• 제목/요약/키워드: performance tests and methods

검색결과 1,105건 처리시간 0.03초

갑상선 유두암의 외과적 절제술 이후 발생한 후유증에 대한 면역요법을 병행한 한방 치험 3례 (A Case Report on Papillary Thyroid Cancer Patients after Thyroidectomy Treated with Korean Medicine and Immunotherapy)

  • 고은비;장권준;양정민;오재성
    • 대한한방내과학회지
    • /
    • 제42권5호
    • /
    • pp.746-759
    • /
    • 2021
  • Objectives: This study assessed the effect of a combination of Korean medicine and immunotherapy on three papillary thyroid cancer patients following thyroidectomy. Methods: The three patients who underwent thyroidectomy received Korean medical treatments, including acupuncture, moxibustion, pharmacopuncture, and immunotherapy. To evaluate the patients, symptoms were measured using the Numerical Rating Scale (NRS) and Karnofsky Performance Status Scale (KPS). Blood tests, including thyroid function tests, were conducted during treatment. Results: After treatment, postoperative pain and general weakness were gradually alleviated. Conclusions: These cases provide evidence that treatment with a combination of Korean medicine and immunotherapy can have substantial benefits for postoperative complications following thyroidectomy.

Improvement of Condensation Performance in Corridor Type Apartment Door

  • Lee, Sungbok;Hwang, Hajin
    • Architectural research
    • /
    • 제10권1호
    • /
    • pp.33-39
    • /
    • 2008
  • Condensation has mainly occurred in corridor type apartment door which is exposed to the outside air and is made of steel, which has high thermal conductivity. As a result, the total costs of repair have increased with the number of disputes with residents. In this study, therefore, we investigate materials and construction methods used in apartment door, perform a computer simulation to find out possible improvements, and then suggest the dew point to prevent the occurrence of condensation throughout simulation. The results indicate that the temperature that condensation does not occur is $15.4^{\circ}C$, and the optimum method of achieving this dew point is shown to be a door frame system including a large vertical slot to decrease the area of thermal conduction between the outer and inner portions of the door frame. Mock-up tests show that the surface temperature of the door frame was higher than the dew point, and the system can withstand severe cold conditions of $-20^{\circ}C$. In application test, the surface temperature of door frame with vertical slots is $5.9^{\circ}C$in average, which is higher than the existing door frame. Furthermore, in the temperature distribution of the surrounding door measured with infrared ray camera, the existing door shows the high temperature distribution indicating lack of insulation, but the improved door shows the low temperature distribution indicating higher insulation.

실시간 구조물 변위 모니터링을 위한 증분형 변위 측정 알고리즘 (Incremental Displacement Estimation Algorithm for Real-Time Structural Displacement Monitoring)

  • 전해민;신재욱;명완철;명현
    • 제어로봇시스템학회논문지
    • /
    • 제18권6호
    • /
    • pp.579-583
    • /
    • 2012
  • The purpose of this paper is to suggest IDE (Incremental Displacement Estimation) algorithm for the previously proposed visually servoed paired structured light system. The system is composed of two sides facing with each other, each with one or two lasers with a 2-DOF manipulator, a camera, and a screen. The 6-DOF displacement between two sides can be estimated by calculating the positions of the projected laser beams and rotation angles of the manipulators. In the previous study, Newton-Raphson or EKF (Extended Kalman Filter) has been used as an estimation algorithm. Although the various experimental tests have validated the performance of the system and estimation algorithms, the computation time is relatively long since aforementioned algorithms are iterative methods. Therefore, in this paper, a non-iterative incremental displacement estimation algorithm which updates the previously estimated displacement with a difference of the previous and the current observed data is introduced. To verify the performance of the algorithm, experimental tests have been performed. The results show that the proposed non-iterative algorithm estimates the displacement with the same level of accuracy compared to the EKF with multiple iterations with significantly less computation time.

Relation between Multiple Markers of Work-Related Fatigue

  • Volker, Ina;Kirchner, Christine;Bock, Otmar L.
    • Safety and Health at Work
    • /
    • 제7권2호
    • /
    • pp.124-129
    • /
    • 2016
  • Background: Work-related fatigue has a strong impact on performance and safety but so far, no agreed upon method exists to detect and quantify it. It has been suggested that work-related fatigue cannot be quantified with just one test alone, possibly because fatigue is not a uniform construct. The purpose of this study is therefore to measure work-related fatigue with multiple tests and then to determine the underlying factorial structure. Methods: Twenty-eight employees (mean: 36.11; standard deviation 13.17) participated in five common fatigue tests, namely, posturography, heart rate variability, distributed attention, simple reaction time, and subjective fatigue before and after work. To evaluate changes from morning to afternoon, t tests were conducted. For further data analysis, the differences between afternoon and morning scores for each outcome measure and participant (${\Delta}$ scores) were submitted to factor analysis with varimax rotation and each factor with the highest-loading outcome measure was selected. The ${\Delta}$ scores from tests with single and multiple outcome measures were submitted for a further factor analysis with varimax rotation. Results: The statistical analysis of the multiple tests determine a factorial structure with three factors: The first factor is best represented by center of pressure (COP) path length, COP confidence area, and simple reaction time. The second factor is associated with root mean square of successive difference and useful field of view (UFOV). The third factor is represented by the single ${\Delta}$ score of subjective fatigue. Conclusion: Work-related fatigue is a multidimensional phenomenon that should be assessed by multiple tests. Based on data structure and practicability, we recommend carrying out further studies to assess work-related fatigue with manual reaction time and UFOV Subtest 2.

무기질 첨가제를 사용한 상온 재활용 아스팔트 혼합물의 공용성 평가 (Performance Evaluation of Cold-Recycling Asphalt Mixtures with an Inorganic Additive)

  • 김경수;김현겸;김원재;박창규;이현종
    • 한국도로학회논문집
    • /
    • 제20권1호
    • /
    • pp.27-33
    • /
    • 2018
  • PURPOSES : The purpose of this study is to estimate the optimum content of an inorganic additive for cold-recycled asphalt mixtures and evaluate its performance. METHODS : An indirect tensile test, a tensile-strength ratio test, and an indirect tensile-fatigue test were conducted on cold-recycling asphalt mixtures with various additives. RESULTS : The laboratory performance tests indicated that granulated blast-furnace slag mixed with inorganic and cement activators provided optimum performance. The performance results of the cold-recycled asphalt pavement were similar to the inorganic and cement activators' performance in terms of the indirect tensile strength, tensile strength ratio, and indirect tensile-fatigue test. CONCLUSIONS : Overall, the performance of a cold-recycled asphalt mixture using inorganic additives and emulsion asphalt was comparable to a warm-recycled asphalt mixture. However, more experiments aimed at improving its performance and studying the effect of the inorganic additives must be conducted.

Industrial dairy wastewater purification by shear-enhanced membrane filtration: The effects of vibration

  • Kertesz, Szabolcs
    • Membrane and Water Treatment
    • /
    • 제5권2호
    • /
    • pp.73-86
    • /
    • 2014
  • Membrane fouling is a major challenge limiting the use of membrane applications. In this study high induced shear rates were utilized at the membrane surface in order to reduce the organic and inorganic scaling by using the torsional vibration of flat sheet membranes. The performances of a vibratory shear-enhanced processing (VSEP) system for the ultrafiltration (UF), nanofiltration (NF) and reverse osmosis (RO) membrane filtration of industrial dairy wastewater were investigated. The vibration and non-vibration methods were compared with the same membrane and operational parameters during the purification of real dairy industrial process wastewater. In the initial experiments, short-term tests were carried out in which the effects of vibration amplitude, recirculation flow rate and transmembrane pressure were measured and compared. The permeate flux, turbidity, conductivity and chemical oxygen demand (COD) reduction of dairy wastewater were investigated by using UF, NF and RO membranes with vibration and non-vibration methods. In the subsequent experiments, concentration tests were also carried out. Finally, scanning electron microscopy (SEM) revealed that the vibration method gave a better performance, which can be attributed to the higher membrane shear rate, which reduces the concentration of solids at the membrane, and the transmission.

On a Robust Test for Parallelism of Regression Lines against Ordered Alternatives

  • Song, Moon-Sup;Kim, Jin-Ho
    • Communications for Statistical Applications and Methods
    • /
    • 제4권2호
    • /
    • pp.565-579
    • /
    • 1997
  • A robust test is proposed for the problem of testing the parallelism of several regression lines against ordered alternatives. The proposed test statistic is based on a linear combination of one-step pairwise GM-estimators. We compare the performance of the proposed test with that of the other tests through a Monte Carlo simulation. The results of the simulation study show that the proposed test has stable levels, good empirical powers in various circumstances, and particularly higher empirical powers under the presence of extreme outliers or leverage points.

  • PDF

A Family of Tests for Trend Change in Mean Residual Life with Known Change Point

  • Na, Myung-Hwan;Kim, Jae-Joo
    • Communications for Statistical Applications and Methods
    • /
    • 제7권3호
    • /
    • pp.789-798
    • /
    • 2000
  • The mean residual function is the expected remaining life of an item at age x. The problem of trend change in the mean residual life is great interest in the reliability and survival analysis. In this paper, we develop a family of test statistics for testing whether or not the mean residual life changes its trend. The asymptotic normality of the test statistics is established. Monte Carlo simulations are conducted to study the performance of our test statistics.

  • PDF

Low Cost and High Performance Single Phase UPS Using a Single-Loop Robust Voltage Controller

  • Ji, Jun-Keun;Ku, Dae-Kwan;Lim, Seung-Beom
    • Journal of Power Electronics
    • /
    • 제15권3호
    • /
    • pp.695-701
    • /
    • 2015
  • Uninterruptible Power Supplies (UPSs) can be largely divided into the passive-standby, line-interactive and double-conversion methods. This paper proposes a double-conversion UPS with a low cost and high performance. This single phase UPS uses a single-loop robust voltage controller and 1-switch voltage doubler strategy PFC. The proposed UPS is composed of a single phase PFC, a half-bridge inverter, a battery charger and a battery discharger. Finally, the validity of proposed UPS was verified by various experimental tests.

테이퍼 그리드 커플링의 신뢰성 평가에 관한 연구 (Study on Reliability Evaluation for a Taper Grid Coupling)

  • 정동수
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제17권4호
    • /
    • pp.343-354
    • /
    • 2017
  • Purpose: This paper evaluates the reliability of tapered grid couplings and presents test results through performance and life tests. Methods: The performance and life test method were presented by analyzing the failure modes for the tapered grid coupling. Zero failure test time was calculated to evaluate the reliability of tapered grid couplings and the test was performed under accelerated conditions. The nondestructive test and wear analysis using weighing were also carried out to check the failure modes of the field conditions. Conclusion: This study can be provided to improve the product reliability through failure analysis of a tapered grid coupling. The performance test results of before and after the accelerated life test were presented to confirm the improved reliability of the tapered grid coupling.