics such as heat stability, presence of amorphous region, swelling phenomenon, and molecular structure of repeating unit. It was assumed that polypropylene due to its tertiary hydrogen was ablated easily compared to poly(ethylene terephthalate), and that polyimide was more resistant to the ablation than PET due to rigid skeleton of imide and stable phenyl ring structure.