Design of a TL Personal Dosimeter Identifiable PA Exposure and Development of Its Dose Evaluation Algorithm

후방피폭선량계측이 가능한 TL 개인선량계의 설계 및 선량평가 알고리즘 개발

  • Kwon, J.W. (Dept. of Nuclear Engineering Hanyang University) ;
  • Kim, H.K. (Korea Atomic Energy Research Institute) ;
  • Yang, J.S. (Korea Atomic Energy Research Institute) ;
  • Kim, J.L. (Korea Atomic Energy Research Institute) ;
  • Lee, J.K. (Dept. of Nuclear Engineering Hanyang University)
  • Published : 2004.09.30

Abstract

A single-dosimeter worn on the anterior surface of body of a worker was found to provide significant underestimation of dose to the worker when radiation comes from behind of the human body. Recently, several researchers suggested that this kind of underestimation can be corrected to a certain extent by using an extra dosimeter on the back. But this multiple dosimetry also has the disadvantages like overestimation lowering work efficiency or cost burden. In this study, a single dosimeter introducing asymmetric filters enabled to identify PA exposure was designed by monte-carlo simulation and experiments and its dose evaluation algorithm for AP-PA mixed radiation field was established. This algorithm was applicable to penetrating radiation which had the effective energy more than 100 keV. Besides, the dosimeter and algorithm in this study were possible to be applied to near PA exposure.

인체의 전면에 착용하는 단일선량계는 비균질 방사선장에서 작업자의 피폭을 대표하지 못할 수 있으며 특히 방사선이 인체의 후면에서 입사되는 경우 유효선량을 심각하게 저평가 하는 것으로 알려져 있다. 몇몇의 선행연구자들은 비균질 방사선장에서 인체의 후면에 추가의 선량계를 착용하는 복수의 선량계를 이용하는 선량평가를 제안하고 있으나 복수의 선량계를 이용한 선량평가는 과대평가 내지 작업의 효율성 저하 및 비용부담의 문제를 안고 있다. 본 연구는 AP와 PA 방향으로 입사하는 방사선에 대하여 두 개의 TL 소자가 서로 상반되는 반응도를 보이도록 필터를 설계함으로써 단일선량계 사용의 결점을 보완하고 그 활용도를 높이고자 하였다. 즉 빔의 방향에 대한 정보를 제공하는 필터를 몬테칼로 계산과 실험을 통해 도입하고 이 결과를 기반으로 PA 입사에 대한 새로운 선량평가 알고리즘을 개발하였다. 이 알고리즘은 광자의 유효에너지가 100keV이상으로 입사방사선의 인체투과율이 상당한 경우에 적용 가능하다. 또한 정확히 후방입사가 아닌 기타 방향의 후방피폭의 경우에도 본 연구에서 수립된 알고리즘의 적용 가능성을 확인하였다.

Keywords

References

  1. ICRU, Measurement of Dose Equivalents from External Photon and Electron Radiations, International Commission on Radiation Units and Measurements, ICRU Report 47(1992)
  2. ICRU, Quantities and Units in Radiation Protection Dosimetry, International Commission on Radiation Units and Measurements, ICRU Report 51(1993)
  3. A.R. Lakshmanan, R.K. Kher and S.J. Supe 'Estimation of dose equivalent using individual dosimeter,' Radiat. Prot. Dosim,35,4,247-252(1991)
  4. C.H. Kim, 'Use of two dosimeters for better estimation of effective dose,'College station, TX: Texas A&M University(1998)
  5. C.H.Kim, W.D. Reece and J.W.Poston,'Development of a two-dosimeter algorithm for better estimation of effective dose equivalent and effective dose,' Radiat. Prot.Dosim.81,101-112(1999)
  6. C.G. Hudson, 'The need for dosimetry multibadging at nuclear power plants,' Radiat. Prot. Mgt. January,43-49(1984)
  7. 김두영,양정선,김장렬.이정일,김봉환.장시영,'신TL물질 $CaSO_4$:Dy,P(KCT-300) 소자의 개발,' 2001 한국원자력학회 춘계학술발표회(2001)
  8. 양정선,김두영,김장렬,이정일,남영미,장시영,$CaSo_4$:Dy 분말의 제조 및 TL 특성,' 2001 한국원자력학회 춘계학술발표회(2001)
  9. ANSI, Criteria for Perfoming Multiple Dosimetry, American National Standards Institute, HPS N13.41(1997)
  10. 이춘식, 김현기, 이춘익, 이재기,'몬테칼로 모사에 의한 증기발생기 수실 작업자의 유효선량평가,' 대한방사선방어학회 추계학술발표회,154-158(1999)
  11. B. Grosswendt, 'The angular dependence and irradiation geometry factor for the dose equivalents for photons in slab phantoms of tissue equivalent material and PMMA,'Radiat. Prot. Dosim. 35(4), 221-235(1990)
  12. B. Grosswendt, 'Conversion coefficients for calibrating individual dosimeters in terms of dose equivalents defined in an ICRU tissue cube and PMMA slab,' Radiat. Prot. Dosim .32(4),219-231(1990)
  13. ICRP, Conversion. Coefficients for Use in Radiological Protection against External Radiation, International Commission on Radiological Protection, ICRP Publication 74, Pergamon Press(1996)
  14. Judith F. Briesmeister, MCNP-A General Monte Carlo Code N-Particle Transport Code Version 4C, Los AIamos National Laboratory, LA-13709-M(2000)
  15. 김현기, 권정완, 이재기, 김장렬, '광자방사선장에서 $H_p(10)$ 측정을 위한 TLD 필터설계,' 대한방사선방어학회 2002 춘계학술발표회 및 심포지움(2002)
  16. H.K. Kim, J. W. Kwon, J. K. LEE, J.L. Kim, 'Design of a Personnel Dosimetry badge system for a new TL Material $CaSO_4$:Dy, P,' Proc. of the 1st Asian and Oceanic Congress for Radiation Protection, October 20-24, Seoul, Korea(2002)
  17. 권정완, 김현기, 이재기, 김장렬, '비둥방광자방사선장에서 개인선량측정을 위한 TL뱃지의 계산을 통한 필터설계,' 대한방사선방어학회 2002 춘계학술발표회 및 심포지엄(2002)
  18. J.W. Kwon, H. K. Kim, J. K. Lee, J. L. Kim, Feadibility Study of Reducing Errors in the Personal Dose Equivalent from Abnormal Exposure Directions by Use of Asymmetric Filters in a TLD Badge,' Proc. of the 1st Asian and Oceanic Congress for Radiation Protection, October 20-24, Seoul, Korea(2002)