• Title/Summary/Keyword: penetrating

Search Result 999, Processing Time 0.028 seconds

Field Cooling Tests of Paddy Stored in Steel Bins with a Grain Cooler (곡물냉각기를 이용한 철제 원형빈에서 벼 냉각)

  • 김의웅;김동철
    • Food Science and Preservation
    • /
    • v.11 no.2
    • /
    • pp.263-268
    • /
    • 2004
  • Two field cooling tests were conducted to evaluate the cooling characteristic of paddy with a prototype grain cooler. The first test was carried out during summer season in a steel bin with 180.3ton of paddy at Sunchon. And the second test was carried out during harvesting season in a steel bin with 272.2ton of paddy at Ulsan. At the first test, initial paddy temperature of 23.6$^{\circ}C$ was dropped to 14$^{\circ}C$, and initial moisture content of 19.9% was dropped to 19.3% after 52.5 hours of cooling. At the second test, initial paddy temperature of 16.1$^{\circ}C$ dropped to 5.5$^{\circ}C$ after 78.0 hours of cooling. And, at the first test, the average air flow rates of chilled air leaving the grain cooler and penetrating the grain layer were 77.5 ㎥/min and 42.5 ㎥/min, respectively. To prevent leakage of chilled air from plenum chamber of steel bin, which was about 45% of the average air flow rates of chilled air leaving the grain cooler, a proper method was required. The average total power consumption at the first test during summer was 22.1 ㎾ with control of fan damper. At the second test, it was 17.4 ㎾ due to controlling the capacity of compressor with unloading solenoid valve and changing the flow rates of hot refrigerant gas flowing into evaporator and reheater from compressor, resulting in 27% reduction of energy consumption.

GPR Analysis on Underground Features and Foundation Structure of Cheomseongdae, Gyeongju (GPR 탐사를 통해 본 경주 첨성대 기초 및 주변의 유구 분석)

  • Oh, Hyundok;Kwon, Moonhee;Jang, Hangilro
    • Korean Journal of Heritage: History & Science
    • /
    • v.52 no.4
    • /
    • pp.264-271
    • /
    • 2019
  • Cheomseongdae in Gyeongju, known as an astronomical observatory, is a cultural monument with great historical, academic, and artistic value, as its unique shape is preserved well in its original form. The outer structure, ground stability, and seismic reliability of Cheomseongdae have been assessed by numerous researchers through various scientific methods, but research on the underground structure has been insufficient. This paper contains detailed models of the underground structure of Cheomseongdae interpreted in 2D and 3D images based on the data acquired through GPR surveys conducted of features in and around the base of Cheomseongdae. As a result, the existence of twelve small features arranged in a circle, although only about half of them remain, was confirmed at a depth of 0.4 - 0.6m. Furthermore, a structure three bays long (north-south direction) and four bays wide (east-west direction) was detected beneath Cheomseongdae at the depth of 0.7 - 1.0m. Other than 2 layers of foundations as is known, a square structure with the dimensions of 7m × 7m is situated at a depth of 0.6m, directly under Cheomseongdae, and what is reading that is expected to be the foundation structure of Cheomseongdae was detected and confirmed. This foundation structure is circular with a diameter in the east-west direction of 11m and in the north-south direction of 12m. The northern, western, and eastern edges of this foundation structure are about 1m away from the foundation of Cheomseongdae, whereas the the south side extends to about 5m wide.

An Analysis Affecting Commercial Use Penetration within Single-detached Residential Units in the Residential Development Complexes : Focused on Cheong-ju Cases (택지개발지구 단독주택용지내 상업용도 침투의 영향요소 분석 : 청주시 사례를 중심으로)

  • Song, Sun-Gi;Jung, Yun-Kwang;Hwang, Hee-Yun
    • Journal of the Korean association of regional geographers
    • /
    • v.16 no.1
    • /
    • pp.34-47
    • /
    • 2010
  • The purpose of this study is to investigate the actual condition of commercial use of housing site in residential development complexes, and to derive effective future development plan by analyzing the influence of penetrating factors of commercial use. The foJlowing are the results of the analysis. First, characteristics of roads showed that the wider the widths of roads adjoining individual lots have more influences on commercial use penetration. This means that non-residential facilities tend to be located on regions where frequencies of uses are high, preferring regions having good transportation accessibility. Second, characteristics of adjacent usage showed that the distances of common housing, neighborhood facilities, schools to single-detached residential units acted as a factor for higher penetration ratio of commercial use when they were closer.ors an opposite, it showed as distances to parks were further, the penetration ratio were higher. This can be inferred that the condition of detached houses located closer to parks have pleasure environment, and act as a factor preventing commercial use penetration. Third, the official land price presents as a form of quality, as the analysis showed that the higher official land price, the more it acts as a factor increasing the penetration ratio of commercial use.

  • PDF

Determination of paraquat-resistant biotype on Conyza canadensis and the resistant mechanism (Paraquat 저항성 생태형 망초의 선발과 저항성 기작)

  • Kim, Sung-Eun;Kim, Seung-Yong;Ahn, Sul-Hwa;Chun, Jae-Chul
    • The Korean Journal of Pesticide Science
    • /
    • v.9 no.1
    • /
    • pp.88-96
    • /
    • 2005
  • Paraquat-resistant biotype of Conyza canadensis (L.) Cronq. was determined by chlorophyll loss and random amplified polymorphic DNA (RAPD) analysis and the resistant mechanism was investigated with respect to absorption, translocation, and binding constant. RAPD analysis for paraquat resistant (R) and susceptible (S) biotypes found in a pear orchard revealed that the biotypes possessed remote genetic relationship. Chlorophyll loss, as an indication of paraquat toxicity, of S biotype was 7.8-fold greater than that of R biotype. There were no differences in contents of epicuticular wax and cuticle and amounts of [14C]paraquat penetrating the cuticle between the two biotypes. Little translocation of the herbicide out of the treated leaf was observed in either biotype. Binding constants of paraquat to the cell wall and thylakoid membrane were 7.4-fold and 16.9-fold, respectively, higher in R biotype than in S biotype. The results suggest that the resistance mechanism of C. canadensis biotype is due partly to high binding affinity of paraquat to the cell wall and thylakoid membrane.

ESTIMATING THE VOLUME OF CONSTRUCTION-WASTE LANDFILL USING GEOPHYSICAL TECHNIQUES (물리탐사 기법을 이용한 건축 폐기물 매립지의 규모 파악)

  • Mun,Yun-Seop;Lee,Tae-Jong;Lee,Chae-Yeong;Yun,Jun-Gi
    • Journal of the Korean Geophysical Society
    • /
    • v.6 no.1
    • /
    • pp.13-23
    • /
    • 2003
  • Dipole-dipole resistivity and ground penetrating radar(GPR) surveys were performed on an abandoned landfill site filled with asbestos containing material. The main purpose of the study was to estimate spatial extension and volume of the landfill for evaluting the cost for developing appropriate remedial alternatives. Assuming that the bedrock is within 10 m depth, dipole spacings of 2, 2.5 and 5m were set for six survey lines for resistivity measurements. For More detailed information, GPR suvey using 225 Mhz antenna was carried out for twelve survey lines for the shallower information. DC resistivity structures showed few tens ~ hundreds ohm-m for the landfill or alluvial laver, and 1,000~ 5,000 ohm-m for the bedrock. The depth to bedrock is found out to be approximately 5m. GPR survey results represented very clear reflection and/or diffraction events from the boundaries as well as from the blocky construction wastes. With high-resolution GPR survey, depth of the bedrock was resolved up to 2m, which in turn, could be a good indicator for estimating the volume of the landfill. Those depths of bedrock were confirmed by backhoe excavation data for 13 sites. The total area and volume of the landfill were to be approximately 3,953 .$m^2$ and 4,033 $m^3$, respectively.

  • PDF

Effects of Antenna Modeling in 2-D FDTD Simulation of an Ultra-Wide Band Radar for Nondestructive Testing of a Concrete Wall (콘크리트 벽의 비파괴검사를 위한 초광대역 레이더의 2차원 FDTD 시뮬레이션에서 안테나 모델링의 영향)

  • Joo, Jeong-Myeong;Hong, Jin-Young;Shin, Sang-Jin;Kim, Dong-Hyeon;Oh, Yisok
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.1
    • /
    • pp.98-105
    • /
    • 2013
  • This paper presents a finite-difference time-domain(FDTD) simulation and a data processing technique for radar sensing of the internal structure of a wall using an ultra-wide band antenna. We first designed an ultra-wide band anti-podal vivaldi antenna with a frequency range of 0.3~7 GHz which is chosen to be relatively low after considering the characteristics of wave attenuation, wall penetration, and range resolution. In this study the two-dimensional FDTD technique was used to simulate a wall-penetration-radar experiment under practical conditions. The next, the measured radiation pattern of the practical antenna is considered as an equivalent source in the FDTD simulation, and the reflection data of a concrete wall and targets are obtained by using the simulation. Then, a data processing technique has been applied to the FDTD reflection data to get a radar image for remote sensing of the internal structure of the wall. We compared the two different source excitations in the FDTD simulation; (1) commonly-used isotropic point sources and (2) polynomial curve fitting sources of the measured radiation pattern. As a result, when we apply the measured antenna pattern into the FDTD simulation, we could obtain about 2.5 dB higher signal to noise level than using a plane wave incidence with isotropic sources.

A Case of Coronary-Pulmonary Artery Fistula (관상동맥-폐동맥 누공 1예)

  • Lee, Kyung Hae;Wang, Joon Kwang;Shin, Sung Joon;Kim, Mi Ok;Kim, Tae Hyung;Son, Jang Won;Yun, Ho Ju;Shin, Dong Ho;Park, Sung Soo;Kim, Kyung Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.56 no.4
    • /
    • pp.420-425
    • /
    • 2004
  • Fistula between coronary artery and pulmonary artery is a type of coronary artery anomalies. It can cause atypical chest pain and fatigue, angina pectoris, endocarditis, finally myocardial steal can result in heart failure and myocardial infarction. But only 0.1-0.2% of coronary angiographic studies reveal the communications between coronary artery and other spaces. (heart chamber, pulmonary artery etc.) It is frequently congenital, but acquired types are increasing because chest and heart manipulations such as opertion of tetralogy of Fallot, endomyocardial biopsy, radiation therapy, or penetrating blunt trauma are increasing. There are reports about repair of fistula using thrombogenic tips, coil embolization and surgical intervention. We report a connection between coronary artery and pulmonary artery in 79 years old female. She was 30 pack-years smoker and suffered from dyspnea several years with chronic obstructive pulmonary disease. She presented with atypical chest pain and palpitation after admission. Electrocardiography showed ST-T wave abnormality. Emergency coronary angiography and chest CT scan revealed coronary-pulmonary artery fistula. Transcatheter embolization was performed and she was relieved from discomforts.

A study on the occurrence of cracks in the tunnel pavement in the soil under use (토사구간 공용중 터널 포장부 균열 발생에 관한 연구)

  • Kim, Nag-Young;Lee, Kang-Hyun;Cho, Nam-Hun;You, Kwang-Ho;Baek, Seung-Chol
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.5
    • /
    • pp.749-760
    • /
    • 2017
  • Recently, the proportion of tunnel structures in roads and railways has increased rapidly. Along with this trend, the rate of occurrence of cracks and dropouts in concrete lining of tunnel structures is increasing. Generally, maintenance of such concrete lining is normalized and managed as the core of maintenance work in tunnel maintenance. However, the maintenance of the tunnel pavement is important in securing driver in the tunnel. In the design of tunnels, the underground condition of the tunnel is designed to be in good rock condition, so there have not been many cases of cracks in the tunnel pavement in the past. Recently, the construction of tunnel structures has been rapidly increased, and the length of the tunnels has become longer.Tunnel pavement installed in these ground conditions is increasing the occurrence of cracks in the pavement due to decrease of bearing capacity of the pavement after a long time. In this study, FWD and GPR were conducted to analyze the types of cracks and the reduction of bearing capacity in the tunnel.

A geophysical survey result over a hydrocarbon contaminated site (물리탐사를 이용한 국내 유류오염지역 조사 사례)

  • Song Yoonho;Park Sam Gyu;Seol Soon Jn;Choi Seong-Jun;Chung Seung-Hwan
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2001.09a
    • /
    • pp.122-140
    • /
    • 2001
  • We have applied the geophysical survey, mainly electric and electromagnetic (EM) methods, to a test site contaminated by hydrocarbon waste disposal and local spill. The multi-frequency, moving source & receiver EM survey along with ground penetrating radar (GPR) showed a fairly good performance in detection of buried metal pipes and objects. Magnetic survey measuring vertical and horizontal gradients were so sensitive to the small metallic objects spread over the surface that it's hard to discriminate the buried pipe. We chose electrical resistivity, EM and GPR survey to examine the soil contamination. Depth slices of resistivity distribution as the results of the inversion of resistivity and EM data coincided each other and closely matched the contaminated area determined by chemical analysis of the soil samples. GPR images did not show the reflection events related with contamination plume since there are no distinct spill in this site. We inferred the contamination using the penetration depth of the GPR energy, which could be used as auxiliary information to the resistivity and EM results. We summarized the applicability of each survey methods based on this results and proposed a desirable survey scheme for the determination of hydrocarbon contaminated site.

  • PDF

Design of a TL Personal Dosimeter Identifiable PA Exposure and Development of Its Dose Evaluation Algorithm (후방피폭선량계측이 가능한 TL 개인선량계의 설계 및 선량평가 알고리즘 개발)

  • Kwon, J.W.;Kim, H.K.;Yang, J.S.;Kim, J.L.;Lee, J.K.
    • Journal of Radiation Protection and Research
    • /
    • v.29 no.3
    • /
    • pp.179-186
    • /
    • 2004
  • A single-dosimeter worn on the anterior surface of body of a worker was found to provide significant underestimation of dose to the worker when radiation comes from behind of the human body. Recently, several researchers suggested that this kind of underestimation can be corrected to a certain extent by using an extra dosimeter on the back. But this multiple dosimetry also has the disadvantages like overestimation lowering work efficiency or cost burden. In this study, a single dosimeter introducing asymmetric filters enabled to identify PA exposure was designed by monte-carlo simulation and experiments and its dose evaluation algorithm for AP-PA mixed radiation field was established. This algorithm was applicable to penetrating radiation which had the effective energy more than 100 keV. Besides, the dosimeter and algorithm in this study were possible to be applied to near PA exposure.