• Title/Summary/Keyword: passive millimeter wave

검색결과 33건 처리시간 0.018초

Study Of Millimeter-Wave Passive Imaging Sensor Using the Horn Array Antenna (반사판을 이용한 밀리미터파 수동 이미징 시스템 연구)

  • Lim, Hyun-Jun;Chae, Yeon-Sik;Jung, Kyung-Kwon;Kim, Mi-Ra;Rhee, Jin-Koo
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • 제47권2호
    • /
    • pp.67-73
    • /
    • 2010
  • We have developed a millimeter-wave passive imaging system with reflector for detection of concealed objects. We have designed a millimeter-wave sensor, control device for reflector control, and a lens for focusing of millimeter-wave signal at center frequency of 94GHz. DC signal from millimeter-wave sensor output is filtered by low pass filter and amplified by video amplifier, and then converted into digital signal by using ADC/DAQ. This signal is image processed by computer, and it is possible to obtain millimeter-wave passive image with resolution of $18{\times}64$ pixel using the fabricated system. It is shown that we can obtain the image of men and concealed object with the system.

Studies on the millimeter-wave Passive Imaging System II (밀리미터파 수동 이미징 시스템 연구 II)

  • Jung, Min-Kyoo;Chae, Yeon-Sik;Kim, Soon-Koo;Yoo, Jin-Seob;Koji, Mizuno;Rhee, Jin-Koo
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • 제44권3호
    • /
    • pp.105-110
    • /
    • 2007
  • We have built the millimeter-wave passive imaging system with a lens and mechanical scan antenna. The lens was designed based on optical theory in order to focus millimeter-wane. A full image was taken from image points scanned by Placing antenna at the representative focal plane selectively. An integrated antenna array device for low-loss and low-noise with the array of 4 by 1, where components such as antenna, balun, MMIC, and detector were assembled on a sin91e substrate, and a fermi tapered slot antenna with high-gain and low-side lobe were used for elements of this millimeter-wave passive imaging system. Two dimensional antenna arrangement on focal plane was achieved in this imaging system.

Study Of Millimeter-Wave Passive Imaging Sensor Using the Horn Array Antenna (혼 배열 안테나를 이용한 밀리미터파 수동 이미징 센서 연구)

  • Lim, Hyun-Jun;Chae, Yeon-Sik;Kim, Mi-Ra;Rhee, Jin-Koo
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • 제47권2호
    • /
    • pp.74-79
    • /
    • 2010
  • We have designed a millimeter-wave passive imaging sensor with multi-horn antenna array. Six horn array antenna is suggested that it is integrated into one housing, and this antenna is effectively configurated m space to assemble with LNA of WR-10 structure. Antenna is designed to have the peak gain of 17.5dBi at the center frequency of 94GHz, and the return loss of less than -25dB in W-band, and the small aperture size of $6mm{\times}9mm$ for antenna configuration with high resolution. LNA is designed to have total gain of more than 55dB and noise figure of less than 5dB for good sensitivity. We made a detector for DC output translation of millimeter-wave signal with zero bias Schottky diode. It is shown that good sensitivity of more than 500mV/mW.

Image Measurement and Processing using Near-Range Passive Millimeter-wave Imaging System (근거리 수동 밀리미터파 이미징 시스템을 이용한 영상 측정과 영상처리)

  • Jung, Kyung Kwon;Yoon, Jin-Seob;Chae, Yeon-Sik
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • 제52권8호
    • /
    • pp.159-165
    • /
    • 2015
  • In this paper, we designed and tested of the passive millimeter-wave imaging system in near range. The proposed passive millimeter-wave imaging system consists two parts. The first part is a 94 GHz band millimeter imaging sensor which is coupled to an antenna, two LNAs, and a diode detector. The second part is a control unit. The control unit is consists of the 2-axes Cartesian robot, the data acquisition (DAQ), and imaging program. The 2-axes Cartesian robot should be able to scan a 2-D image of the metalic tools, IC card and plastic objects, with a raster scanning method. The passive millimeter-wave image of $20{\times}20$ pixels is acquired within less than 60s, and is immediately displayed and stored for post processing.In order to improve the image quality, interpolation methods are applied.

Studies on the millimeter-wave Passive Imaging System (밀리미터파 수동 이미징 시스템 연구)

  • Jung Min-Kyoo;Chae Yeon-Sik;Kim Soon-Koo;Koji Mizuno;Rhee Jin-Koo
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • 제43권5호
    • /
    • pp.182-188
    • /
    • 2006
  • In this study, we have designed the millimeter-wave passive imaging system which records energy that is reflected or emitted from the source and produces image. The lens and front-end of receiver appeared to be important in the system to detect input thermal noise signal. The lens for signal focusing has been designed by optical transfer function. Amplifier of the imaging systemhas been set up with 40dB in maximum gain, 5 dB in maximum noise figure, and 10GHz in bandwidth to enhance sensitivity for thermal noise and to receive it in wide-band width as well. The SBD MSS-20 141B10D diode has been used for the detector circuit to convert amplified millimeter-wave signals to DC output.

Studies on the millimeter-wave Passive Imaging System III (밀리미터파 수동 이미정 시스템 연구 III)

  • Jung, Min-Kyoo;Chae, Yeon-Sik;Kim, Soon-Koo;Yoo, Jin-Seob;Koji, Mizuno;Rhee, Jin-Koo
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • 제44권3호
    • /
    • pp.111-116
    • /
    • 2007
  • We have developed a passive millimeter wave (PMMW) imaging system with two-dimensional imaging arrays. For the imaging system we achieved single-substrate imaging-array element which include all necessary component such as Fermi tapered slot antenna (TSA), a balun, LNA's and a detector circuit on it. Two-dimensional arrays for real-time imaging at the 35 GHz band are currently under development. We will be able to make an advanced PMMW image system based on our system with the $2\times2$ imaging array in the near future.

Image Registration and Fusion between Passive Millimeter Wave Images and Visual Images (수동형 멀리미터파 영상과 가시 영상과의 정합 및 융합에 관한 연구)

  • Lee, Hyoung;Lee, Dong-Su;Yeom, Seok-Won;Son, Jung-Young;Guschin, Vladmir P.;Kim, Shin-Hwan
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • 제36권6C호
    • /
    • pp.349-354
    • /
    • 2011
  • Passive millimeter wave imaging has the capability of detecting concealed objects under clothing. Also, passive millimeter imaging can obtain interpretable images under low visibility conditions like rain, fog, smoke, and dust. However, the image quality is often degraded due to low spatial resolution, low signal level, and low temperature resolution. This paper addresses image registration and fusion between passive millimeter images and visual images. The goal of this study is to combine and visualize two different types of information together: human subject's identity and concealed objects. The image registration process is composed of body boundary detection and an affine transform maximizing cross-correlation coefficients of two edge images. The image fusion process comprises three stages: discrete wavelet transform for image decomposition, a fusion rule for merging the coefficients, and the inverse transform for image synthesis. In the experiments, various types of metallic and non-metallic objects such as a knife, gel or liquid type beauty aids and a phone are detected by passive millimeter wave imaging. The registration and fusion process can visualize the meaningful information from two different types of sensors.

Millimeter-wave Broadband Amplifier integrating Shunt Peaking Technology with Cascode Configuration (Cascode 구조에 Shunt Peaking 기술을 접목시킨 밀리미터파 광대역 Amplifier)

  • Kwon, Hyuk-Ja;An, Dan;Lee, Mun-Kyo;Lee, Sang-Jin;Moon, Sung-Woon;Baek, Tae-Jong;Park, Hyun-Chang;Rhee, Jin-Koo
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • 제43권10호
    • /
    • pp.90-97
    • /
    • 2006
  • We report our research work on the millimeter-wave broadband amplifier integrating the shunt peaking technology with the cascode configuration. The millimeter-wave broadband cascode amplifier on MIMIC technology was designed and fabricated using $0.1{\mu}m\;{\Gamma}-gate$ GaAs PHEMT, CPW, and passive library. The fabricated PHEMT has shown a transconductance of 346.3 mS/mm, a current gain cut off frequency ($f_T$) of 113 GHz, and a maximum oscillation frequency ($f_{max}$) of 180 GHz. To prevent oscillation of designed cascode amplifier, a parallel resistor and capacitor were connected to drain of common-gate device. For expansion of the bandwidth and flatness of the gain, we inserted the short stub into bias circuits and the compensation transmission line between common-source device and common-gate device, and then their lengths were optimized. Also, the input and output stages were designed using the matching method to obtain the broadband characteristic. From the measurement, we could confirm to extend bandwidth and flat gain by integrating the shunt peaking technology with the cascode configuration. The cascode amplifier shows the broadband characteristic from 19 GHz to 53.5 GHz. Also, the average gain of this amplifier is about 6.5 dB over the bandwidth.

Design of High Gain Log-Periodic Tooth Antenna for Image Sensor (이미지 센서용 고이득 Log-Periodic Tooth 안테나 설계)

  • Shim Jae-Ruen
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 한국해양정보통신학회 2006년도 춘계종합학술대회
    • /
    • pp.603-606
    • /
    • 2006
  • In this study, we proposed a Modified Log-Periodic Tooth antenna structure with reflector for millimeter wave image sensor of PMMW(Passive Millimeter Wave). PMMW image sensor satisfy the requirements, such as, High Gain, Wideband, and Planar antenna structure.

  • PDF

A High Gain V-band CPW Low Noise Amplifier

  • Kang, Tae-Sin;Sul, Woo-Suk;Park, Hyun-Chang;Park, Hyung-Moo;Rhee, Jin-Koo
    • Proceedings of the IEEK Conference
    • /
    • 대한전자공학회 2002년도 ITC-CSCC -2
    • /
    • pp.1137-1140
    • /
    • 2002
  • A V-band low-noise amplifiers (LNA) based on the Millimeter-wave monolithic integrated circuit (MIMIC) technology were fabricated using high performance 0.1 $\mu\textrm{m}$ $\Gamma$-shaped pseudomorphic high electron mobility transistors (PHEMT's), coplanar waveguide (CPW) structures and the integrated process for passive and active devices. The low-noise designs resulted in a two-stage MIMIC LNA with a high S$\sub$21/ gain of 14.9 dB and a good matching at 60 ㎓. 20 dBm of IP3 and 3.9 dB of minimum noise figure were also obtained from the LNA. The 2-stage LNA was designed in a chip size of 2.3 ${\times}$1.4 mm$^2$by using 70 $\mu\textrm{m}$ ${\times}$2 PHEMT’s. These results demonstrate that a good low-noise performance and simultaneously with a high gain performance is achievable with GaAs PHEMT's in the 60 ㎓ band.

  • PDF